Garrison Engineer (East) Prayagraj
Stanley Road, Teliyarganj, Prayagraj
Preventive maint and servicing of DG sets, E/M Equipments of STP, Security lights etc and servicing of Vehicles at Varanasi cant under GE (East) Prayagraj.
2024_MES_666676_1
8753/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Varanasi
As Per NIT
6 documents required · 6 mandatory
₹500
GE (East) Prayagraj
₹97,640
Yes
11 Jan 2025
19 Jul 2024
28 Sept 2024
19 Jul 2024
21 Sept 2024
2 Aug 2024
19 Jul 2024 - 26 Jul 2024
Amount
Taking out non clog sewage submersible pump including electric motor of capacity 10HP & 20 HP, 3 phase, 415 Volts, disconnecting all electrical & machanical connection, dismantling the motor and pump, cutting out the burnt/old/unservecible moulded winding, cleaning the slots with non greasy materials, replacing with moulded copper reassembling pump & motor after making it serviceable by means of repair/ rewinding of pump or motor or both and lowering/ fixing in its orignal position and testing complete all as specified and directed. Note:-(i) The cost of bush & necessary T&P required for taking out, dismantling and lowering deemed to be included in quoted rates. (ii) Parts required for replacement or rewinding of motors shall be paid seperatly under respective item. (iii) The contractor shall carryout the functionality/ serviceable test of submersible pump & motors before and after the lowering . Cost of the same shall deemed to be included in quoted rates. (iv) Cost of transportation if any shall also deemed to be included in the qupted rates. (v) If the winding of motor is burnt and needs rewinding, then burnt winding shall be cut in the presence of GE/AGE concern.
S&F in repair for following parts to be replaced under item No. 01 above:-
Winding of motor, 10 HP, 3 phase 415 boths with and included super enamelled copper winding wire with 'F' class insulation
Winding of motor, 20HP, 3 phase 415 boths with and included super enamelled copper winding wire with 'F' class insulation
Bearing of suitable for 10 HP motor
Bearing of suitable for 20 HP motor
Impeller mechine seal for10HP motor
Impeller mechine seal for 20 HP motor
Repair/Servicing of air compressor fo capacity 600 cum/hrs by replacement of liner assembly, rings, gaskets, polishing alignment of cam /pully drive shaft, groove key, etc. and refixing in the same position properly including necessary testing for smooth and vibration free running complete all as specified and directed. Note:- Part replaced sahll be included in quoted rate.
M&L for taking out Induction electric motor 20/25 HP, 3 phase ,415 Volts after disconnecting all electrical , transporting to workshop & machanical connection including dismantling the motor, cutting the burnt/old/unservecible winding and cleaning the slots with non greasy materials and replacing with super enamelled copper winding wire of existing guage including repalcement of unserviceable parts such as DE and NDE bearing, fan blade and reassembling and refixing on the foundation and testing after making all electric connection complete all as specified and directed.
M&L for taking out Induction electric motor 7.5/10 HP, 3 phase ,415 Volts, disconnecting all electrical & machanical connection, dismantling the motor, cleaning the slots with non greasy materials and replacing with super enamelled copper winding wire of existing guage including repalcement of unserviceable parts such as DE and NDE bearing, fan blade and reassembling and refixing on the foundation and testing after making all electric connection complete all as specified and directed.
Taking out centrifugal pump suitable for 7.5/10 HP, 3 phase, 415 Volts after dismantling all the connection and transporting to workshop for repairing pump by replacing with and including unserveciable parts and reinstalling in true alignment, making all electrical and machenical and testing complete all as specified and directed. Note:- Parts required for replacement or rewinding of motors shall be paid seperatly under respective item.
S&F in repair for following part to be replaced in above item:-
Bearing of size upto 7.5 HP
Bearing of size upto10 HP
Bush of size upto 7.5 HP
Bush of size upto 10 HP
Impeller of size upto 7.5 HP
Impeller of size upto10 HP
Gland packing
Gland -I bolts
MS Coupling
Star coupling
water seal
gasket
studs
M&L desludging of existing underground sewage collecting sump of 12.0M dia and depth upto 10mtr & getting out sludge by means of sucking THROUGH supper soucer machine and depositing/desposing out side MD land at isolated plcaes, painting the internal/external surface of sump with two coats of apoxy cement base paint including preparing all the surface before painting complete all as specified and directed. Note for Item No- All equipment required to clean all sumps shall be arranged by the contractor and rates deemed to be inclusive in the unit quoted rates.
M&L for pumping and desludging of existing sewage bioreactor semi underground sump of size 12mx10m x10m & getting out sludge through sucking supper soucer machine and depositing/desposing out side MD land at isolated plcaes,painting the internal/external surface of sump with two coats of apoxy cement base paint including preparing all the surface before painting complete all as specified and directed.
M&L desluding/cleaning of existing slude from fillter beds of size 5 x 5 m and depth 0.80 by any means ie manually or by using mechanical appliances complete, removing the sludge /vegetation out side Cantt area and deposited the same where directed by Engineer-in-Charge and supply & spreading of river washed dry course red sand, top layer of filter bed 150mm thick, painting the walls/channel with two coats of apoxy cement base paint including preparing of exposed surface complete all as specified and directed.
M&L for taking out and cleaning media from MBBR tank of STP (area not exceeding 25 Sqm, depth note exceeding 5.0m), keeping aside for reuse after cleaning and desluding/dewatering of existing MBBR tank (any Nos. of partitions) by any means (mechanical/ manually) complete, removing the sludge to the out side of MOD land in sealed container, painting the internal/external surface of sump with two coats of apoxy cement base paint including preparing of surface complete all as specified and directed. Note :(i) The cost of all T&P and fuel, etc. required for excution of job deemed to be included in the quoted rates. (ii) The work may be executed in foul conditions. Contract may consider this aspect while quoted rates.
M&L for Desluding/dewatering tube settler tank of sewage treatment plant (size 4.0 x 4.0 m and depth not exceeding 5.0 mtr) by any means cleaning with fresh water, includes M&L for painting the external and exposed surface of sump with two coats of apoxy cement base paint including preparing of surface complete all as specified and directed.
M&L for Desluding/dewatering chlorine contact tank of sewage treatment plant (size 3m x3mx 3m) cleaning with fresh water, includes M&L for painting the external and exposed surface of sump with two coats of apoxy cement base paint over a coat of primer including preparing of surface before painting complete all as specified and directed. .
M&L for Disludging/dewatering of TWT tank of sewage treatment plant (Size 6.0mtr Dia and depth not exceeding 8 mtr) including painting the internal/external and exposed surface of sump with two coats of apoxy cement base including preparing of surface before painting complete all as specified and directed.
Supply and filling aerobic attached growth non clogging randomly moving bed bio reactor MBBR media (fluidised aerobic bed, as per sample) chemical resistent suitable for sewage treatment including removing deformed & worn out media complete all as specified & directed.
M&L for preparation of old painted steel surfaces (such as angel iron frame, sheets, water filters, pipelines, mild steel ladders, railing, Column pipes any size) at STP of any width or girth and painting with one coat of synthetic enamel paint (Total surface area 220 sqm approx) complete all as specified and directed.
M&L in repair for CI/DI fittings bends ( any type of radius and angle) Tapers any type of straight bends, increasing , decreasing or double socket etc. Tees , Pieces , single branch ,Y junctions , double branch , cross ( all sockets or socket and spigot ) collars, Clamps, Caps and plugs upto 150mm bore pipe complete all as specified and directed.
M&L in repair of 40 mm bore cast iron butter fly stop valve, including material and labour for joints, replacement of rubber/ fibre joints gasket 2 Nos and nut, bolts , washers in repairs length as per existing butter fly valve complete all as specified and directed by Engineer-in-charge
M&L in repair of 80 mm bore cast iron butter fly stop valve, including material and labour for joints, replacement of rubber/ fibre joints gasket 2 Nos and nut, bolts , washers in repairs length as per existing butter fly valve complete all as specified and directed by Engineer-in-charge
S&F in repair MCCB, 63Amp 3 pole, 16kA 415 volts, 50Hz including Outgoing and incoming Cable Connection, fixing to existing Panel Board MCCB complete all as specified and directed.
S&F in repair MCCB, 100Amp 3 pole, 16kA 415 volts, 50Hz including Outgoing and incoming Cable Connection, fixing to existing Panel Board complete all as specified and directed.
S&F in repair MCCB, 200Amp 4 pole, 16kA 415 volts, 50Hz including Outgoing and incoming Cable Connection, fixing to existing Panel Board complete all as specified and directed.
Supply & Fix 3 Pole Power Contactor MNX 9 having coil 240V, 50/50 Hz AC3 Rating, up to 500 V including taking down old U/S complete all as specified and directed. Make: L&T
Supply & Fix 3 Pole Power Contactor MNX 32 having coil 240V, 50/50 Hz AC3 Rating, up to 500 V including taking down old U/S complete all as specified and directed. Make: L&T
Supply & Fix 3 Pole Power Contactor MNX 40 having coil 240V, 50/50 Hz AC3 Rating, up to 500 V including taking down old U/S complete all as specified and directed. Make: L&T
Supply & Fix 2 Pole Add-on Block MNX-A2 having coil 240V, 50/50 Hz AC3 Rating, up to 415 V including taking down old U/S complete all as specified and directed. Make: L&T
Supply & Fix 4 Pole Add-on Block MNX-A1 having coil 240V, 50/50 Hz AC3 Rating, up to 415 V including taking down old U/S complete all as specified and directed. Make: L&T
S&F Panel relay 3 phase 415 V MNF of range as suitable for 5 to 20 HP motor complete all as specified and directed.
S&F Panel connector 2/4 pole 3 phase 415 V of range as suitable for 5 to 20 HP motor complete all as specified and directed.
Supply and mixing water disinfectant containing 65-70% chlorine contents (calcuim based granular disinfectant for water treatment, packed in 45 Kg plastic drum of approved make complete all as specified and directed.
Supply and mixing Poly Aluminium Chloride (PAC 01) Grade 29% for water treatment plant, packed in plastic drum/PE bags of make as approved by GE complete all as specified and directed and by engr-in-charge.
Supply and mixing white Polyelectrolyte (PE) powder Cationic/Anionic for water treatment plant, packed in plastic drum/PE bags of make as approved by GE complete all as specified and directed and by engr-in-charge.
Supply and mixing water disinfectant containing 6 to 10% chlorine contents (Hypo Chloride liquid disinfectant for sewage treatment) complete all as specified and directed and by engr-in-charge.
Supply and mixing Aluminum sulfate (Alum) suitable for flocculation as specified & directed by engineer in charge
Taking down chemical dosing pump, single phase 230Volts 50 Hzs of capacity 1.5 gln to 4.75 glns/hrs suitable for 70 mtr head range complete all as specified and directed.
S&F in repair for following part in item:-
FRP tank of existing cap
SS agitator shaft including motor
Skid/tank mounted
Pump maint kit
Level switch
Flow control valve
Control panel
S&F in repair fan belt (anti static oil & heat resistant) suitable for Air compressor 600 M³/hr including connection complete all as specified and directed.
S&F in repair pressure gauge (water) range 0-10 Kg/Sqcm complete all as specified and directed.
M&L for taking out old unserviceable compressor oil and filling with new compressor oil upto the required level as recommended by manufacturer complete all as specified and directed.
S&F in repair, EDGE LED street light new generation energy saving & environmental friendly long life versatile pressure die- cast aluminium IP66 LED street light fitting 90 watts on pole including MS brackets and 1.5Sqmm 3 core PVC unsheathed copper cable connected to existing junction box etc, complete all as specified and directed.
S&F in repair LED type phase indicator lamp (RYB) suitable for complete all as specified and directed.
S&F in repair of push button red/green including connection suitable for LT panel complete all as specified and directed.
S&F in repair premium quality crush and kink resistance PVC flexible water pipe 20mm dia in 30 mtr roll complete all as specified and directed.
S&F in repair, Star coupling (R-150) , Heavy Duty, Styrene Butadiene Rubber suitable for coupling of 10/15 HP pump and motor, complete all as specified and directed.
S&F in repair heavy duty MS coupling suitable for 50mm dia shaft with key groove including MS key of suitable size complete all as specified and directed.
S&F in repair carbon steel nut bolts/washers/ foundation bolts of any size complete all as specified and directed.
Repair/servicing of 40 to 125 KVA diesel engine/ generator set installed at pump house including repalcement of old unserviceable part as required including trasporting to workshop for any repair work complete all as specified and directed. Note - Spare part shall be measured and paid separately under respective item only.
Taking out old unserviceable self starter of DG Set 40 to 125 KVA, trasporting to workshop for repairing of self starter including replacement of field coil/stator coil and rotor/bush as required, fixing and necessary testing after repairing, complete all as specified and directed.
S&F in repair fuel pipe for DG set of required size (upto 5 RM) complete all as specified and directed.
Calibration of fuel pump of DG Set 40 to 125 KVA including transporting to authorised workshop and replacement of 'O' ring, refixing and testing the same after repair, complete all as specified and directed.
Cleaning/ servicing of fuel tank of DG set, painted with two coats of synthetic anamel paint on external surface after preparing, including, dismantlng of fule tank and refixing in same position, drain out the fule from tank, complete all as specified and directed.
S&F in repair fuel filter primary/secondary of DG Set 40 to 125 KVA as required complete all as specified and directed.
S&F in repair Oil filter of DG set 40 to 125 KVA as required complete all as specified and directed.
Supply and replace air filter oil bath type suitable for 40 to 62.5 KVA DG Set complete all as specified and directed.
Supply and replace air filter paper impregrated type suitable for 40 to 125 KVA complete all as specified and directed.
S&F in repair exhaust manifold lether gasket as required for DG set 40 to 125 KVA complete all as specified and directed.
Supply and replace coolent complete all as specified and directed.
M&L for taking out old unservice radiator assembly of DG set 40 to 125 KVA and transporting to authorised workshop for cleaning/de scaling and repair work of soldering/brazing as required including replacement of lid and gasket and refixing the same at site complete all as specified and directed.
S&F in repair old unserviceable led acid batter of cap 12V, 180 AH complete all as specified and directed.
Supply and replacement of Battery Charger sutable for charging of Battery 12/24 Volt including connecting wires with crocodile clips heavy duty complete all as specified and directed.
S&F in repair PVC insulated copper conductor wire 10 Sqmm 900mm long (2 Nos) for battery lead with heavy duty brass battery terminals and lugs on both cables complete all as specified and directed.
S&F in repair ignition switch for DG set complete all as specified and directed.
S&F in repair of AVR (as per sampal) suitable for DG Set 40 to 125 KVA capacity including connections, complete all as specified and directed.
Opening the engine head, taking out the unserviceable block and liner assembly of DG set 40 to 62.5 KVA, transporting to workshop/authorise dealer for replacement of piston block, rings, liner assembly and all gaskets including testing commissioning complete all as specified and directed.
Opening the engine head and taking out the unserviceable block and liner assembly of DG set 125 KVA and transporting to workshop/authorise dealer for replacement of piston block, rings and liner assembly all gaskets including testing commissioning complete all as specified and directed.
S&F in repair door Hinges with Nut & Bolts (as per sample) suitable for DG set 40 to 125 KVA Capacity, complete all as specified and directed.
Taking out old unserviceable three phase 415V alternator 40/62.5 KVA, transporting to the workshop for repair, rewinding with super enamelled copper conductor of exising guage and refixing the same including testing commission, complete all as required at site.
Taking out old unserviceable three phase 415V alternator 125 KVA, transporting to the workshop for repair, rewinding with super enamelled copper conductor of exising guage and refixing the same including testing commission, complete all as required at site.
S&F in repair change over switch three phase 415 Volts 200A capacity front operating rotary handle inlcluding making all electrical connections with proper lugs complete all as specified and directed.
S&F in repair change over switch three phase 415 Volts 125A capacity front operating rotary handle inlcluding making all electrical connections with proper lugs complete all as specified and directed.
Taking down existing non functional security/ street light fittings from pole/ wall/ pipe of any type of LED fitting of any wattage for repairing including replacement/ unserviceable accessories like SPD, LED Driver etc & refixing the same with & including connecting cable of 3 core PVC sheathed Aluminium conductor not less than 4 Sqmm from light fitting to cable looping box & tightening of brackets, clamp by nut, bolts and washer including testing, complete all as specified and directed. NOTE : (i) Replacement and fixing of unserviceable component etc required will be measured & paid separately under respective items of this schedule as S&F in repair here under. (ii) Fitting shall be connected with existing electric wire / cable, in case of existing wire / cable found unserviceable same shall be measured and paid in relevent items. (iii) Any type of Ladder or arrangement for dismantling of light from pole/ hanger pole shall be arranged by the contractor.
S&F in repair service cable un armoured of size 4 sqmm 2 core,1100 volts grade,heavy duty cable with PVC insulated solid aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed including taking down old/ unserviceble service wire complete all as specified and directed. of Make -Finolex/Plaza/Havells
S&F in repair service cable un armoured of size 6 sqmm 2 core,1100 volts grade,heavy duty cable with PVC insulated solid aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed including taking down old/ unserviceble service wire complete all as specified and directed. of Make -Finolex/Plaza/Havells
S&F in repair service cable un armoured of size 10 sqmm 2 core,1100 volts grade,heavy duty cable with PVC insulated solid aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed including taking down old/ unserviceble service wire complete all as specified and directed. Make -Finolex/Plaza/Havells
S&F in repair surge protection device 10 KV, suitable for LED street lights of capacity 45 watt to 250 watts, single phase, 230 volt, 50 Hz, AC supply complete all as specified and directed.
S&F in repair LED street light/Flood light fitting driver/ choke 36/40/45/60 watts, 240 volts AC 50 Hz electronic type. Make -Havells Cat Part No-LSSCRX2208 Or equivalent in Bajaj/C&S/C&G
S&F in repair LED light fitting driver/ choke 70/75 watts, 240 volts AC 50 Hz electronic type. Make - Philips cat Part No-X075C070V107FNY1CO/ Crompton & Greaves/Havells/Bajaj/ C&S/C&G
S&F in repair LED street light/Flood light fitting driver/ choke 90 watts, 240 volts AC 50 Hz electronic type. Make - Crompton & Greaves /Philips / Havells Cat Part-NI2PRIOPBCP1SN040/065V2100_02 / Bajaj / C&S/C&G
S&F in repair LED street light driver/ choke 25/30 watts, 240 volts AC 50 Hz electronic type. Make - Crompton & Greaves/ Philips / Havells / Bajaj/C&S/C&G
Supply and fix in repair LED street light luminaires 25 watt with pressure die cast aluminium housing with heat resistant toughned glass and IP66 protection complete including connection on pole or building including taking down of old /unserviceble street light fitting complete all as specified and directed. Make- Crompton Greaves cat No- LSTO-25- CDL ,Havell- LHETAXU7UN6W024, Orient -LSFS-025-CF-PC
Supply and fix in repair LED street light luminaires 35 watt with pressure die cast aluminium housing with heat resistant toughned glass and IP66 protection complete including connection on pole or building including taking down of old /unserviceble street light fitting complete all as specified and directed. Make- Crompton Greaves cat No- LSTO-35- CDL Or Equivalent make in Havells/Bajaj
Supply and fix in repair LED street light luminaires 60 watt with pressure die cast aluminium housing with heat resistant toughned glass and IP66 protection complete including connection on pole or building including taking down of old /unserviceble street light fitting complete all as specified and directed. Make- Crompton Greaves cat No- LSTO-60- CDL Havell- LHETAXU7PN6J060
Supply and fix in repair LED street light luminaires 90 watt with pressure aluminium -die- cast powder coating housing & frame with heat resistant,high efficiency toughned glass with EPDM gasket for IP66 protection complete assembly with LED ,driver& accessories pre-wiredup to terminal block including connection on pole or building including taking down of old /unserviceble street light fitting complete all as specified and directed. Make- Crompton Greaves cat No- LSTO-90- CDL Havell- LHETAXU7IN6J090,C&S-LTESS40X2.5HPLED/LS
M&L for GI bracket for security light & street light fittings fabricated with GI tubing 40 mm dia 'medium grade 1.2 m long including and bending to angle of 120 degree fixed in repair complete all as specified and directed.
M&L for mild steel clamp fabricated with mild steel flat iron 50 x 6 mm including nut and bolts with washer suitable for fixing of GI bracket on PCC/ steel poles fixed in repair complete all as specified and directed.
Taking down & dismentaling existing old street light GI pipe with clamp & fixing/relocating on another height/pole all as specified and directed by Engr-in-charge.
Supply and fix in repair for hot press moulded PVC junction box of size 230mm x 170 mm x105 mm with 200A TPN Aluminium bus bars mounted/fixed on porcelien insulator shock and rust proof,cable entry from bottom and other sides,100% weatherproof, with pole mounting arrengement temperproof,fire retardant class FV-0 as per IS 11731 part -II or V-O as per UL-94 including flat iron clamp of size 25 x 3 mm with nut and bolt complete all as specified and directed.
Supply and fix in repair Electronic street light Astronomical control timer switch, operating automatic/ mannually with sheet metal encloser box wall/pole mounting type including heavy duty clamp made out of mild steel sheet 3.15 mm thick duly painted with two coat of synthetic enameled paint over a coat of red oxide primer of capacity 6 KW,Conforms to IS/IEC 60947-4-1, 3 phase, 415/230 volts, 50 Hz, ISI marked suitable to accommodate the following including taking down existing feeder box :- (a) Three phase control switch MCB TPN 40A 10 KA - 01 No (Incoming) (b Auto/Manual control switch (c) Heavy duty 3 Phase Contactor ML-3 with axulllary contact - 01 No (d) sun light senser cat eye type complete to operate before sun rise & after sun set (d) Astronomical Timer - 01 No. Make - Havells cat Part No - IHXTS0306A or equivalent make in L&T,Legrand
Suply and fix in repair energy saving LED garden light fitting,decorative,bollard of capacity 10 watt with opal diffuser &aluminium reflector complete with all accessaries and fixing arrengement on PCC block of size 45mm X 45 mm alogwith fixing nuts,bolts and PVC insulated aluminium conductor,stranded type of size 4.0 sqmm,2 -core including taking down old/unserviceble garden light fittings any type and wattage all as directed.
Supply and errection of steel tubular pole swaged type 410-SP 31(9.0m long pole) as per IS:2713 (part I to III) 1980 complete with cast iron base plate, pole cap, mild steel bolt, nuts and screws complete including dismantling of exsiting pole all as specified including consisting of following works:- (a) Excavation in trenches not exceeding 1.5 mtr wide & 1.57 mtr deep for pole foundation & getting out in soft/loose soil, returning filling in the excavated of soil after fixing the pole in foundation ramming earth around in layer not exceeding 25 cm thick and disposal of surplus soil to a distance not exceeding 50 mtrs complete all as specified and directed. (b) M&L for PCC 1:4:6, type D2 (using 40mm graded crushed stone aggregate) in foundation 900mmx600mm cross section and planting depth 1.5 mtr for concrete encasing the pole upto GL complete all as specified and directed.
Contd/... (c) M&L for providing PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) for plinth block/collar above GL 500mm high and 450mm dia complete all as specified and directed. (d) M&L for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminium paint over a coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto the height of 1.5mm above plinth block. (e) M&L for writing letter or figures (Block Roman, Italic as Indian) with thick synthetic enamel paint of apprised shade not exceeding 5 cm height including numbering of pole complete all as specified and directed. NOTE : Manufacture's test certificate will be produced before execution work. MAKE : National tuubing Co Kanpur or BCW Kanpur or M/s Sohan Lal & Sons or United Engineers, Kanpur.
Taking down existing non functional high mast/semi High mast pole light any type/wattage for repair including replacement of unserviceable spares/accessories like ballast, starters, ignitors, lamps, service connection etc & errecting the same after cleaning & greasing of SWR rope in position after complete repair and testing all as specified and directed. NOTE : (i) Replacement and fixing of unserviceable component etc required will be measured & paid separately under respective items of this schedule. (ii) Fitting shall be connected with existing electric wire / cable, in case of existing wire / cable found unserviceable same shall be measured and paid in relevent items. (iii) Any type of Ladder or arrangement for dismantling of light from pole/hanger/high mast pole shall be arranged by the contractor.
M & L for Rewinding of motor with super enameled copper wire of high mast light any type (gauge/weight of copper coils shall be same as per existing dismantled motor strata), including varnishing complete all as specified and directed by Engineer-in-Charge. Notes :- (a) removing the defective motor & rectifying after repair including removing defective parts, burnt winding carefully, cleaning & re-assembling the motor after repair/servicing including oiling, greasing etc.complete to the entire satisfaction of Engineer-in-charge.
S&F in repair PVC insulated & FR PVC round stranded sheathed conductor copper multi core round ( flexible)industrial cable 1100 volt with bright concealed electrolytic bare copper conductor for voltage 1100 volts grade of size 16 sqmm,4 core confirming to IS-694-1990 including taking down old/unserviceble cable any type from semi high/high mast poles of any height and connecting complete all as specified and directed.
S&F in repair PVC insulated & FR PVC round stranded sheathed conductor copper multi core round ( flexible)industrial cable 1100 volt with brightannealed electrolytic bare copper conductor for voltage 1100 volts grade of size 10 sqmm,4 core confirming to IS-694-1990 including taking down old/unserviceble cable any type from semi high/high mast poles of any height and connecting complete all as specified and directed.
Supply and fix in repair LED integral flood light luminaires 170 watt in powder coated with aluminium die cast housing and frame,high efficiency,long life LEDs,loop in loop out connector,10 A G.F.P for each wiring heat resistant toughned lear glass cover and IP 66 protection complete assembly with LEDs,driver and accessaries pre wired up to terminal block in control gear compartment including connection on pole or building including taking down of old /unserviceble HPSV/MH street light fitting any type & wattage complete all as specified and directed. Make- Wipro cat No-LR18-971-XX-57-XX,Havells- LHEPCZU7P46J150,C&S-LTESS10X2.5HPLED
Supply and fix in repair LED integral flood light luminaires 120 watt in powder coated with aluminium die cast housing and frame,high efficiency,long life LEDs,loop in loop out connector,10 A G.F.P for each wiring heat resistant toughned lear glass cover and IP 66 protection completeassembly with LEDs,driver and accessaries pre wired up to terminal block in control gear compartment including connection on pole or building including taking down of old /unserviceble street light fitting complete all as specified and directed. Make- Wipro cat No-LR18-971-XX-57-XX,C&S- LTEFI120WHPLED,Havells-LHEPCZU7P46J120
Supply and fix in repair LED integral flood light luminaires 200 watt in powder coated with aluminium die cast housing and frame,high efficiency,long life LEDs,loop in loop out connector,10 A G.F.P for each wiring heat resistant toughned glass in the front with unique flood optics to ensure uniform distribution and IP 66 protection complete assembly with LEDs,driver and accessaries pre wired up to terminal block including connection on pole including taking down of old /unserviceble light fitting complete all as specified and directed.
S&F in repair under water luminiaries 7 watt LED light for connecting under water lighting purpose of fountain, Corrosion resistant, Nickel plated brass housing, water proof with flanges of top coloured glass with rubber gasket on both sides , mounted in brass frame with all accessiories and LED complete all as specified and directed..
Excavation in trenches in soft/loose soil not exceeding 1.5 M wide and not exceeding 1.5 Mtr deep and getting out including filling bottom surface to required level or slope for laying of pipes/ cables complete all as specified and directed.
Returning filling including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft soil complete all as specified and directed.
Removing excavated surplus soil not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
M&L for sand cushioning with dry local sand for cable protecting under ground cable (8 cm before laying the cable and 15 cm after laying the cable) in trenches including punning the sand upto 18 cm thick and consolidated complete all as specified and directed. Note : Punned thickness 18 cm shall be measured only.
Supply and laying dry well burnt locally available brick sub class 'B' modular bricks laid flat with width equal to the length of whole bricks over cable as cable protection complete all as specified and directed.
M & L for bore hole for passing cable through / insertion of 80/50mm dia GI pipe under PCC road/ taxi track/ runway/ hard standing upto the depth 450mm to 1200 mm complete all as directed by Engineer-in-charge. NOTES :- (i) Cost of equipments, tools & plants,material required for boring shall be deemed to be included in unit quoted rates above. (ii) GI pipe 80/50 mm dia shall be measured and paid separetely.
S &F for 32 mm dia GI pipe 'light grade' ISI marked including fittings such as bends, tees, sockets etc fixed on wall/pole or laid in trenches under road crossing/hard standing including taking down old /unserveciable existing pipe complete all as specified and directed. NOTE : Excavation and earth work shall be measured & paid separately.
S &F for 50 mm dia GI pipe 'light grade' ISI marked including fittings such as bends, tees, sockets etc fixed on wall/pole or laid in trenches under road crossing/hard standing including taking out old /unserveciable existing pipe complete all as specified and directed. NOTE : Excavation and earth work shall be measured & paid separately.
Supplying ,laying, commissioning & testing 16 Sqmm, 4.0 core XLPE cable insulated armoured, electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductor including taking down old / unserveciable existing cable complete all as specified & directed. Note: Excavation & earth work, sand cushioning & Bricks shall be measured & paid separately under respective item of BoQ.
Supplying ,laying, commissioning & testing 10 Sqmm , 4 core XLPE cable insulated armoured, electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductor including taking down old / unserveciable existing cable complete all as specified & directed. Note: Excavation & earth work, sand cushioning & Bricks shall be measured & paid separately under respective item of BoQ.
Supplying ,laying, commissioning & testing 10 Sqmm , 2 core XLPE cable insulated armoured, electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductor including taking down old / unserveciable existing cable complete all as specified & directed. Note: Excavation & earth work, sand cushioning & Bricks shall be measured & paid separately under respective item of BoQ.
Supplying ,laying, commissioning & testing 6 Sqmm , 2 core XLPE cable insulated armoured, electric power cables (heavy duty) 1100 Volts grade with standard aluminium conductor including taking down old / unserveciable existing cable complete all as specified & directed. Note: Excavation & earth work, sand cushioning & Bricks shall be measured & paid separately under respective item of BoQ.
M&L for taking electric shutdown and employing labour competent to climb on trees for maintenance and trimming of tree branches touching to overhaul bare electric condutor lines/ electric installation upto the clearance of 2 mtr all around and removing the garbage and deposting when and where directed all as specified. Note- Required labours as decided by Engr-in-Charge with proper safety kit and cuttings tools, ledder, electric saw/generator set,wire rope etc shall be provided by the contractor and rates are deemed to be included the quoted rates.
M&L for Demolition of brick work or stone masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings dressed stonework and precast concrete articles complete all as specified & directed.
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified & directed.
Taking down cement plaster on brick or stone wall etc including racking out joints hacking for key scrubbing down with water etc complete all as specified & directed.
M&L Rendering 15 mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces, finished even and smooth complete all as specified and directed.
M&L Rendering 10 mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces, finished even and smooth complete all as specfied and directed.
M&L preparing new plastered or unplastered surfaces of walls and applying two coats of Oil bound distemper smooth wall finish in approved colour/shade over a coat of primer over wall care putty after preparation of surfaces complete all as specified and directed .
M&L for Preparing new plastered or unplastered surfaces of walls and applying two coats of cement base paint smooth wall finish in approved colour/shade over a coat of primer over wall care putty after preparation of surfaces complete all as specified and directed.
M&L for Preparation of new or previously untreated steel surface of any description exc 10cm with or girth an applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thick M-35 grade with grey cement and pigment over sand cushion complete all as specified & directed.
M&L for sand filling under floors including spreading and levelling in layers n.exc 50mm thick complete all as specified & directed.
M&L for cement concrete type B0 1:2:4 (12.5 mm graded stone aggregate) as in copings cills and the similar items including weathering, slightly rounded or chamfered angles & throating as directed.
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
M & L for 25mm thick Cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate in levelling course, benching etc, finished even & rough to receive cement mortar screed bed complete all as specified & directed.
M & L for 75mm thick Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in levelling course,for floor benching etc, finished even & rough to receive cement mortar screed bed complete all as specified & directed.
M&L for carrying out general periodical servicing and checking of the complete engine / transmission system / suspension system / exhaust system /cooling system / Electrical system and braking sysytem complete along carring out wheel Rotation /Alignment along with greasing of wheel bearings and rectify for the minior complaints defects as per manufacturer recommendation / including replacement of required necessary minor spares such as nut,bolts, fuses and Replacement of diesel / Petrol Fuel filter (Primary and secondary) and Engine oil filter complete sets along with 'o' rings, new nuts and washers and cleaning of air filters/ breather,Radiator tank with Blower and labour for filling/topping up and Replacement of Engine oil /coolant / brake oil and tuning and testing of engine under ideal load conditions for vehicles all as specified and directed Note: (i) Rate Quoted includes the cost of minor acessories such as nuts and bolts 'O' rings and all fuel/lube filters (ii) Engine Oil and Coolant , air filter,Diesel filter spark plugs shall be measured and paid under relevant Item. (iii) Major Unserviceable items shall be measured and paid under relevant Item.
Tata 3.04L Dicor/Xenon
Bajaj Platina
Hero Honda Splendor
Taking down the existing defective Self starter from TATA Mobile Vehicle and replacement of work out spares like Bendex drive, carbon brush, solinoid coil, Armature including rewinding stator, refixing in same position and testing complete all as specified and directed by the Engineer-in-charge.
Taking down the existing defective Alternator from TATA Mobile Vehicle and replacement of work out spares like Rotor Coil, Field coil, Rectifier, Electronic regulator/Carbon brush with Holder, refixing in same position and testing complete all as specified and directed by the Engineer-in-charge.
M&L for repair/replacement of TATA Mobile defective suspension system and checking of parts such as shock absorber, front spring leaf, centre bolt, front spring leaf hanger, front spring leaf, shackle pin, rear spring leaf, rear spring leaf hanger, rear shackle pin and replacement of following unserviceable parts including testing and complete all as specified and directed by engineer-in-charge. Note : The rate for the minor parts required for repair is deem to be included in the quoted rate
M&L for taking down the existing defective fuel injection pump (FIP) alongwith injector for the Eicher and replacement of worn out spares like delivery valves, Nozzles, bearings, fly weight, packing kit, and copper washer kit and recalibration of FIP alongwith governor and refixing in same position and testing of full load checking of pressure and checking the solinoid coil etc complete all as specified and directed by the Engineer-in-charge.
M & L in replacement for Cover outer 700 x16 with tube inner suitable for TATA 207/Xenon including tube inner for 7.00 x 16 make: Ceat /MRF
Transporting any class of goods (i.e. Diesel, Pertrol, Engine Oil, Furniture chlorine, B&R and E&M stores, water supply accesories and electric complaints etc) by any means at any location in the entire AOR of Old Cantt and Fort Cantt under GE (East) Prayagraj in first shift from 10.00 hrs to 18.00 hrs Note : The cost of fuel driver etc shall deemed to be included in quoted unit rates
Strip opening of the vehile along with engine for over haul, of veh TATA 207/ TATA Xenon and segrigating of servicable / unservicable parts and refixing of servicable parts after cleaning including servicing and greasing complete and replacing the unserviceable spares parts complete all as specified and testing of vehicle after repair for satisfaction of Engineer-in -Charge. Note:- Spare parts shall deemed to be included in unit quoted rates.
M/s A.K Construction (BID ID -3097023)
Avion Industries (BID ID -3104371)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .