Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical 13 1 BABA DEEP SINGH NAGAR JALANDHAR PUNJAB 144012 | 144012 | Admitted-Fee/PreQual/Technical |
Tender Value
Refer Docs
EMD Value
₹9,763
Closing Date
24 Aug 2026, 3:00 pmClosed
Director
Dr.B.R.Ambedkar NIT, Jalandhar
Shifting and reinstallation, testing and commissioning of Street Light Poles at NIT, Jalandhar
2026_NITJ_919998_1
NITJ/EO/Works/Elect/06/26
Open Tender
Electrical Works
Works
60 days
Dr. B.R.Ambedkar NIT
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Director
₹9,763
25 Aug 2026
3 Aug 2026
25 Aug 2026
3 Aug 2026
24 Aug 2026
3 Aug 2026
3 Aug 2026 - 17 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Shifting and reinstallation testing and commissioning of street light poles at NIT Jalandhar | |||||
| 1.01 | Shifting, Reinstallation, testing and commissioning of Existing old Above 8.0 Meter and upto 10.0 Meter height G.I. pole of different diameter duly reinforced i/c Construction of 1:3:6 RCC round foundation (radius of 0.5 mtr and height of 1.5 mtr) (1 cement : 3 corese sand: 6 graded stone aggregate 20 mm nominal size), and circular collar of size radius 0.25 and height 0.75 mtr (1 cement : 3 corese sand: 6 graded stone aggregate 20 mm nominal size) including providing suitable size DWC pipe for crossing of cable of suitable length as per foundation size with necessary bending for cable entry including finishing and two coats of exterior paint/outer finish as approve by the engineer in charge, complete i/c interconnections of existing cables, shifting and re-laying of cables as per site requirement etc. as required. | 14 | each | 100 | ₹1,400 |
| 1.02 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm | 220 | mtr | 100 | ₹22,000 |
| 1.03 | Supplying and Fixing of wheather proof Pole/ Wall mounted Enclosure of size 255 x 255 x 122mm deep dust and weather proof with front openable complete with 02 no. of locking arrangement and 2 Nos. M.S. Clamps i/.c Pdg. & fixing of 1 No. 16 Amp 'C' Series SP MCB mounted on din bar, 2 Nos. 20mm x 5mm thick Al. Strip, Holes for incoming & outgoing connections as required | 14 | each | 100 | ₹1,400 |
| 1.04 | Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of 1.1 KV grade Conforming to IS 7908 (Part 1) 1988 with upto date ammendment of following size in the existing RCC/HUME/METAL pipe/ HDPE pipe / Open in air etc. as required. 4x10 sq mm | 280 | mtr | 100 | ₹28,000 |
| 1.05 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) | 250 | Mtr | 100 | ₹25,000 |
| 1.06 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4x10 sqmm (25 mm) | 28 | each | 100 | ₹2,800 |
| 1.07 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. | 280 | Mtr | 100 | ₹28,000 |
| 1.08 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an event shade: Two or more quotes on new workover an under coat of suitable shade with ordinary paint of approved brand and manufacture.
Note :- To be painted on old poles before shifting on new foundation. | 75 | sqm | 100 | ₹7,500 |
| 1.09 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy
≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 45 W | 16 | each | 100 | ₹1,600 |
stage.html
html • 0.02 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
TD.pdf
Tender Documents • 1.24 MB
BOQ_966822.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .