GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
REPAIR TO REFRIGERATION, AC EQPT, WATER COOLER AND CONNECTED WORKS IN THE AOR OF STN HQ BG, STN HQ KG AND STN HQ POONCH UNDER GE 881 EWS
2022_MES_550753_1
GE/PNH-46/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹26,000
Yes
17 Dec 2022
8 Sept 2022
13 Oct 2022
8 Sept 2022
6 Oct 2022
23 Sept 2022
Amount
M&L for complete servicing and repair of Split type AC 1.5/2 Ton capacity incl taking down of air conditioner, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections and re-fixing in the same in position and testing complete all as specified and directed by Engr-in-Charge. Note:- Unsv accessories will be measured and paid seperately under respective items 2 to 13 of Sch
Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Split AC 2.0 T capacity complete all as specified and directed.
Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Split AC 1.5 T capacity complete all as specified and directed.
Supply only Fan/blower electric motor single phase 230 V complete for inner unit complete all as specified and directed.
Supply only Fan/blower electric motor single phase 230 V complete for outer unit complete all as specified and directed.
Supply only Starting capacitor of suitable capacity complete all as specified and directed.
Supply only Running capacitor of suitable capacity complete all as specified and directed.
Supply only Overload protection of suitable capacity complete all as specified and directed.
Supply only Drain pipe for Split unit PVC 20mm dia complete all as specified and directed.
Supply only Fan blade of suitable size for outer unit complete all as specified and directed.
Supply only Remote control kit complete for Split type AC complete all as specified and directed.
Supply only Condencing unit of Split type AC 1.5/2 Ton capacity with complete accessories (Outdoor type) complete all as specified and directed.
Supply only Cooling unit complete suitable for 1.5/2 Ton Split type AC with complete accessories (Indoor type) complete all as specified and directed.
M&L for complete servicing and repair of Window type AC 1.5/2 Ton capacity incl taking down of air conditioner, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections etc and re-fixing in the same in position testing complete all as specified and directed by Engr-in-Charge. Note:- Unsv accessories will be measured and paid seperately under respective items 15 to 22 of Sch
Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Window AC 2.0 T capacity complete all as specified and directed.
Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Window AC 1.5 T capacity complete all as specified and directed.
Supply only Capacitor of suitable capacity for Window AC 1.5/2 Ton capacity complete all as specified and directed.
Supply only Auto cut thermostate of suitable capacity for window AC 1.5/2 Ton complete all as specified and directed.
Supply only Operload protection for Window type AC 1.5/2 ton capacity complete all as specified and directed.
Supply only Grill for window AC of suitable size/shape /model as required at site complete all as specified and directed.
Supply only Fan blade of suitable size for window type AC unit complete all as specified and directed.
Supply only Fan/blower electric motor single phase 230 V complete all as specified and directed.
M&L for complete servicing and repair of Water Cooler any capacity, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections and re-fixing in the same in position testing complete all as specified and directed by Engr-in-Charge. Note:- Unsv accessories will be measured and paid seperately under respective items 24 to 35 of Sch
Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Water cooler 40/80 Ltrs complete all as specified and directed.
Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Water cooler 60/120 Ltrs complete all as specified and directed.
Supply only Fan/blower electric motor single phase 230 V complet for water cooler 40/80 or 60/120 Ltrs capacity water cooler complete all as specified and directed.
Supply only Running capacitor of suitable capacity complete all as specified and directed.
Supply only Starting capacitor of suitable capacity complete all as specified and directed.
Supply only Auto cut thermostate switch for water cooler complete all as specified and directed.
Supply only Overload protector for water cooler of any capacity complete all as specified and directed.
Supply only Fan blade of suitable size complete all as specified and directed.
Supply only Push cock/soft closing tap brass chromium plated of size 15 mm complete all as specified and directed.
Supply only PVC connection pipe 600 mm long, both end screwed for water cooler complete all as specified and directed.
Supply only Stop cock both end screwed chromium plated suitable for 15mm bore complete all as specified and directed.
Supply only ball valve PVC 15mm size for water cooler 40/80 ltr capacity complete all as specified and directed.
M&L for complete servicing and repair of refrigerator/deep freezer of any capacity, servicing and cleaning of all accessories, oiling of fan motor, checking of wiring connections, and re-fixing in the same in position testing complete all as specified and directed by Engr-in-Charge. Note:- Unsv accessories will be measured and paid seperately under respective items 37 to 49 of Sch
Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Refigerator 165 Ltrs capacity complete all as specified and directed.
Supply only Hermatic sealed compressor unit with new factory made sealed compressor unit, single phase electrically operated on 240 V suitable for Refigerator 286/310 Ltrs capacity complete all as specified and directed.
Supply only Auto cut thermostate switch for Refrigerator defrosts type complete all as specified and directed.
Supply only Overload protectors for regrigerations upto 310 Ltrs capacity complete all as specified and directed.
Supply only Copper strainer filter for reftrigerator complete all as specified and directed.
Supply only Relays suitable for refrigerators upto 310 ltr capacity complete all as specified and directed.
Supply only Door switch for refrigerator complete all as specified and directed.
Supply only Door spring for refrigerator complete all as specified and directed.
Supply only Freezer chest door suitable for 286/310 Ltr capacity complete all as specified and directed.
Supply only Magnetised door lock rubber strip 'D' type for regrigerator 286/310 Ltr cacpacity complete all as specified and directed.
Supply only Evaporator coil assembly 165 ltrs capacity regrigerator with copper pipe complete all as specified and directed.
Supply only Evaporator coil assembly 266/310 ltrs capacity regrigerator with copper pipe complete all as specified and directed.
Supply only Fan motor for chiller unit as per existing make complete all as specified and directed.
Supply and filling gas charging required to the System of suitable type R-34/12/32 /R22 or as per existing at site complete all as specified and directed.
Supply and filling gas charging required to the System of suitable type 134a or as per existing at site complete all as specified and directed.
S&F in repair base tray of window type AC 1.5/2 Ton capacity unit complete all as specified and directed including the following:- (a) Removing of compressor condenser, wiring kit, from base tray (b) Fixing of new base having all fittings/fixtures to accommodate all accessories made out of MS sheet 1.6mm thick duly painted. (c) Carrying out the nitrogen pressure for 24 hrs (d) Carrying out the vaccuming and gas charging to unit. Note:- Gas will be measured and paid seperately under respective items of Sch
S&F in repair base of water cooler of any capacity unit complete all as specified and directed including the following:- (a) Removing of compressor condenser, wiring kit, from base tray (b) Fixing of new base having all fittings/fixtures to accommodate all accessories made out of MS sheet 1.6mm thick duly painted. (c) Carrying out the nitrogen pressure for 24 hrs (d) Carrying out the vaccuming and gas charging to unit. Note:- Gas will be measured and paid seperately under respective items of Sch 'A'
Supply and fixing in repair PVC insulated flexible cable 3 core with multistranded copper conductors round shaped sheathed for 1100 volts grade of size 2.5 Sqmm complete all as specified and directed.
Supply and fixing in repair PVC insulated flexible cable 3 core with multistranded copper conductors round shaped sheathed for 1100 volts grade of size 4.00 Sqmm complete all as specified and directed.
Supply and fix in repair capillary copper tube for window , split, water cooler, refrigerator complete all as specified and directed.
Taking down of split AC 1.5/2 T capacity from existing location to refixing in another location incl both inner and outer units (filling up gas if necessary ) incl connected accessories in complete all as specified and directed by Engr-in-Charge.
S&F Sub main wiring with single core cable 2x 6 sq mm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade including surface PVC casing caping medium grade alongwith 1x 6 Sq mm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly including taking down old unsv sub main wiring of any type, complete all as specified and directed. Note: 3 run of 6 sqmm, and one run of pvc conduit/casing caping shall be measured as one unit.
S&F in repair Plug & Socket DB, CRCA Sheet steel, powder coated, with metal plug & socket 3 pin with 32 Amps MCB SP complete all as specified and directed.
Supply and replacement MCB SP 6-32 Amps, 10 KA complete all as specified and directed.
Supply and replacement MCB SPN 6-32 Amps, 10 KA complete all as specified and directed.
S&F in repair plug top 3 pin 15 amps ISI marked complete all as specified and directed.
M/S PARSHOTAM KUMAR GUPTA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .