| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC SCO 529 3RD FLOOR KESHO RAM COMPLEX SECTOR 4 C CHANDIGARH 160047 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160047 | ₹14.3 L | L1 | Accepted-AOC accepted |
| 2 | L2₹15.7 LRejected-AOC 2ND FLOOR PLOT NO 338 UDHYOG VIHAR PHASE IV GURUGRAM 122015 HARYANA | GURUGRAM | HARYANA | 122015 | ₹15.7 L | L2 | Rejected-AOC rejected |
| Sl No | Description | Qty | Unit | Netromics Engineering Solutions Private Limited L2 | Hytek Communications and Networking L1 |
|---|---|---|---|---|---|
| 1.00HSR Items | |||||
| 1.01 | [23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate] | 2,750 | P.Metre | 33 ₹90,750 | 30 ₹82,500 |
| 2.00 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] | 170 | P.Metre | 44 ₹7,480 | 40 ₹6,800 |
| 3.00NS Items | |||||
| 3.01 | Supply, Erection, Testing and Commissioning of Cat 6 Information outlet to complete the job in all respect. Make : Dlink / Molex / RandM | 68 | Each | 398 ₹27,064 | 298 ₹20,264 |
| 4.00 | Supply, Erection, Testing and Commissioning of UTP Face plate (Single / dual) complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Make : Dlink / Molex / RandM | 40 | Each | 145 ₹5,800 | 125 ₹5,000 |
| 5.00 | Supply, Erection, Testing and Commissioning of UTP cat 6 Mounting 7 Feet length Patch Cords Low smoke zero halogen (LSZH/LS0H )complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Make : Dlink / Molex / RandM | 40 | Each | 230 ₹9,200 | 220 ₹8,800 |
| 6.00 | Supply, Erection, Testing and Commissioning of 24-port 19` 1 U jack panel which Should Be made of sheet steel 1.5 mm, Should be 19` 1U straight Patch Panel, 24-port,Should have integral cable management Metal shelf, Should accept Shielded as well as Unshielded jacks, Should have rear cable management shelf metallic powder coated Make: Molex / D-LINK / RandM | 3 | Each | 12,500 ₹37,500 | 11,000 ₹33,000 |
| 7.00 | Supply, Installation, Testing and Commissioning of 12 U Rack with 2 side FAN with 3 socket PDU with 15 AMP DP for power surge safety. With pole mount accessories. Rack should be certified. Make: Valrack, Comrack, Hive Network (HN) | 2 | Each | 12,500 ₹25,000 | 11,000 ₹22,000 |
| 8.00 | Supply, Erection, Testing and Commissioning of Layer 2 Switch with 24x10/100/1000 BASE-T Interface (inbuilt 6kV surge Protection), 2 x 10G Copper 4 and 10G SFP plus Uplink, Internal/External Redundant Fans and Redundant Power supply Support, Physical stack of up to 8 units, 80 Gbps per device physical stacking bandwidth, RAM/DRAM: 2GB or higher and Flash/SSD : 256MB or higher, Packet Buffer Size 2 MB, 2 Internal Fans, MAC Address Table 16K, Support IPv4 and IPv6: OSPFv2/v3, VRRP v2/v3, IEEE 802.3ah, IEEE 802.1ag, ITU-T Y.1731, ERPS, PBR, LLDP/LLDP-MED, UDLD/DULD, SPQ, WRR, Strict plus WRR, WDRR, WRED, GVRP, BPDU Filtering, Root Guard, Loop Guard, Loopback Detection, HOL Blocking Prevention, RSPAN/SPAN, L2 Protocol Tunneling, 4 x Smart fans, Operating Temp 0 to 50 °C, Storage Temperature -20 to 70°C complete in all respect. Make:-Cisco / Juniper / D-Link | 2 | Each | 1,45,000 ₹2.9 L | 1,28,000 ₹2.6 L |
Tender Value
₹13.9 L
EMD Value
₹27,840
Closing Date
11 Nov 2025, 5:00 pmClosed
AMIT GOYAL
ED - Rohtak
Provision of Cat 6, Patch Cord, Jack Panel2 Layer Switch, Dome Camera, Bullet Camera, NVR, LED UPS and conduit pipe etc. have been made in this estimate
2025_HRY_481398_1
2025267458B6 5AA7 4F39 861C ED9F59342E0C667BAR
Open Tender
Electrical Works
90 days
KHARAK RAMJI
Technical documents as per approved DNIT conditions.
3 documents required · 3 mandatory
₹1,000
₹27,840
Yes
16 Dec 2025
4 Nov 2025
12 Nov 2025
4 Nov 2025
11 Nov 2025
4 Nov 2025
Amount
HSR Items
[23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate]
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
NS Items
Supply, Erection, Testing and Commissioning of Cat 6 Information outlet to complete the job in all respect. Make : Dlink / Molex / RandM
Supply, Erection, Testing and Commissioning of UTP Face plate (Single / dual) complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Make : Dlink / Molex / RandM
Supply, Erection, Testing and Commissioning of UTP cat 6 Mounting 7 Feet length Patch Cords Low smoke zero halogen (LSZH/LS0H )complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Make : Dlink / Molex / RandM
Supply, Erection, Testing and Commissioning of 24-port 19` 1 U jack panel which Should Be made of sheet steel 1.5 mm, Should be 19` 1U straight Patch Panel, 24-port,Should have integral cable management Metal shelf, Should accept Shielded as well as Unshielded jacks, Should have rear cable management shelf metallic powder coated Make: Molex / D-LINK / RandM
Supply, Installation, Testing and Commissioning of 12 U Rack with 2 side FAN with 3 socket PDU with 15 AMP DP for power surge safety. With pole mount accessories. Rack should be certified. Make: Valrack, Comrack, Hive Network (HN)
Supply, Erection, Testing and Commissioning of Layer 2 Switch with 24x10/100/1000 BASE-T Interface (inbuilt 6kV surge Protection), 2 x 10G Copper 4 and 10G SFP plus Uplink, Internal/External Redundant Fans and Redundant Power supply Support, Physical stack of up to 8 units, 80 Gbps per device physical stacking bandwidth, RAM/DRAM: 2GB or higher and Flash/SSD : 256MB or higher, Packet Buffer Size 2 MB, 2 Internal Fans, MAC Address Table 16K, Support IPv4 and IPv6: OSPFv2/v3, VRRP v2/v3, IEEE 802.3ah, IEEE 802.1ag, ITU-T Y.1731, ERPS, PBR, LLDP/LLDP-MED, UDLD/DULD, SPQ, WRR, Strict plus WRR, WDRR, WRED, GVRP, BPDU Filtering, Root Guard, Loop Guard, Loopback Detection, HOL Blocking Prevention, RSPAN/SPAN, L2 Protocol Tunneling, 4 x Smart fans, Operating Temp 0 to 50 °C, Storage Temperature -20 to 70°C complete in all respect. Make:-Cisco / Juniper / D-Link
Supply, Erection, Testing and Commissioning of POE 24 Port 10/100/1000 Base T, 2X 1G SFP plus Ports, 1 X10/100Base-T out of band management post 1 X Serial Console port RJ45, Switch should Support stacking up to 4 switches Switch should have switching fabric performance of minimum 88GBPS sWitch fabric switch should have forwarding rate of 65 Mpps Switch should have 16K MAC entries, should support inter / external redundant PSU, Switch should have operating temperature (O C to 50 C) ). Make:- Cisco / Juniper / D-Link
Supply, Installation, Testing and Commissioning of Digital Phone with large Backlit Display of 240x60 Pixels Graphic LCD, 4 Context Sensitive Keys,Built-in 16 DSS Keys,High Quality Full Duplex Speaker Phone Features Call Forward,Waiting,Transfer,Hold,Conference,Redial, Ringer Lamp.Must have storage for minimum 20 calls per call log in the console itself. Make: Avaya / Unify / Matrix
Supply, Erection, testing and commissioning of Push Button Telephone Desktop model CLI, flash, redial, mic with speaker complete in all respect. Make :- Beetel / Coral
Supply, Erection, Testing and Commissioning of IDF/MDF with Krone Make module on Krone Make MS Box duly painted and having lock facilities. 50 Pair IDF
Supply, Erection, Testing and Commissioning of IDF/MDF with Krone Make module on Krone Make MS Box duly painted and having lock facilities. 20 Pair IDF
Supply and Laying of 20 Pair multicore Telephone cable conductor size 0.51mm bright annealed copper conductor PVC insulated and shealed in existing pipe / Channel etc. (excluding the cost and laying of pipe / channel) and making necessary connection complete in all respect . Make:- Delton / Polycab / Havells / Finolex
Supply, Installation, Testing and Commissioning of 5MP IP Network TDN Low-Light IR Rugged Bullet Camera, Image Device / Sensor - 1/3` Progressive Scan CCD / Progressive Scan CMOS or better, Resolution - 2 MP (1920 x 1080) or better, Frame Rate upto 30 fps or better, Lens Type - 3 to 9 mm Auto Varifocal Lens Motorized, IR Light and Distance: - IR Range upto 30 Mtrs. or better, Signal to Noise Ratio -) 50 db, Min. Illumination 0.03 Lx Color, IR LED on 0.0 Lux or better, Day Night - Auto Day / Night with Switchable IR Cut Filter, Video Compression - H.265, H.264, M-JPEG, Camera should have Multiple Streaming - Min. Triple, Edge Based Analytics, Storage - SD Card Slot should be expandable upto 128 GB, System Compatibitity: - ON VIF Profite SandG, Provacy Masking - Minimum 4 Privacy zones higher, Protocols - IPv4 / IPv6, HTTP, HTTPS, TCP/IP, UDP, UPnP, ICMP, RTSP, RTP, SMTP, NTP, DHCP, DNS, DDNS, Additional Features, Noise Reduction - Digital Noise Reduction On / Off, WDR - 120 dB WDR, Alarm Input / Output - 1 Alarm Input, 1 Alarm Output, Audio Input / Output - 1 Audio Input / 1 Audio Output, Environment, Operating Environment - Indoor / Outdoor, Operating Temperature - 00 C to 500 C, Ingress Protection and Vandal Resident standards - IP 66 or Better and IK 10 or Better, Certificate: - UL, FCC, EN Make:- Axis / Honeywell / Avigilion / Mobotix
Supply, Installation, Testing and Commissioning of 16 channel Network Video Recording and Management system With 2 nos HDD Slots for all the above ON/VIF complaint cameras, complete with all necessary required hardware, storage accessories, civil, electrical works and peripheral items, as required as per specifications. Make: Axis / Pelco / Bosch / Honeywell.
Supply, Installation, Testing and Commissioning of surveillance 8 TB Hard Drive for NVR Make: WD / Seagate / Toshiba
Supply, Installation, Testing and Commissioning of 43` LED Monitor, Full HD, HDMI Port, Component Video Inputs, 1 Digital Audio Out, Make: LG/Panasonic/Samsung
Supply, Installation, Testing and Commissioning of 1 KVA offline UPS complete in all respect.MAKE APC/ Miicrotek/DELTA/Emerson
Supply, Installation, Testing and Commissioning of 5MP IP Network TDN Low-Light IR Rugged Dome Camera, Image Device / Sensor - 1/3` Progressive Scan CCD / Progressive Scan CMOS or better, Resolution - 2 MP (1920 x 1080) or better, Frame Rate upto 30 fps or better, Lens Type - 3 to 9 mm Auto Varifocal Lens Motorized, IR Light and Distance: - IR Range upto 30 Mtrs. or better, Signal to Noise Ratio -) 50 db, Min. Illumination - 0.03 Lx Color, IR LED on 0.0 Lux or better, Day Night - Auto Day / Night with Switchable IR Cut Filter, Video Compression - H.265, H.264, M-JPEG, Camera should have Multiple Streaming - Min. Triple, Edge Based Analytics, Storage - SD Card Slot should be expandable upto 128 GB, System Compatibitity: - ON VIF Profite SandG, Privacy Masking - Minimum 4 Privacy zones or higher, Protocols - IPv4 / IPv6, HTTP, HTTPS, TCP/IP, UDP, UPnP, ICMP, RTSP, RTP, SMTP, NTP, DHCP, DNS, DDNS, Additional Features, Noise Reduction - Digital Noise Reduction On / Off, WDR - 120 dB WDR, Alarm Input / Output - 1 Alarm Input, 1 Alarm Output, Audio Input / Output - 1 Audio Input / 1 Audio Output, Environment, Operating Environment - Indoor / Outdoor, Operating Temperature - 00 C to 500 C, Ingress Protection and Vandal Resident standards - IP 66 or Better and IK 10 or Better, Certificate: - UL, FCC, EN Make:- Axis / Pelco / Bosch / Honeywell / Avigilion
Supply, Erection, Testing and Commissioning of UTP cat 6 Mounting 3 Feet length Patch Cords Low smoke zero halogen (LSZH/LS0H )complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Make : Dlink / Molex / RandM
Supply, Erection, Testing and Commissioning of Non Blocking `32 Bit microprocessor` / micro controller based on Stored Program Control Technique. Microprocessor EPABX system components as per specifications / features:- System should be configured for: - 04 Trunk Lines, - 04 Digital Extensions,- 40 Analog Extensions EXP UPTO 99 Extension - System should have a system memory of minimum 600 names and number., - System should have Dial by Name facility through built in keyboard in digital key phone instruments. Make :- Alcatel / Avaya / Matrix
Netromics Engineering Solutions Private Limited (BID ID -1365612)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.52 MB
BOQ_559381.xls
BOQ • 0.29 MB
AD0139792.pdf
Additional Documents • 3.58 MB
Other Document
Other Document • 0.96 MB
Download all tender documents and submit your bid