Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
15 Jul 2021, 6:00 pmClosed
GE Kapurthala
GE Kapurthala
Repair and maintenance of internal electrification, LT Panels and allied work at Mil StnSuranussi under GE Kapurthala
2021_MES_445251_2
GE KPT-33/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
Kapurthala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Kapurthala
₹90,000
19 Jul 2021
24 Jun 2021
17 Jul 2021
24 Jun 2021
15 Jul 2021
29 Jun 2021
Amount
Excavation in trenches in soft/loose soil not exceeding 1.50m wide, not exceeding 1.5M depth for laying of cables, pipe, poles, stays etc including taking out old bricks/ bats and stacking and cable including rolling for reuse and removal of unserviceable cable and brick bats from site etc and getting out complete all as specified and as directed by the Engineer-in-Charge. (Note:Excavation and earth work shall be measured and paid separatelly, in case new holes are dug).
Returing, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25 cm thick each layer complete all as specified and as directed by the Engineer-in-Charge
Removal of surplus spoil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the as Engineer-in-Charge
Material and labour for sand cushioning with a layer of fine sand (using sand suitable for plaster) 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches, punned down to 18cm with hand ramming complete all as specified and as directed by the Engineer-in-Charge (Note:- 18cm compacted thickness shall be reckoned for the purpose of measurement and payment.)
Supply & Lay the bricks as brick protection using old size sub class ‘B’ old size, new bricks, laid flat, laid dry with width equal to length of brick, laid across the length of cable complete all as specified and as directed by the Engineer-in-Charge
Laying bricks as protection for cable using old retrieved bricks sub class ‘B’ old size, laid flat, laid dry with width equal to length of brick, laid across the length of cable complete all as specified and as directed by the Engineer-in-Charge
Material & Lay joint, fix and test in replacement; LT XLPE insulated, armoured underground heavy duty electric cable with aluminium conductor 1100 Volts grade of cross sectional area 240 Sqmm 3.5 core, through pipes, in ducts, on poles, in trenches, to walls etc. complete all as specified and as directed by the Engineer-in-Charge .
Supply, lay, joint, fix and test in replacement; LT XLPE insulated, armoured underground heavy duty electric cable with aluminium conductor 1100 Volts grade of cross sectional area 185 Sqmm 3.5 core, through pipes, in ducts, on poles, in trenches, to walls etc. complete all as specified and as directed by the Engineer-in-Charge .
Supply, lay joint, fix and test in replacement; LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of cross sectional area 150 Sq.mm 3.5 Core, through pipes, in ducts, on poles, in trenches, to walls etc. complete all as specified and as directed by the Engineer-in-Charge .
Supply, lay, joint, fix and test in replacement; LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of cross sectional area 70 Sq.mm 3.5 Core, through pipes, in ducts, on poles, in trenches, to walls etc. complete all as specified and as directed by the Engineer-in-Charge .
Supply, lay, joint, fix and test in replacement; LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of cross sectional area 25 Sq.mm 4 Core, through pipes, in ducts, on poles, in trenches, to walls etc. complete all as specified and as directed by the Engineer-in-Charge .
Supply, lay, joint, fix and test in replacement; LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of cross sectional area 10 Sq.mm 2 Core, through pipes, in ducts, on poles, in trenches, to walls etc. complete all as specified and as directed by the Engineer-in-Charge .
Supply and fix in replacement; MCCB (AC 415 volts) Current capacity 400 Amp four pole (TPN) breaking capacity 35 KA (coforming to IEC 60947-11/IS - 13947-II) adjustable thermal and adjustable magnetic setting frame type Cat Part No IHLCNF0400 of make Havells or equivalent in makes specified in Appendix 'B' of particular specifications including extendable terminal suitable for 315 Amp to 500 Amp/code complete all as specified and as directed by the Engineer-in-Charge .
Supply and fix in replacement; MCCB (AC 415 volts) Current capacity 200 Amp four pole (TPN) breaking capacity 25 KA (coforme to IEC 60947-11/IS - 13947-II) adjustable thermal and adjustable magnetic setting frame type Cat Part No IHLANF0200 of make Havells or equivalent in makes specified in Appendix 'B' of particular specifications including extendable terminal suitable for 200 Amp to 500 Amp/code complete all as specified and as directed.
Supply and fix in replacement; MCCB (AC 415 volts) Current capacity 125 Amp four pole (TPN) breaking capacity 16 KA (coforme to IEC 60947-11/IS - 13947-II) adjustable thermal and adjustable magnetic setting frame type Cat Part No IHLGNF0063 of make Havells or equivalent in makes specified in Appendix 'B' of particular specifications including extendable terminal suitable for 200 Amp to 500 Amp/code complete all as specified and as directed.
Taking down carefully aluminium/copper point wiring on wooden battens/through conduit (light fan, socket or power) with and including PVC conceeded/surface conduct/batten/casing and caping complete with fittings such as switches, wooden batten, ceiling roses, pendants, regulators, box type tube light fittings, removing the materials from site in the work and making good the disturbed surfaces of walls/ceiling/ floors etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for point wiring for one light point controlled by one switch with PVC unsheathed single core multistranded FRLS copper conductor cable of size 1.5 Sqmm (nominal area) concealed PVC conduit 20mm dia boreand existing cast iron/pressed steel concealed terminal boxes, providing 3 mm thick plastic laminated sheet cover including one run of PVC insulated FRLS copper conductor cable of size 1.5 Sqmm with green insulation as earth wire and connected to earth dolly 'FOR ONE LIGHT POINT CONTROLLED BY ONE SWITCH, complete all as specified and directed by Engineer in Charge.
All as per item no.17 here-in-before but ONE FAN POINT CONTROLLED BY ONE WAY SWITCH.
All as per item no. 17 here-in-before but ONE SOCKET OUTLET 3 PIN 6 AMPS ON INDEPENDENT BOARD.
All as per item no.17 here-in-before but ONE SOCKET OUTLET 3 PIN 6 AMPS ON THE SAME BOARD.
All as per item no. 17 here-in-before but 'FOR ONE LIGHT POINT CONTROLLED BY 2 , TWO WAY SWITCHES WITH CABLE 1.5SQMM.
All as per item No 17 here-in-before but One bell/bugger point controlled by one push button
Material and labour for point wiring for controlled by one switch with PVC unsheathed single core multistranded copper conductor FRLS cable of size 2.5 Sqmm (nominal area) in existing PVC conduit with including cast iron/pressed steel terminal boxes including providing new 3 mm thick plastic laminated sheet cover including one run of PVC insulated FRLS copper conductor cable of 1.5 Sqmm with green insulation as earth dolly for 6 pin, 16 Amp socket outlet on Independent board.
Supply and fix switch piano flush type single pole one way 5 Amp (ISI Marked)
Supply and fix switch piano flush type single pole one way 15 Amp (ISI Marked)
Supply and fix socket out let 2 in 1, 3 pin 5 Amp flush type (ISI Marked)
Supply and fix socket out let 2 in 1, 3 pin 15 Amp flush type (ISI Marked )
Supply and fix in replacement; electronic fan regulator 230 volts , step type,socket type ,hum free 120 watt ISI Marked.
Supply and fix in replacement; single pole and neutral enclosure 4 module in sheet steel with a two pin and earth plug and socket complete with and including one single pole MCB 25 Amp 10 KA complete all as directed all as directed by Engineer-in-Charge.
Supply and fix ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate,isolated body (ISI Marked)
Supply and fix in replacement; lamp holder angular type,PVC/Polycarbonate type with back plate suitable for batten fiitng.
Supply and fix in replacement sub main wiring with 2 single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 4.00 Sqmm 1100 volts grade including and 4.00 Sqmm PVC insulated, multi stranded, unsheathed copper FRLS wire green in colour as earthing lead drawn through concealed PVC conduit incl. Note : Three run of 4.00 Sqmm cable and 25 mm PVC conduit shall be measured & paid as one unit.
Supply and fix MCB, 6 to 32 Amp, SP, 240 Volt, 10 KA rupturing capacity.
Supply and fix MCB, 06 to 32 Amp, SPN, 240 Volt, 10 KA rupturing capacity.
Supply and fix isolator 63 Amp, TPN 240 volts, 10 KA rupturing capacity.
Supply and fix in replacement; LED decorative box type light fitting 20 Watts including Tube rod 20 watt along with all accessories, pre-wired fixed on wall/ceiling and connecting up complete with 3 core flexible cable white of size 23/0.0076 all as specified and directed by Engineer-in-charge. Fitting Cat Part No DMLN1LT8-16 of Make Crompton Greaves and LED tube rod Cat Part No LTT8-20 of Make - Crompton Greaves or equivalent in makes specified in Appendix "B" of Particular Specifications. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion.
Supply and fix in replacement; prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 8 ways single pole and neutral link complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed. (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order.(iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to galvanized earth lead of 32x6mm flat iron by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order. PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order.
Supply and fix in replacement; 10 Watts LED Bulk head fitting in IP 65, engineering plastic housing with opal diffuser including LED 10 Watts complete with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076. Cat Part No LHEOAOP7UZ6W010 of Make :Havells or equivalent in makes specified in Appendix "B" of particular Specifications. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion.
Preparation to steel surface of existing LT panels, LT feeder pillars boxes of any size and description internally and externally after scraping and scratching the old paint with emery paper etc, and painting with two coat of gray painting with spray gun and writing feeder names and numbers with suitable capital letters in English with white paint on and a black paint strip of size 20 cm x 25 cm all as directed
Material and labour for repair to LT panels feeder pillar box by dismantling old rusted and perished doors shutter and bus bar covers etc and providing new doors shutters, bus bar cover etc by cutting, welding, fabricating and made to existing shape with 3.15 mm plain black sheet and angle iron of required size including providing hinges and locking arrangement including material and labour for applying two coat of painting with synthetic enameled grey paing over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement; aluminum thimbles crimping type of size 16 to 25 Sq mm complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement; aluminum thimbles crimping type of size 50 to 120 Sq mm complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement; aluminum thimbles crimping type of size 150 Sq mm to240 Sq mm complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement; straight through joint (epoxy) for LT 1100 Volts grade, aluminum conductor including jointing kits, aluminium ferrules and labour complete for making joints and testing size 185 to 240 Sqmm, 3.5 core complete all as specified and as directed by Engineer-in-Charge.
All as per Ser Item No 49 here-in-before but Cable size 120 to 150 Sqmm, 3.5 core
All as per Ser Item No 49 here-in-before but Cable size 70 to 95 Sqmm, 3.5 core
All as per Ser Item No 49 here-in-before but Cable size 25 to 50 Sqmm, 3.5 core
All as per Ser Item No 49 here-in-before but Cable size 10 to 16 Sqmm, 4.0/2.0 core
Earthing complete with copper earth plate electrode 60 cm x 60 cm x 3 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to copper earth lead of 20 x 3 mm flat brass by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order. PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order.
Supply, fabricating installation, electrically connected LT Busbar chamber size 450mm X 300mm X 150mm out door cubical type factory made of CRCA sheet 3.15 mm thick machine pressed and angle iron frame 40x40x6mm in around the busbar chamber body fixing on the foundation/wall including spray painted with two coats of synthetic paint from out side and inside with approved stove enameled gray paint over one coat of red oxide primer complete and suitable for 440 Volts AC three Phase nutral Aluminum bus bar of each capacity 200Amp & strips fully mounted on porcelain insulator including cable connection and connected acessories.
M & L for copper strip 20 x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground
M & L for Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground
M & L for GI Strip 32 x 6 mm burried in ground
M & L for copper Strip 32 x 6 mm burried in ground
AGGARWAL ENGINEERING CO
DUGGAL CONSTRUCTION CO
J.K & Company
GULSHAN SINGH GHAI AND SON
KAMAL AGGARWAL
M/S ASHWANI SETHI
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .