PROVISION OF FALSE CEILING AND LED LIGHTS AT CERTAIN TECH AREA BLDGS AND CERTAIN REVENUE AND MINOR WORKS IN TECH AREA AT AFA HYDERABAD
2021_MES_411168_1
8131/14/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AFA) Hyderabad
As per Tender Documents
5 documents required · 5 mandatory
₹500
Yes
GE (AFA) Hyderabad
₹47,000
Yes
25 Feb 2021
9 Jan 2021
6 Feb 2021
9 Jan 2021
4 Feb 2021
22 Jan 2021
9 Jan 2021 - 21 Jan 2021
Amount
M&L Armstrong Ceiling Classic Lite 16mm 600x600mm, NRC-0.55, grid size Main Tee 32x24mm,cross Tee of 1200mm of size 27x24 mm and cross tee of 600mm of size 25x24mm and wall angle of size 19x19mm and fixed alround the wall to form a grid of size 600x600mm. Tiles shall be inserted in the formed grid and suspended with 2mm GI wire at every 1200mm intervals C/c complete all as specified and as directed.
M&L for preparing old wall surfaces and applying one coat of oil emulsion distemper all as specified and directed
Excavating in trenchs, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in Soft/Loose soil all as specified and directed
M&L for PCC (1:4:8 ) type D2 (using 40mm graded stone aggregates) in foundations, filling , mass concrete etc complete all as specified and directed
S&F 1000 ltrs capacity rotational moulded double layered polyethlene water storage tank (cylindirical vertical with close top) hoisted and fixed in position all as specified in SSR Part I and as directed
S&F 25 mm bore Galvanized steel tubes, medium grade including necessary fittings like Tees, bends,elbows etc . fixed to walls, ceillings or laid in floors or in trenches all as specified and directed
S&F 20 mm bore Galvanized steel tubes, medium grade including necessary fittings like Tees,bends,elbows etc fixed to walls, ceillings or laid in floors or in trenches all as specified and directed
S & F 25mm dia Ball brass Valves, high pressure, with polythene float and fly nut complete, screwed for Iron pipe or brass ferrule all as specified and directed.
S & F 20mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed all as specified and directed
Removing excavated material ( soil) to a distance n.exc 50m and depositing where directed at a level n exc.1.5m above the starting point all as specified and directed.
M&L for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors including all fittings etc ; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or FE 310-0 complete all as specified and directed.
S&F mild steel small article works as in hold fasts, bands, straps, etc quality conforming to Fe-290 Gde-E-165 complete all as specified and directed
M&L for mild steel plates, plain or chequered, 5mm thick or over in thickness conforming to Fe-290 Gde-E-165 all as specified and directed.
M&L for Preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise provided and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as described.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in hard/dense soil complete all as specified and directed by Engr-in-Charge.
M&L for Cement concrete in PCC (1:2:4 )type B2 using with 40 mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
S&Fof Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 all as specified and directed
S&F Rolled mild steel in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc ,Fe-410-W(Gde-E-250) quality 'A' all as specified and directed
S&F Pre painted galuvalume aluminium zinc coating GI based corrugated sheet 0.5mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall with self tapping screws complete all as specified and as directed.
S&F Pre painted galvalume aluminium zinc coating GI based plain sheet 0.5mm thick of any colour having tensle strength of 550Mpa as in roof covering/cladding to wall with self tapping screws complete all as specified and as directed.
Roughening surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc all as specified and directed
M&L for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in CM 1:4 Type B1 1:2:4 (20 mm graded stone aggregate) complete all as specified and directed.
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and includng mild steel annealed wire not less than 0.9mm dia all as specified and directed
M&L for Precast Reinforced cement concrete (1:2:4) with Type B1 using 20mm graded stone aggregate as in Slabs shelves,manhole covers,drains cover and the like supported on walls all as specified and directed
M&L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of newly plastered wall surfaces and applying 3 coats of cement based paint complete all as specified.
S & F of 2mm thick Linoleum sheet, plain coloured, laid dry in floors including preparation, stretching, cutting and fitting sealed down with approved adhesive etc complete all as specified and as directed.
Cutting holes in brick walls exceeding one bricks but not execeeding two bricks for inserting holdfast and making good dismantled portion in Cement mortar 1:3 or Cement concrete 1:2:4 etc complete all as specified and directed
Surface excavation in hard/dense soil n exc 30 cm thick and average 15 cm thick complete all as specified and as directed.
M&L for MS plates Fe 410 - W Gde E250 quality A in roof trusses (framed)trussed, etc connecting with bolts/welding as base plates/connecting plates etc complete all as specified and as directed.
M&L for MS screw bolts and nuts made with hexagonal or square headed one end and screwed the other and to be fitted with washer and one nut exc 22.5 cm n exc 30 cm long complete all as specified and as directed.
M&L hardcore of broken stone or boulders gauge n.exc 63 mm, deposited, spreaded,and leveled in layers n exc 15 cm thick watered and well ramed to true surface complete all as specified and as directed
M&L for 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate in sub base complete all as specified and as directed
M&L for 75 mm thick PCC 1:2:4 type B-2 using 40 mm graded stone aggregate in floors finishing surface even and smooth with out using extra cement complete all as specified and as directed
Removing excavated material (soil) to a distance exc 250m but n exe 500m and depositing where directed at a level n.exc 1.5 m above the starting point all as specified and directed.
M&L for glass dividing strips 3 mm thick & 28 mm width inserted in position in floors complete all as specified anddirected
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and removing rubbish off the premishes all as specified and directed
M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including screed bed in CM(1:6) 15mm thick all as specified and directed
M&L Glazed ceramic tiles 7 to 8 mm thick (square/rectangular)area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in vertical surfaces of skirting,dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including backing coat in CM (1:4) 10 mm thick all as specified and directed
Taking down chowkats or frames with shutters n exc 1.5 Sqm each (without taking off shutters from the frame) complete all as directed.
S & F powder coated aluminium window shutters and frame, fixed type or sliding type two track without sash bars, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips ,rubber packing, anodised aluminium snap beading screws etc.complete all as specified. (Powder coating should not be less than 50 micron). Note: Glazing shall be measured separately
M & L 5.5 mm thick sheet glass, of any colour ordinary quality in square exc 0.5 sqm in each pane complete all as specified and as directed.
M&L for Point wiring complete with 1.5 sqmm single core FRLS grade 1100 V PVC insulated unsheathed wire with multi stranded copper conductor drawn through in and including PVC non metalic conduit not less than 20 mm dia and accessories ISI marked fixed surface on wall / ceiling/ roof etc and including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS ISI marked as earth continuity conductor, fabricated steel terminal box madeout of 1.60mm thick MS sheet concealed in walls with 3mm thick bake lite sheet (Hylqm or equalant) top cover with chromium plated screws and cup washers for housing the switches, socket outlets, fan regulator etc, complete all as specified for:-
(a) One fan point / light point controlled by one piano switch
S&F switch piano flush button single pole one way 5 Amp complete all as specified.
S&F for Ceiling rose, PVC/polycarbonate, insulated body, 3 terminals and 240 Volts ISI marked complete all as directed
S & F DB with sheet metal enclosure 240 volts, 4 way Single phase double door with copper bus bar neutral link, earth link, earthing studs, without MCBs complete. Distribution Board shall be fitted out side of the explosive store complete all as directed.
S & F MCB SPN of 240 Volts, AC, 50 Hz of capacity 6-32 Amp 10 KA complete all as specified and directed.
S & F MCB 'C' series SP 6-32 Amps rating, 10 KA breaking capacity, 240V, 50Hz, AC supply, complete all as specified and directed.
S & F high efficiency '2X2' recess mounting LED light fitting 40 wattas with glare free homogeneous illumination including LED driver with all accessories internally pre-wired, connecting up with three core twisted flexible copper conductor cable complete all as specified and directed by Engineer-in-Charge. Make : Lucker cat No- LKM2240 or equivalent of Havells / Phillips / Bajaj / CG
S & F for Sub Main wiring with 2 runs of FRLS grade 1100 volt unsheathed PVC insulated cable of single core 4 sq mm (nominal area) multi-stranded copper conductor drawn through and including non metalic PVC conduit not less than 20 dia (ISI marked) incl all specials like joint elbow, Tee, junction , bend etc and provision of one run of FRLS grade 1100 V rated PVC insulated multistranded copper conductor single core 4sq mm for earth continuity all as directed.
Note (I): Necessary M.S junction boxes for inspection as required on site/directed by Engr-in-charge, shall deemed to be included in the quoted rate.
(II) Three runs of wire and one run of conduit with necessary accessories will be measured as one unit length.
(III) The wiring shall be done strictly by following proper colour coding as per IS
Saiansh Associates
M/S NAVEEN BUILDERS
sri ram construction
S J REDDY
M/s RAMA LAKSHMI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .