Loading…
Loading…
Tender Value
₹98.5 L
Closing Date
1 Oct 2026, 12:30 pmClosed
Chief Manager Works
Proposed construction for FTI ADB expansion including Civil Electrical and Air conditioning works for ARDC Division HAL Bangalore
TENDER NOTICE/NCP/49/26-27::HAL/FMD/C-49/26-27
TENDER NOTICE/NCP/49/26-27
Open Tender
Works
06MONTHS
Contract Section Civil-FMD-Bangalore
Refer Tender Document
₹0
Exempted
1 Oct 2026
6 Aug 2026
1 Oct 2026
1 Oct 2026
14 Aug 2026
Name of the Individual / Firm / Company: * Mandatory
Type of ownership
Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, Contractor registration No etc.,
Address for correspondence:
PAN No.:
Goods and Service Tax ID No.
Contact details
Please Enter Contact person Name
Pls Enter Mobile No
Registered Contractor
Related Document to be Uploaded to eProcurement Portal * Category: E= 75 Lakhs - Lessthan= 100Lakhs F= 50Lakhs - Lessthan 75 Lakhs G = 25Lakhs - Lessthan 50 Lakhs H = 10Lakhs - Lessthan 25 Lakhs I = 5Lakhs - Lessthan 10 Lakhs J = 2Lakhs - Lessthan 5 Lakhs K = Lessthan 2Lakhs
I.T Returns for past 03 assessment years
Annual financial turn over during the last 3 years, ending 31st March 2025
TURN OVER IN Rs.
Pls Enter Turn over in Rupees for all the 3 years
ESI & PF Nos with proof
Remarks if any
Bank(s) details: [Copy of ECS and cancelled cheque leaf to be uploaded]
Related Document to be Uploaded to eProcurement Portal (Note Canceled cheque leaf to be uploaded)
Solvency Certificate Details
Pls Enter Details to 'Name of the Bank' , 'Date of Issue','Value in Rs
Experience of having successfully completed similar works during last 7 years ending on the previous day of submission of tender [Work experience certificate may be uploaded] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated cost. (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated cost. (iii) ONE similar completed work each costing not less than the amount equal to 80% of Amount put to the tender.
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Please enter Details for Work No 1
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Pls Enter Details for Work No II
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Pls Enter Details for Work No III
Details of person holding the power of Attorney (If different from contact person)
Related Document to be Uploaded to eProcurement Portal
Pls Enter Details for Person holding Power of Attorney
DECLARATION I
DECLARATION II
Pls Accept the Delaration II
Specification
Removing / transporting the surplus excavated earth including debris, vegetation waste, concrete waste, etc., to a distance upto 5000m from HAL premises to contractor's own yard including loading, unloading, depositing, spreading, levelling etc, all complete as per directions of Engineer-in-charge.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas in all kinds of soft / hard soil for foundations, footings, column pedestals or members as per the drawing or as per directions of EICetc., (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including removal of vegetation and in-equalities, shoring, strutting for protecting the sides of foundation if required, removing slips or falls in excavation, forming steps in sides of deep excavations and their removal or covering up, levelling, ramming the bottom of excavation, getting out and disposal of excavated earth lead upto 50 m for all lifts with all labour, tools & tackles, plant & machinery, hire & fuel charges etc.,all complete as directed by Engineer-in-charge.
Returning /Filling in available useful excavated earth (excluding rock) free from salts, organic or other deleterious matter (Other than black cotton soil & rock etc.) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by watering, breaking / removing clods exceeding 50 mm, ramming and consolidation etc., with all labour, tools & tackles, plant & machinery, etc.,lead up to 50 m and lift upto 1.5 m etc, all complete as per directions of Engineer-in-charge.
Providing and laying in position cement concrete for all work up to plinth level including flooring of 1:2:4 (1 cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources), etc, all complete as per directions of Engineer-in-charge.
Providing, mixing and laying in position cement concrete (1:4:8) derived from natural sources of required thickness using 40 mm down graded hard stone/granite aggregate in accordance with IS 456 in all works up to plinth level, including mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions etc, all complete as directed by the Engineer-in-Charge.
Supplying, mixing and placing plain cement concrete (1:2:4) of required thickness using 20 mm nominal size down graded hard stone/granite aggregate in accordance with IS 456 in Cills, fillets, coping,etc upto floor five level, including formwork, mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions etc., but excluding the cost of centering, shuttering and finishing, all complete as directed by the Engineer-in-Charge.
Centering and shuttering including strutting, propping etc. and removal of form work for PCC items like bases for columns/footings etc, all complete as per directions of Engineer-in-charge.
Formwork (Centering and shuttering including strutting, propping etc, and removal of form) for the following RCC members which are defined as below, in fair finished by providing timber, wooden planks, runners / M.S. sheets with all supports, struts, braces, wedges, scaffolds, bracings, ladders, gangways, dressing with oil including M.S. bolts nuts and washers, temporary openings, filleting for a stop, chamfered edges, internal / external splayed, rounded angles or grooves for forming throating including making temporary openings in the forms for pouring concrete etc., all complete as directed by the Engineer-in-Charge for the sub-items mentioned below. Note : Formwork material is contractor's own property and shall be removed after completion of work.
Foundations, footings, bases of columns,bed concrete,ramp concrete, pedestal etc. for mass concrete
For Roofs, landings,suspended floors, Slabs supported on walls, roofs, landings, balconies, access platforms, Gutters, decks etc up to stndard height 3.60m/3.75m and below.
Plinth beams, Lintels, Beams, room beams, beams,girders, bressumers and cantilevers etc
For Columns, Pillars, Piers, etc
Chajja, Weather shade,Canopies, Corbels etc,including edges
Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
Edges of slabs and breaks in floors and walls under 20cm wide
Supplying, straightening, fabricating (cutting & bending), placing in position and binding steel reinforcement of TMT bars of not less than Fe 500 D conforming to IS 1786 for all concrete reinforcment members / works above/below plinth level, including cutting to length, bending to shape required, including cranking, bending spirally for hooping for column, hooking ends and binding with mild steel wire (Annealed) not less than 0.9 mm dia or securing with clips, including fixing and bracing, wastage, welding, supporting or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it etc., complete all as per specifications, drawings and as directed by the Engineer-in-Charge. Note : a) Only authorized laps, chairs etc. shall be considered for measurement. b) The exposed Reinforcement bars shall be coated with cement slurry.
Providing and laying in position ready mixed or site batched M25 Grade with minimum cement content of 350 kg/m3 design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, consolidation, levelling, curing, scaffolding, all materials, labour, carriage for all leads & lifts; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge. Note: (i) Site design mix to be obtained from Govt. / NABL laboratory for site batching concrete. (ii) Small quantity is as approved by EIC in volumetric proportion.
All works upto plinth level including necessary openings and packing if any for laying pipes, cables etc.
All works above plinth level upto floor V level including necessary openings and packing if any for laying pipes, cables etc.
Providing and fixing expansion hold fasteners with threaded dia 10 mm each on C.C. /R.C.C./Masonry surface backing including drilling necessary holes and the cost of bolt of Wedge expansion type etc, all complete as directed by the Engineer-in-Charge.
Providing and fixing M.S. grills of required pattern to steel windows/ walls/ in frames of windows,ventilators,e.t.c and approved design using MS structurals such as M.S flats, angles, round/square bars etc., including necessary cutting, welding, embedding in concrete, masonry etc.,including priming coat with approved steel primer etc, all complete as directed by the Engineer-in-Charge.
Supplying, fabricating and fixing second class teak wooden plain, solid, straight chowkats and frames of doors, windows, partitions, wall panelling frames and other frames, wrought framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints and fixed to wall or in position with hold fast lugs or with dash fasteners of required dia & length etc., all complete as directed by the Engineer-in-Charge. Note:Hold fast lugs or dash fastener shall be paid separately.
Providing, fabricating and fixing 35mm thick flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood & lipping with 2nd class teak wood battens 25 mm minimum depth on all edges and well matched commercial 3ply veneering with vertical grains or cross bands including ISI marked Stainless Steel butt hinges with necessary screws and face veneers on both faces of shutters and provision of rebates,suitable blocks for taking mortice locks, latches or other fittings, fitting to frames/chowkats etc., all complete as directed by the Engineer-in-Charge. Note : Fittings / hardware shall be paid separately.
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) etc, all complete as directed by the Engineer-in-Charge.
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc, all complete as directed by the Engineer-in-Charge.
Providing and fixing bright finished brass 100mm mortice latch and lock of 6 levers, vertical type, and a pair of lever brass handles of approved quality, polished bright of approved manufacture to door with all necessary screws, bolts, nuts and washers of approved manufacture, etc., all complete as directed by Engineer-In-Charge.
Supplying and fixing the Polished (bright finished) brass barrel type tower bolts 250 mm long X 10 mm with barrel of extruded sections of brass, of approved make and rolled or drawn brass bolt, design to door with all required screws, bolts, nuts, washers etc., conforming to IS 204 (Part 2) all complete as directed by the Engineer-in-Charge.
Providing and fixing bright finished brass butt hinges (125 X 70 X4 mm) with necessary screws etc. all complete as directed by Engineer-In-Charge.
Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.1. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture’s specification etc, all complete as directed by the Engineer-in-Charge. [ With 75 mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming to IS: 2095: (part I): 2011 (Board with BIS certification marks) ]
Providing and fixing Cupboard Door Shutter with 19 mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2 mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge. (Payment of providing and fixing autoclosing hinges shall be paid separately)
Providing and fixing 19 mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS : 710 of approved brand boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws etc, all complete as directed by the Engineer-in-Charge.
Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc, all complete as directed by the Engineer-in-Charge.
Providing and fixing 200mm stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge.
Providing and fixing stainless steel (Grade 304) tubular section for door handles, latch fittings etc. for frame less toughned glass door of approved size/design by welding etc. made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.), all complete as directed by the Engineer-in-Charge.
Providing and laying Double Charged vitrified floor tiles polished finish size of tile Size of 600 X600 mm or nearest available size in floors over a screed of cement mortar (1:4) 20 mm thick for Paper Joint ( Thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement: 4 course sand), including grouting the joints with grey cement slurry @ 3.3 Kg/Sqm including grouting the joints with white cement and matching pigments etc, all complete as directed by the Engineer-in-Charge.
Providing and laying Vitrified tiles in Skirting over a screed of cement mortar (1:3) -Size of Tile 600x600 mm or nearest size available (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc, all complete as directed by the Engineer-in-Charge.
Providing, fixing, testing and commissioning single socketed pipes of 110mm dia, on wall face/in floors unplasticised Rigid PVC rain water pipes of 6 kg/cm² SWR grade and of approved make conforming to IS : 13592 Type A, including jointing together with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion and all necessary fittings & specials, bends, branches, sockets, clamps, pipe cutting and wastages, cutting and making good the walls/floors, connecting to existing lines etc., all complete as directed by the Engineer-in-Charge.
Providing, applying and laying 12 mm thick cement plaster work in for internal/ External areas of Ceilings, Chajjas etc in CM(1:4) including forming grooves n.exc 10mm wide and n.exc 10mm deep as per requirement as directed including preparation of surface by hacking etc., at all levels with necesary materials, labour, scaffoldings, curing, tools and tackles, plants etc., threading if any as directed, all complete as directed by the Engineer-in-Charge.
Providing, applying and laying cement mortar (1:6) plastering 15 mm thick on brick/solid blocks/concrete surfaces, finished even and smooth with trowel for Internal/External walls etc., including supply and fixing of hexagonal chicken mesh minimum 150 mm wide having opening 20 mm x 20 mm of 26 gauge at juncitons of concrete & brick work or between different material, including making grooves as per the requirement n.exc 10mm width and n.exc 10mm deep with necesary materials, labour, scaffolding, curing, tools and tackles etc., at all heights, all complete as directed by the Engineer-in-Charge.
Providing, applying and laying 18 mm thick cement plaster work in two coats for external areas as directed. First coat 12 mm thick in cement mortar (1:5) made rough to recieve top coat, second coat 6 mm thick in cement mortar (1:6) , final surface finished with a floating coat of neat cement after necessary preparation of surface, at all levels including supply and fixing of hexagonal chicken mesh minimum 150 mm wide having opening 20 mm x 20 mm of 26 gauge at juncitons of concrete & brick work or between different material, with necesary materials, labour, scaffoldings, curing, tools and tackles, plants etc., threading if any as directed, all complete as directed by the Engineer-in-Charge.
Painting newly plastered external surfaces with two or more coats applied at 1.43 litre/10 sqm/ as per manufacturer specifications of 100% premium acrylic emulsion paint having VOC less than 50 grams/ litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint with silicon additives of approved make, colour, shade, tint & pattern at all levels, over and including a coat of approved acrylic primer including preparing the surface by removing loose dirt and any organic growth, filling of cracks, necessary scaffolding etc., all complete as directed by the Engineer-in-Charge. Note:The paint shall have anti-algal, anti-fungal, UV resistant & anti-tarnishing qualities with 100% acrylic base and silicon or elastomeric additives.
Painting Steel surfaces of any description with two coats of synthetic enamel paint of approved colour,brand and manufacture to give an even shade, including preparation of surface by rubbing with fine grade of abrasive paper to ensure smooth etc., all complete as directed by the Engineer-in-Charge.
Painting newly plastered interior surfaces with two coats of premium acrylic emulsion paint of interior grade having VOC (Volatile Organic Compound) content less than 50 grams/ litre conforming to IS 15489, of approved make, brand, colour and texture, shade, tint, manufacture & pattern at all levels including non-reflective paint whereever required etc., including preparing the surface by removing loose dirt and any organic growth, smoothening the surface by using suitable emery paper, filling crevices and finishing even and smooth by providing and applying white cement based putty of suitable thickness in 2 coats of approved brand and manufacture over the plastered wall surface and followed by the applying priming coat with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content With water thinnable cement primer on applied putty having VOC content less than 50 grams/litre, necessary scaffolding etc., all complete as directed by the Engineer-in-Charge.
French Polishing on wood work on New work with two or more coats including a coat of wood filler, all complete as directed by the Engineer-in-Charge.
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.[ Nominal concrete 1:3:6 or richer mix (including equivalent design mix).
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking at designated place/ handing over to stores department metres etc, all complete as directed by the Engineer-in-Charge.
Dismantling roofing, cladding including ridges, hips, valleys and gutters etc., made out of GI Sheeting/Corrigated GI Sheeting etc., and stacking the material at designated place/handing over to stores deptrtment. Flat Area will be measured etc, all complete as directed by the Engineer-in-Charge.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved etc, all complete as directed by the Engineer-in-Charge.
Providing and laying design mix cement concrete of M-30 grade manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixer in roads/hardstandings/ramps using cement content as per design mix, using coarse sand and graded stone aggregate of approve size in appropriate proportions as per approved & specified design criteria, laying over reinforcement, spreading and compacting mechanically by using needle vibrator, levelling to the required slope/camber, finishing with required texture including steel form work with sturdy M.S channel sections, curing making provision for contraction/expansion joints, construction and longitudinal joints ( 10mm wide X 50mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealent etc, all complete as directed by the Engineer-in-Charge.
Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) per cm depth per cm width per metre length.
Providing and fixing Power Coated Aluminium Fixed Portion i.e Door Frame, Window Frame for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
Providing and fixing Power Coated Aluminium section for Movable Portion i.s Shutters of Doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. The rates is including cost of accessories like F Gear for lsiding doors etc., (Glazing, paneling and dash fasteners to be paid for separately) :
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) with float glass panes of 8 mm thickness.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock patches etc.to be paid separately). The rate is inclusive of Lock and Key. S.S Handles and Lock strip will be paid in Kg in the relavent items.
Providing and laying integral cement based water proofing treatment With average thickness of 120 mm and minimum thickness at khurra as 65 mm. including preparation of surface as required for treatment of roofs, (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.
Providing and fixing mineral fibre false ceiling tiles With 16 mm thick beveled tegular mineral fibre false ceiling tile (dune Max Variety) at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance of 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the Engineer-in-Charge.
Providing and laying factory made Precast concrete solid blocks built in CM(1:6) and of 200 mm thickness of grade M10 made of Normal resources/C&D Waste from approved manufacturer in superstructure above plinth level up to floor V level, all complete as directed by the Engineer-in-Charge .
Providing and laying half block masonry with factory made Precast concrete solid blocks built in CM(1:4) and of 100 mm thickness of grade M10 made of Normal resources/C&D waste from approved manufacturer in superstructure above plinth level up to floor V level, all complete as directed by the Engineer-in-Charge .
Supplying and fixing Motorized G.I. rolling shutter, made of approximate size 3 X 3 m and approved make. The curtain shall be constructed from Tata Bluescope/JSW 150 gsm single skinned galvalume steel laths with natural finish of min. 1.25 mm thickness and interlocking distance of min 75mm. Side guides shall be made of min. 2 or 3.15 mm thick heavy duty TG Galvanised steel, as per the site requirement, along with necessary fixtures like cleats(spacing shall not exceed 0.75m) or supports brackets for attachments to the walls or column by screws or bolts and necessary seals.The size of the guide channels shall be conforming to Is:6248-1979. Single piece G.I. Heavy duty mild steel suspension shaft along with roller of sufficient diameter with springs shall be provided along with necessary hexagonal bracket plate of min 3.15mm thickness, size conforming to Is:6248-1979 and square bar, if necessary. The provision of Pressed galvalume steel hood cover with reinforced bracket as required to suit the shutter width and motor cover with natural finish of min. 0.9 mm thick and of reuired shape along with necessary fixtures and stiffeners like angle cleats, angle or flat stiffeners,etc shall be provided. Bottom profile shall be of G.I. plate with angle stiffner. The bottom rail shall be fixed with extruded rubber bottom seal that shall seal against the floor when the door is fully closed.
Providing and fixing factory made UPVC Double Glazed Side Openable window with mullion, transome of suitable size. for height upto 1.50 metre, including all the necessary fixures and fittings along with all the screws, fasteners,e.t.c, all complete as approved and directed by the Engineer-in-Charge. The DGU shall be ( 6mm Toughned Glass + 12mm Airlock + 6mm Toughned Glass) with nenecssary frame for the DGU, Hinges for fixing to Frame. The shutter shall be with Mosquito Mesh. The gap between the walls and UPVC window shall be properly sealed with Silcone sealent. The rate quoted shall be all inclusive of handles, hinges, etc., all complete from the approved list of UPVC windows.
Supplying and Fixing of Zebra blinds (Z-type) with glossy finish for indoor windows manufactured from Hunter Douglas,Smartwings,Bringnox or any other equivalent standard makes consisting of control unit idler, head of rail, roller tube, bottom rail operating chain, brackets and clamps/nuts/bolts/ of approved colour/ pattern which are foldable and washable including necessary supporting hangar holders /screws and all complete as directed by the Engineer-in-Charge.
Rupees Sixty Six Lakh Four Thousand Five Hundred Seventy Seven and Thirty Eight Paise Only
Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body including trim as per CPWD
Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power onsumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim as per CPWD.
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
Supply, fixing to existing MS perlins/RCC roof at approx. 6 mtr height, including using suitable MS angle frame work with required fixing hardwares etc., as per site requirement, testing & commissioning of industrial type Flameproof type LED Flood light fixture of wattage not exceeding 80 Watts.The technical parameters of Flame proof Flood light fixtures are as below: The lumiare should have Lumen efficacy >100 lm/watt and lumen output not less than 8000 lumens with symmetric beam Angle 90 degree using suitable optics, PF >0.9 and Colour temperature shall be >6500K, IP66 rated operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections between driver and lighting fixtures. Flameproof cum Waterproof LED Flood light fitting Flat Type COB Model Multipile Chip in cast Allum Alloy LM-6 Construction suitable for 80 W LED flood light fixture certified by CIMFR Dhanbhad for gas group I I A , I I B and I I C for zone ZONE 1 & 2 & Zone 21 & 22 and other standard accessories complete in all respects and as directed by Engineer in-charge. The Flame proof Flood Light fitting shall be of model SUDHIR make Cat no: WG/1240 or Equivalent model in other approved makes. LED used in the lighting fixtures shall be one of the HAL approved make.Test certificate for luminares and for LED shall be produced.
Supply, fixing, testing & commissioning of the following factory built powder coated Double door MCB/MCCB DB of any approved make fabricated out of M.S. sheet steel enclosure & necessary cutouts for operating the MCB knobs & comprising of 200 amps tinned copper busbars & earthing bus with tapped holes including internal wiring with stranded copper PVC wires or suitable size copper strips etc. & fixing the DB in flush with wall/ on wall as per site requirement with necessary M.S. angle supports, chipping the wall and replastering to smooth finish etc., wherever required as per site condition, complete in all respects, as directed by Engineer-in-charge and comprising the following as detailed below:
4 way (4 + 12), Horizontal Double door MCB DB
6way VTPN MCCB DB.
Supply and fixing 6A to 32 A rating, SP 214V 10kA, "C" curve, miiniature circuit bracker suitable for inducive load of following poles in the exesting MCB DB complete with connections, testing and commessioning etc., as required.
Single pole
Triple pole
Triple pole and neutral
Supply, laying, testing & commissioning of following size Aluminium LT armoured power cables.
4CX 16 Sqmm Aluminium armoured conductor
3.5CX 70 Sqmm Aluminium armoured conductor
3C X 2.5 Sqmm Copper armoured conductor LT control Cable
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE armoured aluminium conductor cable of 1.1 KV grade as required
4C X 16 sq. mm Al arm cable
3.5 CX 70 Sqmm Al arm cable
Wiring for light point / fan point / exhaust fan point/call bell point from nearest switch box with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, fan regulator, modular plate, ceiling rose, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (as per detailed CPWD specifications for Group C wiring)
Wiring to single light point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects.
Wiring to two light point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects.
Wiring to three light point controlled by 1 No 6A, 250V gr. flush modular type SP switch complete in all respects.
Wiring to ceiling fan point controlled by 1 No. 6A, 250V gr. flush type modular SP switch, 2 module type electronic five stepped speed regulator etc., complete in all respects.
Supplying and fixing following suitable size GI Box with modular plate and cover on front on surface or in recess, including providing and fixing 3 pin 5/6A modular socket outlet and 5/6 A modular switch, connections etc., as required.
Supplying and fixing following suitable size GI Box with modular plate and cover on front on surface or in recess, including providing and fixing 6 pin 5/6A & 15/16A modular socket outlet and 15/16 A modular switch, connections etc., as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supply, installation, testing and commissioning of 1row 12modules weather proof DB/cabinet mounted at suitable height on the wall using suitable size MS angle frame work with painting as per EIC, with cable entry knock-outs, including rigid support for all components, Din channel, required fasteners, necessary interconnections, dummy plates, totally enclosed, dust and vermin proof and degree of protection shall not be less than IP-65 complete in all respects and as directed by Engineer-in-charge. The DB/Cabinet may be of Hensel make of model no KV9112M or equivalent in Legrand/ Schneider/ Hagar make only. Note: MS supports will be paid separately.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
2 Module
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
3 x 2.5 sq. mm (For lighting ckt from DB to Switch box, For 6A power Points)
3 x 4 sq. mm(For 16A&20A power points)
Supply, Fixing, in the existing GI /PVC box as per site requirement, testing & Commissioning of 1 No. Twin RJ-11 telephone socket outlets with shutter with necessary interconnections complete as directed by Engineer-in-charge.
Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supply & drawing of 4 pair Unarmoured 0.5mm telephone cable
Supply & fixing on wall/grouted to floor upto 1200mm above ground level as per site requirement using suitable size MS angle iron frame work finished with two coats of enamel spray paint over a good primer & providing 10 pair krone type telephone connector junction box including krone connector with necessary mounting frame housed in suitable size FRP box with hinged lockable cover complete in all respects.
Supply, laying in the already excavated cable trench/existing duct/fixing on wall/cable tray/iron structure using suitable clamps etc./ encasing in pipe, testing and commissioning of 10 pair jelly filled armoured copper conductor of 0.5mm dia polyethylene insulated cover, twisted into pairs, colour coded, pairs laid up, fully filled with petroleum jelly as a moisture barrier, core wrapped with non-hygroscopic polyester tape to contain the jelly, covered with aluminium poly-laminates screen, polyethylene sheath extruded over aluminium screen, polyethylene tape over the above sheath, armoured with galvanised steel tape and outer polyethylene sheath underground telecommunication cable including both end terminations on the existing krone type junction box complete in all respects.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
20MM PVC Conduit
25MM PVC Conduit
Supply, Fixing in flush with wall/on Aluminium partition as per site condition, testing & Commissioning of 2 nos of RJ-45 modular type sockets for Data points including supply of suitable size modular type MS/PVC surface mounting box with base plates, glossy finish front covers, labelling etc., with necessary interconnections and chipping the wall, replastering to smooth finish etc., wherever required complete as directed by Engineer-in-charge.
Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non-Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required as per CPWD specification
Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
6U Rack
Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
CAT 6 Copper Patch Cords of length 1m (3ft)
CAT 6 Copper Patch Cords of length 3m (10ft)
Supply, fixing/embedding on wall/ ceiling flame proof 4 way junction boxes of entry size 3/4" ET, 100mm dia, 40mm depth of LM6 material including necessary chipping of the wall and replastering to smooth finish etc. as per site conditions and as directed by Engineer In-Charge.
Supply & providing flame proof double compression cable glands for 3Cx2.5Sq.mm copper conductor PVC insulated 1100V gr. armoured LT cables by employing necessary glands, end terminals, bolt & nuts etc., complete in all respects.
Earthing
Supply, providing and Fixing Cast Iron Pipe earth station confirming to IS 3043 complete with 2750mm long, 100 mm Inner Dia(ID),13mm thickness CI Pipe, with 2 part clamp made out of G I flat 50 x 6 mm continuously welded around the pipe using cast iron welding electrodes as per drawing. The cost also incudes excavation for earth pit, providing & laying homogenous mixture of charcoal lumps, salt & sand all around the pipe as per specification, supplying and fixing of RCC Collar of size 450 mm dia, 450 mm height and 50 mm thick over Cement concrete base of minimum size 150mm width & 100mm thick all around below collar shall be provided using 1:2:6 CC after necessary excavation, refilling of soil, consolidating, ramming, leveling of soil etc., supplying & fixing the label board(MS Plate of size 300mmx200mmX2mm) welding to the electrode complete as per specification, std drawing, instructions of EIC.
Supply, fixing & connecting the 50X6mm size G.I strip on wall / clamping to the existing duct wall / fixing on steel structures/ laying 2 ft. below the ground level with necessary excavation, concrete cutting & re-concreting, refilling, consolidation & levelling of soil after laying for interconnection between the earth pits and the LT & HT panels earthing & Transformer body earthing as directed by Engineer-in-charge. Note:- Excavation, concrete cutting & re concreting will be measured separately.
Supplying & laying 25 mm X 5 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply and laying of 50mm dia, PE-80, PN6 ISI marked HDPE pipe confirming to IS 4984:19955 including suitable jointing using welding as required in the excavated trench/duct/at road crossings for encasing cables complete in all respect as directed by Engineer-in-charge.
Excavation in all types of soil for Cable trench including refilling, consolidating of soil after laying the cable including ramming and levelling to smooth finish as per the Technical specifications enclosed and as directed by the Engineer-in-charge.
Demolishing cement concrete (1:3:6 or leaner mix) manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Re-concreting the cut portion/closing the dummy cable duct at same area with 1:2:4 cement concrete by employing 20mm graded aggregate granite to smooth finish including curing and form work if any complete in all respects and as directed. As per CPWD Specification.
Rupees Seven Lakh Seventy One Thousand Three Hundred Seven and Fifty One Paise Only
Two Loop Panel.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required
Supplying, installation, testing & commissioning of fault isolator complete with base as required
Supplying, installation, testing & commissioning of addressable fire control module complete as required
Supply, Installation, testing and commissioning of Auto Dailer including the cost of mounting accessories with addressable control module integrated with main control panel with minimum 10 telephone nos. connectivity complete as directed by Engineer-in-charge. : Rate-Rs.(12320+1620) Quotation from : Nadiya Technology Solutions Pvt Ltd
Supply, Installation, testing & commissioningof Triple sensor Flame Detectors with UV/IR detection capacity with Flame proof / Explosion proof enclosure type, Flickering LED, 4 wire system. 2 wire for Input Supply & 2 wire suitable to connect standard Fire Alarm as per technical specification and shall comply to BS-5839/EN54/IS2189 standards for installation and product shall be EX & IEICEx Approved.
Supplying & laying of 2x1.5 sqmm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Rupees Four Lakh Seventy Four Thousand Six Hundred Fifty One and Eighty Six Paise Only
OUTDOOR UNIT: Supplying, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load.The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39°C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 7.4, Capacity > 40 and <70 ISEER 7.5, Capacity > 70 ISEER 7.6 for Super ECSBC Building) For Cooling or Heating or Both Note: Make: Diakin/Any other make which satisfies the specification.
12 HP ODU
INDOOR UNIT: Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) Note: Make: Diakin/Any other make which satisfy the specification.
Design, Supply, installation, testing and commissioning of suitable size hard/soft refrigerant copper pipe as required with required pipe fittings , accesories, filter drier and couplings by good quality pipe joints which laid between ODU and IDU The Minimum copper pipe gauge shall be as per the gauges indicated by manufacturer. The Pipe sizes to be used as per OEM design recommendation. The Refrigerant pipe shall be insulated with Class O nitirle rubber of 19 mm thick for Gas line and 19 mm thick for liquid line. The piping shall be laid on walls / roof / ceiling well supported at specific intervals with metallic support, Cable tray with cover and required hardwares etc., for fixing copper pipes. All the necessary accessories, jointing / brazing etc shall be carried out as required. The pressure testing of refrigerant piping has to be done as per manufacturer design recommendation. All the copper fittings shall be suitable for R 410 A/R 407R 134a//R-32 refrigerant. . Make: Mandev/Piyush/Totaline (Note: 1. Irrespective of diameter both gas and liquid piping shall be measured as a single item. The single item measurement comprising of gas line, liquid line, insulation and its accessories. Contractor make a note of it and quote accordingly. 2. Before commencement of work, shop drawing to be submitted to OIC/EIC for approval. )
Design,supply,Installation testing & commissioning of suitable sizes as per OEM recommonadation not less than 2mm thick CPVC drain water / fresh air arrangement pipe including U-traps, vlaves for AHU drain,reducer, bends, collars & elbow etc, all complete and duly insulated with 9 mm thick tubular insulation of closed cell elastomeric nitrile rubber as required.The PVC drain water pipe/fresh air pipe shall be complete with fittings, accessories and duly insulated using bends, elbows, tees, wall sleeves, hangers, supports, anchors etc.(Note:.1 Pipe used for fresh air intake to IDU shalll be coverd with mesh. 2. Necessary wall openings and closing the same using cement mortar and matching paint finish after taking out pipes is included in the scope of work. ) Make: Supreme/Finolex/Hycount/Saroplast
Supplying, laying, testing & commissioning of following size and LT Control Cables - unarmoured Copper Conductor of 1.1 KV grade confirming to IS: 7098 ( part-I)/1998 with upto date amendment including stacking at site, proper storage complete etc. as required
2C X 1.5 Sqmm Copper unarmoured conductor LT control Cable.
Rupees Four Lakh Ninety Eight Thousand Two Hundred Twenty Five and Forty Paise Only
Rupees Eighty Three Lakh Forty Eight Thousand Seven Hundred Sixty Two and Sixteen Paise Only
Approximate Amount Put to Tender
Rupees Fifteen Lakh Two Thousand Seven Hundred Seventy Seven and Eighteen Paise Only
Rupees Ninety Eight Lakh Fifty One Thousand Five Hundred Thirty Nine and Thirty Four Paise Only
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
TN49.pdf
pdf • 0.63 MB
49TBF.pdf
pdf • 5.40 MB
49PQF.pdf
pdf • 0.20 MB
49PBF.pdf
pdf • 0.61 MB
CivilTenderDrawings.pdf
pdf • 1.10 MB
ElectricalandMechanicalTenderDrawings.pdf
pdf • 2.42 MB
49ECSForm.pdf
pdf • 0.48 MB
49UNDERTAKING.pdf
pdf • 0.57 MB
49CHECKLIST.pdf
pdf • 0.19 MB
49PQ.xlsm
xlsm • 0.03 MB
49PB.xlsm
xlsm • 0.63 MB
AMD24092026.pdf
pdf • 0.08 MB
AMD.pdf
pdf • 0.09 MB
AmdD5249.pdf
pdf • 0.09 MB
49EMDWAIVEDOFF.pdf
pdf • 0.16 MB
AMD03092026.pdf
pdf • 0.08 MB
AMD5249.pdf
pdf • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .