Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC | ₹14.0 L | L1 | Accepted-AOC DUE TO L1 BIDDER |
| 2 | L2₹16.1 L+₹2.1 L (14.9%)Rejected-AOC VILL JASSAI DISTRICT BARMER RAJ 344001 | JASSAI | BARMER | RAJASTHAN | 344001 | ₹16.1 L+₹2.1 L (14.9%) | L2 | Rejected-AOC DUE TO NOT L1 BIDDER |
| 3 | L3₹16.8 L+₹2.8 L (19.8%)Rejected-AOC 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | ₹16.8 L+₹2.8 L (19.8%) | L3 | Rejected-AOC DUE TO NOT L1 BIDDER |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
21 Feb 2020, 6:00 pmClosed
GE ARMY BARMER
GE ARMY BARMER POST BOX NO 53 JALIPA MIL STN BARMER 344001
REPAIR MAINTENANCE AND RESTRINGING OF LT DISTRIBUTION OVER HEAD LINES REPLACEMENT OF WORN OUT ACSR CONDUCTOR POLES LT FEEDER PILLAR BOX APFC PANEL UG CABLE AND OTHER ALLIED WORKS AT JALIPA MIL STN UNDER GE ARMY BARMER
2020_MES_315941_1
GE(A)/BMR-51 OF 2019-20
Open Tender
Miscellaneous Works
Item Rate
240 days
GE ARMY BARMER
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE ARMY BARMER
₹32,000
Yes
5 Jun 2020
17 Jan 2020
24 Feb 2020
17 Jan 2020
21 Feb 2020
31 Jan 2020
Amount
Dismantiling/uprooting of LT pre-stressed concrete poles /steel poles of any size and shape including taking out dismantled portion of pole embended in ground after necessary demolition of foundation concrete and making good disturded ground properly and removing the debris out side MD land complete all as specified and as directed. Note :- The necessary excavation & earth work is required to be included in the rate quoted,
Dismantling of unservicable steel structure, cross arms, bracings, supports, clamps from two /four pole stucture at various location complete all as specified and as directed.
Dismantlng of stay assembly complete with stay rod including demolition of PCC and including necessary excavation and earth work complete all as specified and as directed.
Disconnecting electric connection and takingdown old aluminium conductor steel reinforced (ACSR) of different size from over head line complete all as specified and as directed .
Disconnecting electric connection and takingdown old guarding cradle /earth wire from over head line complete all as specified and as directed .
Dismantling LT insulators pin/ shackle/ disc & loop type from existing OH lines complete all as specified and as directed .
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5 mtr in depth for foundation, laying of cable / pipe line etc and getting out in soft / loose soil complete all as specified and directed .
Excavation in trenches not exceeding 1.5mtr wide and depth exceeding 1.5 mtr but not exceeding 3.0mtr in depth for foundation etc and getting out in soft / loose soil complete all as specified and directed .
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soils complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50m depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed .
Cement concrete 1:4:8 type D2 by using 40mm graded crushed stone aggregates for foundation of poles / struts / stays etc complete all as specified and as directed .
Cement concrete 1:3:6 type C-1by using 20mm graded crushed stone aggregate for coping & pedestal including necessary formwork and fair finishing to exposed surface without using extra cement complete all as specified and as directed.
Prestressed concrete pole 9 mtr long 102mmx152mm at top and 102mmx289mm at bottom, class 10 complete all as specified and as directed .
Cross arms, bracings, supports, clamps,ladder and back plates fabricated from steel sections including nuts, bolts, washer, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminum paint over one coat of red oxide primer complete all as specified and as directed .
Fixing only serviceable cross arms, bracings, supports, clamps,ladder and back plates including nuts, bolts, washer, welding, bending cold or hot, drilling holes for bolts if required, in any shape or size as indicated or directed and including preparation of old steel surface and apply one coat of aluminum paint complete all as specified and as directed . Note :- Serviceable cross arms obtained from slitem No.02 of above will be re used.
S& F pin type, porcelain, vitreous, white, green & brown insulator including one galvanised iron steel spindle, two galvanised iron washer and one galvanised iron nut, size 65mm dia x 100mm height for 1100 Volts grade complete all as specified and as directed .
Fixing only serviceable pin type, porcelain, vitreous, white, green & brown insulator including one galvanised iron steel spindle, two galvanised iron washer and one galvanised iron nut, size 65mm dia x 100mm height for 1100 Volts grade complete all as specified and as directed . Note :- Serviceable insulators obtained from slitem No.06 of above will be re used.
S&F shackle type insulators, porcelain, vitreous, brown or green insulator including galvanised mild steel straps, washers, insulators, bolts, washers and nuts, working pressure 1100 volts and size of 75mm in height and 90mm dia with section of straps 31 x 3mm and dia of bolts 12mm complete all as specified and as directed .
S&F shackle type insulators, porcelain, vitreous, brown or green insulator including galvanised mild steel straps, washers, insulators, bolts, washers and nuts, working pressure 1100 volts and size of 100mm in height and 115mm dia with section of straps 31 x 5mm and dia of bolts 14mm complete all as specified and as directed .
Fixing only serviceable shackle type, porcelain, vitreous, white, green & brown insulator of any size and shape for 1100 volts grade complete all as specified and as directed . Note :- Serviceable insulators obtained from slitem No.06 of above will be re used.
Stay assembly complete with 230 x 230 x 6mm thick plate and 16mm dia stay rod and stay insulators all as shown in electrical Plate No. 1 complete all as specified and as directed . Note: - loop insulator, stay clamps, Excavation & Earth work and, PCC shall be measured and paid for separately.
S&F loop type porcelain insulator, vitreous white, brown or green, over all dimension 65x90mm and clearance of hole 16mm complete all as specified and as directed.
Supply, fix, and stringing of aluminium conductor steel reinforced (ACSR) conductor on existing poles including straining, binding with insulators with aluminium binding wire and providing PVC sleeves for jumpers complete all as specified and as directed . Note :- Measurement and payment shall be made by measuring horizontal distance between centres of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers etc complete all as specified and directed.
Fixing only by re-stringing of of aluminium conductor steel reinforced (ACSR) conductor on existing poles including straining, binding with insulators with aluminium binding wire and providing PVC sleeves for jumpers complete all as specified and as directed . Note :- Serviceable ACSR conductors obtained from Sl item No.04 of above will be re used and measurement and payment shall be made by measuring horizontal distance between centres of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers etc complete all as specified and directed .
PVC fibre separator for LT overhead line conductor 3/4 conductor for maintaining horizontal spacing complete with nut and bolts complete all as specified and as directed .
Galvanised steel wire 3.15mm or 4mm dia as earth wire complete all as specified and as directed .
Galvanised steel wire 3.15mm or 4mm dia fabricated as in cradles, hexagonal /rectangular complet all as specified and as directed .
Fixing only serviceable galvanised steel wire 3.15mm or 4mm dia as earth wire complete all as specified and as directed Note:- Serviceable galvanised steel wire obtained from slitem No.05 of above will be re used.
Trimming / cutting of tree branches, bushes obstructing the HT/ LT OH lines, making clearance at a distance of 3mtr from outer conductor of OH lines including removal of rubbish to out side MD land complete all as specified and directed .
Cutting shurbs, vegetation, grass , bush, weed, trees and saplings not exceeding 30cm in girth, measured at a height of one metre above ground level in inside sub station building, pump house, OHT's etc., including removal of rubbish to out side MD land complete all as specified and directed .
M&L earthing complete with galvanized steel earth plate electrode 60cm X 60cm X 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized M.S. earth strip 32mm x6mm by means of bolts, nuts, check nuts and washers of galvanized iron mild steel all as shown in Electrical Plate No. 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanized iron 40mm bore light grade pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal / salt, funnel etc complete all as specified and directed by Engineer-in-charge. Note: - (i) The concrete pit shall be PCC 1:3:6 type C-1, 40mm thick pre-cast cover slab of RCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate, reinforced with 8mm TMT bars @ 10 cm c/c on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in Electrical Plate No. 3 of MES SSR Part-I, (ii) Item includes the cost of GI pipe up to 7.50m for protection of earth wire/strip, (iii) Item includes the cost of earth lead wire/strip up to7.50m & (iv) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate quoted.
S & F in replacement of indicator lamp LED type red,blue and yellow colour including making necessary connection in existing panel complete all as specified and as directed.
S & F in replacement of MCCB,AC,415volts,400 Amp,36KA,4 pole, thermal magnetic release including making necessary connection in existing panel complete all as specified and as directed .
S & F in replacement of MCCB,AC,415volts,250 Amp,25KA,4 pole, thermal magnetic release including making necessary connection in existing panel complete all as specified and as directed.
S & F in replacement of MCCB,AC,415volts,200 Amp,25KA,4 pole, thermal magnetic release including making necessary connection in existing panel complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of MCCB,AC,415volts,160 Amp,25KA,4 pole, thermal magnetic release including making necessary connection in existing panel complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of MCCB,AC,415volts,125 Amp,25KA,4 pole, thermal magnetic release including making necessary connection in existing panel complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of MCCB,AC,415volts,100 Amp,16KA,4 pole, thermal magnetic release including making necessary connection in existing panel complete all as specified and as directed.
S & F in replacement of MCCB,AC,415volts,63 Amp,16KA,4 pole, thermal magnetic release including making necessary connection in existing panel complete all as specified and as directed .
S & F in replacement of Contactor 3/4 pole ML-1.50 to 2.0 including making necessary connection in existing panel complete all as specified and as directed .
S & F in replacement of Contactor 3/4 pole ML- 2.50 to 3.0 including making necessary connection in existing panel complete all as specified and as directed.
S & F in replacement of Contactor 3/4 pole ML- 4.0 including making necessary connection in existing panel complete all as specified and as directed .
S & F in replacement of Capacitor Bank Heavy duty 5KVR including making necessary connection in existing panel complete all as specified and as directed .
S & F in replacement of Capacitor Bank Heavy duty 10KVR including making necessary connection in existing panel complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of Capacitor Bank Heavy duty 15KVR including making necessary connection in existing panel complete all as specified and as directed .
Boring of holes under the road / pavement / hard standing by trenchless technology by using ultra sound technique or by manual horizontally in any type of soil and inserting GI pipe of any size for drawing the cable complete all as specified and as directed. Note :- GI Pipe shall be measured and paid seperately.
Preparation of old painted surfaces above the planting depth / PCC coping of steel tubular poles of 9.00 mtr length including MS clamps, cable protection pipe, bracket fitted with street light fitting by scrapping with steel wire brush and applying two coats of aluminium paint to external surfaces of pole, MS cross arms and clamps, cable proecion pipe etc.,including zebra colour of painting up to 1.5mtr height fromtop of the coping / bottom of pole as per site condition complete all as specified and as directed . Note :- Zebra colour will be applied by synthetic enamel paint of black / yellow colour as approved in alternate strips of each 30cm width.
Preparation of old painted surfaces of LT PCC poles and applying zebra colour of painting up to 1.5mtr height from top of the coping / bottom of pole as per site condition including preparation of MS clamps, cable protection pipe, bracket fitted with street light fitting by scrapping with steel wire brush and applying two coats of aluminium paint to external steel surfaces including MS cross arms and clamps, cable proecion pipe etc.,complete all as specified and as directed . Note :- Zebra colour will be applied by synthetic enamel paint of black / yellow colour as approved in alternate strips of each 30cm width.
Taking down old/unserviceable under ground LT cable of any cross-sectional area from trenches/walls / poles after dis-connecting connections including cable protection stone slab /covers, pipes etc., complete all as specified and directed by Engineer-in-charge.
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and not less than 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified and as directed.
Laying only servieable stone slab ,laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified and as directed. Note :- Serviceable stone slab obtained from slitem No.51 of above will be re used.
Supply and spreading clean dry sand ( Tibba sand) in trenches for cushioning to PVC cable and punning to provide required cover to UG cable complete all as specified and directed . Note :- Punned thickness shall be measured for the purpose of payment.
Supply & Lay in trenches, fixing or passing through pipe, fixed to wall / pole XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable of 10 Sqmm 2.0 core, 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing complete all as specified and as directed.
Supply & Lay in trenches, fixing or passing through pipe, fixed to wall / pole XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable of size 10 Sqmm 4.0 core, 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing complete all as specified and as directed.
Supply & Lay in trenches, fixing or passing through pipe, fixed to wall / pole XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable of size 16 Sqmm 2.0 core, 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing complete all as specified and as directed.
Supply & Lay in trenches, fixing or passing through pipe, fixed to wall / pole XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable of size 16 Sqmm 4.0 core, 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing complete all as specified and as directed.
Supply & Lay in trenches, fixing or passing through pipe, fixed to wall / pole XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable of size 25 Sqmm 3.5 core, 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing complete all as specified and as directed.
Supply & Lay in trenches, fixing or passing through pipe, fixed to wall / pole XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable of size 35 Sqmm 3.5 core, 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing complete all as specified and as directed.
Supply & Lay in trenches, fixing or passing through pipe, fixed to wall / pole XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable of size 50 Sqmm 3.5 core, 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing complete all as specified and as directed.
Supply & Lay in trenches, fixing or passing through pipe, fixed to wall / pole XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable of size 95 Sqmm 3.5 core, 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing complete all as specified and as directed.
Laying only in trenches, fixing or passing through pipe, fixed to wall / pole XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty LT under ground cable 1100 volts grade with stranded aluminium conductor including providing lugs as required and connection, testing complete all as specified and as directed. Note :- Serviceable cable obtained from slitem No.51 of above will be re used.
M&L GI tubing , light grade of 50mm bore with fittings as in road crossings for cable protection complete all as specified and as directed.
M&L GI tubing , light grade of 50mm bore with fittings fixed to wall / pole or laid in floor for cable protection including clamping of pipe with MS flat of size 50mm long of 12mm dia including nut, bolt & washers of size 50X12mm whereever required complete all as specified and as directed.
Re fixing / re laying of old steel GI tubing as in cable protection complete all as specified and as directed. Note :- Serviceable pipe obtained from Sl item No.51 of above will be re used.
Supply, Fix, connecting and testing of energy efficient, pressure die cast aluminium housing with heat resistant toughened glass with frame & IP-66 protection and impact resistance IK 07, LED street light luminaries 45 watt 5700K, fixed on pole including taking down unsrviceable light fitting complete all as specified and as directed. Make : Havells Cat Part No LHETAXU7PN6J045 or techno commercially equivalent model of make Bajaj/Philips/CG
S & F in replacement of current relay suitable for DC system with working voltage 110V DC, type CGI 14N and Aux DC supply 75-250 V DC complete all as specified and as directed.
m/s jogaram sujaram
Rasam Engg Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .