Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹42.7 L+₹4.3 L (11.3%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹43.9 L+₹5.6 L (14.5%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST IN TENDER, IT IS ON L3 | |
| 4 | L4₹44.5 L+₹6.1 L (16.0%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹44.7 L+₹6.3 L (16.5%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
16 Jul 2024, 6:00 pmClosed
CWE DEOLALI
HQ CWE DEOLALI, ONSLOW ROAD, DEOLALI (MH)
AS PER TENDER DOCUMENTS
2024_MES_660721_1
88603/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AHMEDNAGAR
AS PER NIT
7 documents required · 7 mandatory
₹500
GE (NORTH) AHMEDNAGAR
₹98,000
Yes
31 Aug 2024
19 Jun 2024
18 Jul 2024
19 Jun 2024
16 Jul 2024
3 Jul 2024
19 Jun 2024 - 25 Jun 2024
Amount
Supply and fix in repairs on load change over switch existing panel, wall or LT pole of any size and , triple pole and neutral, 400 Amps, 415 V, 50 Hz front handle operated, including connecting and testing all as directed.
Supply and fixing in existing panel board for replacement MCCB, 4 Pole, 400 Amps , with breaking capacity 36 KA , fixed type(HBC Series),adjustable type thermal setting 70-100% and magnetic adjustable 5-10 times AC 415 volt ,50 HZ conforming to IEC:60947-II/IS:13947-II and connecting all as directed.
All as per item No 2 here in above but 200 Amps 36 KA breaking capacity.
Material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to GI strip 32 x 6 mm , by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion complete all as specified and directed. Note:- i) Cost of GI strip 32 x 6 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii) Excavation and returning filling of Soil any type is deemed to be included in rates.
S&F in replcement of vertical type air break switch, gang operated, tripple pole, mechnically operated, outdoor type, with all fittings and accessories mounted on and including HT 11 KV porcelain insulators and steel channel frame, GI operating rod 25 mm dia of suitable length to worked from ground, including locking arrangements , suitable for 11000 volts, 400 Amps current rating complete including dismantling existing one all as specified and as directed.
S&F drop out fuse unit, explusion type for out door air break gang oprated switch, single pole mounted on and including insulators for 11 KV working pressure fixed to and including MS channel with nuts, bolts and washer etc synthetic bounded fuse tube complete with line capcity suitable for current carrying capacity upto 100 Amps all as directed including taking down old one all as specified and as directed
S&F in replacement of HT 11 KV out door non-linear type lightening arrestor with mountings, accessories complete fixed on cross arms of two pole structure / GI flat strip and connect with same size of ACSR conductor encashed in PVC alkathine pipe with all fittings connected to earth strip with nuts, bolts and washers, transmission class having discharge capacity of 10 KA and suitable for working pressure 9 KV RMS compelete including taking down old lightning arrestor all as specified and as directed including dismantling existing one all as specified and as directed.
M&L for cable jointing kit for 11 KV grade cable for straight through heat shrinkable joint suitable for XLPE armoured aluminium conductor cable of size 3 core 95 Sqmm all as specified and directed.
M&L for cable jointing kit for 11 KV grade cable for straight through heat shrinkable joint suitable for XLPE armoured aluminium conductor cable of size 3 core 120 to 185 Sqmm all as specified and directed.
M&L for end termination cable jointing kit for 11 KV grade cable heat shrinkable joint, out door suitable for XLPE armoured aluminium conductor cable complete with jointing materials and accessories suitable for 3 core 120 to 185 Sqmm all as specified and directed.
M&L for end termination cable jointing kit for 11 KV grade cable heat shrinkable joint, out door suitable for XLPE armoured aluminium conductor cable complete with jointing materials and accessories suitable for 3 core 95 Sqmm all as specified and directed.
Supply, erecting and fixing in true vertical position of steel tubular swaged pole, 11 mtr long complete with cast iron base plate, finial taper plug, bolt, nuts and screws as specified and of type 410 SP-55, conforming to relevant IS, including one primer coat of red oxide and two coats of aluminium paint and two coats of bituminous paint inside and outside of botton portion up to 1.8 mtr length all as specified and provide circular bend 1 No of width 2 cm complete all as specified and directed. (Excavation and earth work , foundation concrete and PCC coping shall be measured and paid separately)
M&L for cement concrete (1:4:8 ) type D2 using graded stone aggregate as in foundation for pole including necessary form work all as specified & directed.
M&L cement concrete (1:3:6 ) type C1 using graded stone aggregate as in foundation for pole including necessary form work all as specified & directed.
M & L for PCC(1:2:4) type C-2 using 20mm grade stone aggregates for coping and similar work all as specified and directed.
Demolation of cement concrete in coppings etc complete all as specified and directed by Engineer-in-Charge.
Repair / Overhauling of air break switch by replacing stationary and moving contacts, flexible copper chord, GI nuts, bolts etc including alingment for smooth functioning from ground level all as required at site and all as specified & directed.
Decanning the transformer oil from leaking transformer by opening the stop valve.Checking for leakages, arresting the leakages, replacing cork sheet gasket 5 mm thick,bushing,washer, HV/LV Road,tapchanger gasket, reassembling the transformer completely refilling transformer oil, connecting HT / LT connection complete all as directed. NOTE:(i) Spares required shall be measured and paid separately under relevant. (ii) Topping of transformer oil will be measured and paid separately. (iii) Gasket, cork sheet,washers are deemed to the quoted rates.
Material only in replacement of silica gel including cleaning the breather all as directed.
S & F in replacement, breather assembley with silica gel all as directed
S & F in replacement of HT bushing, porcelain vitreous brown body suitable for 11 KV as per IS 3347.
S & F in replacement of LT bushing, porcelain vitreous brown body 1100 V grade as per IS 3347.
Supply & Fix in replacement of HV rod, brass, 12 mm dia, 300 mm long with brass nut, 2 Nos and washers complete all as directed.
Supply andfix in replacement of LV rod, brass, 15 mm dia, 300 mm long with brass nut 2 Nos and washers complete all as directed.
M & L for taking down carefully transformer of following capacity, any make, any type from pole / plinth/ base, disconnecting HT & LT side connections, earthing strip of transformer, supporting angles, cross arm, shifting / transporting transformer carefully from the site to the workshop minimum 30 Kms from site opening the top cover of the transformer, bushing,removing the tap changer, conservator,breather assembly, draining of oil from the transformer, lifting the core complete taking out defective coils from the core, cleaning the tank and reassembling the transformer after carrying out the repairs/replacement of worn out part, ovening the complete unit till to get desired megger value, transporting returning back to the site installing re-commissioning and testing of the transformer at its original place, connecting up HT & LT sides, earthings, supports / cross arms etc all as directed by EIC (Note : (i)Spares, Rewinding of transformer if will be measured and paid separately under respective items . (ii) Reinsulation & heating of coil is included of quoted rate. (iii) Insulating oil will be measured and paid separately. (iv) Painting of transformer is included of quoted rates
Transformer of capacity 50/100KVA
Transformer of capacity 200/250 KVA
Transformer of capacity 300/315 KVA
Transformer of capacity 400/500 KVA
Rewinding of old/burnt out coils of transformer by super enamelled copper winding wire/strips of appropriate size of superior quality including insulating, varnishing, heating, coil in position and charging completely all as directed in Engr-in-Charge.
Rewinding of old/burnt out coils of transformer by super enamelled Aluminium winding wire/strips of appropriate size of superior quality including insulating, varnishing, heating, coil in position and charging completely all as directed in Engr-in-Charge.
Supply & filling new insulating oil conforming to IS 335 for transformer etc all as specified and directed
Labour only for dehydration filtration and cleaning of transformer oil of 33 KV / 11KV power transformer / distribution transformer / HT switchgear till achievement of die-electric-strength of 56 KV for new insulating oil and 45 KV for existing oil at 2.5MM Gap including testing of existing oil die eletric strength after and before with oil testing instrument including test report complete all as specified and directed Note : (i)Toping of Transformer oil shall be measured and paid separately (ii) External Eletric supply/ vehical mounted DG supply required at the time of dehydration should be responsibility of contractor rate included in quated rate.
Excavation in trenches not exc 1.5 meter wide and not exc. 1.5 mtr in depth for laying of under ground cable, pole foundation and stays etc and getting out in soft / loose soil all as specified and as directed
Returning and filling in, including spreading and levelling, water and well remming in layers not exc. 25cm all as specified and directed.
Removing excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed.
Supply, laying, testing & commissioning 3 core 95 Sqmm HT 11 KV (Earthed) XLPE insulated screened PVC bedded, electric power cable (heavy duty) ISI marked with aluminium conductor 11000 volts grade,circular screened with extruded semi conducting compound in combination with copper tape , inner sheath of PVC tape galvanized steel strip flat , around and overall PVC sheathed, armoured conforming to IS 7098 Part II, 1985 amended upto date, ISI marked, laid in trenches or passing through pipes/ducts including taking down old cable of any size all as specified and as directed.
Supply, laying, testing & commissioning 3 core 120 Sqmm, HT 11 KV (Earthed) XLPE insulated screened PVC bedded, electric power cable (heavy duty) ISI marked with aluminium conductor 11000 volts grade,circular screened with extruded semi conducting compound in combination with copper tape , inner sheath of PVC tape galvanized steel strip flat , around and overall PVC sheathed, armoured conforming to IS 7098 Part II, 1985 amended upto date ISI marked, laid in trenches or passing through pipes/ducts including taking down old cable of any size all as specified and as directed. Notes for item No 33 & 34 above :- (i). Excavation and earthwork , sand cushioning , GI pipe, cable protection will be measured and paid for separately (ii). Cable shall be tested at high voltage test before & after laying. (iii). No straight through joint will be permitted inside pipe or duct. (iv). Cost of straight through if any deemed to be included in cost of cable.
Supply & laying of heavy duty HDPE DWC pipe for HT cable pipe ISI marked of outer dia 110 mm and Inner dia 95 mm polythylene with smooth internal and external surface for non pressure under ground cable icluding coupler and bends complete all as specified and directed Make : Suprime/Finolex/Prince/Jain
M & L for painting of Street light poles of any type (with hydrolic vehicle / ladder) including cross arms, channel, flat iron clamps etc 11 mtr long in two coats of aluminium paint and one coat of red oxide as primer including writing of pole nos (Yellow circle and Number in black) and providing 3 Nos of radium with width 50 mm size band / strap with Red, Yellow, Green colour 300 mm apart from plinth block around the pole etc complete as all as specified and directed in Engr-in- Charge. Note:- Hydrolic Vehicle / Ladder for painting is responsibility of contractor and rate of Hydrolic vehicle and ladder including in quoted rate.
Material and labour for spray painting of 4 Pole structure with two coats of synthetic enamel paint including channel,bracket of 4 pole structure , prepartion of surfaces,Scraping the old paint and writing pole No in Black letter under yellow circle all as directed.
M&L for pin type, porcelain, vitreous, brown or green insulator including one galvanised mild steel spindle, steel washers and one galvanised nut of size 150mm height, 150mm dia for 11000 volts grade complete all as specified & directed.
M& L for disc type, pocelien, vitreous, white or brown 145mm hieght, 255 mm dia ball and socket type complete with tension assembly clamps for conductor for 11000 volts grade single disc assembly complete all as specified & directed.
supply and stringing HT 11 KV ACSR conductor (Weasel/ Ferret) for over head line securing on pole complete including binding wire, jointing sleeves aluminium tap and PG clamp etc of any size all as specified and as directed. Note :- (a) Jumper on cutout point/2 pole structer/4 pole structure shall be provided with PVC insulated sleeve. (b) Rate is inclusive of jumper & tree branch cutting to make a safe distance from over head line.)
M&L for restringing of LT over head line consisting of 4/5 conductors by dismantling taking down, repairing wherever required including cutting, re-joining and restringing in situ, with proper sag, binding to insulator with and including aluminium binding wire complete all as specified and directed
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, botls, washers, welding bending cold or hot, drilling holes for bolts, in any shape or size as indicated or irected and inclusive of one coat of red oxide primer, one under coat and one inishing coat of aluminium paint all as specified and as directed.
S&F stay assembly complete with accessories as shown in Electrical Plate No 1 of SSR 2009 (Part I) using stay rod 20mm dia, including clamps made out of 50 x 6mm MS flat, MS galvansied stay plate 300mmx 300mm x 6mm and galvanised thimble including insulator 90x140mm all as specified and as directed. (loop type insulator, stay clamps, excavation and concrete shall be measured and paid separately
M&L for prunning and removing of tree branches touching to electric over head lines wild growth around LT /HT over head lines and around pole and stay complete to make clear span of 1.5 Mtr of tree both side of the OH line with JCB, Cutter and all tools, plants etc all as directed by Engineer-in-Chief Note : (i) Distance between pole to pole will be measured and paid. (ii) Any breakdown of line caused during punning shall be made good without any extra cost. (ii) Prunning of tree to be done twice a year (before & after rainy season) (iii) The contractor has to ensure the proper safety of the tradesmans to avoid any mishappening. If any mishappening occures the contractor will be solely responsible for it.
Supply and spreading in electrical outdoor installation yard, stone aggregate of size 20 mm at 11KV substations / Near DP structures after through cleaning, anti grass treatment etc all as per pecified and as directed.
Supply and spreading in electrical outdoor installation yard, stone aggregate of size 40 mm at 11KV substations / Near DP structures after through cleaning, anti grass treatment etc all as per pecified and as directed.
Supplying and laying factory made unreinforced precast concrete cable cover ISI marked, class HV, type 1, flat of size 300 mm x 180 mm x 40 mm duly embossed with "HT CABLE 11 KV", laid lengthwise perpendicular to the axis of cable including pcc foundation (1:3:6) complete all as specified and as directed.
Material and labour for spray painting the 11 KV transformer upto 250 KVA capacity with two coats of synthetic enamel paint including prepartion of surfaces,Scraping the old paint and writing SM MES No in Black letter all as directed.
Supply,installation,testing and commissioining factory made LT feeder pillar panel CPRI approved, size of panel as per CPRI Specification,double door floor mounted outdoor type,as per IP-65 grade,made out of CRCA sheet 3.15 mm thick of outer body with Aluminium bus bar 600 Amps,4 strip,(3 phase & Neutral) complete drilled,insulated with colour coaded insulation tape,mounted on insulators etc. Panel should be dust proof,vermin proof,powder coated,locking should be screw type,mechanical type,inter locking,should have danger notice for 415 volt,AC,mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearanceduly embedded in and including PCC block(1:2:4) type B1 foundation for fixing of panel complete including ternination of all incoming and outgoing cables with suitable size thimbles/lugs, glands , Nuts & Bolts complete all as required and directed.( santoshi line)
Incoming : - (i) MCCB 400 Amp adjustable type with , 4 Pole, 36 KA - 01 No. (Ics=100%Icu) (ii) Volt meter 0 to 500 Volts, Square flush pattern, digital type with CTs – 01 No (iii) Amp meter square flush pattern 0 to 400 Amps digital type with CTs -01 No. (iv) Indicating lamp LED type one set in incoming phases. (v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs (vi) Connection from MCCB to Busbar shall be of solid Aluminium conductor (vii) MCCB shall be provided with suitable spreader of aluminium conductor for fixing of incoming cable Outgoing ways :- MCCB 200 Amps adjudtable type ,4 pole,25 KA-02 Nos (Ics=100%Icu) MCCB 100 Amps adjudtable type ,4 pole,25 KA-02 Nos (Ics=100%Icu MCCB 63 Amps adjudtable type ,4 pole,25 KA-01 Nos (Ics=100%Icu)
Supply,installation,testing and commissioining factory made LT feeder pillar panel CPRI approved, size of panel as per CPRI Specification,double door floor mounted outdoor type,as per IP-65 grade,made out of CRCA sheet 3.15 mm thick of outer body with Aluminium bus bar 600 Amps,4 strip,(3 phase & Neutral) complete drilled,insulated with colour coaded insulation tape,mounted on insulators etc. Panel should be dust proof,vermin proof,powder coated,locking should be screw type,mechanical type,inter locking,should have danger notice for 415 volt,AC,mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearanceduly embedded in and including PCC block(1:2:4) type B1 foundation for fixing of panel complete including ternination of all incoming and outgoing cables with suitable size thimbles/lugs, glands , Nuts & Bolts complete all as required and directed.( Armament wing)
Incoming : - (i) MCCB 400 Amp adjustable type with , 4 Pole, 36 KA - 01 No. (Ics=100%Icu) (ii) Volt meter 0 to 500 Volts, Square flush pattern, digital type with CTs – 01 No (iii) Amp meter square flush pattern 0 to 400 Amps digital type with CTs -01 No. (iv) Indicating lamp LED type one set in incoming phases. (v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs (vi) Connection from MCCB to Busbar shall be of solid Aluminium conductor (vii) MCCB shall be provided with suitable spreader of aluminium conductor for fixing of incoming cable Outgoing ways :- MCCB 200 Amps adjudtable type ,4 pole,25 KA-02 Nos (Ics=100%Icu) MCCB 160 Amps adjudtable type ,4 pole,25 KA-02 Nos (Ics=100%Icu MCCB 63 Amps adjudtable type ,4 pole,25 KA-02 Nos (Ics=100%Icu)
Supply,installation,testing and commissioining factory made LT feeder pillar panel CPRI approved, size of panel as per CPRI Specification,double door floor mounted outdoor type,as per IP-65 grade,made out of CRCA sheet 3.15 mm thick of outer body with Aluminium bus bar 600 Amps,4 strip,(3 phase & Neutral) complete drilled,insulated with colour coaded insulation tape,mounted on insulators etc. Panel should be dust proof,vermin proof,powder coated,locking should be screw type,mechanical type,inter locking,should have danger notice for 415 volt,AC,mounted on 50 x50 x6 mm angle iron frame having minimum 2 feet ground clearanceduly embedded in and including PCC block(1:2:4) type B1 foundation for fixing of panel complete including ternination of all incoming and outgoing cables with suitable size thimbles/lugs, glands , Nuts & Bolts complete all as required and directed.( DMR 141/142)
Incoming : - (i) MCCB 400 Amp adjustable type with , 4 Pole, 36 KA - 01 No. (Ics=100%Icu) (ii) Volt meter 0 to 500 Volts, Square flush pattern, digital type with CTs – 01 No (iii) Amp meter square flush pattern 0 to 400 Amps digital type with CTs -01 No. (iv) Indicating lamp LED type one set in incoming phases. (v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs (vi) Connection from MCCB to Busbar shall be of solid Aluminium conductor (vii) MCCB shall be provided with suitable spreader of aluminium conductor for fixing of incoming cable Outgoing ways :- MCCB 200 Amps adjudtable type ,4 pole,25 KA-02 Nos (Ics=100%Icu) MCCB 160 Amps adjudtable type ,4 pole,25 KA-02 Nos (Ics=100%Icu MCCB 100 Amps adjudtable type ,4 pole,16 KA-01 Nos (Ics=100%Icu)
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard dense soil etc complete all as specified and directed by Engineer-in-Charge
M & L for cement concrete (1:4:8) type C2 using 20 mm graded stone aggregate in foundations, filling as mass concrete etc complete all as specified and directed by Engineer-in-Charge
Supply and fix 50 x 50 x 6 mm thick angle iron frame flat iron 40 x6 mm cut length including drilling holes for fixing of nut and bolts to hold chain link fencing including painting with two coats of synthetic enamel paint over one coat of red oxide primer on all exposed surface complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire and 10mm dia ms round bar, straining bolts etc complete all as directed.
Supply only chain link fencing , any mesh, 4 mm dia ms galvanised wire aperture 50 mm complete all as specified and directed by Engineer-in-Charge
Supply and laying of bricks surrounding the stone aggregate at sub station including necessary excavation,returning and removing complete all as specified and directed.
Material and labour for spray painting the 11 KV transformer above 250 KVA capacity with two coats of synthetic enamel paint including prepartion of surfaces,Scraping the old paint and writing SM MES No in Black letter all as directed.
M &L for construction of plinth (of size 2000mm x 2000 mm x 1500 mm) including excavation in trenchs in any type of soil,PCC 1:4: 8 in foundation fly ash bricks machinaryin cement mortor1 : 6 ,filling with moorum inside the plinth and RCC 1:2:4 over plinth including 16 mm bar reainfrocement with center to centre distane 100mm and external surface of masonary shall be plasterd with cement morter 1:4 and painted with weather coat paint ( double coat paint ) of shade as directed by Engr In Charge complete all as specified and directed by Engr in charge
Supply and fixing in replacement of HT single core power cable 11 KV ( earthed) strandred of size 95 Sqmm ,compacted,circular,aluminium conductor, conductor screen with extruded semiconducting compound XLPE Insulated, insulation screening with extruded semiconducting compound in combination with copper tape,aluminium round wire armored and FRLS PVC inner and outer sheathed,oxygen index cable confirming to IS 7098(Part II) 2011 up to date amendments complete all as specified.
M & L for replacement of Galvanised iron strip 32 x6mm buried in ground
M/L for GI Tubes,of size 80mm dia Medium grade, galvanised, with all fitting , laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
M&L for road cutting upto 300mm deep and 200mm wide for crossing GI pipe line through road including making good the disturbed surface by filling cement concrete( 1:2:4) etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of synthetic insulating rubber mat tested for HT 11/22 KV with test certificate for installation of size 2m x1m x12 mm etc complete all as specified and directed by Engineer-in-Charge
Ms. S.K. ASSOCIATES
M/S YASH ELECTRICAL
vedant engineering enterprises
Maruti Abhiyantriki
Mahindra Electric Stores
BHAVIN INFRA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .