Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC 22 319 GALI NO 5 MAHABIR PARK BAHADURGARH 124507 HARYANA | JHAJJAR | HARYANA | 124507 | L1 | Accepted-AOC lowest | |
| 2 | L2₹35.0 L+₹3.0 L (9.26%)Rejected-Finance | L2 | Rejected-Finance RATE HIGH | |
| 3 | L3₹35.3 L+₹3.3 L (10.2%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-Finance RATE HIGH | |
| 4 | L4₹39.0 L+₹7.0 L (21.9%)Rejected-Finance | L4 | Rejected-Finance RATE HIGH | |
| 5 | L5₹40.1 L+₹8.1 L (25.2%)Rejected-Finance SHOP NO 11 18 CITY CENTRE 930 931 SYNAGOGUE STREET PUNE 01 | L5 | Rejected-Finance RATE HIGH |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
10 Apr 2025, 6:00 pmClosed
GE South Pune
NO 1 GEN BHAGAT MAR PUNE 40
8669 MAINT REPAIR REPLACEMENT OF INTERNAL ELECTRIFICATION AND OTHER ALLIED E M WORKS AT CARIAPPA ENCLAVE NAPIER ROAD STAVELY ROAD LAWRENCE ROAD KT LINE OLD TELELINE ALC MINTSD AND OTHER CONNECTED AREA UNDER AGE E M I OF GE SOUTH PUNE
2025_MES_702024_1
8669 GE SOUTH PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE South Pune
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹98,000
Yes
18 Jun 2025
20 Mar 2025
12 Apr 2025
20 Mar 2025
10 Apr 2025
4 Apr 2025
Amount
Labour only for repair / maintenance of internal light fitting of any type like tube lights / wall bracket light fittings / ceiling lights / bulk head light / mirror lights etc in its position, testing all the components / parts, wiring etc, identifying the defects and replacing the defective components like tube rod, side holders, holders, lamps etc by deploying 01 No. skilled electrician complete all as directed by Engr-in-charge. Note: (i) Attending of 01 No. complaints / defects and make it functional shall be measured as one job. (ii) The spare parts like driver, switch, sockets and other accessories, connection wire, capacitor etc. required at site will be provided by Engr-in-charge free for fixing only. (iii) The contractor's electrician will report to concerned JE E/M at 0900 hrs daily to collect the list of defects / complaints and will be submitted the completion report on following day before 0900 hrs to the JE E/M. (iv) The contractor has to rectify the defects / complaints and make the light fittings functional within 24 hours from the time the list of defective lights is handed over to him / his rep by the concerned JE E/M. In case the light fitting is not made functional for whatsoever reason within the specified time limit, an amount of Rs 100/- per such defect / complaint per day will be recovered from the amount due to him through RAR / Final Bill. (v) The contractor shall maintain proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every light fitting and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for.
S&F of PVC / polycarbonate lamp holders batten/Angle type, complete all as specified and directed
S&F of modular five step type fan regulator 120W, 2 module , complete all as psecified and directed.
S&F of modular switch piano type 10 amps one way one module , complete all as psecified and directed.
S&F of modular switch piano type 20 amps one way one module with neon indicator , complete all as psecified and directed.
S&F of modular Socket, 6A - 2/3 pin 2 module , complete all as psecified and directed.
S&F of Socket, 6/16A - 2/3 pin 2 module, complete all as psecified and directed.
S&F of 1 module Blanking plates complete all as specifed and directed
S&F modular Bell push, 10 Amp with neon indicator one module, complete all as psecified and directed.
S&F of modular switch piano type 10 amps Two way one module, complete all as psecified and directed.
S&F of switch piano flush type 5 Amps SP one way, complete all as psecified and directed.
S&F of switch piano type 15 Amps SP one way, complete all as psecified and directed.
S&F of switch socket combination 5/6 Amps flush mounted 5 pin multi purpose, complete all as psecified and directed.
S&F of switch socket combination 5/15 Amps flush mounted 3/5 pin multi purpose, complete all as psecified and directed.
S&F of socket 5/6 Amps flush mounted 3 pin, complete all as psecified and directed.
S&F of socket 5/15 Amps flush mounted 3/5 pin multi purpose, complete all as psecified and directed.
S&F for ceiling rose, 2 to 3 terminals /PVC/Polycarbonate, isolated body, complete all as psecified and directed.
S&F of fan regulator electronic five step type suitable for BLDC 1200/1400 mm sweep fan as per the sample provided by the Engr-in-charge, complete all as psecified and directed.
S&F of door bell AC 230 volts single phase ding dong type, complete all as psecified and directed.
S&F of bell push, flush type 5 Amps, complete all as psecified and directed.
S&F of switch socket combination with box 5/6 Amps flush mounted 5 pin multi purpose, complete all as psecified and directed.
S&F of switch socket combination with box 5/15 Amps flush mounted 3/5 pin multi purpose, complete all as psecified and directed.
Taking down carefully existing point wiring any type (light/fan/socket) including all accessories wire, casing caping /conduit, screws etc and making good the disturbed surfaces, complete all as specified and directed
M&L for point wiring with 1.5 sq mm copper conductor FRLS (multi-strand) PVC insulated ISI marked unsheathed cable and including surface, Non metallic rigid PVC casing capping double lock type/PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unsheathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type switches, sockets, fan regulator etc for One light/Fan point controlled by one way switch 6 Amps 240 volts, complete all as specified and directed.
All as per item no. 24 above but One 3 pin 6 Amps socket out let point on independent board, complete all as specified and directed
All as per item no. 24 above but One 3 pin 6 Amps socket out let point on same board, complete all as specified and directed
All as per item no. 24 above but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq mm size, complete all as specified and directed
All as per item no. 24 above but One light point controlled by Two 2-way switches, complete all as specified and directed
M&L for point wiring with 2.5 sq mm copper conductor FRLS (multi-strand) PVC insulated ISI marked unsheathed cable and including surface, Non metallic rigid PVC casing capping double lock type ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unsheathed FRLS cable size 2.5 sq mm copper conductor as earth wire to common earth dolly including PVC box , modular cover plate with frame suitable for 15 Amps socket and switch outlet power point independent circuit, complete all as specified and directed.
M&L for securing loose wiring and repair to point wiring with including necessary rigid non metallic PVC casing caping double lock type/ PVC conduit ISI marked of size not less than 25 mm inclusive all accessories complete as specified and directed.
S&F of flexible conduit pipe ivory grey in colour of dia not less than 25 mm complete all as specified and directed.
M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 1.5 Sqmm, 1100 Volts grade in and including PVC Conduit /casing caping medium grade not less than 25 mm complete with conduit accessories and copper cable 1.5 sqmm continuous earth wire complete all as specified and directed. Note:- Two runs of 1.5 Sqmm cable with 01 run of 1.5 Sqmm earth wire along with casing caping / conduit shall be measured as one RM
M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 2.5 Sqmm, 1100 Volts grade in and including PVC Conduit /casing caping medium grade not less than 25 mm complete with conduit accessories and copper cable 2.5 sqmm continuous earth wire complete all as specified and directed. Note:- Two runs of 2.5 Sqmm cable with 01 run of 2.5 Sqmm earth wire along with casing caping / conduit shall be measured as one RM
M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 4 Sqmm, 1100 Volts grade in and including PVC Conduit /casing caping medium grade not less than 25 mm complete with conduit accessories and copper cable 4 sqmm continuous earth wire complete all as specified and directed. Note:- Two runs of 4 Sqmm cable with 01 run of 4 Sqmm earth wire along with casing caping / conduit shall be measured as one RM
M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 6 Sqmm, 1100 Volts grade in and including PVC Conduit /casing caping medium grade not less than 25 mm complete with conduit accessories and copper cable 6 sqmm continuous earth wire complete all as specified and directed. Note:- Two runs of 6 Sqmm cable with 01 run of 6 Sqmm earth wire along with casing caping / conduit shall be measured as one RM
M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 10 Sqmm, 1100 Volts grade in and including PVC Conduit /casing caping medium grade not less than 25 mm complete with conduit accessories and copper cable 10 sqmm continuous earth wire complete all as specified and directed. Note:- Two runs of 10 Sqmm cable with 01 run of 10 Sqmm earth wire along with casing caping / conduit shall be measured as one RM
Taking down carefully sub main wiring of any type and size and making good disturbed surfaces , complete all as specified and directed.
S&F 1100 volts grade heavy duty cable 4 Sqmm two core PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0 m apart including 4mm suspension wire, one twin core cable flat or circular, complete all as specified and directed.
S&F in replacement factory made epoxy powder coated Distribution Board TP & N 4 way double door (VTPN MCCB DB ) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishes complete all as specified and directed Note:- MCBs/ MCCBs will be measured and paid separately under respective items of BOQ
S&F in replacement MCB DB 12 way SPN double door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated bus bar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size along with its accessories by removing from existing circuits and re-fixing the new DBs and circuits complete as required at site complete as specified and directed by the Engr-in-Charge. Note - MCBs will be measured & paid separately under respective items of BOQ
S&F in replacement MCB DB 8 way SPN double door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated bus bar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size along with its accessories by removing from existing circuits and re-fixing the new DBs and circuits complete as required at site complete as specified and directed by the Engr-in-Charge. Note - MCBs will be measured & paid separately under respective items of BOQ
S&F in replacement MCB DB 4 way SPN single door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated bus bar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size along with its accessories by removing from existing circuits and re-fixing the new DBs and circuits complete as required at site complete as specified and directed by the Engr-in-Charge. Note - MCBs will be measured & paid separately under respective items of BOQ
S&F in replacement MCB DB 4 way SPN double door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated bus bar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size along with its accessories by removing from existing circuits and re-fixing the new DBs and circuits complete as required at site complete as specified and directed by the Engr-in-Charge. Note - MCBs will be measured & paid separately under respective items of BOQ
S&F in replacement MCB DB 2 way SPN single door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated bus bar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size along with its accessories by removing from existing circuits and re-fixing the new DBs and circuits complete as required at site complete as specified and directed by the Engr-in-Charge. Note - MCBs will be measured & paid separately under respective items of BOQ
S&F MCCB with rating of 100 Amps, 415 Volts, 3 pole with 16 kA breaking capacity, thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity (Icu), MCCB should be with suitable spreaders and phase barriers for each terminals complete as specified and directed
S&F in repairs MCCB with rating of 63 Amps, 415 Volts, 3 pole with 16 kA breaking capacity, thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity (Icu), MCCB should be with suitable spreaders and phase barriers for each terminals complete as specified and directed
S&F in replacement of sheet metal enclosures single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 volts with all accessaries etc complete all as directed by Engr-in-charge.
S&F in replacement metal clad plug top 3 pin,10 Amps, 230 volts, ISI marked heavy duty suitable for geyser connection cord complete all as specified and directed.
S&F in replacement of neon lamp indicator square/round type after taking out old incl taking down old one complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.50 m below normal ground level connected to with and including earth lead of 4 mm dia GI wire up to 7.50m by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I(2009) connected to main switch board or main control board all as specified and testing on completion with & including provision of earth wire protected by galvanised iron 40 mm dia. light grade pipe up 7.50m and watering pipe shall be 20 mm bore medium grade with and including concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate duly reinforced with 8 mm TMT bars @100mm C/C on both sides with suitable cast iron lifting handle, GI earthing wire shall be encased in and including 50mm nominal bore GI 'light grade' tubing with all fittings from earth plate up to panel shall be provided & charcoal / salt funnel & other fittings etc. complete all as specified and as directed. Note :- (i) Unit rates includes the cost of 7.50 m GI wire & GI pipe for protection of 4mm dia GI earth wire for each earthing.
S&F in replacement of thermostat 0-85⁰C suitable for geyser of 25 ltrs capacity, complete all as specified and directed.
S&F in replacement heating element of capacity 2 KW of any type and shape suitable for existing 25 ltrs capacity geysers as per sample provided by Engr-in-Charge complete all as directed.
S&F in replacement thermostat temperature adjustable from 0-80⁰C suitable for geyser of 50 ltrs capacity complete all as directed by Engr-in-Charge
S&F in replacement heating element of capacity 2.5 KW of any type and shape suitable for existing 50 ltrs capacity geysers as per sample provided by Engr-in-Charge complete all as directed.
S&F in replacement heating element of capacity 3 KW of any type and shape suitable for Existing 50 ltrs capacity geysers as per sample complete all as directed by Engr-in-Charge
S&F in replacement flow unit (inner pipe assembly) suitable for geyser of 25 ltrs capacity of any brand/make and for vertical/Horizontal type including rubber ring /gasket complete all as directed by Engr-in-Charge
S&F in replacement metallic flexible hot water connection 600 mm long including necessary washers suitable for geysers of 25 ltr capacity complete all as specified and directed
S&F in replacement of CPRI approved electrical meter box compartmentalized design suitable for 6 No x energy meter and 6 x No Two way SPN DB, outdoor concealed in wall , weather proof fabricated out of not less than 2.0 mm thick CRCA sheet, powder coated in Siemens grey colour, double door provided at Location: Carippa and stavely Road offrs Md Accn. The enclosure shall be front openable with locking arrangement and provided with 5 mm thick bakelite sheet for mounting the energy meters and MCB DB. The enclosure shall be provided with suitable size PVC cable glands for incoming and outgoing cables / wires. The overall size of the meter box shall be as per site requirement complete with all accessories prewired twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Note:- Quoted rate shall be deemed to including the cost of disconnecting existing circuits from DB's and energy meter and same has to be re-fixed in new meter box and making good disturbed surfaces as per existing
S&F in replacement of CPRI approved electrical meter box compartmentalized design suitable for 9 No x energy meter and 9 No x Two way SPN DB, outdoor concealed in wall , weather proof fabricated out of not less than 2.0 mm thick CRCA sheet, powder coated in Siemens grey colour, double door. The enclosure shall be front openable with locking arrangement and provided with 5 mm thick bakelite sheet for mounting the energy meters and MCB DB. The enclosure shall be provided with suitable size PVC cable glands for incoming and outgoing cables/wires. The overall size of the meter box should be as per site requirement complete with all accessories prewired twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Location:-Old KT line. Note:- Quoted rate shall be deemed to including the cost of disconnecting existing circuits from DB's and energy meter and same has to be re-fixed in new meter box and making good disturbed surfaces as per existing
Demolition of existing unserviceable earth chambers and M&L for construction of new chamber including with form work and PCC 1:3:6 type C-1 as in bed, walls in PCC 1:2:4 type B-0 including iron grill and GI cover with hinge etc. complete all as per electrical plate no.3 of SSR part-I and as directed.
M&L for repairs to earth chambers by removing unserviceable earth chambers cover and S&F new GI cover with hinge complete all as directed
M & L for recharging of normal earth pits by excavating the earth at a radius of 600mm from the centre from the earth pit and at a depth of 900mm after removing the earth chambers and accessories carefully and keeping aside for re-use including adding and spreading Charcoal 10 kg & Salt 10Kg in 75mm layers each as ground level and watering, re-fixing the earth chambers and accessories after allowing the soil to settle down complete all as specified and directed by Engr-in charge
M&L for testing of existing earthing resistance with suitable digital earth tester and recording the readings obtained and making good the earthing by pouring the salt water complete all as directed by Engr-in-Charge. Note :- (i) Value of earth resistance should be less than 1 Ohms for equipments earthing and less than 5 ohms for LA & Power Supply earthings. (ii) Testing of one earthing results shall be measured as one Job.
M&L for Testing of existing earthing resistance with suitable digital earth tester and recording the readings obtained complete all as directed by Engr-in-Charge. Note:- A register will be maintained by the contractor for building / establishment / section wise (for Equipment earthing, LA, Power etc) duly signed by users. Note:- Testing of one earthing results shall be measured as one Job.
S&F in replacement of C Curve MCB SP 6-32 Amps working on 240 volts,50 Hz 10 KA, complete all as specified and as directed.
S&F in replacement of C Curve MCB DP 6-32 Amps working on 240 volts,50 Hz 10 KA, complete all as specified and as directed.
S&F in replacement of C Curve MCB SPN 40-63 Amps working on 240 volts, 50 Hz 10 KA, complete all as specified and as directed.
S&F in replacement of C Curve MCB TP 25-63 Amps working on 240 volts, 50 Hz 10 KA, complete all as specified and as directed.
S&F in replacement of C Curve MCB TPN 40-100 Amps working on 240 volts, 50 Hz 10 KA, complete all as specified and as directed.
S&F in replacement 1x20 watt, 230V surface and wall mounted emergency LED batten having backup up to 4 hours with polycarbonate housing and integrated electronic driver including connecting up with twin core twisted flexible copper conductor cable from ceiling rose all as specified . Make: Luker LTGT520 or equivalent in Havells / Philips.
Taking down ceiling fan / exhaust fan of any sweep for servicing / repairing / maintenance, opening up, identifying and replacing the defective parts, cleaning, greasing etc, re-assembling and hanging up / fixing back at its original position, connecting up and testing complete all as directed. Note:- Cost of spares such as capacitors, bearings etc will be measured and paid for separately under respective Item of BOQ as supply only.
Supply only bearing No.6201/6202/6203 or any other No matching to the existing size and suitable for ceiling fan/exhaust fan/wall mounted fan, complete all as specified and directed. Make:- SKF or equivalent
Supply only capacitor of 2.5 mfd for ceiling fan / exhaust fan, complete all as specified and directed. Make:Tibcon/Epcos/Havells
S&F in replacement of aluminum fan blades suitable for heavy duty exhaust fan of any sweep as per the sample complete all as directed by Engr-in-charge
Disconnecting electric connection and taking down carefully fan of any type and size/sweep as described below, removing the burnt winding of fan motor and M&L for rewinding of the same with super enameled copper winding wire of suitable gauge or of matching size to the existing wires including all insulating material such as insulation paper sleeve, tape, varnishing etc and reassembling, testing, transporting back to site and re-fixing to original position complete all as directed by Engineer-in-charge for following :- (a) Celling fan of size 1200 sweep.
All as per item no. 75 above but Exhaust fan of 300 mm sweep, complete all as directed by Engineer-in-charge
All as per item no. 75 above but wall mounted fan of 400 mm sweep, complete all as directed by Engineer-in-charge
Dismantling and removing rusted louvers (set of 4) and S&F new mild steel louvers duly painted gray colour synthetic enamel paint suitable for 300mm heavy duty exhaust fan along with four number mounting bracket with bolts, nuts washers etc complete all as directed by Engineer-in-charge
S&F of Plastic ventilation fan of 150mm sweep including replacing the plywood as per the site requirement, complete all as directed by Engineer-in-charge. Note:- Old Exhaust fan will be deposited in MES store yard by the contractor without any extra cost to the Department.
S&F of Plastic ventilation fan of 200mm sweep including replacing the plywood as per the site requirement, complete all as directed by Engineer-in-charge. Note:- Old Exhaust fan will be deposited in MES store yard by the contractor without any extra cost to the Department.
S&F of Plastic ventilation fan of 250mm sweep including replacing the plywood as per the site requirement, complete all as directed by Engineer-in-charge. Note:- Old Exhaust fan will be deposited in MES store yard by the contractor without any extra cost to the Department.
S&F of Plastic ventilation fan of 300mm sweep including replacing the plywood as per the site requirement, complete all as directed by Engineer-in-charge. Note:- Old Exhaust fan will be deposited in MES store yard by the contractor without any extra cost to the Department.
S&F PVC unbreakable surface boxes of size 4x4, complete all as specified and directed
S&F PVC unbreakable surface boxes of size 6x6, complete all as specified and directed
S&F PVC unbreakable surface boxes of size 4x7, complete all as specified and directed
S&F PVC unbreakable surface boxes of size 6x8, complete all as specified and directed
S&F PVC unbreakable surface boxes of size 8x10, complete all as specified and directed
Taking down carefully and re-fixing geyser of any size / make after doing the necessary repair works with necessary fasteners /clamps and making good any disturbed surface complete all as directed by Engr-in-charge
S&F in replacement of thermostat and cutout set electronic type, temperature adjustable from 0-80⁰C suitable for geyser of 25 ltrs capacity.
Disconnecting and taking down existing unserviceable geyser of 25 ltrs capacity of any make / brand, carrying over the same to civil workshop for repairing & welding etc. Opening the geyser and dismantling of all parts and taking out inner tank / container, removing dents and making it to shape including welding / brazing to the leakage portion and S&F filling of new glass wool in between inner tank and out casing of geyser. Re-assembling and carrying back to site the geyser and painting to outer casing of geyser with two coats of superior quality synthetic enameled paint after preparation of surfaces and re-fixing to its original location complete all as directed by Engr-in-charge
S&F in repairs cable PVC insulated 2 core 0.5 Sqmm with stranded copper conductor 1100V grade complete all as specified and as directed.
S&F in repairs cable PVC insulated 2 core 1 Sqmm with stranded copper conductor 1100V grade complete all as specified and as directed.
S&F in repairs cable PVC insulated, round, 3 core 2.5 Sqmm with stranded copper conductor 1100V grade as connection cord of geyser complete all as specified and as directed.
S&F in replacement of PVC insulated cable 2 core stranded copper conductor 1.5 sqmm in and including PVC conduit pipe of dia not less than 25 mm complete all as specified and directed.
S&F in replacement of PVC insulated cable 3 core stranded copper conductor 4 sqmm in and including PVC conduit pipe of dia not less than 25 mm complete all as specified and directed.
S&F in replacement of NRV valve of size 15mm dia of Brass complete all as specified and directed.
Supply & fix in replacement 15A plug top, 3 pin, 15/16 Amps, 230 V, ISI marked, suitable for geyser cord, complete all as specified and as directed
S&F in replacement of white cover plate with frame 1 or 2 module, complete all as specified and directed by Engr-in-charge.
S&F in replacement of white cover plate with frame 3 module, complete all as specified and directed by Engr-in-charge.
S&F in replacement of white cover plate with frame 4 module, complete all as specified and directed by Engr-in-charge.
S&F in replacement of white cover plate with frame 6 module, complete all as specified and directed by Engr-in-charge.
S&F in replacement of white cover plate with frame 8 module, complete all as specified and directed by Engr-in-charge.
S&F in replacement of white cover plate with frame 12 module, complete all as specified and directed by Engr-in-charge.
S& F in replacement PVC unbreakable surface boxes suitable for modular switches 1 or 2 module, complete all as specified and directed.
S& F in replacement PVC unbreakable surface boxes suitable for modular switches 3 module, complete all as specified and directed.
S& F in replacement PVC unbreakable surface boxes suitable for modular switches 4 module, complete all as specified and directed.
S& F in replacement PVC unbreakable surface boxes suitable for modular switches 6 module, complete all as specified and directed.
S& F in replacement PVC unbreakable surface boxes suitable for modular switches 8 module, complete all as specified and directed.
S& F in replacement PVC unbreakable surface boxes suitable for modular switches 12 module, complete all as specified and directed.
S&F in replacement of 3mm thick white coloured hylam sheet (bakelite) for mounting switches complete all as directed
S&F in replacement of GI pipe bracket of 25 mm dia 1.0 m long bend to shape for street light fitting made out of 25 mm dia GI light grade pipe fixed on pole using suitable FI clamp including necessary new nut, bolt and washer complete all as specified and directed
S&F in replacement LED building security light fitting 20 W, IP-65 protection made up of die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening separate driver compartment complete all as specified and directed by Engr-in-charge. Make- Luker LSTE-20 / Havells ENDURACITYLITEPLAT PLUSSL20WLED757SASYBOPC / Wipro LR02-331-XXX-57-XX
S&F in replacement of 1x10 watt, 230V surface and wall mounted LED batten suitable for mirror light with polycarbonate housing and integrated electronic driver including connecting up with twin core twisted flexible copper conductor cable from ceiling rose all as specified . Make: Luker LT510P / Wipro / Havells
S&F in replacement of 18/20 watt, 230V surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper conductor cable from ceiling rose complete all as specified and directed. Make- Luker LT5M20 / Havells ENDURALINEARNEOBS20WLED865SPCWH / Bajaj BCLAB 20W WH LED P
S&F in replacement of recess type LED ceiling lights 15 W LED with ceiling cut out of Ø 170 mm, 6000K recess mounted down lighter with separate replaceable electronic driver including connecting with twin core wire, including cutting the existing false ceiling dia to the required size and also matching to the adjacent false ceiling surfaces carefully complete all as specified and directed. Make:- Luker /Havells / Crompton
Supply & fix in replacement of LED recess mounting down lighter with ceiling cut out of 125 mm dia of wattage 9 watt 6500K with LED backlit round down lighter made of PDC AL with high efficient LEDs & glare free opal diffuser, IP20 including taking down existing, complete all as specified and directed Make:- Luker/Havells/Crompton
Supply & fix in replacement of LED fixture 30 watt surface mounted ceiling light 6500K with diffuser to give glare free light of size 300x300x35 mm, aluminium housing with compatible driver complete all as specified & directed. Make:- Luker/Havells/Crompton
S&F in replacement surface mounted 2' x 2' LED Panel lights 40 Watts, LED 5700K, 240Volts and glare free symmetrical illumination suitable for Armstrong/Grid ceiling, Environmental friendly, new generation, energy saving, high power LED as a light source with clear diffuser and separate replaceable electronic driver with and including Light, its driver and connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully all as specified and directed. Make: Luker Cat Part: LNPSRS40/ Havells Pluto/ Philips
S&F in replacement Decorative wall mounting brushed nickel fixture suitable for B22 base bulb including 01x7 W LED bulb (warm white) and connecting up with twin core twisted flexible copper conductor cable from ceiling rose complete all as specified and directed. Make:- HALONIX Cat part HLWB-01-B22 or equivalent CAT PART in Philips/Jaquar
S&F in replacement 1x10 watt, 230V surface mounted LED down light with white powder coated polycarbonate housing and pressure die-cast heat sink having high efficiency, including connecting up with twin core twisted flexible copper conductor cable from ceiling rose complete all as specified and directed. Make - Luker Cat part no. LBKRDSL10 /Havells INTEGRANEOSURFA CEDLS10WLED857S or equivalent cat part in Philips
S&F in replacement of electronic driver suitable for 25/30 watts LED building security light fittings as per existing make complete all as specified and directed by Engr-in-charge
S&F in replacement surface mounted 2' x 2' LED Panel lights 40 Watts, LED 5700K, 240Volts and glare free symmetrical illumination suitable for Armstrong/Grid ceiling, Environmental friendly, new generation, energy saving, high power LED as a light source with clear diffuser and separate replaceable electronic driver with and including Light, its driver and connecting with twin core wire and also matching to the adjacent ceiling surfaces carefully all as specified and directed. Make: Luker Cat Part: LPS40/ Havells Pluto/ Philips
M&L for painting of ceiling fan of any sweep with two coats of synthetic enamel paint by rubbing / removing the old paint carefully without any damage to the fan or fan blades etc complete all as directed by Engineer-in-charge.
M&L for painting of exhaust fan of any sweep with two coats of synthetic enamel paint by rubbing / removing the old paint carefully without any damage to the fan or fan blades etc complete all as directed by Engineer-in-charge.
S&F in replacement recess type LED COB lights 12 Watts including with ceiling cut out of Ø 92 mm Environmental friendly, energy saving, recess mounted down lighter with separate replaceable electronic driver including connecting with twin core wire, including cutting the existing false ceiling dia to the required size and also matching to the adjacent false ceiling surfaces carefully complete all as specified and directed. Make: Luker cat part no. LCOB12N or equivalent in Havells / Philips
S&F in replacement of electronic driver for 20 watts COB lights as per the existing make complete all as specified and directed by Engr-in-charge
S&F in replacement of 200 watt integral SMD LED Highway luminaries with aluminium reflector light fitting including with inbuilt electronic drivers, necessary hanging arrangements as per site requirement including taking down the existing one complete all as specified and directed by Engr-in-Charge. Make:- Luker Cat part no. LOHY200 / Havells BAYBRITESAUCERHBP200WLED757WBTOLTG /Philips Note: Ladders /Cranes required for dismantling /fixing of light fittings at roof shall be arranged by the contractor and the cost of same shall be deemed to be included in unit quoted rates.
M/S Eagle Electricals And Rewinding Works (BID ID -3279474)
metro electrical services (BID ID -3279068)
shiva traders (BID ID -3279735)
PROLINK COMPUTERS (BID ID -3278609)
SBS Enterprises (BID ID -3279814)
RELIABLE ENTERPRISES (BID ID -3277921)
Crown Chemicals (BID ID -3280002)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .