Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.0 LAccepted-AOC NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | 1 | Accepted-AOC L1 | |
| 2 | 2₹32.5 L+₹4.1 L (14.6%)Rejected-Finance | 2 | Rejected-Finance L2 | |
| 3 | 3₹37.7 L+₹9.4 L (33.2%)Rejected-Finance | 3 | Rejected-Finance L3 | |
| 4 | 4₹38.5 L+₹10.2 L (36.1%)Rejected-Finance CHENNAI | CHENNAI | TAMIL NADU | 600001 | 4 | Rejected-Finance L4 |
Tender Value
₹33.8 L
EMD Value
₹68,000
Closing Date
21 Nov 2023, 6:00 pmClosed
AGM (E-E)
Asst. General Manager (Engg-Elect), Airports Authority of India, Southern Region, Operational Offices, Chennai Airport, Chennai 600 016
Construction of Perimeter wall around FTOs and Frisking Rooms at Salem Airport. SH Electrical Works
2023_AAI_172283_1
AAI/RHQ-SR/AGM(E-E)/SLM/2023/
Open Tender
Electrical Works
Item Rate
162 days
Salem Airport
Please refer Tender documents.
18 documents required · 18 mandatory
₹1,180
₹68,000
5 Jan 2024
31 Oct 2023
23 Nov 2023
31 Oct 2023
21 Nov 2023
31 Oct 2023
31 Oct 2023 - 3 Nov 2023
SH:I Supply Items
Supply of 30W linear surface mounted LED luminaire IP 66 240V with pressure diecast aluminium alloy housing, PDC aluminium centre cover, UV stablized injection moulded PC diffuser cover, Corrosion resistance powder coated using nano technology, High efficiency isolated driver with necessary safety protections & inbuilt surge protection of 4KV, life of 50,000 burning hrs as per L70 standard, system efficacy >100LPW, CRI>80, THD<5%, comes with additional 6KV external surge protector with 5 years warranty. ( LT make: Parker V2 surface or Equivalent)
Supply of 36W 2 feet X 2 feet surface mounted LED luminaire IP 20 240V with pressure diecast aluminium alloy housing, PDC aluminium centre cover, UV stablized injection moulded clustered PC diffuser cover, Corrosion resistance powder coated using nano technology, High efficiency inbuilt isolated driver with necessary safety protections & inbuilt surge protection of 6KV, life of 50,000 burning hrs as per L70 standard, system efficacy >120LPW, CRI>80, 5700K CCT and THD<5% complete as required with 5 years warranty. ( LT make: Fulllit CR Slim V2 surface PRFV203640NDWEPC01 or Equivalent)
Supply of 36W 2 feet X 2 feet recessed mounted LED luminaire IP 20 240V with pressure diecast aluminium alloy housing, PDC aluminium centre cover, UV stablized injection moulded clustered PC diffuser cover, Corrosion resistance powder coated using nano technology, High efficiency inbuilt isolated driver with necessary safety protections & inbuilt suege protection of 6KV, life of 50,000 burning hrs as per L70 standard, system efficacy >120LPW, CRI>80, 5700K CCT and THD<5% complete as required with 5 years warranty. ( LT make: Fulllit CR Slim V2 surface PRFV203657NDWEP or Equivalent)
Supply of 45W LED streetlight luminaire with color temperature (5700K ± 355K), made of a single piece Pressure die cast aluminum (PDC) housing & has separate driver and optical compartment for Thermal isolation. Powder coated by Corrosion resistant Nano coating technology. The fixture is provided with a injection moulded UV stabilized Polycarbonate cluster lens cover for optimum light spread. Integral encapsulated high efficiency electronic driver having an Aluminum extrusion construction with rated voltage of 140-270V, power factor > 0.95, THD < 5%, IP66 protection, Inbuilt surge protection of 5 KV, has mis wiring, Over voltage, Short circuit, Reverse Polarity protection, Input over Voltage cut-off at 320V with Auto Recovery feature. Also upgraded with integrated IP67 protected SPD of 10KV/5KA surge protection & Line-Line 440VAC Withstand capacity up to 4Hrs. Driver is placed in a separate hingeable compartment which is replaceable in the field condition with minimum Tools. The luminaire lumen output > 135 LPW & system efficacy of >4700 Lm , CRI of 70 .Suitable for pole Dia of 50 -60 mm. BIS Certification for Luminaires & Drivers with 5 years warranty. (LT make: Adornis Min or equivalent)
Supply of 20W - 24W solar LED street light ALL IN ONE with lumen output of minimum 3500 and system efficiancy of >175lm/W, efficient monocrystalline solar panel, new age lithium ferro phosphate battery, uniquely designed aluminum housing for better heat dissipation & strategically placed perforations allowing natural air passive cirulation within & into the housing for improved thermal management of internal components, including mounting bracket, IP 65 with 5 years warranty.
Supply of elevated WHITE coloured out put LED lamp fixture with bird spike protection along with MS powder coated base mount flange for landing H single phase 230V, 6W, IP66,wire free bus type LED cluster, LM-6 Aluminium alloy with Pure Polyster powder coat, Lens made of Polycarbonate U.V stabilized optical grade suitable for outdoor/sunlight exposure, PCB's of Glass epoxy FR-4 grade with UVLO-94 tested type,Fixture with Individual solid-state and inbuilt 5 kV surge protection, cable connector shall be provided along with fixture, designed in accordance with ICAO Aerodrome standards-aerodrome design & operators manual.(Make: RAYDYNAMICS, Model:LTL-5W-UI or any Make meeting requirements).
Supply of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required with 5 years warranty.
Supply of 400 mm sweep 5 Blade silent operation pedastal fan of 1350 RPM and Air delivery of 85 CMM. (Make: Crompton, Model : SilentPro Pentaflo or Similar product from AAI list of preferred makes)
Supply of 450 mm dia single phase 1400 RPM heavy duty Exhaust fan (ISI marked) with louver including all accessories etc as required.
Supply of wall mountable portable Rechargable Emergency LED lamps 9 to 12 watts with minimum 6 hours backup battery, operating supply of 230V AC, auto on&off etc as required.
Supply of 150W LED flood light having PDC Alluminium body, corrossion resistant with nano technology powder coating, inbuilt 6kV surge protection, Short circuit, over voltage and thermal protection, additional 10kV Surge protection device to be provided externally, suitable to operate on 230V AC, 1-Phase supply, IP 66, IK 08 rating,THD < 5%, pf > 0.95, with lumen output of >110, with 5 Year Warrenty.
SH:II Internal & External Electrification :
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed steel conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for twin control light point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required.
Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in recessed steel conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing following size/modules, Gl box along with modular base & cover plate for modular switches in recess etc., as required.
2 Module
3 Module
6 Module
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 5/15 A socket outlet
Telephone Socket
Supplying and fixing following way, horizontal type three pole and neutral, IP43, sheet steel, MCB distribution board, 415 V, on recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc., as required.
6 way (8 + 18), Double door
Supplying and fixing Cable End Box (Loose Wire Box) suitable for 8 Way Double door, triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on recess, complete with testing and commissioning etc.as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per drawing attached in technical specification for circular box type fan clamp.
Supplying and fixing 5 A to 32 A rating, 240 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc., as required
Single pole
Supplying and fixing of 63 A rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc., as required.
Supplying and fixing of 63 A rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 300 mA in the existing MCB DB complete with connections, testing and commissioning etc., as required.
Installation, testing and commissioning of pre-wired LED fittings of all types, complete with all accessories and tube etc., directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc., as required
Installation, testing & commisioning of 45W LED street light fixtures on wall by providing outdoor type IP 66 polycarbonate box of size 155 x 210 x 92 having 6 Amps MCB, 16 Sqmm 4 pole Connector terminal , din bar, supply and laying of 3C x 1.5 Sqmm copper cable between fixture and MCB and earthing connection, including termination for 4C x 16 Sq.mm and suitable GI arm bracket of 1.5 Mtr length and minimum thickness of 3 mm etc., complete as required
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan with louver in the existing opening, including making good the damage, connection, testing, commissioning with 1.5 sqmm flexible FRLS cable etc., as required. Upto 450mm dia
SITC of 7 Mtrs height Octagonal Hot Dip GI street light pole upto 1 mtr long single arm bracket suitable for mounting single street light luminarie complete with base plate, J foundation bolts with template, washer nuts, anchor plates, earthing stud including providing suitable RCC (1:3:6) pole foundation as per standards/OEM specification, suitable dia heavy duty PVC pipe in foundation for cable entry and exit etc., complete as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/ METAL / HDPE pipe as required.
Upto 35 Sq.mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Above 185 sq. mm and upto 400 sq. mm
Supplying and laying of "B" Class G.I pipe of following dia, i/c excavation of bituminous/ concrete road/ pavement, excavation of Soil to maximum depth of 1.2 Mtrs from ground refilling the Soil and with CC of ratio 1:3:6 on top for 0.15 Mtrs after laying Pipe and plastering, making good the same etc., as required.
Supplying and laying of following size OD HDPE Pipe of PE 80 PN 6 ISI Marked along with all accessories conforming to IS 4984:2016 complete with fitting and cutting, jointing etc., direct in ground (0.75 Mtr below the ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., as required.
Supplying and laying of following size OD HDPE Pipe of PE 80 PN 6 ISI Marked along with all accessories conforming to IS 4984:2016 complete with fitting and cutting, jointing etc., direct on wall/roof etc., as required.
40 mm (clamped with 3 mm thick saddle)
110 mm (clamped with 3 mm thick saddle)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4C x 16 Sq.mm
4C x 25 Sq.mm
3.5C x 150 Sq.mm
3.5C x 240 Sq.mm
SH:III SITC of Panels
Fabrication and Supply of MV Switch Board Panel of Outdoor type (Doouble door with hinged type outdoor) tested design as per IEC 61439-1 & 2 suitable for 415 V, 3 Phase, 4 wire 50 Hz AC supply,made out of 3mm thick CRCA sheet steel for outer Shell (width not less than 450 mm) with canopy and 2mm thick CRCA sheet steel for inner partition, 3 mm thick for gland plates, dust tight, vermin proof, totally enclosed, cubicle type, floor mounting, free standing, extensible on both sides, painting with 7 tank process for powder coating in approved shade and also includes provision of necessary supporting arrangement with MS "C" channel bottom base channel of MS section not less than 100 mm x50 mm x 5 mm thick, entire panel shall have a common copper earth bar of size 25mm x 5 mm at the rear with 2 nos earth stud,control wiring with 2.5 Sq.mm. FRLS PVC insulated copper conductor cable, cable alleys, cable gland plates in two half and suitable for outdoor operation, complete with all accessories, interconnection, earthing, alignment with the bus ducts etc., as required comprising of the following:
I) Incomer Details: A) Two Nos. of 250 A, 50 KA, 4P MCCBs as per latest IEC with Thermal Magnetic Based Releases for OC/SC Protection as INCOMERS with extended ROM for mechanical ON/OFF, cast resin type CT operated Digital MultifunctionMeter [EM 6400 of Conzerve/Equivalent], ON/OFF/TRIP Indication Lamps and Phase Indication Lamps etc., as required. B) One No. of 250 A, 50KA. 4P MCCB as per latest IEC with Thermal Magnetic Based Releases for OC/SC Protection as a Buscoupler with extended ROM for mechanical ON/OFF. Providing Mechanical and Electrical Interlocking Facility for 2 incomers and Buscoupler including necessary contactor arrangements etc., complete as required.
II) Outgoing Details: C) Two Nos. of 125 A, 25 KA, 4P MCCBs as per latest IEC with Thermal Magnetic Based Releases for OC/SC Protection as Outgoings with extended ROM for mechanical ON/OFF, cast resin type CT operated Digital MultifunctionMeter [EM 6400 of Conzerve/Equivalent], ON/OFF/TRIP Indication Lamps and Phase Indication Lamps, as required. D) Six Nos. of 100 A, 25 KA, 4P MCCBs as per latest IEC with Thermal Magnetic Based Releases for OC/SC Protection as Outgoings with extended ROM for mechanical ON/OFF, cast resin type CT operated Digital MultifunctionMeter [EM 6400 of Conzerve/Equivalent], ON/OFF/TRIP Indication Lamps and Phase Indication Lamps, as required. E) Two Nos. of Three Phase Surge Protection Device (SPD)for both direct and indirect lightning having 100KA 10/350 micro seconds neutral to earth, 50 KA 10/350 micro sec line to neutral respectively, with limiting voltage less than 1.5 KV connected on the mains power entry point at the incomers & of modular type. F) One Set of 400 Amps Al. Bus Bars with at Par Neutral BUS BARS as required. G) All accessories such as fuses, auxillary contactors, auxillary switches, etc. complete as required.
Installation, Testing and Commissioning of MV Switch Board Outdoor Type panel mentioned in Item No. from 3.01 to 3.03 including excavation for foundation, providing RCC foundation up to 45 cm height above GL, fixing of panel over the RCC foundation with Fastner and earthing connections etc. complete as required.
Supply of Loop-in Loop-out Box Outdoor type (Doouble door with hinged type outdoor and key lock) made out of 3mm thick CRCA sheet steel for outer Shell (width not less than 450 mm) with canopy and 2mm thick CRCA sheet steel for inner partition, 3 mm thick for gland plates, dust tight, vermin proof, totally enclosed, cubicle type, floor mounting, free standing, extensible on both sides, painting with 7 tank process for powder coating in approved shade and also includes provision of necessary supporting arrangement with MS "C" channel with 125A copper busbar for three Phase & One Neutral, Gland & connection Provision for one incomer (3.5 C x 150 sq mm) and 5 outgoing , earth connection and suitable for Three Phase AC supply etc complete as required.
Installation of Outdoor type Loop-ln Loop-Out Box mentioned in item no.3.05 including excavation for RCC foundation of 0.8(L)x0.75(W)xo.5(D) all dimensions in metre upto ground level, Fixing of Junction Box over the RCC foundation with Channel upto an height of 400mm with necessary fixing arrangements etc. including cable terminations complete as required.
Supply and fixing of 125A, 4 pole, 3 phase, 415V On Load manual changeover confined to IEC: 60947-3 with powder coated sheet steel enclosure with ROM type extendable handle, suitable arrangement shall be made for wall mounting of the enclosure etc complete as required.
Supplying and fixing of Loop-in Loop-out Box made of Transparent Polycarbonate with 125A copper busbar for three Phase & Neutral, Gland & connection Provision for one incomer and 5 outgoing, earth connection and suitable for three Phase AC supply etc complete as required. (Make: Hensel or equivalent)
SH:IV SITC of Electrical Items for UPS
Supply of 3.5C x 95 Sq.mm size XLPE insulated PVC sheathed aluminium conductor armoured power cable of 1.1KV grade confirming to IS 7098 (PART-I) with upto date amendments as required.
Laying of one number XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Above 95 sq. mm and upto 185 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for 3.5C x 95 Sq.mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc., as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required
Providing,fixing and laying of following sizes Unplasticized Polyvinyl Chloride (UPVC) pipes at 0.5 Mtr below direct in ground, including all UPVC plain & brass threaded fittings this includes jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete etc., as required.
32mm nominal dia
25mm nominal dia
DEEPAKELECTRICALS
CHENNAI ENGINEERING SERVICES
vk sam engineering
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .