Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 CrAccepted-AOC VILLAGE FAZALPUR BEHIND FOCAL POINT JALANDHAR | JALANDHAR | JALANDHAR | PUNJAB | ₹4.7 Cr Quoted ₹5.2 Cr | L1 | Accepted-AOC Lower amount quoted |
| 2 | L2₹5.4 Cr+₹18.1 L (3.47%)Rejected-Finance | ₹5.4 Cr+₹18.1 L (3.47%) | L2 | Rejected-Finance Higher amount quoted |
| 3 | L3₹5.6 Cr+₹37.9 L (7.27%)Rejected-Finance 1901 MOROCCAN ROYAL PALMS AAREY COLONY GOREGAON EAST MUMBAI 400065 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | ₹5.6 Cr+₹37.9 L (7.27%) | L3 | Rejected-Finance Higher amount quoted |
| 4 | L4₹5.7 Cr+₹46.1 L (8.84%)Rejected-Finance | ₹5.7 Cr+₹46.1 L (8.84%) | L4 | Rejected-Finance Higher amount quoted |
| 5 | L5₹5.7 Cr+₹46.5 L (8.93%)Rejected-Finance SCO 36 SECTOR 7 C MADHYA MARG CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | ₹5.7 Cr+₹46.5 L (8.93%) | L5 | Rejected-Finance Higher amount quoted |
Tender Value
₹5.6 Cr
EMD Value
₹5.9 L
Closing Date
29 Sept 2021, 11:00 amClosed
Executive Engineer Flood Prot. Division Gagret
Executive Engineer Flood Prot. Division Gagret
(i) Supply and Errection of Submersible/Centrifugal Pumping Machinery including all accessories (ii) Construction of Pump House, Boundary wall around the Pump house, underground reservoirs and OHSR of various capacity, (iii) Laying, Jointing and test
2021_HPIPH_52266_1
GGT-UNA01-752 No. 4233-72 dt 14.09.2021
Open Tender
Civil Works
Item Rate
270 days
Gagret
As per NIT
13 documents required · 13 mandatory
₹2,500
Executive Engineer Flood Prot. Division Gagret
₹5.9 L
Yes
Chief Engineer (Hamirpur Zone) JSV Hamirpur
18 Feb 2022
14 Sept 2021
29 Sept 2021
14 Sept 2021
29 Sept 2021
14 Sept 2021
14 Sept 2021 - 29 Sept 2021
24 Sept 2021
Amount
Schedule -B1 S/E of Pumping Machinery (Submersible & Centrifugal )
S/E of Submersible Pumping Machinery for T/Well at Guglehar Supply of submersible pumping set of reputed make such as KSB/ Calama / BS/ Worthigton / Sabar/ Seerex /Johnston / Amrut/ lubi/ Hindustan,Groundfos confirming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ; 5659-1978 with upto date amendments, suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to submersible motor of same as that of offered submersible pump make confirming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed, lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear tear.It should also be fitted with a device to make up expantion of water with heating of motor. The pumpset should include water level guard i/c cable ,errection clamps, cable clips and depth gauge etc. and suitable for opertion on data given below. a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation
Discharge =( Q) 3.51 LPS
Total Head =( H) 33.82 Mts.
a) SWL in Tubewell = 10.00 Mtr. bgl.
c) R.L. point of discharge = 405.00 Mtr.
d) Seasonal fluctuation + draught condition + bowl assembly. 9.00 Mtrs.
e) Drawdown in Tubewell =8.00 Mtrs.
f) R.L of lowest point of pumpset installation = 378.00 Mtrs.
g) Static Column lift = 37.00 Mtrs.
Rising main. Column Pipe.
Length 50 Mtrs. Length 37.00 mtr.
Dia meter. 80 mm Dia 125 mm
Class GMS Class GMS. (M)
Pumping hours hours
Altitude of installations above M.S.L. __________mtr.
Characteristic of water.
a) Temperature _______ Deg Cel.
b) Turbidity ________JTU.
c) Allkanity. ___________mg/ l Ca Co3
d) Size of solids ____________mm
e) others
Depth of T/well mtr.
Dia of T/ well assembly 300/200 mm.
Length of assembly pipe.
Dia of housing pipe 300 mm.
Length of housing pipe
OPERATING CONDITIONS.
Type of Current :- A.C.Three Phase.
Frequency:- 50 Cycles /Sec.
Rated Voltage 415 +/- 15 % Volts.
System of earthing: Double Loop earthing as per BIS 3843-1987 Latest.
Speed of Revolution ____________ RPM 2900
MOTOR.
Ref. to BIS code BIS 9283-1979 with upto date amendments.
Type of enclosure of motor: As per BIS ; 4691-1985 ( latest )
Mechanical out put in H.P.
Class of insulation :Class B
The motor should be able to withstand initial current of 2.50 times the rated current for two minutes without suffering damages of permanent deformations.
Ref. to BIS code ; BIS ; 5659-1978 with upto date amendments.
Drive Type: Electric driven.
Operating Range: -15 % to+10 % of Total head at duty point.
Deliver size of Pump : ________( To be quoted by tenderer.)
Providing ICTP Main Switch with HRC fuses of L&T/ Havells make and having capacity 30% extra of the operational rating as per IS : 13947-P I & II with upto date amendments. ICTP Switch: i) Make : ii) Type : iii) Capacity : 32.00 Amp.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type ) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. . Panel /Switch Board. i) Drawing.ii) layout Plan.
MCB of kilburn / L&T/ Havells make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. MCB 1) Make. ii) Type iii) Range. 32 Amp. iv) Capacity.
ii) ELCB of recommended make L&T / Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELCB 1) Make. ii) Type iii) Range. 32 Amp. iv) Capacity.
iii) The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition ) Volatage Monitor Relay i) Make ii ) Type iii) Range 0-500
d) Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ;8084-1976 and IS :11353-1985 read with BIS ; 5578 -1985 with upto date amendments including. Bus Bar Chamber i) Type ii) Make iii) Rating
Three phase indicator lamps complete with toggle switches for indivual motors as per IS 3452 ( P- I&II ) with upto date amendments. 3 phase indicators
e) Capacitor of BHEL / GEC / L&T / Mecheil make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter / IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB. Capacitor i) Type ii) Make iii) Range 2 KVAR
Providing suitable starter of L&T /BHEL make as per IS : 13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release, with or without initial oil filling as the case may be with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments. Starter i) Type ii) Make Single phase preventor i) Type ii) Make
Providing and fixing double flanged Cast Iron Sliuce valve of Leader / Kirloskar/Kartar/LP brand approved make for the Column pipe of pump and capable of withstanding the normal seat pressure and as per IS 780-1992 with latest ammendments Class PN 1.00 For Column Pipe 125 mm dia Sluice valve i) Make ii) Class PN 1.00 iii) Material Cast iron
Providing and fixing digital pressure gauge of Prega / Precision / Fiebig make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements Pressure Gauge i) Make
Supply of PVC jointless,flat water proof cable with copper conductor as per BIS 694-1998 latest with upto date ammendments of Havelles/Finolex make suitable for the pumpsets offered from MCB to motor including all other electrical equipments / accessories such as thimble, flexible pipe,solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor.The type, size and make shall be subject to approval of HPSEB authorities. Submersible cable i) Finolex/ Havells make ii) Size 2.50 mm2 (iii) Core=3
Providing and Lowering of GMS Column pipe for assembly 100 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber / asbestos gasket of min.3 mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 .The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under item No.5 . The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main .The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2 Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. Column pipe i) Size 125 mm dia ii) Class (M) iii) Length
Installation of all items appearing as above as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) Supply side from meter of HPSEB to Bus Bar and Switch i) Size 2.50 mm2 ii) Make iii) Type iv) Capacity v) core
Providing and fixing double loop earthing with GI plate of 600x600x6.3 mm thick electrode complete with material such as thimble, nuts and bolts, charcoal, salt as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge. i) GI wire 8SWG
Providing and installation of sensor based auto cut off system for dry run condition of submersible pump as per approved specification and as directed by Engineer-in-Charge
S/E of Submersible Pumping Machinery for T/Well at Andora
Supply of submersible pumping set of reputed make such as KSB/ Calama / BS/ Worthigton / Sabar/ Seerex /Johnston / Amrut/ lubi/ Hindustan,Groundfos confirming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ; 5659-1978 with upto date amendments, suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to submersible motor of same as that of offered submersible pump make confirming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed, lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear tear.It should also be fitted with a device to make up expantion of water with heating of motor. The pumpset should include water level guard i/c cable ,errection clamps, cable clips and depth gauge etc. and suitable for opertion on data given below. a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation.
Discharge =( Q) 9.43 LPS
Total Head =( H) 61.53 Mts.
a) SWL in Tubewell = 16.77 Mtr. bgl.
c) R.L. point of discharge = 510.00 Mtr.
d) Seasonal fluctuation + draught condition + bowl assembly. 9.00 Mtrs.
e) Drawdown in Tubewell =24.39 Mtrs.
f) R.L of lowest point of pumpset installation = 456.84 Mtrs.
g) Static Column lift = 53.16 Mtrs.
Rising main. Column Pipe.
Length 50 Mtrs. Length 60.16 mtr.
Dia meter. 80 mm Dia 100 mm
Class GMS Class GMS. (M)
Pumping hours hours
Altitude of installations above M.S.L. __________mtr.
Characteristic of water.
a) Temperature _______ Deg Cel.
b) Turbidity ________JTU.
c) Allkanity. ___________mg/ l Ca Co3
d) Size of solids ____________mm
e) others
Depth of T/well mtr.
Dia of T/ well assembly 200 mm.
Length of assembly pipe.
Dia of housing pipe 300 mm.
Length of housing pipe
OPERATING CONDITIONS.
Type of Current :- A.C.Three Phase.
Frequency:- 50 Cycles /Sec.
Rated Voltage 415 +/- 15 % Volts.
System of earthing: Double Loop earthing as per BIS 3843-1987 Latest.
Speed of Revolution ____________ RPM 2900
MOTOR.
Ref. to BIS code BIS 9283-1979 with upto date amendments.
Type of enclosure of motor: As per BIS ; 4691-1985 ( latest )
Mechanical out put in H.P.
Class of insulation :Class B
The motor should be able to withstand initial current of 2.50 times the rated current for two minutes without suffering damages of permanent deformations.
Ref. to BIS code ; BIS ; 5659-1978 with upto date amendments.
Drive Type: Electric driven.
Operating Range: -15 % to+10 % of Total head at duty point.
Deliver size of Pump : ________( To be quoted by tenderer.)
Providing ICTP Main Switch with HRC fuses of L&T/ Havells make and having capacity 30% extra of the operational rating as per IS : 13947-P I & II with upto date amendments. ICTP Switch: i) Make : ii) Type : iii) Capacity : 63 Amp.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type ) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections.Panel /Switch Board. i) Drawing.ii) layout Plan.
MCB of kilburn / L&T/ Havells make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. MCB 1) Make. ii) Type iii) Range. 63 Amp. iv) Capacity.
ii) ELCB of recommended make L&T / Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELCB 1) Make. ii) Type iii) Range. 63 Amp. iv) Capacity.
iii) The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition ) Volatage Monitor Relay i) Make ii ) Type iii) Range 0-500
d) Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ;8084-1976 and IS :11353-1985 read with BIS ; 5578 -1985 with upto date amendments including. Bus Bar Chamber i) Type ii) Make iii) Rating
Three phase indicator lamps complete with toggle switches for indivual motors as per IS 3452 ( P- I&II ) with upto date amendments. 3 phase indicators
e) Capacitor of BHEL / GEC / L&T / Mecheil make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter / IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB. Capacitor i) Type ii) Make iii) Range 4 KVAR
Providing suitable starter of L&T /BHEL make as per IS : 13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release, with or without initial oil filling as the case may be with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments. Starter i) Type ii) Make Single phase preventor i) Type ii) Make
Providing and fixing double flanged Cast Iron Sliuce valve of Leader / Kirloskar/Kartar/LP brand approved make for the Column pipe of pump and capable of withstanding the normal seat pressure and as per IS 780-1992 with latest ammendments Class PN 1.00 For Column Pipe 125 mm dia Sluice valve i) Make ii) Class PN 1.00 iii) Material cast iron
Providing and fixing digital pressure gauge of Prega / Precision / Fiebig make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements Pressure Gauge i) Make
Supply of PVC jointless,flat water proof cable with copper conductor as per BIS 694-1998 latest with upto date ammendments of Havelles/Finolex make suitable for the pumpsets offered from MCB to motor including all other electrical equipments / accessories such as thimble, flexible pipe,solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor.The type, size and make shall be subject to approval of HPSEB authorities. Submersible cable i) Finolex/ Havells make ii) Size 6.00 mm2 (iii) Core=3
Providing and Lowering of GMS Column pipe for assembly 100 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber / asbestos gasket of min.3 mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 .The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under item No.5 . The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main .The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2 Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. Column pipe i) Size 100 mm dia ii) Class (M) iii) Length
Installation of all items appearing as above as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) Supply side from meter of HPSEB to Bus Bar and Switch i) Size 10.00 mm2 ii) Make iii) Type iv) Capacity v) core
Providing and fixing double loop earthing with GI plate of 600x600x6.3 mm thick electrode complete with material such as thimble, nuts and bolts, charcoal, salt as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge. i) GI wire 25x3mm 15HP to 50HP
Providing and installation of sensor based auto cut off system for dry run condition of submersible pump as per approved specification and as directed by Engineer-in-Charge
S/E of Submersible Pumping Machinery for T/Well at Shiv Bari
Supply of submersible pumping set of reputed make such as KSB/ Calama / BS/ Worthigton / Sabar/ Seerex /Johnston / Amrut/ lubi/ Hindustan,Groundfos confirming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ; 5659-1978 with upto date amendments, suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to submersible motor of same as that of offered submersible pump make confirming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed, lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear tear.It should also be fitted with a device to make up expantion of water with heating of motor. The pumpset should include water level guard i/c cable ,errection clamps, cable clips and depth gauge etc. and suitable for opertion on data given below. a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation.
Discharge =( Q) 4.37 LPS
Total Head =( H) 68.60 Mts.
a) SWL in Tubewell = 10.00 Mtr. bgl.
c) R.L. point of discharge = 491.50 Mtr.
d) Seasonal fluctuation + draught condition + bowl assembly. 9.00 Mtrs.
e) Drawdown in Tubewell =10.00 Mtrs.
f) R.L of lowest point of pumpset installation = 430.40 Mtrs.
g) Static Column lift = 37.00 Mtrs.
Rising main. Column Pipe.
Length 200 Mtrs. Length 37.00 mtr.
Dia meter. 80 mm Dia 125 mm
Class GMS Class GMS. (M)
Pumping hours hours
Altitude of installations above M.S.L. __________mtr.
Characteristic of water.
a) Temperature _______ Deg Cel.
b) Turbidity ________JTU.
c) Allkanity. ___________mg/ l Ca Co3
d) Size of solids ____________mm
e) others
Depth of T/well mtr.
Dia of T/ well assembly 200 mm.
Length of assembly pipe.
Dia of housing pipe 300 mm.
Length of housing pipe
OPERATING CONDITIONS.
Type of Current :- A.C.Three Phase.
Frequency:- 50 Cycles /Sec.
Rated Voltage 415 +/- 15 % Volts.
System of earthing: Double Loop earthing as per BIS 3843-1987 Latest.
Speed of Revolution ____________ RPM 2900
MOTOR.
Ref. to BIS code BIS 9283-1979 with upto date amendments.
Type of enclosure of motor: As per BIS ; 4691-1985 ( latest )
Mechanical out put in H.P.
Class of insulation :Class B
The motor should be able to withstand initial current of 2.50 times the rated current for two minutes without suffering damages of permanent deformations.
Ref. to BIS code ; BIS ; 5659-1978 with upto date amendments.
Drive Type: Electric driven.
Operating Range: -15 % to+10 % of Total head at duty point.
Deliver size of Pump : ________( To be quoted by tenderer.)
Providing ICTP Main Switch with HRC fuses of L&T/ Havells make and having capacity 30% extra of the operational rating as per IS : 13947-P I & II with upto date amendments. ICTP Switch: i) Make : ii) Type : iii) Capacity : 32 Amp.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type ) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections.Panel /Switch Board. i) Drawing.ii) layout Plan.
MCB of kilburn / L&T/ Havells make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. MCB 1) Make. ii) Type iii) Range. 32 Amp. iv) Capacity.
ii) ELCB of recommended make L&T / Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELCB 1) Make. ii) Type iii) Range. 32 Amp. iv) Capacity.
iii) The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition ) Volatage Monitor Relay i) Make ii ) Type iii) Range 0-500
d) Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ;8084-1976 and IS :11353-1985 read with BIS ; 5578 -1985 with upto date amendments including. Bus Bar Chamber i) Type ii) Make iii) Rating
Three phase indicator lamps complete with toggle switches for indivual motors as per IS 3452 ( P- I&II ) with upto date amendments. 3 phase indicators
e) Capacitor of BHEL / GEC / L&T / Mecheil make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter / IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB. Capacitor i) Type ii) Make iii) Range 3 KVAR
Providing suitable starter of L&T /BHEL make as per IS : 13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release, with or without initial oil filling as the case may be with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments. Starter i) Type ii) Make Single phase preventor i) Type ii) Make
Providing and fixing double flanged Cast Iron Sliuce valve of Leader / Kirloskar/Kartar/LP brand approved make for the Column pipe of pump and capable of withstanding the normal seat pressure and as per IS 780-1992 with latest ammendments Class PN 1.00 For Column Pipe 80 mm dia Sluice valve i) Make ii) Class PN 1.00 iii) Material cast iron
Providing and fixing digital pressure gauge of Prega / Precision / Fiebig make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements Pressure Gauge i) Make
Supply of PVC jointless,flat water proof cable with copper conductor as per BIS 694-1998 latest with upto date ammendments of Havelles/Finolex make suitable for the pumpsets offered from MCB to motor including all other electrical equipments / accessories such as thimble, flexible pipe,solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor.The type, size and make shall be subject to approval of HPSEB authorities. Submersible cable i) Finolex/ Havells make ii) Size 2.50 mm2 (iii) Core=3
Providing and Lowering of GMS Column pipe for assembly 80 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber / asbestos gasket of min.3 mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 .The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under item No.5 . The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main .The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2 Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. Column pipe i) Size 80 mm dia ii) Class (M) iii) Length
Installation of all items appearing as above as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) Supply side from meter of HPSEB to Bus Bar and Switch i) Size 2.50 mm2 ii) Make iii) Type iv) Capacity v) core
Providing and fixing double loop earthing with GI plate of 600x600x6.3 mm thick electrode complete with material such as thimble, nuts and bolts, charcoal, salt as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge. i) GI wire 25x3mm
Providing and installation of sensor based auto cut off system for dry run condition of submersible pump as per approved specification and as directed by Engineer-in-Charge
S/E of Submersible Pumping Machinery for T/Well at Amboa
Supply of submersible pumping set of reputed make such as KSB/ Calama / BS/ Worthigton / Sabar/ Seerex /Johnston / Amrut/ lubi/ Hindustan,Groundfos confirming to latest relevent BIS . The pump should be fitted with free fine impellers of suitable alloys as per BIS ; 5659-1978 with upto date amendments, suitable for raw / clear water having greased packed bearing and shell with wound stator on motor side and with shaft protection on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to submersible motor of same as that of offered submersible pump make confirming to BIS ;9283-1979 with upto date amendments, totally dust and water proof for submersible pump, duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed, lubricated bearing and provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear tear.It should also be fitted with a device to make up expantion of water with heating of motor. The pumpset should include water level guard i/c cable ,errection clamps, cable clips and depth gauge etc. and suitable for opertion on data given below. a Pumps :- Specifications i) Make ii) Model iii) No. of stages iv) Manufacter's certificate to be attached Performance i) Discharge ii) Head iii) Efficiency of Pump a) Duty Head b) (+) 10% Duty Head. c) (-) 15% Duty Head d) Performance curve to be attached b) Motors; Specification i) Make ii) Model iii) B.H.P iv) Speed v) Insulation.
Discharge =( Q) 14.80 LPS
Total Head =( H) 78.14 Mts.
a) SWL in Tubewell = 29.88 Mtr. bgl.
c) R.L. point of discharge = 511.00 Mtr.
d) Seasonal fluctuation + draught condition + bowl assembly. 9.00 Mtrs.
e) Drawdown in Tubewell =10.67 Mtrs.
f) R.L of lowest point of pumpset installation = 458.45Mtrs.
g) Static Column lift = 59.55 Mtrs.
Rising main. Column Pipe.
Length 35 Mtrs. Length 59.55 mtr.
Dia meter. 80 mm Dia 80 mm
Class GMS Class GMS. (M)
Pumping hours hours
Altitude of installations above M.S.L. __________mtr.
Characteristic of water.
a) Temperature _______ Deg Cel.
b) Turbidity ________JTU.
c) Allkanity. ___________mg/ l Ca Co3
d) Size of solids ____________mm
e) others
Depth of T/well mtr.
Dia of T/ well assembly 300/200 mm.
Length of assembly pipe.
Dia of housing pipe 300 mm.
Length of housing pipe
OPERATING CONDITIONS.
Type of Current :- A.C.Three Phase.
Frequency:- 50 Cycles /Sec.
Rated Voltage 415 +/- 15 % Volts.
System of earthing: Double Loop earthing as per BIS 3843-1987 Latest.
Speed of Revolution ____________ RPM 2900
MOTOR.
Ref. to BIS code BIS 9283-1979 with upto date amendments.
Type of enclosure of motor: As per BIS ; 4691-1985 ( latest )
Mechanical out put in H.P.
Class of insulation :Class B
The motor should be able to withstand initial current of 2.50 times the rated current for two minutes without suffering damages of permanent deformations.
Ref. to BIS code ; BIS ; 5659-1978 with upto date amendments.
Drive Type: Electric driven.
Operating Range: -15 % to+10 % of Total head at duty point.
Deliver size of Pump : ________( To be quoted by tenderer.)
Providing ICTP Main Switch with HRC fuses of L&T/ Havells make and having capacity 30% extra of the operational rating as per IS : 13947-P I & II with upto date amendments. ICTP Switch: i) Make : ii) Type : iii) Capacity : 63 Amp.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type ) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections.Panel /Switch Board. i) Drawing.ii) layout Plan.
MCB of kilburn / L&T/ Havells make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. MCB 1) Make. ii) Type iii) Range. 40 Amp. iv) Capacity.
ii) ELCB of recommended make L&T / Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELCB 1) Make. ii) Type iii) Range. 40 Amp. iv) Capacity.
iii) The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition ) Volatage Monitor Relay i) Make ii ) Type iii) Range 0-500
d) Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ;8084-1976 and IS :11353-1985 read with BIS ; 5578 -1985 with upto date amendments including. Bus Bar Chamber i) Type ii) Make iii) Rating
Three phase indicator lamps complete with toggle switches for indivual motors as per IS 3452 ( P- I&II ) with upto date amendments. 3 phase indicators
e) Capacitor of BHEL / GEC / L&T / Mecheil make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter / IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB. Capacitor i) Type ii) Make iii) Range 4 KVAR
Providing suitable starter of L&T /BHEL make as per IS : 13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release, with or without initial oil filling as the case may be with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments. Starter i) Type ii) Make Single phase preventor i) Type ii) Make
Providing and fixing double flanged Cast Iron Sliuce valve of Leader / Kirloskar/Kartar/LP brand approved make for the Column pipe of pump and capable of withstanding the normal seat pressure and as per IS 780-1992 with latest ammendments Class PN 1.00 For Column Pipe 100 mm dia Sluice valve i) Make ii) Class PN 1.00 iii) Material cast iron
Providing and fixing digital pressure gauge of Prega / Precision / Fiebig make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements Pressure Gauge i) Make
Supply of PVC jointless,flat water proof cable with copper conductor as per BIS 694-1998 latest with upto date ammendments of Havelles/Finolex make suitable for the pumpsets offered from MCB to motor including all other electrical equipments / accessories such as thimble, flexible pipe,solder, nuts and bolts, cable glands, clips etc, laid in pipes or trenches under floor.The type, size and make shall be subject to approval of HPSEB authorities. Submersible cable i) Finolex/ Havells make ii) Size 4.00 mm2 (iii) Core=3
Providing and Lowering of GMS Column pipe for assembly 100 mm dia including MS flanges' of Table 17 as per IS : 6392-1971 with upto date amendments, rubber / asbestos gasket of min.3 mm thickness as per IS 2712-1979 and required numbers of nuts and bolts as per IS ;1364-1983 .The Column pipe shall be as per relevent IS Code and to withstand 1.50 times total head stipulated under item No.5 . The Column pipe should be extended upto 5 mtr. beyond the outer wall of the pump house in the direction of Rising main .The Column pipe should be properly jointed with the Rising main including all necessary accessories like increaser / reducer, flanges, bends etc, including supporting clamps (2 Nos.) at the top of T/well assembly, and as per the direction of Engineer - in - Charge. Column pipe i) Size 100 mm dia ii) Class (M) iii) Length
Installation of all items appearing as above as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) Supply side from meter of HPSEB to Bus Bar and Switch i) Size 600 mm2 ii) Make iii) Type iv) Capacity v) core
Providing and fixing double loop earthing with GI plate of 600x600x6.3 mm thick electrode complete with material such as thimble, nuts and bolts, charcoal, salt as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge. i) GI wire 25x3mm 15HP to 50HP
Providing and installation of sensor based auto cut off system for dry run condition of submersible pump as per approved specification and as directed by Engineer-in-Charge
Centrifugal Pumping Machinery alongwith allied accessories for GUGLEHAR) (Rising Main)
Providing horizontal spindle, horizontal / radial split casing /end suction ( back pull out arrangement ) Single /double /multi stage of Kirloskar / KSB/ Hindustan/ lubbi/ Groundfos Crupton KSB/Calama/BS/ make as per BIS IS 1520-1980 with upto date ammendments read with IS: 9137-1978 or latest edition suitable for lifting water for under mentioned characteristic with Bronze impellers / priming funnels, casing ring and shaft sleeves of Bronze shaft of stainless steel with cast iron casing, coupled directly through a flexible coupling on a common cast iron / cast steel base plate (base plate to be framed from the manufacturers of the pumping unit only) to slipring / Squirrel cage screen protected drip proof induction motor / motors of standard make such as Crompton / NGEF / GEC / Seimens /Jyoti/ Kirloskar BHEL / ABB suitable for operation on 415 (+/-15%) volts. 50 Cycles /Sec. 3 phase AC electric supply of 2900 RPM.The power of electric motor/ motors should be at least +10% in excess of the maximum power required by the pump / pumps in the Operation range of (+10%) and (-15%) of the duty point head. The motor / motors as per IS 325 IS -1978 with upto date amendments read with IS 900 -1972. It should include cost of Bearing. Nuts, Bolts and painting etc. and should meet the following requirements.
Discharge =( Q) 5.26 LPS
Total Head =( H) 196.74 Mts.
a)LWL In clear water Tank = 406.50 mtr
b) R.L. of shaft = 405.00 Mtrs.
c) R.L. of discharge Point. = 511.00 mtrs.
d) Suction lift. +tive mtrs.
e)Discharge Head = 0.0 mtrs.
f) Static Head = 104.50 mtrs.
Rising main.
Length = 3000.00 mtrs.
Diameter = 80mm. dia
Class GMS Tube (MG)
Pumping hours. 16.00 hours.
Altitude of installations above M.S.L 425 mtrs.
Characteristic of Water
a)Temperature ________Deg.Col.
b)Turbidity ________ JTU
c) Alloanity _________ mg/1 ca Co3
d)Size of solids __________ mm
e) Others.
(a) Pumps: Specifications:
i)Make
ii)Model.
iii)No.of stages:-
iv)Manufacturers
certificate to be attached.
Performance
i)Discharge:-
ii)Total Head:-
iii)B.H.P.
iv)Efficiency:
vi)Performance Curve to be attached.
b)Motors: Specifications.
i)Make
ii)Model
iii)Rating
iv)Speed.
v)Insulation.
(C) Coupling:
(d) Base Plate.
Providing ICTP Main Switch with HRC fuses of L&T/ Havells make and having capacity 30% extra of the operational rating as per IS : 13947-P I & II with upto date amendments. ICTP Switch: i) Make : ii) Type : iii) Capacity : 63 Amp.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type ) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. . Panel /Switch Board. i) Drawing.ii) layout Plan.
MCB of L&T/ Havells make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. MCB 1) Make. ii) Type iii) Range. 63 Amp. iv) Capacity
ii) ELCB of recommended make L&T / Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELCB 1) Make. ii) Type iii) Range. 63 Amp. iv) Capacity.
iii) The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition ) Volatage Monitor Relay i) Make ii ) Type iii) Range 0-500
Power factor meter of standard make as per relevent IS code with upto date ammendments. Power factor meter i) Make ii ) Type iii) Range 0-500
Frequency meter of standard make as per relevent IS code with upto date ammendments. Frequency meter i) Make ii ) Type iii) Range 0-500
d) Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ;8084-1976 and IS :11353-1985 read with BIS ; 5578 -1985 with upto date amendments including. Bus Bar Chamber i) Type ii) Make iii) Rating
Three phase indicator lamps complete with toggle switches for indivual motors as per IS 3452 ( P- I&II ) with upto date amendments. 3 phase indicators
e) Capacitor of BHEL / GEC / L&T / Mecheil make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter / IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB. Capacitor i) Type ii) Make iii) Range 6 KVAR
Providing suitable starter of L&T /BHEL make as per IS : 13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release, with or without initial oil filling as the case may be with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments. Starter i) Type ii) Make Single phase preventor i) Type ii) Make
Providing and fixing double flanged cast steel Sluice valve as per BIS 1414/API 600 with upto date ammendmnent of Kirloskar / Leader/ Kartar/ LP brand approved make for the suction pipe of 50 mm dia Class ASA 150 for the suction line of pump . Sluice Valve i)Make ii) Class ASA 150 iii)Test working head. iv) Material: Cast Steel
Providing and fixing double flanged Cast steel Sluice valve of Leader / Kirloskar/ Kartar/LP brand approved make of 50 mm dia for the delivery line of pump and capable of with standing normal Seat Pressure as per BIS 1414/API 600 with upto date ammendments. For delivery pipe of pump. 65 mm Sluice Valve i)Make ii) Class ASA 150 iii)Test working head iv) Material:-Cast Steel
Providing and fixing double flanged swing type cast steel Reflux valves of Leader/ Kirloskar/ Kartar/LP brand make of 65 mm dia Class ASA 150 for delivery line of pump and capable of with standing the normal seat pressure and as per IS: 1868/API 6D with upto date ammendments. 65 mm dia Reflux Valve i)Make ii) Class ASA 150 iii)Test working head. iv) Material:-Cast Steel
Providing and fixing double flanged swing type cast steel Reflux valves of Leader / Kirloskar/ Kartar/ LP brand approved make of 80 mm dia Class ASA 150 having by pass arrangement for the Rising main of the Pump and capable of with standing the normal seat pressure and as per IS: 1868/API 6D with upto date ammendments.Reflux Valve i)Make ii) Class ASA 150 iii)Test working head. iv) Material:-Cast Steel
Providing & fixing pressure gauge of Prega / Precision / Fiebig make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements Pressure Gauge i) Make
Installation of all items appearing as above as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and Fixing double flanged GMS piping work ( Layout to be approved by Engineer-in-Charge). for suction and delivery pipes suitable to pumps offered and common header as per the rising main respectively complete with all specials such as bends,Tees, Reducers / Inceasers with companion flanges matching with the relevant specifications of the accessories as indicated in the Drawing including rubber / asbestos gasket of 3 mm thickness as per IS : 2712-1972 and required number of Nuts and Bolts as per 1364-1983.-the pipes shall be as per relevent IS code and to withstand 1.50 times total head stipulated under item No.30.The size of various components to be as under:-
i) Suction Pipe 50 mm dia.
ii) Delivery Pipe 65 mm dia.
iii) Common Header 65 mm dia. and will extend upto 5 metres from the outer wall of the pump house in the direction of Rising main of 80 mm dia to be joined.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) Supply side from meter of HPSEB to Bus Bar and Switch i) Size 6mm2 ii) Make iii) Type iv) Capacity v) core B) Motor side (i) Size: 10.00 mm2 ii) Make: iii) Type:
Providing and fixing double loop earthing with Copper plate of 600x600x6.3mm thick electrode complete with material such as thimble, nuts and bolts, charcoal, salt,25x5mm strip as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge.. i) GI wire 6 SWG
Providing and installation of sensor based auto cut off system for dry run condition of submersible pump as per approved specification and as directed by Engineer-in-Charge
Centrifugal Pumping Machinery alongwith allied accessories for Amboa)
Providing horizontal spindle, horizontal / radial split casing /end suction ( back pull out arrangement ) Single /double /multi stage of Kirloskar / KSB/ Hindustan/ lubbi/ Groundfos Crupton KSB/Calama/BS/ make as per BIS IS 1520-1980 with upto date ammendments read with IS: 9137-1978 or latest edition suitable for lifting water for under mentioned characteristic with Bronze impellers / priming funnels, casing ring and shaft sleeves of Bronze shaft of stainless steel with cast iron casing, coupled directly through a flexible coupling on a common cast iron / cast steel base plate (base plate to be framed from the manufacturers of the pumping unit only) to slipring / Squirrel cage screen protected drip proof induction motor / motors of standard make such as Crompton / NGEF / GEC / Seimens /Jyoti/ Kirloskar BHEL / ABB suitable for operation on 415 (+/-15%) volts. 50 Cycles /Sec. 3 phase AC electric supply of 2900 RPM.The power of electric motor/ motors should be at least +10% in excess of the maximum power required by the pump / pumps in the Operation range of (+10%) and (-15%) of the duty point head. The motor / motors as per IS 325 IS -1978 with upto date amendments read with IS 900 -1972. It should include cost of Bearing. Nuts, Bolts and painting etc. and should meet the following requirements.
Discharge =( Q) 4.57 LPS
Total Head =( H) 264.77 Mts.
a)LWL In clear water Tank = 509.50 mtr
b) R.L. of shaft = 508.00 Mtrs.
c) R.L. of discharge Point. = 638.00 mtrs.
d) Suction lift. +tive mtrs.
e)Discharge Head = 0.0 mtrs.
f) Static Head = 130.00 mtrs.
Rising main.
Length = 5850.00 mtrs.
Diameter = 80 mm. dia
Class GMS Tube (MG)
Pumping hours. 16.00 hours.
Altitude of installations above M.S.L 425 mtrs.
Characteristic of Water
a)Temperature ________Deg.Col.
b)Turbidity ________ JTU
c) Alloanity _________ mg/1 ca Co3
d)Size of solids __________ mm
e) Others.
(a) Pumps: Specifications:
i)Make
ii)Model.
iii)No.of stages:-
iv)Manufacturers
certificate to be attached.
Performance
i)Discharge:-
ii)Total Head:-
iii)B.H.P.
iv)Efficiency:
vi)Performance Curve to be attached.
b)Motors: Specifications.
i)Make
ii)Model
iii)Rating
iv)Speed.
v)Insulation.
(C) Coupling:
(d) Base Plate.
Providing ICTP Main Switch with HRC fuses of L&T/ Havells make and having capacity 30% extra of the operational rating as per IS : 13947-P I & II with upto date amendments. ICTP Switch: i) Make : ii) Type : iii) Capacity : 63 Amp.
Providing MS Sheet steel fabricated floor mounted closed ( Almirah type ) switch board including angle iron post of suitable height and size ISA 40x40x6 mm duly painted with sheet of 16 gauge comprising and capable of mounting the following accessories with all internal connections. . Panel /Switch Board. i) Drawing.ii) layout Plan.
MCB of L&T/ Havells make of suitable capacity on incoming feeder with or without intial oil filling as the case may be with neutral linked under voltage releases as per IS ; 2516-1985 with upto date amendments. MCB 1) Make. ii) Type iii) Range. 63.00 Amp. iv) Capacity
ii) ELCB of recommended make L&T / Havells as per IS ; 2516-1985 with up to date ammendments and of suitable range which should have control box , operating handle & trip / reset bush button on / off of indicators, reindicating off spring condition of the circuit breaker for over current protection. The circuit should be equiped with magnet thermal release with metallic tape CTS. It should also be fitted with earth fault for tripping of breaker on occurence of Earth fault. ELCB 1) Make. ii) Type iii) Range. 63.00 Amp. iv) Capacity.
iii) The voltage monitor Relay 3 phase with all protection and usual indicator and electric siren against single phasing, low voltage, high voltage,reverse phasing,overloading and phase voltage difference as per IS; 3842 ( Latest Edition ) Volatage Monitor Relay i) Make ii ) Type iii) Range 0-500
Power factor meter of standard make as per relevent IS code with upto date ammendments. Power factor meter i) Make ii ) Type iii) Range 0-500
Frequency meter of standard make as per relevent IS code with upto date ammendments. Frequency meter i) Make ii ) Type iii) Range 0-500
d) Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS ;8084-1976 and IS :11353-1985 read with BIS ; 5578 -1985 with upto date amendments including. Bus Bar Chamber i) Type ii) Make iii) Rating
Three phase indicator lamps complete with toggle switches for indivual motors as per IS 3452 ( P- I&II ) with upto date amendments. 3 phase indicators
e) Capacitor of BHEL / GEC / L&T / Mecheil make as per IS ; 2834-1968 with upto date amendments,to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to H.P. offered including cables as per relevent ISI code ( of Seimens / Glocter / IEC make ) from bus bar chamber to capacitor as per IS : 4064-1978 with upto date amendments . Rating of capacitor will be approved by HPSEB. Capacitor i) Type ii) Make iii) Range 7.00 KVAR
Providing suitable starter of L&T /BHEL make as per IS : 13947-II with upto date 'amendments for Squirrel cage / Slipring motor mounted on panel board with magnetic type over load release and dashpot, time lag, under voltage release, with or without initial oil filling as the case may be with single phase preventor as per IS ;1248 ( P-V ) 1983 with up to date amendments. Starter i) Type ii) Make Single phase preventor i) Type ii) Make
Providing and fixing double flanged cast steel Sluice valve as per BIS 1414/API 600 with upto date ammendmnent of Kirloskar / Leader/ Kartar/ LP brand approved make for the suction pipe of 80 mm dia Class ASA 150 for the suction line of pump . Sluice Valve i)Make ii) Class ASA 150 iii)Test working head. iv) Material: Cast Steel
Providing and fixing double flanged Cast steel Sluice valve of Leader / Kirloskar/ Kartar/LP brand approved make of 80 mm dia for the delivery line of pump and capable of with standing normal Seat Pressure as per BIS 1414/API 600 with upto date ammendments. For delivery pipe of pump. 65 mm Sluice Valve i)Make ii) Class ASA 150 iii)Test working head iv) Material:-Cast Steel
Providing and fixing double flanged swing type cast steel Reflux valves of Leader/ Kirloskar/ Kartar/LP brand approved make of 80 mm dia Class ASA 150 for delivery line of pump and capable of with standing the normal seat pressure and as per IS: 1868/API 6D with upto date ammendments. 65 mm dia Reflux Valve i)Make ii) Class ASA 150 iii)Test working head. iv) Material:-Cast Steel
Providing and fixing double flanged swing type cast steel Reflux valves of Leader / Kirloskar/ Kartar/ LP brand approved make of 80 mm dia Class ASA 150 having by pass arrangement for the Rising main of the Pump and capable of with standing the normal seat pressure and as per IS: 1868/API 6D with upto date ammendments. Reflux Valve i)Make ii) Class ASA 150 iii)Test working head. iv) Material:-Cast Steel
Providing & fixing pressure gauge of Prega / Precision / Fiebig make complete with all accessories such as stop cock, copper tubing as per IS ; 3624-1987 with upto date amendements Pressure Gauge i) Make
Installation of all items appearing as above as per the systematic drawing attached with the documents or as per the direction of Engineer - in- charge.
Providing and Fixing double flanged GMS piping work ( Layout to be approved by Engineer-in-Charge). for suction and delivery pipes suitable to pumps offered and common header as per the rising main respectively complete with all specials such as bends,Tees, Reducers / Inceasers with companion flanges matching with the relevant specifications of the accessories as indicated in the Drawing including rubber / asbestos gasket of 3 mm thickness as per IS : 2712-1972 and required number of Nuts and Bolts as per 1364-1983.-the pipes shall be as per relevent IS code and to withstand 1.50 times total head stipulated under item No.30.The size of various components to be as under:-
i) Suction Pipe 50 mm dia.
ii) Delivery Pipe 65 mm dia.
iii) Common Header 65 mm dia. and will extend upto 5 metres from the outer wall of the pump house in the direction of Rising main of 80 mm dia to be joined.
Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitablle size and capacity to motors and all other electrical equipments as per IS ;1554 ( P-I ) 1988 or latest with upto date amendments of Seimen /Gloster / IEC / ICC / EICO / National / Grandlay Finolex/ Havells make including all other accessories such as thimble, flexible pipes, solder nuts and bolts,cable glands etc. laid in pipes of trenches under floor. Armoured Power Cable A) Supply side from meter of HPSEB to Bus Bar and Switch i) Size 4mm2 ii) Make iii) Type iv) Capacity v) core B) Motor side (i) Size: 10.00 mm2 ii) Make: iii) Type:
Providing and fixing double loop earthing with Copper plate of 600x600x6.3mm thick electrode complete with material such as thimble, nuts and bolts, charcoal, salt,25x5mm strip as per IS ; 3043-1987 with upto date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect as per the dirction of the Engineer - in - Charge.. i) GI wire 6 SWG
Providing and installation of sensor based auto cut off system for dry run condition of submersible pump as per approved specification and as directed by Engineer-in-Charge
Schedele B2- Civil Work
(Pump house, boundary wall, Toilet & Septic Tank) Excavation in foundation trenches upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing or pumping out water, blasting soft/hard rock or chieselling soft/ hard rock where blasting is prohibited, in all lifts including trimming and dressing of sides,levelling of beds to correct grade including,shoring,strutting, planking, timbering and dewatering wherever required,stacking the useable and unuseable material/soil separately and after laying, jointing and testing of pipes returning the useable soil in trenches in 15 cm (fiften centimeter ) layers including consolidating of such deposited layer by ramming and watering and then disposing of all surplus excavated soil /un-useable materials as directed within all leads and lifts including restoration of un-metalled surface to its original condition and including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respect within all leads and lifts as per the directions of Engineer-in-Charge.
Providing and laying cement concrete 1:6:12 ( 1 cement : 6 sand : 12 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Providing and laying cement concrete (M-10) 1:3:6 (1 cement: 3 sand : 6 crushed stone aggregate 40mm nominal size) and curing complete excluding the cost of form work in foundation and plinth including carriage of materials within all leads and lifts complete in all respect to the entire satisfaction of Engineer-in-Charge.
Randam rubble Masonary / Polygonal rubble masonary( (un coursed/ brought to courses) with hard stone of approved quality i/c levelling up at PL with cement conc. 1:6:12 in cement motor 1:6 ( 1cemet :6 Sand ) in foundation and plinth comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
1st. class brick work using common burnt clay building bricks in foundation and plinth in cement mortor 1:6 (1 cement: 6 sand ) comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Ist class brick work using common burnt clay building bricks in superstructure in cement mortor 1:6 (1 cement :6 sand) comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Providing and fixing pressed steel doors frames manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges, jump lock jamb, beed and if required angle threshold of mild steel angle of section 50X25 mm or base ties of 1.25 mm pressed mild steel welded or regidly fixed together by mechanical means, adjustable lugs with split and tails to each jamb including steel but things 2.5 mm thick with gaurds, lock strike plate and shock as specified and applying a coat of approved steel primer after pretreatment of the surfacecomlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge. a) Profile A
Providing and fixing panneled glazed or panelled and glazed shutters for doors, windows and clerestory windows,including black enamelled iron butt hinges with necessary screws. 45 mm thick.2nd class deodar wood comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centring shuttering ,strutting and propping etc.with wooden battens and ballies,height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs. and removal of the same for in situ reinforced concrete and plain concrete work in comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge. :-
Foundation footing bases of columns etc and mass concrete.
Flat surfaces such as soffits of suspended floors, roofs, landing and the like floors etc. upto 200 mm thickness within all leads and lifts complete in all respect to the entire satisfaction and as per the direction of the Engineer-in-Charge.
Edges of slab and breaking in floor and walls under 20 cm wide in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Beams,cantilivers,girders and lintels sides and soffits of beams,beam haunchings, cantilivers , girders, bressumers and lintels not exceeding 1 metre in depth.
Providing and laying cement concrete work DESIGN MIX M20 not less than 1:2:4 ( 1cement:2 sand: 4graded stone aggregate 20 mm nominal size )and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in:-
Foundation footings bases of columns and the like and mass concrete.
Suspended floors, roofs,landings and shelves and their supports, balconies, beams, girders, bressumers and cantilivers up to floor two level.
Providing tor steel reinforcement for RCC work including bending, binding and placing in position complete up to floor two levelcomlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Half brick work using common burnt clay building bricks in super structure above plinth level upto floor two level in cement mortor 1:4 ( 1 cement:4 sand ) 1st. class Brick work. comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Pointing on brick work with cement mortor 1:3 ( 1 cement: : 3 sand ) comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.Raised and cut
Providing and laying brick tiles over mumty roofs grouted with cement motor 1:3 (1 cement : 3 Sand) over a 12 mm layer of Cement Motor 1:3 (1 cement : 3 Sand) and finished neat with in all leads and lift complete.
6mm cement plaster to ceiling in CM 1:3 ( 1Cement :3 Sand) comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
15 mm cement plaster in single coat on rough side of brick/concrete stone walls for interior plastering up to floor two levels including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80 mm in girth and finished even and smooth in cement mortar 1:6 (1 cement:6 sand)comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
20 mm cement plaster in single coat on rough side of brick/concrete stone walls for interior plastering up to floor two levels including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80 mm in girth and finished even and smooth in cement mortar 1:6 (1 cement:6 sand)comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Providing & fixing M.S. grills of required pattern in wooden frame of window etc.with M.S. flats, square or round barswith round headedbolts and nuts by screws plain grills comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Providing and fixing wire gauge shutters using galvanized MS wire gauge of I.S.gauge designation 85G(eighty five ) with wire of dia 0.56 mm(zero point five six millimetre) for doors windows and clerestory windows including bright finished black enameled iron butt hinges with necessary screws 40mm(forty millimetre )thickof second class deodar wood with in all leads and lifts and as per the direction of the Engineer - in- Charge.
Boulder filling under floor dry hand packed tightly comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Providing plinth protection 50 mm thick in cement concrete 1:3:6 (1cement:3sand:6 graded stone aggregate 20 mm nominal size comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Constructing brick masonary 'U' shape open surface drain with side wall. 15 x 22 cm in cement mortar 1:6 ( 1 cement : 6 sand) and inside plastering with cement plaster 1:3 ( 1 cement : 3 sand) including earth work and laying 10 cm cement concretein 1:5:10 ( 1 cement : 5 sand :10 graded stone aggregate of 40 mm nominal size) and 7.5 cm.cement concrete 1: 2:4 ( 1cement : 2 sand : 4 graded stone aggregate 20 mm nominal size ) and finished with a floating coat of neat cement complete as per standard design.
Providing 40x3mm flat iron hold fast 40 cms long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15 cms 1:3:6 ( 1 cement :3 sand : 6 graded stone aggregate 20 mm nominal size ) complete in all respect as per the direction of the Engineer -in- Charge.
P/F MS fan clamps type 1 of 16 mm dia bar bent to shape with hooked ends in RCC slab during laying including painting the exposed portion of roof as per standard design complete in respect .
White washing with lime on undecorated wall surfaces two coats to give an even shade including thoroughly brooming the surface to remove all dirt , dust and other foreign matters comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Distempering with dry distemper of approved brand and manufacture (two coats) and of required shade on undecorated wall surfaces to give an even shade sand papered smooth comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on undecorated wall surface (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt & remains of loose powdered materials complete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Providing and fixing sliding door bolts anodized transparent or dyed to required shade and colour with screws etc. complete in all respect 300 x16 mm
Providing and fixing tower bolts barrel type anodized transport or dyed to required shade and colour with screws com lete in all respect. 200 x 10 mm
Providing and fixing aluminium handle anodized transparent or dyed to required shade and colour with screws etc. complete in all respect 100 mm
Painting two coats (excluding priming coat) on new steel and other metal surfaces with enamel paint to give an even shade including cleaning the surface of dirt ,dust and other foreign matter with enamel with enamel paint other than white complete in all respect as per the direction of the Engineer-in-Charge.
Terrazzo tiles flooring with precast terrazzo tiles 20 mm thick with marble chips of specified sizes laid in floors, treads of steps and landings on a bed of 25 mm average thickness of cement mortar 1:6 (1 cement :6 sand) jointed with neat cement slurry mixed with pigment to match the shade of tiles (wherever required) including rubbing and polishing complete with tiles grey and yellow shades medium in all leads and lifts complete in all respect to the entire satisfaction and as per the direction of the Engineer-in-Charge.
Steel work welded in built up sections,trusses and framed work including cutting hoisting fixing in position and applying a priming coat of red lead paint comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.In gratings framed gaurd bar, ladder railing brackets etc.
Providing and fixing toilet seat (Orissa Pattern) Cera make. complete in all respect as per the direction of the Engineer-in-Charge.
Providing and fixing of PVC water tank ( 500 litres) including all fittings complete in all respect as per the direction of the Engineer-in-Charge.
Providing and fixing of flushing cistern ( 5 litres) including all fittings complete in all respect as per the direction of the Engineer-in-Charge.
Providing and fixing Cast iron Manhole cover with frame having frames size of 500 mm dia with frame (Medium grade duty) weight of cover and frame to be not less than 116 Kg.
Providing and fixing sand cast/ cast iron spun spigot & socket soil waste and vent pipe 100 mm dia.complete in all respect as per the direction of the Engineer-in-Charge.
Wiring for light/Fan point /Exhaust fan point/call bell point with 1.5 .mm Sq. PVC insulated copper conductor cable in surface /recessed PVC conduit as required including carriage of materials within all leads and lifts. Group "C"
Wiring for light/power plug with 2 x 4 Sq.mm PVC insulated copper conductor or single core cable in surface/recessed steel conduit alongwith 1 No.2.24 mm dia bar copper wire for loop earthing as required including carriage of materials within all leads and lifts.
Wiring for circuit wiring with 2 x 1.5 Sq.mm PVC insulated copper conductor single core cable in surface/recessed steel conduit as required including carriage of materials within all leads and lifts.
Wiring for sub-main wiring with the following size of PVC insulated copper conductor single core cable in surface/recessed steel conduit as required including carriage of materials within all leads and lifts.2x 6mm
Supplying and fixing metal box of 180 x 100 x 60 mm deep (Nominal size) on surface/ recess with suitable size phenolic leminated sheet cover fixing 3 pin 5/6 amps socket tumber/piano type switch connective painting etc. as required (for power plug) including carriage of materials within all leads and lifts.
Supplying and fixing 32 Amps rating 240 volts, L series miniature circuit breaker of following pole in the connections testing and connections etc. including carriage of materials existing MCB DB complete within all leads and lifts. Category "A", single pole.
Supplying and fixing 40 Amps to 63 Amps rating 240 Volts "L" series miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required including carriage of materials within all leads and lifts.
Supplying and fixing of following way single pole and neutral sheet steel MCB distribution board 240 volts on surface/recessed complete with tinned copper bar neutral link earth din bar detachable gland plate interconnection including painting earthing as required including carriage of materials within all leads and lifts.
Wiring for three pin 5/6 amp. Plug point with 1.5 mm sq. PVC including copper conductor cable i/c. providing and fixing three pin 5/6 amp. Socket outlet on switch board (in surface) recessed steel conduit wiring system and 5/6 amp. Tumble /piano type switch earthing as rerquired including carriage of materials within all leads and lifts. .
Providing, installation, testing and commissioning of prewired flouroscent tube fitting complete with ballast, starter and capactors but excluding flouroscent tube rod, suitable to operate on 230 volts single phase A.C.supply directly on surface with copper wiring as required including carriage of materials within all leads and lifts tube fixture 1 x 40 watt box type category "A"
Providing / installing testing tube rods 40 watt 4" long complete in all respect..
Providing, installing, testing and commissioning of ceiling fan and regulator including wiring the rod of standard length (upto 30cm) with 1.5 Sqmm PVC insulated copper conductor single core cabe etc. as required sweep type. Cat. A (1200 mm sweep) including carriage of material complete in all respect to the entire satisfaction as per the direction of the Engineer -in- Charge.
Earthing with G.I. pipe earth, pipe 4.5 mtrs length, 40mm dia including accessories and providing masonry enclousres with cover plate having locking arrangement and watering pipe etc.( but without charcal coke and salt) complete as required including carriage of materials within all leads and lifts complete in all respect to the entire satisfaction and as per the direction of the Engineer -in- Charge.
Extra using salt and charcoal for pipe earth electrode as required, including carriage of materials within all leads and lifts complete in all respect to the entire satisfaction and as per the direction of the Engineer -in- Charge.
Supplying and laying 6 SWG G.I.wire at 0.50 mtr. below ground level for conductor earth electrode, including soldering etc. as required including carriage of materials within all leads and lifts complete in all respect to the entire satisfaction and as per the direction of the Engineer -in- Charge.
Supplying and fixing backellite batten/angle holder including connection as required including carriage of materials within all leads and lifts complete in all respect to the entire satisfaction and as per the direction of the Engineer -in- Charge.
Supplying / fixing MVL light cast aluminium control gear housing complete with accessories 125 watts BPMV lamp deep drain aluminium housing acletic cover with toggle catches with best satisfaction of the Engineer-in-Charge including connection with 40 mm G.I. Pipe 1.5 mtrs Bend (1.00 and 0.50) mtrs. including nut & screw grouted with cement in the existing MCB including carriage of materials within all leads and lifts complete in all respect to the entire satisfaction and as per the direction of the Engineer -in- Charge.
Providing and connection of bulk head fitting of all size and shape containing one No. GLS lamp holder steel wire guard and lock complete with all accessories excluding GLS lamp including connection etc. required bull head fittings Category -A-
C/O RCC Collection tank MBR and S R etc) Excavation in foundation trenches upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing or pumping out water, blasting soft/hard rock or chieselling soft/ hard rock where blasting is prohibited, in all lifts including trimming and dressing of sides,levelling of beds to correct grade including,shoring,strutting,planking,timbering and dewatering wherever required,stacking the useable and unuseable material/soil separately and after laying, jointing and testing of pipes returning the useable soil in trenches in 15 cm (fiften centimeter ) layers including consolidating of such deposited layer by ramming and watering and then disposing of all surplus excavated soil /un-useable materials as directed within all leads and lifts including restoration of un-metalled surface to its original condition and including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respect within all leads and lifts as per the directions of Engineer-in-Charge.
Providing and laying cement concrete (M-10) 1:3:6 (1 cement: 3 sand : 6 crushed stone aggregate 40mm nominal size) and curing complete excluding the cost of form work in foundation and plinth including carriage of materials within all leads and lifts complete in all respect to the entire satisfaction of Engineer-in-Charge.
Providing and laying cement concrete work DESIGN MIX M30 not less than 1:1.5:3 (1 cement: 1.5 sand :3 crushed stone aggregate 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in :-
Foundations, footings bases of columns and the like and mass concrete within all leads and lifts complete in all respect to the entire satisfaction and as per the directions of Engineer-in-Charge.
Walls (any thickness but not less than 0.10 mtrs. thickness) including attached pilasters, buttersses, plinth and string courses etc. from top of foundation level upto floor two level.
Providing form work with steel plates 3.15mm.thick welded with angle iron in frame 30x30x5mm. so as to give a fair finish including centring, shuttering, strutting and propping etc. with wooden battens and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4 Mtrs. and removal of the same for insitu-reinforced concrete & plain concrete work in :-
Vertical surfaces such as walls (any thickness) partitions and the like including attached pillasters, buttresses, plinth and string courses and the like within all leads and lifts complete in all respect to the entire satisfaction and as per the directions of Engineer-in-Charge.
Providing form work of ordinary timber plankings so as to give a rough finish including centring, shuttering, strutting and propping etc. height of propping and centring below supporting floor to ceililng not exceeding 4 metres and removal of the same for insitu reinforced concrete and plain concrete work in Arches upto 6 metres span complete in all respect to the entire satisfaction and as per the directions of Engineer-in-Charge.
Providing in RCC work smooth finishing of the exposed surface with cement mortar 1:3 (1 cement : 3 sand) complete in all respect to the entire satisfaction and as per the directions of Engineer-in-Charge.
Providing and laying cement concrete work DESIGN MIX M 25 not linear than 1:1.5:3 (1 cement: 1.5 sand :3 crushed stone aggregate 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in :-
Suspended Floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever upto floor two level complete in all respect to the entire satisfaction and as per the directions of Engineer-in-Charge.
Arches upto floor two level.
Providing Tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete upto floor two level within all leads and lifts complete in all respect to the entire satisfaction and as per the directions of Engineer-in-Charge.
Steel work welded in built up sections, trusses and framed work, including cutting, hoisting ,fixing in position and applying a priming coat of red lead paint In gratings, framed guard bars, ladders, railling, brackets and similar works within all leads and lifts complete in all respect to the entire satisfaction and as per the directions of Engineer-in-Charge. .
Fixing inlet, outlet, over flow and scour pipe of GMS pipe of following internal dia (medium grade) including extra carriage within all leads and lifts and as per directions of the Engineer-in-charge.
Inlet , Outlet and Over flow pipe 100 mm dia.(M)
Scour pipe 100 mm dia.
Providing and fixing C.I. Sluice valve (With hand wheel) as per IS -780-1984 class-I upto 300 mm dia (including brass spindle and as per IS; 2906-1984 class -II dia >300 mm) complete with nuts, rubber insertion etc. complete ( The tail piece if required shall be measured and paid fior seperately ) PN 1.0
Over flow pipe 100 mm dia
Over flow & Scour pipe 100 mm dia.
Constructing chamber for sluice valve, with CI surface box 100 mm top dia.,160 mm bottom dia and 180 mm deep (inside) with chained lid RCC top 1:2:4 mix (1 cement : 2 sand :4 graded stone aggregate 20 mm nominal size) 100 mm thick foundation concrete 1:5:10 mix (1cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortor 1 :3 (1 cement : 3 sand) finished with a floating coat of neat cement including curing complete. 600 x 600 x 750 mm inside size with 150 mm thick walls of RCC 1:2 :4 (1 cement :2 sand :4 graded stone aggregate 20 mm nominal size) complete with form work and reinforcement with 6 mm bars at not exceeding 150 mm centres both ways within all leads and lifts complete in all respect to the entire satisfaction and as per the directions of Engineer-in-Charge. .
Providing and fixing Cast iron Manhole cover with frame having frames size of 500 mm dia with frame (Medium grade duty) weight of cover and frame to be not less than 116 Kg.
C/O OHSR tank 20 Mtrs. Staging height MBR ) Excavation in foundation trenches upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing or pumping out water, blasting soft/hard rock or chieselling soft/ hard rock where blasting is prohibited, in all lifts including trimming and dressing of sides,levelling of beds to correct grade including,shoring,strutting,planking,timbering and dewatering wherever required,stacking the useable and unuseable material/soil separately and after laying, jointing and testing of pipes returning the useable soil in trenches in 15 cm (fiften centimeter ) layers including consolidating of such deposited layer by ramming and watering and then disposing of all surplus excavated soil /un-useable materials as directed within all leads and lifts including restoration of un-metalled surface to its original condition and including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respect within all leads and lifts as per the directions of Engineer-in-Charge.
Providing and laying cement concrete (M-10) 1:3:6 (1 cement: 3 sand : 6 crushed stone aggregate 40mm nominal size) and curing complete excluding the cost of form work in foundation and plinth including carriage of materials within all leads and lifts complete in all respect to the entire satisfaction of Engineer-in-Charge.
Providing and laying cement concrete work DESIGN MIX M30 not linear than 1:1.5:3 (1 cement: 1.5 sand :3 crushed stone aggregate 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in :-
Foundations, footings bases of columns and the like and mass concrete within all leads and lifts complete in all respect to the entire satisfaction and as per the directions of Engineer-in-Charge.
Columns, pillars posts and struts upto all heights.
Lintels, beams, girders, bressumers and cantilevers upto all heights.
Stair cases (except spiral stair cases) excluding landing but including preparing of the surface and finishing of nosing upto all heights.
Arches upto floor two level.
Suspended Floor, roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever upto floor two level within all leads and lifts complete in all respect to the entire satisfaction as per the directions of Engineer-in-Charge .
Walls (any thickness but not less than 0.10 mtrs. thickness) including attached pilasters, buttersses, plinth and string courses etc. from top of foundation level.
Providing form work with steel plates 3.15mm.thick welded with angle iron in frame 30x30x5mm. so as to give a fair finish including centring, shuttering, strutting and propping etc. with wooden battens and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4 Mtrs. and removal of the same for insitu-reinforced concrete & plain concrete work in all leads and lifts complete in all respect to the entire satisfaction as per the directions of Engineer in -Charge :-
Foundation, footings and basis of columns etc. and mass concrete within all lead and lifts complete in all respect to the entire satisfaction as per the directions of the Engineer-in-Charge..
Columns, pillars, posts and struts Circular or curved in plan upto all heights.
Sides and soffits of beams, beam haunchings, cantilevers, bressumers and lintels not exceeding 1 Mtr. in depth in all heights from floors.
Vertical surfaces such as walls (any thickness) partitions and the like including attached pillasters, buttresses, plinth and string courses and the like.
Flat surfaces such as soffits of suspended floors, roofs, landing and the like floors etc. upto 200 mm thickness within all leads and lifts complete in all respect to the entire satisfaction and as per the direction of the Engineer-in-Charge.
Stair cases with sloping or stepped soffits excluding landing upto all heights..
Providing form work of ordinary timber plankings so as to give a rough finish including centring, shuttering, strutting and propping etc. height of propping and centring below supporting floor to ceililng not exceeding 4 metres and removal of the same for insitu reinforced concrete and plain concrete work in Arches upto 6 metres span complete in all respect to the entire satisfaction and as per the direction of the Engineer-in-Charge.
Steel work welded in built up sections, trusses and framed work, including cutting, hoisting ,fixing in position and applying a priming coat of red lead paint In gratings, framed guard bars, ladders, railling, brackets and similar works within all leads and lifts complete in all respect to the entire satisfaction and as per the direction of the Engineer-in-Charge.
Providing tor steel reinforcement for RCC work including bending, binding and placing in position complete in all respect including carriage of materials within all leads and lifts complete in all respect to the entire satisfaction and as per the direction of the Engineer-in-Charge.
Providing plinth protection 50mm thick in cement concrete 1:3:6 (1 Cement : 3 Sand : 6 graded stone aggregated 20mm nominal size) including carriage of materials complete in all respect to the entire satisfaction and as per the direction of the Engineer-in-Charge.
Providing under layer for plinth protection of 75mm thick (unconsolidated) bed dry brick/stone aggregated 40mm nominal size with rammed and consolidated and grouted with fine sand including preparation of ground complete in all respect to the entire satisfaction and as per the direction of the Engineer-in-Charge..
Providing and fixing MS manhole cover of 500 mm dia with frame (Medium grade duty) weight of cover and frame to be not less than 116 Kg.
Fixing inlet, outlet, over flow and scour pipe of GMS flanged pipe of following internal dia (medium grade) including extra carriage within all leads and lifts complete in all respect to the entire satisfaction and as per the direction of the Engineer-in-Charge..
Inlet Rising Main 100 mm dia.
Outlet pipe 100 mm dia (Distribution)
Over flow & Scour pipe 100 mm dia.
Providing, fixing and welding of MS flanges confirming to BIS code 6392-1971 table -5 below noted diameter (Latest with upto date ammendments) Welding of M.S. flanges on G.I. Pipe on both ends according to relevant BIS standard and detailed technical specifications) and provided with nuts and bolts of required size complete. within all leads and lifts complete in all respect to the entire satisfaction and as per the direction of the Engineer-in-Charge..
Inlet Rising Main 100 mm dia.
Outlet pipe 100 mm dia (Distribution)
Over flow & Scour pipe 100 mm dia.
Providing and fixing full way wheel valve (With hand wheel) as per IS -780 class for following dia (including brass spindle and as per IS; 2906 class -II including M.S. Flanges, bolts, nuts, rubber insertion etc. complete in all respects including carriage of material within all leads and lifts.
Outlet pipe 100 mm dia (Distribution)
Scour pipe 100 mm dia.
Providing and fixing of water measuring gauge of standards design complete in all respect to the entire satisfaction and as per the direction of the Engineer-in-Charge..
Providing and fixing of sky lightening arrestor complete in all respect in all leads and lifts complete in all respect to the entire satisfaction and as per the direction of the Engineer-in-Charge..
Providing and fixing of vent opening including cowl with mesh in the top of the tank complete in all respect complete in all respect to the entire satisfaction and as per the direction of the Engineer-in-Charge..
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on undecorated wall surface (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt & remains of loose powdered materials complete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Construction of cholorination Room for installation of gaseous plant at MBRs.
Excavation in foundation trenches upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing or pumping out water, blasting soft/hard rock or chieselling soft/ hard rock where blasting is prohibited, in all lifts including trimming and dressing of sides,levelling of beds to correct grade including,shoring,strutting,planking,timbering and dewatering wherever required,stacking the useable and unuseable material/soil separately and after laying, jointing and testing of pipes returning the useable soil in trenches in 15 cm (fiften centimeter ) layers including consolidating of such deposited layer by ramming and watering and then disposing of all surplus excavated soil /un-useable materials as directed within all leads and lifts including restoration of un-metalled surface to its original condition and including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respect within all leads and lifts as per the directions of Engineer-in-Charge.
Providing and laying cement concrete 1:6:12 ( 1 cement : 6 sand : 12 graded stone aggregate 40 mm nominal size) and curing complete excluding the cost of form work in foundation and plinth comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge..
Squarred rubble stone masonary coursed with hard stone of approved quality in foundation and plinth in retaining walls/breast wall including racking out joint in cement mortar 1:6(1cement:6sand) as per direction and to the entire satisfaction of Engineer-in-charge.
Providing and laying damp proof course 38mm thick with cement concrete 1:2:4 (1cement:2sand:4 graded stone aggregate 20 mm nominal size and curing complete in all leads and lifts.
Ist class brick work using common burnt clay building bricks in superstructure in cement mortor 1:6 (1 cement :6 sand) comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Providing and fixing pressed steel doors frames manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges, jump lock jamb, beed and if required angle threshold of mild steel angle of section 50X25 mm or base ties of 1.25 mm pressed mild steel welded or regidly fixed together by mechanical means, adjustable lugs with split and tails to each jamb including steel but things 2.5 mm thick with gaurds, lock strike plate and shock as specified and applying a coat of approved steel primer after pretreatment of the surfacecomlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.a) Profile A
Providing and fixing panneled glazed or panelled and glazed shutters for doors, windows and clerestory windows,including black enamelled iron butt hinges with necessary screws. 45 mm thick.2nd class deodar wood comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Providing and laying cement concrete work DESIGN MIX M20 not less than 1:2:4 ( 1cement:2 sand: 4graded stone aggregate 20 mm nominal size )and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in:-
Suspended floors, roofs,landings and shelves and their supports, balconies, beams, girders, bressumers and cantilivers up to floor two level. in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Providing & laying cement concreteM- 30 (not leaner than 1:1.5:3) mix concrete using aggregate 20 mm nominal size) & curing complete excluding the cost of form work & reinforcement for reinforced concrete work in wall
Providing form work with steel plates 3.15 mm thick welded with angle iron in frame 30x30x5mm,so as to give a fair finish i/c centring shuttering,strutting & propping etc. with wooden battens & ballies,ht. of propping & centring below supporting floor to ceiling not exceeding 4.00 mts. & removal of the same for in situ-reinforced concrete & plain concrete work :-
Flat surface such as soffits of suspended floors,roofs,landing and the like floor etc.upto 200mm I thickness as per the direction of the Engineer-in-Charge.
Edges of slab and breaking in floor and walls under 20 cm wide in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
15 mm cement plaster in single coat on rough side of brick/concrete stone walls for interior plastering up to floor two levels including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80 mm in girth and finished even and smooth in cement mortar 1:6 (1 cement:6 sand)comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Cement concrete flooring 1:2:4 (1 cement : 2 sand :4 graded stone aggregate 20 mm nominal size) laid in one layer finished with a floating of neat cement comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.40 mm thick
Providing plinth protection 50 mm thick in cement concrete 1:3:6 (1cement:3sand:6 graded stone aggregate 20 mm nominal size comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
6mm cement plaster to ceiling in CM 1:3 ( 1Cement :3 Sand) comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Providing plinth protection 50 mm thick in cement concrete 1:3:6 (1cement:3sand:6 graded stone aggregate 20 mm nominal size comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Providing tor steel reinforcement for RCC work including bending, binding and placing in position complete up to floor two levelcomlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Boulder filling under floor dry hand packed tightly comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Applying two coat of wood preservative coat on new wood and wood based surface after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign sand papering and knotting in all lead and lift
Applying priming coat on new wood and wood based surfaces after and including preparing the surface by thoroughly cleaning oil,greese,dirt and other foreign matters,sand papering and knotting.Ready mixed paint brushing wood primer pink comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Painting two coats (excluding priming coat) on new wood and wood based surfaces,with enamel paint to give an even shade including cleaningthe surface of dirt ,dust and other foreign matters sand papering and stopping with enamel paint other than white comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
White washing with lime on undecorated wall surfaces two coats to give an even shade including thoroughly brooming the surface to remove all dirt , dust and other foreign matters comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Providing 40x3mm flat iron hold fast 40 cms long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15 cms 1:3:6 ( 1 cement :3 sand : 6 graded stone aggregate 20 mm nominal size ) complete in all respect as per the direction of the Engineer -in- Charge.
Providing and fixing sliding door bolts anodized transparent or dyed to required shade and colour with screws etc. complete in all respect 250x16mm
Providing and fixing tower bolts barrel type anodized transport or dyed to required shade and colour with screws com lete in all respect. 200x10mm
Prvoviding Fixing M.S handle with necessary screwsetc.completein all respect 100mm
Providing and fixing M.S fan clamp (Type-1) of 16mm dia.M.S including end upto shape with broken end in RCC .Slab door painting the exposed position of trapall as per standard design complete in all lead and lifts.
Providing & fixing M.S. grills of required pattern in wooden frame of window etc.with M.S. flats, square or round barswith round headedbolts and nuts by screws plain grills comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
Providing /fixing wiring for Cholorination Room.
Wiring for light / Fan point / Exhaust fan point / call bell point with 1.5 Sq.mm PVC insulated copper conductor cable in surface/recessed PVc conduct at required including of all material within all leads and lifts.
Wiring for light / power plug with 2 x 4 Sq.mm PVC insulated copper conductor or single core cable in surface/ recessed steel conduit alongwith 1 No.2.24 mm dia bare copper wire for loop earthing as required including carriage of materials within all leads and lifts.
Wiring for Circuit wiring with 2 x 1.5 Sqm.mm PVC insulated copper conductor single core cable in surface/rcessed steel conduit as required including carrige of material upto all leads and lifts. 2 x 6 Sq.mm
Wiring for sub-main wiring with the following size of copper conductor single core cable in surface/ recessed steel conduit as required including carriage of materials upto all leads and lifts.
Supplying and fixing metal box of 150 x 100 x 60mm deep (Nominal size) on surface/ recess with suitable size phonolic laminated sheet cover fixing 3 pim 15/16 amps socket tumber/piano type switch connections painting etc. inculding carriage of materials within all leads and lifts.
Supplying and fixing 32 Amps rating 240 volts, L series miniature circuit breaker of following pole in the connections testing and connections etc. including carriage of materials existing MCB DB complete within all leads and lifts. Category "A", single pole.
Supplying and fixing 40 Amps to 63 Amps rating 240 Volts "L" series miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required including carriage of materials within all leads and lifts.
Supplying and fixing of following way single pole and neutral sheet steel MCB distribution board 240 volts on surface/recessed complete with tinned copper bar neutral link earth din bar detachable gland plate interconnection including painting earthing as required including carriage of materials within all leads and lifts.
Wiring for three pin 5/6 amp. Plug point with 1.5 mm sq. PVC including copper conductor cable i/c. providing and fixing three pin 5/6 amp. Socket outlet on switch board (in surface) recessed steel conduit wiring system and 5/6 amp. Tumble /piano type switch earthing as rerquired including carriage of materials within all leads and lifts. .
Providing, installation, testing and commissioning of prewired flouroscent tube fitting complete with ballast, starter and capactors but excluding flouroscent tube rod, suitable to operate on 230 volts single phase A.C.supply directly on surface with copper wiring as required including carriage of materials within all leads and lifts tube fixture 1 x 40 watt box type category "A"
Providing / installing testing tube rods 40 watt 4" long complete in all respect..
Providing, installing, testing and commissioning of ceiling fan and regulator including wiring the rod of standard length (upto 30cm) with 1.5 Sqmm PVC insulated copper conductor single core cabe etc. as required sweep type. Cat. A (1200 mm sweep) including carriage of material complete in all respect to the entire satisfaction as per the direction of the Engineer -in- Charge.
Earthing with G.I. pipe earth, pipe 4.5 mtrs length, 40mm dia including accessories and providing masonry enclousres with cover plate having locking arrangement and watering pipe etc.( but without charcal coke and salt) complete as required including carriage of materials within all leads and lifts complete in all respect to the entire satisfaction and as per the direction of the Engineer -in- Charge.
Extra using salt and charcoal for pipe earth electrode as required, including carriage of materials within all leads and lifts complete in all respect to the entire satisfaction and as per the direction of the Engineer -in- Charge.
Supplying and laying 6 SWG G.I.wire at 0.50 mtr. below ground level for conductor earth electrode, including soldering etc. as required including carriage of materials within all leads and lifts complete in all respect to the entire satisfaction and as per the direction of the Engineer -in- Charge.
Supplying and fixing backellite batten/angle holder including connection as required including carriage of materials within all leads and lifts complete in all respect to the entire satisfaction and as per the direction of the Engineer -in- Charge.
Supplying / fixing MVL light cast aluminium control gear housing complete with accessories 125 watts BPMV lamp deep drain aluminium housing acletic cover with toggle catches with best satisfaction of the Engineer-in-Charge including connection with 40 mm G.I. Pipe 1.5 mtrs Bend (1.00 and 0.50) mtrs. including nut & screw grouted with cement in the existing MCB including carriage of materials within all leads and lifts complete in all respect to the entire satisfaction and as per the direction of the Engineer -in- Charge.
Providing and connection of bulk head fitting of all size and shape containing one No. GLS lamp holder steel wire guard and lock complete with all accessories excluding GLS lamp including connection etc. required bull head fittings Category -A-
Supply and errection of chlorine gas plant
Supply, installation commissioning and testing of vacuum operated, pressure feed gaseous chlorinator/ Jasco/ Capital for chlorinator of water by direct feeding to existing water main consisting of the following and all as specified.
Cholrinator capable to deliver 0-2500 gm/hour of chlorine gas comprising of spring opposed inlet valve, rate valve, flow meter remote ejector assembly with build in check valve, vaccum tubing, vent tubing and injection assembly. Set of 2 No. : 1W+ IS
Booster pump set BE/NF with electirc motor CROMPTON/ KIRLOSKAR/ ABB operated on 400/440 volts, 3 phase 50 HP electric supply to suit ejector assembly of chlorinator, mounted on common base frame and starter and making foundation in PCC 1:3:6 for booster pump. Set of 2 No. : 1W+ IS
Water piping from water main to booster pump and delivery of water to elector through 25mm dia G.I pipe medium grade complete with all fittings such as 25mm inlet gate valve, 25mm delivery valve, Y type stainer 25mm heavy duty PVC Plumbing pipe Sch. 80 upto injection point before ejector assy/piping upto delivery mains.
Assessories / spares:- Multi purpose cylinder Key-1 No. lead washers -6 Nos. Ejector gasket-2 sets. Hose clips- 4 Nos. Ammomia Bottle - 50 ml -1 No.
Chlorine Gas cylinder 100 kg capaciaty duly approved by CCE Nagpur and filled with Chlorine gas.
Chlorine analyzer to indicate chlorine content level in the chlorinated water to supply.
Safety item covering Chlorine leak emergency kit 1 No. self contained breathing apparatus 1 No. and eye shower - 1 No.
Erection and commissioning charge.
Schedule B3-Gravity mains and Distribution system:-
Excavation in foundation trenches upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing or pumping out water, blasting soft/hard rock or chieselling soft/ hard rock where blasting is prohibited, in all lifts including trimming and dressing of sides,levelling of beds to correct grade including,shoring,strutting,planking,timbering and dewatering wherever required,stacking the useable and unuseable material/soil separately and after laying, jointing and testing of pipes returning the useable soil in trenches in 15 cm (fiften centimeter ) layers including consolidating of such deposited layer by ramming and watering and then disposing of all surplus excavated soil /un-useable materials as directed within all leads and lifts including restoration of un-metalled surface to its original condition and including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respect within all leads and lifts as per the directions of Engineer-in-Charge.
Laying, jointing and testing in trenches GMS pipes (light grade/Medium grade) confirming to ISI specification including commissioning and cost of all fittings in respect of following diameters in gravity mains/distribution system (earth work in trenches to be measured and paid for separately) including entire carriage of material comlete in all respect including all leads and lifts as per the direction of the Engineer-in-Charge.
32 mm dia (L).
40 mm dia (L).
50 mm dia (L).
65 mm dia (L).
80 mm dia (L).
100 mm dia (L).
Dismentling of old GMS pipe in existing distribution system where changing is required of following diameters including staking of material at site in all leads & lift and as per the direction of Engineer-in-Charge.
15mm dia (L).
20mm dia (L).
25mm dia. (L).
32 mm dia (L).
40mm dia (L).
50mm dia (L).
65 mm dia. (L).
100 mm dia. (L).
Relaying of old serviceable GMS pipe of following diameters in all leads & lift and as per the direction of Engineer-in-Charge.
32 mm dia (L).
40mm dia (L).
50mm dia (L).
65 mm dia. (L).
100 mm dia. (L).
Providing and fixing of brass full way valves for water works purpose as per 778-1984 (reaffirmed-2010) of the following diameters in distribution system including entire carriage of material in all leads and lifts as per the direction of the Engineer- in-Charge.
32 mm dia
40 mm dia
Providing and fixing C.I sluice valve of approved (with hand wheel ) as per IS 780 class upto 300 mm dia including brass spindle and as per IS- 2906 class II for diameter more than 300 mm complete with bolts,nuts,insertion etc.( The tail pieces if required shall be measured and paid for separately.) within all leads & lifts. PN 1.0 LEADER / KIRLOSKAR MAKE
50 mm dia.
65 mm dia.
80 mm dia
100 mm dia
125 mm dia
SCHEDULE B4 Providing and Fixing PLC based Automation System & Solar Plant
Providing and Fixing PLC based Automation System &MCC panels for pumps
Providing and Fixing Automation System considering the micrologix 1400 basd PLC system having following instruments
Ultrasonic Level Transmitter . Measuring Range :4 Mtrs. Make :SBEM/Emerson / Mobery =2Nos.
Pressure Transmeter Make: Emerson/Yokogawa =2Nos
Insertion Magnetic Flow Meter Make: George Fisher/Emerson/SBEM. =2Nos
Butterfly Valve Line Size: 80 mm & 65 mm Make: Belimo/Mascon/Geroge Fisher =2Nos
Pressure SwitchMake: Switzer/Indfos =2Nos
GPRS Facilities installation & Activation. =2Nos
UPS & Distribution boxes =2Nos
Earthing =2Nos
Suitable cables in required length =2Nos
Providing and Fixing Solar Plant
Providing and installation of solar track stand dusk to dawn automatic opertation with 1 KM Panel Complete reputed make System with 1500VA Solar Inverter, 2x150 AH Solar Battery, 4x270 watts Solar Panels, GI Structure including complete Accessories as per standard . Inculding ,Tax ,Transporttation, Installation complete in all respects.
SCHEDULE B5 Operation and Maintenance of Scheme for 3 years:-
Operation and maintenance of Scheme from source to main/ sector storage tank gravity main, distribution mains, rising mains etc. and to keep all structure/ machinery/ facility to proper working O&M includes the regular i.e daily supplying of designed / required quantity of potable water having water quality as per of water Supply to the beneficiaries of the scheme up to main storage /delivery tank from above mentioned source to main/ sector storage tanks at different location as per plan and repair and maintenance of main lines, gravity lines and entire distribution mains of scheme, regular maintenance of all the facilities i/c cleaning washing oil and greasing repair, replacement of worn out / damaged parts of pumping Machinery, pipe lines valves and electrical mechanical requirements regular cleaning of all structure like collection tank, storage tank, pump house etc. and disposal of same as per the direction of Engineer-in-Charge. Fixing / repairing leakage in civil structure, pipe line, pumping machinery etc proper distribution of treated water and regular testing of water samples. Maintaining log book of running of pumping machinery register for sample reports and consumption of chemicals keeping regular and proper record of water quantity and quality, repair and maintenance work chemical dosing and time and hours of run of pumping machinery removed of all kind of slips, slush, up-rooting of unwanted grass, shrub, weeds etc growing near the structure and keeping the area neat and clean to the entire satisfaction of Engineer-in-Charge. Planting and maintenance of plants, flowers, tree around the pump House and storage tank etc to the entire satisfaction of Engineer-in-Charge, i/c the cost of procurement of adequate and proper tools and plants, Skilled and unskilled manpower spare parts, oil/ grease/ lubricants, chemicals for water treatment and all kinds of regents required for water samples testing and making standby arrangement all time . Instruments, equipments, stationery and any other material etc. required for O&M excluding the cost of energy charges. All the operation shall be carried out as per the CPHEEO manual of water Supply and treatment (latest addition) HPPWD/ JSV specification Hp & JSV norms direction issued by the Engineer-in-Charge from time to time and sound engineering practice.
The O&M part will commence from date of completion of successful trial & test run 3 month period after physical completion of all components.
Operation & maintenance for Ist year
Operation & maintenance for 2nd year
Operation & maintenance for 3rd year
Deepak Kumar Beetan
BACHITTAR SINGH AND CO
malkiat singh govt cont
Unipro Techno Infrastructure Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .