| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 00 VIDYUT NAGAR MEERANPUR SADDARALI TANDA AMBEDKAR NAGAR UTTAR PRADESH 224238 | AMBEDKAR NAGAR | UTTAR PRADESH | 224238 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹2.1 L
EMD Value
₹3,000
Closing Date
5 Mar 2020, 1:00 pmClosed
S E, OMC-X,PTPP PARICHHA
Office of S E, OMC-X,PTPP PARICHHA
Repairing and Overhauling/rewinding of various types of single/three phase fans/exhaust fans and various miscellaneous electrical works of 2x250 MW, PTPP, Parichha, Jhansi
2020_RVUNL_426738_1
T-07/OMC-X /EMD-VIII/PTPP
Open Tender
Electrical Works
Lump-sum
365 days
EMD-VIII PTPP PARICHHA
PQC AS PER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹590
Dy. CAO PTPP parichha
₹3,000
25 Mar 2020
23 Jan 2020
6 Mar 2020
23 Jan 2020
5 Mar 2020
23 Jan 2020
23 Jan 2020 - 5 Mar 2020
Amount
Checking of exhaust fan installed at various places mentioned in annexure of 2x250MW BTG & BOP area.
Exhaust fans Motor Rewinding works for 0.18 to 1 KW
Exhaust fans Motor Rewinding works for 0.18 to 1 KW 1.0 KW up to 2.0 KW
Exhaust fans Motor Rewinding works for 0.18 to 1 KW 2.0 KW up to 3.0 KW
Exhaust fans Motor Rewinding works for 0.18 to 1 KW 3.0 KW up to 5.0 KW
Exhaust fans Motor Rewinding works for 0.18 to 1 KW 5.0 KW up to 10.0 KW
Re-winding of ceiling fan motor as per scope of work.
Re-winding of single phase 600 mm sweep 40 watt,
Re-winding of cabin fan.
Exhaust fans Motor OVERHAULING works for 0.18 to 1 KW
Exhaust fans Motor OVERHAULING works for 0.18 to 1 KW 1.0 KW up to 2.0 KW
Exhaust fans Motor OVERHAULING works for 0.18 to 1 KW 2.0 KW up to 3.0 KW
Exhaust fans Motor OVERHAULING works for 0.18 to 1 KW 3.0 KW up to 5.0 KW
Exhaust fans Motor OVERHAULING works for 0.18 to 1 KW 5.0 KW up to 10.0 KW
OVERHAULING of ceiling fan motor as per scope of work.
OVERHAULING of single phase 600 mm sweep 40 watt,
OVERHAULING of cabin fan.
Supply & replacement of 6003zz bearings in exhaust fan/ceiling fan motor.
Supply & replacement of 6204zz bearings in exhaust fan/ceiling fan motor.
Supply & replacement of 6205zz bearings in exhaust fan/ceiling fan motor.
Supply & replacement of 6207zz bearings in exhaust fan/ceiling fan motor.
Supply & replacement of 6008zz bearings in exhaust fan/ceiling fan motor.
Supply and replacement of rotor shaft of Exhaust Fan Motors as per scope of work.
Supply and replacement of rotor shaft of ceiling Fan Motors as per scope of work.
Supply and replacement of End Covers for Exhaust Fan Motors.
Balancing of Fan (Blade 36” size).
Supply & fixing of 1.0 to 1.6 Amp,1.6 to2.5 Amp,2.5 to 4.0 &4.0 to 6.0 Over load relay ¾ legs of starter of exhaust fan.
Supply & fixing of 3 Phase contractor for Exhaust fan starter.(ISI Mark)
Supply and replacement of Fan blade (size 36”).
Supply and replacement of condenser of ceiling fan. (2.5 MF)
Supply and replacement of condenser of single phase Exhaust/pedestal fan.
Supply & replacement of rubber band of 36” Exhaust fan.
Repairing of safety covers of Exhaust fan as per scope of work.
Painting of safety covers of Exhaust fan as per scope of work.
Supply & replacement of rubber band of 18” Exhaust fan.
Supply & replacement of rubber block of ceiling fan.
Supply & replacement of bush of ceiling fan/cabin fan.
Repairing/replacement of Isolation mechanism of pedestal fan.
Supply and fitting of new cooling fan on Exhaust motor (1 KW to 5 KW)
Supply and fitting of new cooling fan on Exhaust motor (5 KW to 10 KW)
Providing service connection for main supply in offices as per scope of work at sr. no. 1 of Part. B
Supply & fixing of (2+8) Way consumer unit, standard make, 16-32 A MCB, ISI mark as per scope of work at sl.no. 2 of Part. B.
Complete Earthing as per IE rule & ISS code of practice as per scope of work at sl.no. 3 of Part. B.
Supply & replacement of 63 A kit-kit with top SSK make as per scope of work at sl.no. 4 of Part. B.
Supply & fixing of MCB, 63A, SSK make in place of worn out damaged MCB as per scope of work at sl. no. 5 of Part. B.
Supply & fixing of 06 Way MCB distribution board SPN (without MCB), SSK make , single door in place of worn out damaged/worn-out as per scope of work at sl. no. 6 of Part. B.
Supply & fixing of 04 Way MCB distribution board SPN (without MCB), SSK make , single door in place of worn out damaged/worn-out as per scope of work at sl. no. 6 of Part. B.
Supply & fixing of box type GI board with plastic top of S1 size as per scope of work at sl.no. 7 of Part. B.
Supply & fixing of box type GI board with plastic top of S2 size as per scope of work at sl.no. 7 of Part. B.
Supply & fixing of box type GI board with plastic top of S3 size as per scope of work at sl.no. 7 of Part. B.
Supply & fixing of box type GI board with plastic top of S4 size as per scope of work at sl.no. 7 of Part. B.
Supply & fixing of box type GI board with plastic top of S6 size as per scope of work at sl.no. 7 of Part. B.
Supply & fixing/replacement of damaged MCB, 63-16 Amp, any std. ISI make as per scope of work.
Day to day maintenance of single core double wire/single wire dressing of loose/dismantles wiring by providing gully, clamps & clips etc as per scope of work at sl.no. 8 of Part. B.
Supply & replacement of ½” plastic batten by providing clips gully.
Supply & replacement of ¾” plastic batten by providing clips gully.
Supply & replacement of 6 A, 250 V AC, SSK make switch as per scope of work at sl.no. 9 of Part. B.
Supply & replacement of pin, 6 A, 250 V AC, SSK make socket.
Supply & replacement of switch socket combined 16 A, 250 V AC, SSK make.
GI conduit wiring for fan point with ceiling rose & continuous earth wiring in 14 SWG GI conduits is to be clamped with earth wire.
GI conduit wiring for power point in 6 mm2 started Aluminum conductor GI sheathed 1100 V, ISI make in rigid heavy conduit of outer diameter 25 MM & continuous earth wire.
Installation of ceiling of fan with regulator as per scope of work at sl.no. 13 of Part. B.
GI conduit wiring for 6 A plug point (Half Point) with switch and socket & continuous earth wiring in 14 SWG GI conduits is to be clamped with earth wire.
Supply & replacement of SP&N enclosure, any std. ISI make with 2 pole and earth metal plug & socket for incorporating SP/DP MCB of 16/20 A.
M/S PRIYA CONSTRUCTION CO.
M/S T S ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .