Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.3 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹35.4 L+₹1.0 L (2.97%)Rejected-Finance 154 HANUMAN MANDIR DIKSHI TAL NIPHAD DIST NASHIK 422 302 | NASHIK | MAHARASHTRA | 422302 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹36.9 L+₹2.6 L (7.53%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹39.2 L+₹4.8 L (13.9%)Rejected-Finance SHOP NO 2 JANKI PLAZA BHAGWAN MAHAVIR PATH KOPARGAON AHMEDNAGAR MAHARASHTRA 423 601 | KOPARGAON | AHMEDNAGAR | MAHARASHTRA | 423601 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹39.6 L+₹5.2 L (15.1%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹44.4 L
EMD Value
₹88,800
Closing Date
3 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Nasik Road
Garrison Engineer Nasik Road AOP Complex Near AOP Gate PO Gandhinagar Nasik 422006
As per Tender Documents
2024_MES_645338_1
GE/NRC/8639/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Nasik Road
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer Nasik Road
₹88,800
Yes
20 Jun 2024
6 Mar 2024
5 Apr 2024
6 Mar 2024
3 Apr 2024
20 Mar 2024
Amount
Excavation in trenches not exceeding 1.5 m width and not exc 1.5 in depth getting out soft disintegrated rock for laying and taking down UG cable of any size
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil.
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed by Engr-in-charge.
S&F Machine cut kota stone slab 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specifed and directed
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with gray cement slurry with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L Screed bed or bedding layer of cement mortar 20 mm thick for laying floors finishes in cement mortar 1:6 complete all as specifed and directed
S&F interlocking aluminium powder coated snap grid consists of main Tee runners of size 38mm x 25mm x 1.00 mm spaced 1200mm centre to centre and cross Tee of size 25mm x 25mm x1.00mm, 1200 long spaced between the main Tee at 600mm centre to centre to form a grid of 1200mm x 600mm and provide a secondary cross Te 25mm x 25mm x 1.4mm (of length 600mm) to be interlocked of the centre of 1200mm x 600mm panel to form a grid of 600mm x 600mm and wall angle 25mm x 25mm x 1.5mm . Aluminium alloy extruded section shall be aluminium anodized ( minimum 15 micron) and shall conform to IS 733, IS 1285 and IS 737, and providing and fixing with Hangers of 4mm dia GI (upto 1200mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long size of grid 600 x 600mm complete all as specified and S&F non asbestos cement pre-painted building board 4mm thick “in ceiling fixed with screw as per manufacturer instruction”
Demolition of brick work or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillers etc but including ashlar facings, dressed stone work and precast concrete articles
M and L for brick work fly ash brick with old size bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work withfly ash bricks straight or curved on plan to any radius in half brick thick wall built in CM (1:4) complete all as specifed and directed
M&L for random rubble masonry, uncoursed well bonded bedded and solidly hearted built in CM 1:6 complete all as specified and directed.
S&F aluminium anodised powder coated (min thickness 50 microns) frame for doors, windows, ventilators, complete all as specifed and directed
S & F Aluminium anodised powder coated window and ventilator shutter, sliding type without sash bar, alumn section section weighing not less than 0.55 kg per mtr incl necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specifed and directed
S&F Sheet glass ordinary quality 4.00 mm thick exc 0.5 sqm each pane with Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specifed and directed
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of apreature 1.40mm and fixed in aluminium windows, wooden doors etc complete all as specified.
Supply & Fixing stainless steel curtain rails of 25mm dia metre etc all as specified and directed.
Supply & Fixing stainless steel fancy knob suitable for 25mm dia rail with hooks etc all as specified and directed. (Note: Knob will be approved by Engr-In-Charge)
S&F Framed work such as gates, grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 Extra only over Item 10007 for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts,sliding rails
Supply & Fix 2.00 mm thick MS sheet plain black steel door and similar work cut to size, holes, punched including round headed screws with plain 40mm lap joints with riveted or welded seams including bending or turning up mitred angles etc as requried all as directed.
Material & Labour for painting with two coats of synthetic enamel paint over a coat of red oxide on new steel surfaces exc 10cm width or girth including preparation of new steel surfacesall as specified and directed by EIC.
M&L for Cement concrete type D2(1:4:8) using 40mm graded stone aggregates as in foundation lean concrete complete all as specified and as directed.
M&L for reinforced cement concrete type B1 1:2:4 (20 mm graded stone aggregates) for lintels all as specified and as directed.
Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs also splays between floors and beams complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over cut to length bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (anneled) not less than 0.9mm dia or securing with clips quality coinforming to IS complete with drill holes in RCC column for reinforcement all as specified and as directed.
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirupps,spacers and binders complete all as specified and as directed.
Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness(Below or above ground level) un-reinforced complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
M&L for rendering 30 mm thick cement mortar on stone surfaces, concrete surfaces or other than fair faces of brick work in CM (1:4) finished even and fair with out using extra cement complete all as specifed and directed
M&L for rendering 15mm thick in cement mortar(1:6) on Stone masonry surfaces, concrete surfaces or fair faces of brick work and finishing even and smooth complete all as specifed and directed
M&L for preparating newly plastered surfaces of walls and applying two coats of OBD over over a thin layer of wall care putty over a coat of alkali resistant primer coat complete all as specified and directed.
M&L for preparating newly plastered surfaces of walls and applying two coats of Acrylic weather proof exterior paint over water based primer including prepare of surface complete all as specified and directed
M&L for preparation of old painted surfaces of any description by complete removal of existing treatment and applying three coats of white wash on undecorated surfaces of walls/ceiling complete all as specified and directed.
M&L for painting with one coat of synthetic enamel paint on old wooden/steel surfaces exc 10cm width or girth including preparation of old wooden/steel surfaces all as specified and directed by EIC.
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for.
S&F steel work in tublar purlins post, rafter including necessary cutting welding etc complete
S&F rolled mild steel plain angle cleats and plate for securing purlins to ragfter and similar small articals confirming to Fe-410-0 or Fe -310-0 complete all as specified and directed
M&L for cement concrete 1:2:4 type B-2 as in foundation filling and mass concrete as in post
M&L for submain wiring with 2 single core (Phase, Neutral and Earth) of 2x2.5 Sqmm, PVC insulated, unsheathed, single core, multistranded, 1100 volts, FRLS copper conductor cable drawn in and including 25/32mm wide PVC heavy duty connected conduits including 2.5 Sqmm 1100 V grade PVC insulated unshetted multi std FRLS type flexible copper conductor as continous earth wire and connected to common earth terminals with all accessories as required and connecting to existing main switch board/Distribution Board and testing on completion all as directed by Engineer-in-Charge.
M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. in and including medium grade, PVC non-metalic PVC riged conduit and accessories such as tee elbow jointer elbow corner with surface on wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for PVC casing & caping and IS:3419:1976 for accessories), with mild steel/pressed steel sunken boxes( with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally, and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for One 5 Amp 5 pin socket outlet point on same board with other switches including earth wire as specified.
All as per ser Item No. 39.00 herein before but with 4.0 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp 6 pin socket outlet point including PVC cable 2.5 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to commen earth & earth terminals including boards for mounting purposes.
Supply and fixing Switch socket combination 2 in One 5 Amp flash type complete all as specfied
Supply and fixing Switch socket combination multi purpose flush type 2 in One type 3 and 3 pin 5/15 amp,230V AC
Supply and fixing LED Luminaire 600x 600mm, 36 Watt,220 Volts AC recessed/Surface type fitting epoxy power coated CRCA sheet housing with electronic driver,connector block,etc complete with all acesserious internaly pre wired and indicating connecting up with twin core flexible copper conductor cable with suitable size
Supply and fix in replacement distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting SPD with front openable cover suitable for SP &N 8 ways all as specified & directed.
Supply and fixing MCB SP 6-32 Amp 230 V 50 Hz 10 Ka.
S & F metal clad socket triple pole and earth encloser 3 pin and earth plug with socket complete with TP MCB 63 amp 415 V
S&F of MCB SPN 6-32 Amp 230 V 50 Hz with 10 KA.
Supply and fix in replacement of distribution board double door, for mounting VPTN MCCB 125A DB double door 8 way IP:43 protection with door earthing c factory made, confirming to IS: 13032 fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti rust conditioning in not less than seven tank process to ensure smooth finish and protection against corrosion atmosphere. The DBs shall be single door type with hinged door with locking arrangement. The DBs shall be of same make as MCBs /Isolator. DB shall also be provided with label marking indicating the incoming and outgoing circuits on all way as specified. Make: indoasian
Supply and fixing ceiling fans,complete with three blades,down rod,accessories 230V,1200mm sweep,with Squirrel cge induction motor.with regulator
M&L for submain wiring with two single core PVC insulated unsheathed FRLSH type, multistranded flexible copper conductor 1100 Volts grde cables 2 x 4 Sqmm drawn through in and including rigid PVC heavy duty connected conduits including 4 Sqmm 1100 Volts grade PVC insulted unsheathed multi stranded, FRLSH type flexible copper conductor cable s continuous earth wire and connecting to common earth terminals complete all as specified & directed
Supply and fixing sheet metl enclosures with plug socket single pole and neutral with two pin and earth plug and with one MCB of 20 Amps (SP) complete all as specified and directed.
Supply, laying, and fixing of jointing and commissioning of cable XLPE insulated PVC sheathed, armoured 1100 Volt grade heavy duty with standard aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of cross-section area 50 Sqmm 3.5 core
M&L for earthing complete with galvanized steel plate electrode 60 cm x 60 cm x 6 mm surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25 meter below ground level with top edge of the earth plate at a depth of not less than 1.50 meter below ground level connected to galvanized iron or steel earth wire, 4.0 mm dia (No. 8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron, earth wire protected by galvanized steel pipe 15 mm dia (Light grade) & connected to main switch or main control board all as shown in electrical plate No. 5 of SSR-1991 Part I & including necessary excavation and earth work. The rate also include charcoal and salt in alternate layers 20 mm dia pipe (Light grade) for watering, protection pipe, funnel, wire mesh, PCC chamber in cement concrete (1:3:6) type C-I, 40 mm thick RCC (1:2:4) type B-1 cover and CI frame etc.
M&L for earthing complete with galvanized iron strip 25x4 60x 60 cm x 6 mm surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25 meter below ground level with top edge of the earth plate at a depth of not less than 1.50 meter below ground level connected to galvanized iron or steel earth wire, 4.0 mm dia (No. 8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron, earth wire protected by galvanized steel pipe 15 mm dia (Light grade) & connected to main switch or main control board all as shown in electrical plate No. 5 of SSR-1991 Part I & including necessary excavation and earth work. The rate also include charcoal and salt in alternate layers 20 mm dia pipe (Light grade) for watering, protection pipe, funnel, wire mesh, PCC chamber in cement concrete (1:3:6) type C-I, 40 mm thick RCC (1:2:4) type B-1 cover and CI frame etc.
Supply and fixing Solar LED street light with inbuilt solar charge controller,solar PV module,LiFePo4 battery & mounting clamp as a ready to install complete product without pole.
Supply and fixing steel tubler swaged poles complete with cast iron base plate,finial taper plug, bolts,nuts & screw as specified type 410 SP-31 09 mtr long
M&L for boring of holes under road,pavement,hard standing bytreanches technology using ultra sound technique and necessary machine including HDPE pipes of 150mm dia suitable for 0.4 mpa working pressure
M&L for Double Walled Corrugated DWC HDPE Pipe of outer dia 90mm and innter dia 75mm including 90 degree bends with coupler and rubber ring laid in trenches of size 95 mm suitable for cable protection of cable complete all as specified and directed.
Supply and fixing air cooled split unit air conditioner electric driven, single phase of cpacity of 2 TR, BEE 5 star rated complete all as specified.
Supply and fixing voltage stabilizer of 4 KVA for split Acs
Supply and fixing DBOXx MCB protected Socket PVC base model.
MAHIMA CONSTRUCTION
M/S K. K. Construction
sunway associates
MANOVANDANA CONSTRUCTION
Bidder Name
DHARMESH ENTERPRISES
MAHIMA CONSTRUCTION
M/S K. K. Construction
sunway associates
MANOVANDANA CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .