Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹5.0 Cr
EMD Value
₹10.0 L
Closing Date
26 Nov 2025, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
EXECUTIVE ENGINEER Construction Division PWD B and R Malerkotla
Construction of Two Additional Court Room in the Litigant Block of Judicial Court Complex at Malerkotla Distt.Malerkotla (Punjab)
2025_CEPW_153159_1
Bid Notice No.20 dt.29.10.2025
Open Tender
Civil Works - Buildings
Percentage
270 days
Malerkotla
Please refer Tender documents.
18 documents required · 18 mandatory
₹30,000
₹10.0 L
26 Nov 2025
5 Nov 2025
26 Nov 2025
5 Nov 2025
26 Nov 2025
5 Nov 2025
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.
Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
TOTAL AMOUNT in Rs. P
Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the same shall be deducted )
Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC)
Extra rate for enhancement in pumping power, addition of pipe length, scaffolding for handling the pipe arrangement for pumping of concrete in subsequent storey above the below storey up to height of 4 meters or part there of up to the roof top level of that storey
Centering and shuttering for columns (Square or rectangular or poly gonal in plain)
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Qty Same as per M25 First Floor
Extra Rate For Second Floor
Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels.
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Centring and shuttering for stair cases with sloping with soffits including risers and stringers.
Extra Rate For First Floor
Extra Rate For Second Floor
Qty Same as per M25 Second Floor
Extra Rate For First Floor
Extra Rate For Second Floor
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Qty Same as per M25 Third Floor
Extra Rate For First Floor
Extra Rate For Second Floor
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Centering and shuttering for columns (circular or curved in plain)
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure
Extra Rate For Second Floor
Providing and fixing chicken mesh for brick work and RCC junction of galvanized low carbon wire, annealed wire of diametre 0.6 to 2.0mm distance between the faces of the hexagon 13 to 50mm complete in all respect.
12.5 mm thick cement plaster 1:5
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
20mm thick cement plaster 1:5 in two coat work
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
12.5 mm thick cement plaster 1:4
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
20mm thick cement plaster 1:4 in two coat work
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Forming groove of uniform size from 12xl2mm and upto 25xl5mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-Charge.
Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc.
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend
Centering and shuttering for arches of varandah, door and windows openings.
Extra rate for using steel from Integrated plant marked as primary Producer steel.
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp U-PVC pipes (working pressure 4kgf. / sqcm) pipe 110 mm dia.
Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on- edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3.
Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers incluidng ramming, watering and consolidated all lead . CSR 6.8 C(i)
Earth filling :--Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100mm fine sand filling using mechanical mixer for mixing of material.
Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material
Extra Rate For First Floor
Extra Rate For Second Floor
Extra Rate For Third Floor
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm
Extra Rate For Second Floor
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm.
Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Extra Rate For First Floor
Extra Rate For Second Floor
Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness andcolouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects.respects.
Kotah stone tile 20mm thick in skirting, riser of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 Cement and 3 Sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing
Extra Rate For First Floor
Extra Rate For Second Floor
Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Udaipur Green Marble Tiles of thickness 18mm to 20mm Slabs sizes above 0.50 sqm
Extra Rate For First Floor
Extra Rate For Second Floor
Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.
Extra Rate For First Floor
Extra Rate For Second Floor
Extra labour for projected nosing of stair case of any shape and design
Providing and Laying Out Door Precast Designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3(1 ordinary cement :3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge.
Extra Rate For Second Floor
Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability)
Extra Rate For First Floor
Extra Rate For Second Floor
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.
Extra Rate for First Floor
Extra Rate for Second Floor
Extra Rate for Third Floor
Providing and fixing tiled false ceiling at height upto 4 mtr of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece..) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge.
Doors and windows frame of size 118mm x 60mm with 40 mm wide single rebate weighing 3.43 kg per meter.
Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect. 5.0mm thick Plate glass (INDIAN)
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects.
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) :
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item)
Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work.
Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Providing and fixing of 30mm thick factory made Polyvinyl Chloride (PVC) door shutter (without chowkhat) made of styles and rails of a UPVC Plug profile section of size 30mm x 60mm and wall thickness 2mm ±0.2mm with inbuilt decorative molding edging on one side. Th
e styles and rails with plastic brackets of size 75x220mm meter and welded at the corners. The- stiles of the shutter reinforced by inserting galvanized MS tube of size 25x20mm and 1mm ± 0.1mm wall thickness. The lock rail made up of ‘H’ section, a UPVC Plug profile section of size 30mm x 100mm and 2mm±0.2mm wall thickness welded to the shutter style with a UPVC Plug profile section single panel of size not less than 620mm, having overall thickness of 20 mm and 1 mm±0.1 mm wall thickness with 20 mm panel beading of suitable size /Glass(4mm thick plain glass)/louver section, louver frame of suitable size, as per manufactures specification and direction of Engineering- charge. (For WC and bathroom door Shutter)
Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge.
Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : IS 2202-1 (1999). Decorative with elm or gurjan facing on one side and teak facing on the other side edges lipped with teak with laminated core 35mm thick
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm
Providing and fixing stair case railing made out of M.S. Square bars 20x20m as vertical cost 0.70 metre high fixed with M.S. Base plate of 40mx40mmx6mm and flat iron 40mmx6mm as hand rail complete in all respects.
UPVC 110 mm Coupling /Sockets
Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating
Providing & fixing 16 guage stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainles steel pipe, Balusters of 40mm dia stainless steel pipe complete in all respects. Side Ramp (Railing on Enterance Ramp Design as per guidelines issued for persons with disability)
Extra Rate for First Floor
Extra Rate for Second Floor
Extra Rate for Third Floor
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Extra Rate for First Floor
Extra Rate for Second Floor
Extra Rate for Third Floor
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Extra Rate for First Floor
Extra Rate for Second Floor
Extra Rate for Third Floor
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)
Extra Rate for First Floor
Extra Rate for Second Floor
Extra Rate for Third Floor
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Construction of Plinth protection complete as per drawing.
Earth work in exavation in foundations, trenches, etc. in all kinds of soil where pick jumper work is not involved and not exeeding 2.0 Mtr. depth and subsequent filling around masonary in 15 cm layers with compaction including disposal of all surplus soil as directed within a lead of 30 Mtr. complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer In-Charge.
Cement Concrete 1:8:16 with 40mm guage stone aggregate using mechanical mixer.
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material
Conglomerate floor 40mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material).
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet
Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications.
Providing and fixing covering 200mm wide Aluminium Sheet 14 Gauge with gatties and screw on vertical expansion joints one side fixed and one side fixed with slotted holes to allow movement complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge.
Modification of Ground Floor
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
Cement Concrete 1:4:8 with stone ballast of size. mixing by mechanical means using concrete mixer volumetric type CSR 10.11 (b) (ii)
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. 11.6
115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement sand mortar in super structure.
Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Udaipur Green Marble Tiles of thickness 18mm to 20mm Slabs sizes above 0.50 sqm
12.5mm thick cement plaster 1:5. (15.10)
20 mm thick cement plaster 1:5 in two coats work. (15.21)
Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) size 600 x 600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout ) with Cement base grout and matching pigments etc., complete, including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size Size 600X600 mm.
Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.
Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects.
Supplying and fixing of Japani sheet framesv(Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. Doors and windows frame of size 118mm x 60mm with 40 mm wide single rebate weighing 3.43 kg per meter.
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer- in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items) 30mm thick
Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect. Glazing area above 0.09 sqm 5.0mm thick Plate glass (INDIAN)
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
Providing & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are
to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge.
Providing & fixing 30mm thick Factory Made solid Panel PVC Door shutter (Pannel thickness 5mm) Consisting of frame made out of M.S tubes of 19 guage thickness and size of 19mm x 19mm for styles & 15mm x 15mm for top & bottom rails. M.S frame shall have a coat of steel primers of approved make & manufacture. M.S frame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming styles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the styles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc. complete as per manufacturer's specification, conforming to test criteria specified in IS:4020- 1998,Drawings and to the entire
Providing & fixing 16 guage stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainles steel pipe, Balusters of 40mm dia stainless steel pipe complete in all respects. Side Ramp (Railing on Enterance Ramp Design as per guidelines issued for persons with disability)
Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.
Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)
Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick
V shaped brick jali in 22.86cm thick walls laid in cement sand mortar 1:6 finished with 12.5mm thick cement sand plaster 1:6 including making straight edges with plaster
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm
Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti ncluding finishing the surface to required finish complete.
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
DISMANTLING & Credit
Stripping and stacking slate or tiles of a roof.
Earth work excavation in ordinary soil, exclusive of compensation of earth:-Earth work undressed with a combined lead upto 15 metres including breaking of clods.
Dismantling concrete Reinforced cement concrete
Removing doors and windows
Doors
Windows
Dismantling cement conglomerate floors 25mm to 50mm thick including concrete base.
Dismantling brick work tile, masonry or tile lining In cement
Add for roof trusses of iron or wood, (rafters, purling etc.) in case of item Nos. 8.10 and 8.11.
Disposal of Malba ouitside the premises including loading and unloading as desired by Engineer in charge.
Dismantling steel work in built up sections in angles,tees, flats and channels including all gusset plates,bolts, nuts, cutting rivets, welding etc. includingdismembering and stacking within 50 metres lead.
Credit of Material to be received from dismentling
Tile from dismenling of tile terracing
Bricks from dismenling of Brick works
Brick/Tile bats
PPGL Sheet
Credit of Steel & Iron
Construction of Outer Development & Parking
Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical
Construction of granular sub-base by providing material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MORD technical specifications (CSR 24.7)
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Providing, laying, spreading and compacting stone aggregates of Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant , to site of work , laying in uniform layers with paver in sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per technical clause 406 of MORT&H specification. CSR 24.13
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge IS Code : 15658(2006)
Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours.
Precast Cement Concrete Kerb Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications
Providing and fixing infromatory sign board size 5'-0" x 4'-0" with square pipe 50mm x 50mm, ACP sheet 3mm thick 304 grade steel letter Complete as per specifications and as desired by engineer-in-charge. .
Providing and fixing infromatory sign board size 6'-0" x 2'-6" with square pipe 50mm x 50mm, ACP sheet 3mm thick 304 grade steel letter Complete as per specifications and as desired by engineer-in-charge.
C.P. brass toilet roll holder with flap
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.
Providing and fixing infromatory sign board size 3'-0" x 2'-0" with square pipe 50mm x 50mm, ACP sheet 3mm thick 304 grade steel letter Complete as per specifications and as desired by engineer-in-charge.
Providing Internal Electrical Installations:
Providing and fixing infromatory sign board size 18'-0" x 2'-6" with square pipe 75mm x 50mm, double legged 2.1mtr high made of 100mm x 100mm MS Pipe duly painted , ACP sheet 3mm thick 304 grade steel letter Complete as per specifications and as desired by engineer-in-charge.
Wiring light point
Wiring 3 pin 6 Amp. wall socket point
Wiring 3 Pin 6 Amp. Plug control comprising wall socket point
Wiring 3 pin 16/20 amp. power plug control point
Wiring light point with double control switches.
Providing and fixing Name Plate size 1'-6" x 1'-0" with 3mm thick ACP Sheet, writing matter with retroreflective tape Complete as per specifications and as desired by engineer-in-charge.
Size 0.6 m. x 0.6 m.
Providing and fixing Name Plate size 2'-0" x 1'-6" with 3mm thick ACP Sheet, writing matter with retroreflective tape Complete as per specifications and as desired by engineer-in-charge.
Wiring fan point with sheet metal fan box
Aluminium thimble cable Core size 4 - 6sq.mm
Wiring call-bell point
Aluminium thimble cable Core size 10 -16sq.mm
LED'S FIXTURES & FANS:
RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erecte
Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
Supply and erection of BEE 3-Star rating AC Ceiling Fan 1200mm (48") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 210 CMM (approx.). The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos. of speeds. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site.
Supply and erection of Heavy duty Exhaust Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
d at switchboard height.
Ceiling Rose (Flush Piano type)
Call Bell 220/230 volts AC Ding Dong
PVC to G.I connection
Overall size 25sq.mm (Un-sheathed)
Heavy gauge PVC conduit pipe 20mm dia. (ISI marked) Flushed
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
Heavy gauge PVC conduit pipe 32mm dia. (ISI marke
Dismantling interlocking pavers and relaying in same condition complete in all aspects.
RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories).
Overall size 1sq.mm (Un-sheathed)
Overall size 1.5sq.mm (Un-sheathed)
Overall size 2.5sq.mm (Un-sheathed)
Overall size 4sq.mm (Un-sheathed)
Overall size 6sq.mm (Un-sheathed)
Overall size 10sq.mm (Un-sheathed)
Overall size 16sq.mm (Un-sheathed)
P/F C.I assembly 3" to connect PVC pipe with C.I specials
d) Flushed
Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed
Supply and erection of Slim Recessed mounted, Round downlighter 18 watt with Pressure die cast aluminium housing & polycarbonate diffuser with surge protection 10KV and efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 %, housing & driver shall be of same brand, supported with LM 79 reports not more than 2 years old from NABL /UL accredited laboratory complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. The certification and specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
Supply and erection of Recessed mounted 36watt LED panel (including LED driver) with CRCA sheet having efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
SUSPENSION RODS FOR CEILING FANS:
HEAVY GUAGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan.
CONDUIT PIPE & COPPER WIRES:
MCB Four Pole 50, 63amp. (10kA, Curve-C)
SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES: Supply and erection of M.S. Channel bracket made from 100mm x 50mm of length 600mm and height 600mm with M.S. angle iron 40mm x 40mm x 5mm for installing metal halide flood light fitting on it. Bracket should be fixed/ welded with the existing pipe of cover shed. The bracket should be painted with one coat of primer and two coats of approved paint. (For Flood Lights on Parapet wall)
SUB DISTRIBUTION SYSTEM:
TP&N Vertical Double Door Distribution Board 4 way each.
TP&N Vertical Double Door Distribution Board 8 way each.
Hand boring Horizontly for crossing of pipe under road or any other obstacle by using Auger/Bocki method.Including excavation, stringing and jointing of pipe upto 160mm complete
Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:-Cable End Box for TPN Vertical 4/8/12Way
INDOOR LT PANELS:
SUB LT PANEL (FOR Litigant Block): (Emergency Supply): LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 8Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1575 x 1700 x 400mm)
SUB LT PANEL (FOR Litigant Block): (Normal Supply):LT Panel enclosure having space for 1No. Incomer MCCB 160Amp. and 4Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1825 x 900 x 300mm)
MCB Single Pole 6-32amp. (10kA, Curve-C)
MCB Four Pole 40amp. (10kA, Curve-C)
Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) BClass, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete.
ON LOAD CHANGEOVER SWITCH (With Sheet Enclosure): Supply and erection of On Load Change over Switch with advance neutral UNIT in sheet enclosure on the existing surface. (Confirms to IS 13947 (Part-3). complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:- On Load Change Over Switch Four Pole 250amp., 415volts (With Sheet Enclosure)
MCCB Four Pole 40/63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MCCB Four Pole 160amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MCCB Four Pole 250amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MCCB Four Pole 400amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting
MCCB Four Pole 630amp., 415volts, ≥36kA Microprocessor Based Adjustable Thermal and Magnetic Setting
Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length)
EARTHING SYSTEM (INDOOR):
Earthing with 25mm x 3mm Copper Tape (upto 14Metre in Length)
Additional Length 20mm x 3mm thick Copper Tape .
Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed)
Overall size 16sq.mm (4 Core) Un-armoured (Loose)
Additional Length 25mm x 3mm thick Copper Tap
Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.)
Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.)
Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:-
INDOOR LT CABLES, CABLE TRAY, DWC PIPE , BRASS GLANDS & THIMBLES:
Overall size 6sq.mm (2Core) Un-armoured (Loose)
Brass Gland for Aluminium cable 2/3/4 Core size 6sq.mm
Brass Gland for Aluminium cable 2/3/4 Core size 16sq.mm
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-
Overall size 70sq.mm (3½ Core) Un-armoured (Loose)
Overall size 150sq.mm (3½ Core) Un-armoured (Loose)
OCCUPANCY SENSORS:
Supply and erection of Ceiling mounted Occupancy based PIR sensor (360° detection angle motion detector) with installation height 3mts, 8.5 Amps resistive load, Detection dia 8M, time delay - 5s to 59 mins , Light level threshold - 5 to 1275 Lux, IP - 20, Sensitivity Adjustment, Walk LED test, with additional options like walkthrough, daylight set point, vacancy complete in all respect as approved and desired by the Engineer in-charges at site.
SAFETY EQUIPMENTS:
Double Walled Corrugated HDPE Pipe 160/ 136mm (Outer/ Inner dia.)
Brass Gland for Aluminium cable 3/3½/4 Core size 70sq.mm
Brass Gland for Aluminium cable 2/3/3½/4 Core size 150sq.mm
Aluminium thimble cable Core size 70sq.mm
Aluminium thimble cable Core size 150sq.mm
Providing 1No. 13 Passenger Lift 3 stop & Extension of 1 Nos. existing Otis Make Lift of 13 Passengers Machine Room Less From 1 Floors to 2 Floors.
n 600mm long at 900mm above floor level (Side LH,Side RH & Rear) Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level Std. Govt. features.
Other Features: 1. Battery operated emergency light with rechargeable battery 2. Battery operated emergency alarm with rechargeable battery 3. Adjustable Guide shoes 4. Micro movement LED based buttons 5. Door Open and Close buttons 6. Emergency Intercom provided inside the elevator 7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication 9. Steel items, door frames sill angle's, fascia plates, spring buffers 10. Automatic phase reversal device and Phase Failure protection 11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13. Manual break lever 14. Additional car gate lock 15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance / exit is either Open or Close 19. Car Operating Panel 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel 21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance car call protection 26. Door Nudging 27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure. 28. The use of visually and accoustically reflective wall surace should be minimized within the lift car as visual reflections can cause discomfort and affect the visual acuity of people with impairements. 29. The floor of lift car should be slip resistant and have similar frictional qualities to thye floor of lift landing to decrease the risk of stumbling. 30. The provision of mirror on the wall of the lift car opposite the lift door not extend below 900mm from the lift floor to avoid confusing people with impaired sight. 31. The emergency communication system should be coupled with an induction loop system installed all around the lift. Telephone units, where provided, should have an inbuilt inductive coupler to assist persons using hearing aids.
Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:- Brass Gland for Aluminium cable 2/3/4 Core size 10sq.mm
Supply, installation, testing and commissioning of Floor Extension of 1 Nos existing Otis make 13 passengers Elevators machine room less.from 1st floor to 2nd floor. SCOPE OF WORK:- 1. Car Rail: Best available cut length rail will be given. 2. CWT Rail: Std 5Mtr rail will be given. 3. Brackets: New Cwt and car rail brackets. 4. Door: This will be current Prima G door which will technically match. existing landing door. 5. New Belts. 6. New Gov Rope 7. New RBI to suit current belt. 8. New Hall fixture for all floors. 9. New T/C and H/W harnesses 10. New COP will be provided. Std. Govt. features.
XLPE INSULATED UN-ARMOURED CABLES (LOOSE):- Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- Overall size 16sq.mm (4Core) Un-armoured (Loose)
MCCB's (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc
d) Flushed
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-Overall size 16sq.mm (4Core) Un-armoured (On-Surface)
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.)
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long
Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface)
MS SHEET ENCLOSURE FOR MCCB's: Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Ap
prox. Size 500mm x 300mm x 200mm)
Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:-Cable End Box for SPN 8 Way
MCB Double Pole 6-32amp. (10kA, Curve-C)
Providing EPABX System:
Supply, installtion, testing & commisioning of IP based EPABX exchange. The proposed IP Based EPABX System shall be advance unified Communication system for Analog or IP Users and should be equipped with 1U Server with configuration Intel I5 Dual Core Processor , Dual Giga bit ETH Ports DDR4 8 GB RAM. 1TB SATA SSD , Support End points -IP phones, Analog Phones & Video Phones). VPN Server & Client Should be Built-in in the solution. Voice Mail & Voice Mail to Email for all users should be inbuilt in the system. Support IPV4 & IPV6 from Day one. The system should be configured for : 32 Anaog extensions, 4 Analog Trunks. EPABX has to be IP Ready . •LED Indicators (Power/Ready, Network, PSTN Line, USB, TF). Voice and Fax Codecs G.711 A-law/U-law, G.722, G.723.1 5.3K/6.3K, G.726, G.729A/B, GSM, AAL2-G.726-32; T.38,Video Codecs H.264, H.263, H263 i/c connection etc. complete as reqd. The quoted model/System should have Type Approval Certificate as per TEC specification number TEC/GR/SW/PBX-005/01/Sept-16 or latest. EPABX should be expandable up to 5000 analogue or IP users.complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, installtion, testing & commisioning of Operator console and PBX should be from same OEM. The operator console should have 4.3” 480 x 272 pixels main color display and 2 x 3.5” 320 x 480 pixels side color displays for DSS keys which delivere high-definition audio, wide band audio support,with advanced noise-cancelin feature for crystal-clearHD voice quality and feature advanced acoustic echo cancellation to minimize background noise.6-wayconference call, Buit in Bluetooth, Full-duplex hands-free speakerphone, Phonebook up to 2000 entries, complete in all respect as per satisfaction of the Engineer in charge of the work.
Providing and fixing of 4.5 Kg. Capacity FIRE EXTINGUISHER,CO2 type as per IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect
Supply, installtion, testing & commisioning of Sip Extension with its license for IP telephones complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply Installation Testing and Commissioning of Analog phone with caller id and hand free facility complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply Installation Testing and Commission
ing of 10 Pair DB with Original Krone Module lock & key facility complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.
Providing and fixing of 6 Kg. Capacity FIRE EXTINGUISHER, ABC Powder type (stored pressure) asper IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect
COPPER EARTHING 8SWG :- Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long
Supply Installation Testing and Commissioning of 20 Pair DB with Original Krone Module lock & key facility complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply Installation Testing and Commissioning of 50 Pair MDF with Krone for EPBAX side with Original Krone Module lock & key facility complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply, Installation Testing and commissioning of EPABX Rack chassis as per requirement 27U x 800W x 800D/ 1000D/ 1200D Floor Stand UL certified rack with Multi hollow extrusion Aluminium profile frame, Top and bottom cover with provision of either brush cable entry or cable entry holes with rubber grommets, Front single door with Glass/ Mesh and rear double door with mesh, Static load bearing capacity of Upto 1200KG., confirming to following standards - IEC EN 60529, IEC EN 62262, ISO 9001:2008, ISO 14001: 2015, ISO 45001: 2018, Salt spray test according to ISO 9227 (NSS test) for 250 Hours, Colour - Combination of RAL 7037 (For frame) & RAL 7035 (For other parts) with fine texture, Rack including accessories like Horizontal PDU, Metal Cable manager, Hardware packet and Monitor Shelf etc. should be from same OEM Floor Stand racks should be available in following dimensions. complete in all respects as approved and desired by the Engineer-in-charge at site.
RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Wiring Telephone socket point RJ11 (one module)
Supply and erection of telephone cable with solid bare copper conductor, special grade PE insulation, paired, polyster taped, nylon rip cord, FR PVC sheathed, conforming to TEC Specification No. G/WIR-06/03 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
Telephone Cable 0.5 Sq.mm, 2 Pair
Telephone Cable 0.5 Sq.mm, 20 Pair
Telephone Cable 0.5 Sq.mm, 50 Pair
HDPE Electrical Conduit Pipe 25mm dia. (Flushed)
HDPE Electrical Conduit Pipe 40mm dia. (Flushed)
Providing Networking System along with allied accessories:
Supply, Installation and Comissioning of Distribution Switch with minimum usable 24 10/100/1000BASE-T ports, 2 10GBASE-T ports , 4 10G SFP+ ports L3 Stackable Managed Switch with Redundant Power Supply Support.1 x RJ45 console port, RJ-45 port for out-of band-management port for accessing the CLI of the switch and USB port. 168 Gbps Switching capacity or higher or non-blocking architecture. 64 Bytes packet forwarding rate should be 125 Mpps or higher. Switch MAC table should be at least 16K or higher. Physical Stacking up to 9 units per stack. Stacking bandwidth up to 80G and up to 32 devices per virtual stack. Should have 802.1D STP, 802.1w RSTP and 802.1s MSTP Spanning Tree Protocol and ERPS as per standard ITU-T G.8032. BPDU Filter, BPDU restriction, Root restrction. Loopback detection (LBD). IGMP Snooping v1/V2/V3 & IGMP groups 1K or more IGMP groups and require support for IGMP Snooping Fast Leave. MLD Snooping v1/v2 & MLD group 1K or more and require support for MLD Snooping Querier. 16 L3 IP interfaces and IPv4/IPv6 Loopback interface. IPv6 Neighbor Discovery (ND). VRRPv3, Equal-Cost Multi-Path (ECMP) and UDP helper. Static route for both IPv4 and IPv6, OSPFv1, v2 & v3, RIP V1/V2/ng. Should have Policy-based Route (PBR). IEEE 802.1Q VLAN with different type of VLAN like Port based, Voice VLAN, Private, Double (Q-In-Q), Multicast VLAN (ISM VLAN for IPv4/IPv6), 802.1v Protocol VLAN ,VLAN Trunking. should have per-port broadcast, multicast, and unicast storm control to prevents faulty end stations from degrading overall systems performance. port security to secures the access port based on MAC address. Require prevention of DoS attacks, which include Land, Blat, TCP Null Scan, TCP Xmas Scan, TCP SYNFIN, Ping of Death Attack and TCP Tiny Fragment attack. DHCP snooping and DHCP server screening, DHCP server. 802.1X port based and 802.1X host based access control, Identity-driven Policy (VLAN, ACL or QoS) Assignment. RADIUS and TACACS+ authentication. Authentication database failover. QoS (quality of service) IEEE 802.1P for traffic prioritization. 8 queues per port. Different type of QoS priority like Strict Priority Queue and Weighted Round Robin, Strict + WRR, Congestion control using Weighted Random Early Detection (WRED) or WTD. Remark 802.1p priority, Remark ToS/DSCP and Rate limiting in Policy map. Support at least 2K ingress & 512 egress access control entries. ACL based on MAC, IPv4 and IPv6, TCP/UDP port number, User-defined packet contentm, CPU Interface Filtering. Able to manage trough Web-GUI, Fully functional CLI interf
ace and Telnet. Should have multiple Image and configuration support to reduced down time for the switches. sFlow for monitoring traffic in data networks, SNMP v1, v2c, v3 and SNMP Traps and RMON. Support for DHCP Client support for IPv4/IPv6, DHCP server, DHCP Relay and DNS client. Should have SNTP/NTP protocol for time synchronization. CDP/UDLD, Link Layer Discovery Protocol (LLDP) and LLDP-MED.. CDP/UDLD, Link Layer Discovery Protocol (LLDP) and LLDP-MED. Operating temperature should be 0 to 50 ˚C. Switch should be EMI Certificates FCC, CE and Safety Certifications cUL/UL, CB. All Switches, Wireless and its Networkiing Components from Same OEM. OEM Should be International certification for the ISO 45001 Health and Safety Management System, Information Security Management System: ISO 27001, ISO 9001 Quality Management System, ISO 14001 Environmental Management System, and ISO 14064-1 Greenhouse Gas Inventory Standards complete in all respect as per satisfaction of the Engineer in charge of the work.
Providing and fixing of 6 Kg. Capacity FIRE EXTINGUISHER, ABC Powder type (stored pressure) asper IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect
COPPER EARTHING 8SWG :- Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long
Supply Installation Testing and Commissioning of 20 Pair DB with Original Krone Module lock & key facility complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply Installation Testing and Commissioning of 50 Pair MDF with Krone for EPBAX side with Original Krone Module lock & key facility complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply, Installation and Comissioning of Category 6A Unshielded Twisted 4 pair shall be compliant with ANSI/TIA/EIA-568-C. 2 and & ISO/IEC 11081. , 10GBASE-T (10-Gigabit Ethernet) standard., Category 6A should operate on bandwidth up to 500MHz., Category 6A can run 10GBASE-T at 100 meters. The conductors should be twisted in pairs with four pairs and Insulation should be high density polyethylene., Copper conductor diameter should be 23 AWG., Cable outer sheath should be LSZH, Cable outer diameter should be 7.6mm ± 0.3mm., Electrical Properties - Conductor Resistance: ≤ 9. 38Ω/100m, Mutual Capacitance: ˂ 5. 6nF/100m, Resistance Unbalance: 5% Max, Delay Skew: < 45nS, Characteristic Impedance: 100 ± 15Ω, Mechanical Properties - Bending Radius should be 8 x cable diameter., Operating temperature Range 0°C to +60°C, Need to submit transmission characteristics report per 100 meter. The report at least includes Maximum Attenuation, RL, NEXT and PSNEXT data. OEM for the cable Box and all copper Accessories should be from same OEM.OEM Should be International certification for the ISO 45001 Health and Safety Management System, ISO 9001 Quality Management System, ISO 14001 Environmental Management System, and ISO 14064-1 Greenhouse Gas Inventory Standards. OEM should have Indian based operation at least for a period of 20+ years and should have an Annual Turnover of Rs. 500 Crores and above in any of last three consecutive Audited Financial years. (To ensure only principal networking companies participate having strong Product , Support and Service.) complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation and Comissioning of Patch Panel Cat 6 A UTP Keystone Type- 24 Port-Fully Loaded Category 6A UTP Patch Panel should be 24 Port 1U Size. , Mounts in standard 19 inch racks. , Patch panel should have cable manager for improvement management. , Patch panel should be made from SPCC and 1. 5mm or higher thickness with black colour painted. , RJ-45 Jack housing should be PBT + glass fiber, UL-94V-0. , RJ-45 Jack contact material should be phosphor bronze with nickel plated, RJ-45 Jack shield material should be phosphor bronze with tin plated. complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation and Comissioning of CAT6A UTP 24AWG PATCH CORD:1M Category 6A patch cords with four pair twisted cable terminated with RJ45 modular plugs at both the ends. Patch Cord should have TIA/EIA 568C. 2 standard. Shall be backward compatible with Category 5e and Category 6 systems. Category 6A patch cord should be 100% factory made and performance tested. Category 6A patch cord length requires – 1 meter & 3 meter. Patch cord conductor should be 24 AWG, multi-strands. , Patch cord conductor metal should be made from bare copper. , Jacket material should be LSZH. , Heat resistance of patch cord should be 75° Celsius. Modular Connector/Plug - Patch cord plug should be 50U gold plated. , Contact blade of plug should be made from copper alloy. , Category 6A patch cord plug should have maximum 500 MΩ, 1000V DC/min insulation resistance. , Dielectric withstanding voltage should be 1000V DC/min, <0. 5A. OEM for the cable Box and all copper Accessories should be from same OEM. complete in all respect as per satisfaction of the Engineer in charge of the wor
Supply, Installation and Comissioning of CAT6A UTP 24AWG PATCH CORD:3M Category 6A patch cords with four pair twisted cable terminated with RJ45 modular plugs at both the ends. Patch Cord should have TIA/EIA 568C. 2 standard. Shall be backward compatible with Category 5e and Category 6 systems. Category 6A patch cord should be 100% factory made and performance tested. Category 6A patch cord length requires – 1 meter & 3 meter. Patch cord conductor should be 24 AWG, multi-strands. , Patch cord conductor metal should be made from bare copper. , Jacket material should be LSZH. , Heat resistance of patch cord should be 75° Celsius. Modular Connector/Plug - Patch cord plug should be 50U gold plated. , Contact blade of plug should be made from copper alloy. , Category 6A patch cord plug should have maximum 500 MΩ, 1000V DC/min insulation resistance. , Dielectric withstanding voltage should be 1000V DC/min, <0. 5A. OEM for the cable Box and all copper Accessories should be from same OEM. complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation and Comissioning of Category 6A keystone jacks are RJ45, 8 position 8 contact socket. Category 6A keystone jacks are suitable for 22-26 AWG stranded and solid wire. Category 6A keystone jacks are compatible with both 110 & Krone punch down tools. jacks shall be backward compatible with Category 6, and 5e cords and cables. jacks shall be of a universal design supporting T568 A & B wiring. Mechanical Characteristics - Category 6A keystone jacks housing made from PC, UL94V-2. RJ45 Jack contact material should be phosphor bronze with Nickel plated. IDC contact material should be phosphor bronze with tin plated. OEM for the cable Box and all copper Accessories should be from same OEM. complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation and Comissioning of Face Plate should be able to terminate one Cat 6A keystone jack. Face plate material should be ABS with white colour. The face plates should have inbuilt shutter for protection against dust. Face plate should be able to supply with label holder. Screw and screw hole covers to be supplied with face plate. Should supplied with suitable back box. It should be made from HIPS / High plastic material. complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation, Testing and Commissioning of 27U Network Enclosure Frame-600X800-STEEL with accessories like fan, pdu, cable manager etc. Supply of 27U Enclosure Frame-800X1000-STEEL, Caster Wheels Set of 4 (2 with Brakes & 2 without Brakes),Adjustable Levellers set of 4, Glass Door-800-27U, Metal Door-800-27U-Vented, Side Panels-1000-27U-Vented, Mounting Hardware-(Pack of 20), FHU with 4 FAN 360CFM, Vertical Power Distribution Unit with 12 x 5/15 sockets Round Pin, 230 Volts AC, 32 Amp with Plug, Vertical Cable Manager-27U-Loop, Horz. Cable Manager-1U-Loop, Conforms to DIN 41494 OR equivalent ISO Standards, Adjustable 19” equipment mounting verticals provide the better mounting flexibility maximizing the usable mounting space, Depth adjustable mounting slots, Top and bottom Panel with ventilation and cable entry facility, Provision to mount the cooling fans on the top panel, Powder coated finish with pretreatment process meeting all industry standards, Grounding and Bonding Options can be provided, 100% assured compatibility with all equipment conforming to DIN 41494. General industrial standard for equipment, Conforms to DIN 41494 or equivalent standard, Welded Frame, Lockable Toughened Glass Door, Metal Vented Door Steel, DIN Standard 10mm Sq. Slots / Direct M6 Tap, 19” Mounting angles made of formed steel Powder Coated, Welded to Frame, Vented and Field Cable entry exit cut outs complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation, Testing and Commissioning of Wall Mount 15U x 600 W x 600 D ,Front Glass Door (tinted,Toughened) with Lock & Key, 2 pairs of 19" Mounting Rails with U-Marking , Welded Side Walls, Min Accessories : 1U Cable Manager (1), Hardware Packet (1 Pkt), 6 Socket 5 Amp. Power Distribution Unit (1 No), Roof Mounted Fan Unit / 90 CFM /230V AC.as per DIN 41494 Standards complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply and erection of Concealed Metal Boxes of various sizes (1/2M, 3M, 4M, 6M, 8M, 12M, 16/18M) with brass lugs recessed in wall for mounting modular accessories including fixing and other petty material etc., including the cost of cutting and filling up of chases (with finishing the surface):- Powder Coated Concealed Metal Box with Brass Lugs One/Two Module
Providing Fire Detection & PA System:
FIRE PANELS & ANNUNCIATORS:
Supply, installation, testing & Commissioning of Repeater Panel along with programming of existing court installed Fire alarm panel. The mimic annunciator for the fire alarm control panels (FACP). This provides the FACP with remote, serially-connected display. A five inch touchscreen display provides system status, point information, and event counters. The display shows two events simultaneously, and pages through up to 50 of the highest priority events in the system. The RLD also provides system control with six programmable softtouch buttons as well as Acknowledge, Silence, Reset and Drill. (CAMC of 2 Years after completion of one year defect liability period) complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installatio
Supply, installation, testing & Commissioning of Loop Cards Class A Wiring with min. supporting cable length Up to 1.2 Km UL & FM Approved .It includes the (CAMC of 2 Years after completion of one year defect liability period).complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Addressable photo-Thermal multi criteria Detector and base with sensitivity range as per NFPA 72. The intelligent detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary/ Electronic decimal switches. Designed to meet UL & FM Approved . The solution should be from single OEM. It includes the (CAMC of 2 Years after completion of one year defect liability period)complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Reponse Indicator for up side of ceiling Detectors complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Addressable Smoke photo-Thermal Detector and base with sensitivity range as per NFPA 72).The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signa! of the photoetectric signal in an effort to react hastily in the event of a fire situation. It shall aiso include the inherent ability to distinguish between a fire condition and a fa'se alarm condition by eramining the charactenstics of the tnermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary/ Electronic decima! switches. Designed to meet UL & FM Approved The solutien should be from single OEM. It includes the (CAMC of 2 Years after completion of one year defect liability period) complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Addressable High Sensitivity Photo Detector with sensitivity level as per NFPA 72( 0.02% to 2%) Mandatory for critical roomns .The detector shall have the optic block to amplify signals from smoke, but diminish stray intemnal refiections tha: can cause faise alarms. The detector should have on board difit compensation, transient rejecion algontms with supeniro EMI protection. The detector shait have bi-cclour LED for 360 deg viewing. Addressing shall be with user friendly rotary / Electronic decimal swiches Designed to meet UL & FM Approved The solution sheuld be from single OEM. It includes the (CAMC of 2 Years after completion of one year defect liability period)complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Addressable wireless mesh technology based Multi-cntena Photo-Thermal Detector with sensitv.ty range as per NFPA 72( 0.5 to 4% obs/ft) The detector shall work within the leg.timate working freequency band between 885 Mhz to 857 MHz The detector shas ceable to communicate with the wireless gateway. The inteiligent multi eriteria detecton device shall include the ability to combine the signat of the therma sonsor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation, It shall alse include the inherent ability to dstngush between a fire condition and a false alarm condition by examining the characteristics of the thermai and smoke sensing chambers and cemparing them to a detabase of actual ive and deceptive phenomena. The detector shall have bi-colour LED for 360 deg viewing. Addressing shall be with user fnendly rotary! Electronie decimal swilches Designed to meet UL & FM Approved The solution should be from single OEM. It includes the (CAMC ef 2 Years after) compietion of one year defect liabilty period) complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Addressable Rate of Rise Heat Detector rated at 8.3 deg C/min.NFPA 72. The detector shall have bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary/ Electronic decimal switches.UL & FM Approved The solution should be from single OEM. It includes the (CAMC of 2 Years after completion of one year defect liability period) complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Addressable Manual Call Point (Pull down / Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device complete in all respects as approved and desired by the Engineer in-charge at site.UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and Min.110 cd flashintg at 1 Hz for visual indication. UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes/ Telephone Jack. The control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary / Electronic decimal switches UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Monitor Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary/ Electronic decimal switches UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device.UL & FM Approved Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.The solution should be from single OEM.complete in all respects as approved and desired by the Engineer in-charge at site.
Providing and fixing of 6 Kg. Capacity FIRE EXTINGUISHER, ABC Powder type (stored pressure) asper IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect
Supply, installation, testing & Commissioning of Addressable Relay Module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppre
ssion & other Third Party Outputs. The relay module shall provide contact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary/ Electronic decimal switches UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Addressable Fire Fighter's Telephone Jack for two way communication between Remote Fire Fighter & Fire Command Center UL Listed .It includes the (CAMC of 2 Years after completion of one year defect liability period) complete in all respects as approved and desired by the Engineer in-charge at site. complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Addressable loop powered gateway module capable of connecting 31 devices. The gateway module shall form a hybrid mesh wireless network with the detectors/devices as per the OEM limitation. The module shall comply UL guideline. The solution should be from single OEM. .It includes the (CAMC of 2 Years after completion of one year defect liability period) complete in all respects as approved and desired by the Engineer in-charge at site. complete in all respects as approved and desired by the Engineer in-charge at site.
Supply,installation, testing & Commissioning of Digital Audio Amplifier with transformer as per site requierment . Amplifier shall be capable of N:N/N:1 configuration and shall be dual channel capable of processing Two of 8 audio channels and a total of Min 95 W ( It may be 1 unit or Combination of Multiple units to achieve the Requirement) at 70.7 VRMS output along with necessary enclosures with local FFT Raiser. The Digital Audio Amplifier shall be fully monitored for fault and alarm reporting. The proposed Digital Audio Amplifiers shall be (Wall/Panel Mounted). Integrated 8 channel Digital Voice Evacuation System Controller (as per requierment) capable of broadcasting Evacuation Messages on the same peer-to-peer Network and 2 ways Communication capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC/Amplifier operation. Products not having this feature must provide dedicated CPU for DVC. The Evacuation System Controller shall have FFT Risers to control and conference minimum 30 Telephones.. Amplifiers shall be distributed across the building/floor to manage the sound attenuation problem & for the best sound intelligibility. All amplifiers can be back up of minimum 5 hours using secondary power source(battery power/UPS power) It includes the (CAMC of 2 Years after completion of one year defect liability period) complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of 2W Multi-Tap (0.25W; 0.5W; 1W; 2W), Ceiling/Wall Mount Speakers. The speakers shall be of the same make as that of the Control Panel & Amplifiers. They shall be compatible with supplied Amplifiers and shall work on 70.7Vrms UL Listed.It includes the (CAMC of 2 Years after completion of one year defect liability period) complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Back Box for 2W Multi-Tap (0.25W; 0.5W; 1W; 2W), Ceiling/Wall Mount Speakers.It includes the (CAMC of 2 Years after completion of one year defect liability period) complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Exit LED M ST LED based exit sign with dimming function, Reading distance, exit sign Two-sided 25m, Voltage 220-240VAC / 50-60Hz, Power consumption 3.3W / 3.5VA, Battery 3.6V/1.2Ah NiMH, Battery protection Over charge protection /deep discharge protection, Charging Time 16 hours, Battery back-up time 1 hour / 3 hours / 8 hours (from dip switch), Light source 15 LED, Approvals EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, Ambient temperature 5 to 40 °C, Humidity Up to 95%, IK rating IK09, IP rating IP40, Dimensions 265 x 53 x 222 mm, Weight 540 / 742 gr , Colour Anodized aluminum / black plastic, Materials Aluminum, Acrylic Plate, Mounting method Ceiling, wall bracket, suspended, pendulum, flag mount, Delivered as self-contained/auto test luminaire Choice of 1, 3 or 8 hour autonomy via DIP switch IP 40 – dustproof luminaire Reading distance upto 25 meters.High lumen output – 1h = 180lm / 3h = 110lm /8h = 40lm Technical lifetime of LED > 100 000 hours , 4 Pictograms (left, right, down, up) are included in the luminaire ordering part code.It includes the (CAMC of 2 Years after completion of one year defect liability period) complete in all respects as approved and desired by the Engineer in-charge at site.
Supply, installation, testing & Commissioning of Online UPS 1 kva 800 Watts Tower UPS with 1 hour battery backup. Operating Temperature Range 0 to 40 Degree @ 100% Load @ 50 Degree with 50% Load,Storage Temperature -15°C~60°C, Relative Humidity 0-95% No condensates, Acoustic Noise 40 dBA @ 1 Meter, Cooling Forced air cooling by the internal fans, Input Socket IEC C13, Output Socket IEC C14, No of output sockets 3 No's, Rated Input Voltage 208/220/230/240 Vac, Maximum working input voltage range 160 to 300 Vac @ 100% Load, 100 to 300 Vac @ 50% Load, Input Power Factor 0.99, Input THDi% 5%, Generator Set Yes 1.5 x UPS Capacity, Rated kVA 1000 VA, Rated kW 800 Watts, Load type Resistive load/ lagging load/ non-linear load/ transformer load/ lighting load, Load power factor range 0.5~1 lagging, Load Crest Ratio 3:1, Online Efficiency 88%, Rated Battery Voltage 36 Vdc, Battery Type VRLA (Valve Regulated Lead Acid Battery), 12VDC, Battery backup Back UP : 936VAH, Maximum charging current 10 Amps, ECO Mode Available, Communication (Independent SCI) Available, Intelligent Card slot (Independent SCI) Available, OVCD Available, EPO Function Available, Intelligent Fans Speed control Available, Auto restart function Available, Cold start Available.It includes the (CAMC of 2 Years after completion of one year defect liability period) complete in all respects as approved and desired by the Engineer in-charge at site.
PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (48/0.20mm), 2Core
Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:- SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 200mm x 140mm x 95mm with hinged water tight cover with locking arrangement (For Flood Lights on Parapet wall).
Additional Length 20mm x 3mm thick Copper Tape .
Supply and erection of fire survival cable for fire alarm & PA system with annea
led stranded copper conductor, fire resistant mica tape wrapped (at 950°C for 180 minutes), XLPE insulated, LSHZ (low smoke & zero halogen) bedding, LSZH (low smoke & zero halogen) red outer sheath, galvanized steel wire armour, 600/1000 volts grade, Fire resistant to IEC 331 & BS7846 F2/BS6387 & CWZ, Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332-3) left bare in pipe or casing or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- Fire Survival cable 2Coe x 1.5 sq.mm
80mm i/d Sluice Valves flanged
MCCB Four Pole 40/63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MCCB Four Pole 250amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
Supply, Installation, Testing & Commissioning of 1 KVA UPS with Input power factor - 0.99, Output power factor - 0.8, OVCD inbuilt , DC V 36v, Efficiency : Above 90% complete in all respects as approved and desired by the Engineer in-charge at site.
HEAVY GUAGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- Heavy gauge welded conduit pipe 25mm dia. (ISI marked 1.60mm thick) Flushed
PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
Providing PA For Court Rooms_:
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge).
Old to new connection with CI specials
Providing Flood Lighting:
XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- (For Flood Lights) Overall size 10sq.mm (3Core) Un-armoured (On-Surface)
Supply, Installation, Testing & Comissioning of Amplifier Power Output:100W Max. THD. Output Regulation:≤ 2 dB, no load to full load at 1kHz. Input Channels: 5 X Mic 0.65mV/4.7kΩ, 2 X Aux 100mV/470KΩ. Frequency Response: 50-15,000Hz ± 3dB. Signal to Noise Ratio: 60dB. Tone Controls: Bass: ±8dB at 100Hz, Treble: ±8dB at 10kHz. Output: Preamp 200mV/600Ω, Line 1V/1kΩ. Speaker Output: 4Ω,8Ω,16Ω,70V & 100V. Digital Player: MP3 Player wih USB, SD & MMC Card Reader, Bluetooth. Power Supply: AC:220-240V 50/60Hz, DC:12V(12V Car Battery). Power Consumption: AC: 250VA DC: 5.5A. complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation, Testing & Commissioning of Speaker Power Rating: 50W Max. Power Taps: 30/20/10W. Impedance/Voltage: 80Ω/100V. Frequency Response: 50-20,000Hz. SPL at 1KHz (1W/1m): 87dB. Speaker: Woofer 163mm (6 ½"), Tweeter 25mm (1"). Dimensions: W215 X H310 X D175 mm. Weight: 3.80Kg(approx.) complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- Aluminium thimble cable Core size 10 -16sq.mm
Supply, Installation, Testing & Commissioning of Mic Frequency Response: 100-15,000Hz, Impedance: 1000Ω, Sensitivity: 7.0mV/Pa. Power Source: 3V-9V DC. Overall Length: 460mm(18") complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation, Testing & Commissioning of Mic Stand Heavy Duty Base, XLR Connector, 10m Twin Core shielded , 6.3mm (¼") phone plug, On/Off Switch . complete in all respect as per satisfaction of the Engineer in charge of the work.
Supply, Installation, Testing & Commissioning of Mic Cabling (5 Mtr) with connector
Overall size 1.0sq.mm (32/0.20mm), 2Core
Providing 1Nos. 160KVA Silent Diesel Generating Sets with Manual Control Panel:
Supply, Erection, Testing and Commissioning of Silent (Sound Proof) Diesel Generator Set 160 KVA /128KW with Manual Control Panel .It should be air cooled/water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard). ENGINE: The Diesel engine developing 310 BHP (Approx.) for giving a power rating as per ISO 8528- Part-1 ( With CPCB-IV+ Norms as amended upto date) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements. ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication and MCCB (Fixed Thermal and Adjustable Thermal protection) of suitable rating for outgoing supply. ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use.
ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be IP54 Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc.with 2 year warranty from the date of installation. complete in all respect as desired by engineer at site:-The Generator set should be instaaled at site on the suitable size existing plinth of RCC as per specifacation DG set as per satisfacation of the Engineer- in-Charge at site. The model of engine will be decided by the Engineer in Charge. MANUAL CONTROL PANEL: Manual control panel shall be fabricated out of 1.6 mm sheet steel, totally enclosed, dust, damp and vermin proof wall mounted/ free standing floor mounted type with IP-53 degree of protection & front operated, composite meter for digital display, HRC fuses of suitable rating. MCCB (Fixed Thermal and Adjustable Thermal protection)/ ACB (Over cuurent/ overload, shorcircuit, instantenous, earth fault protection) should be used. Battery charger complete with voltage regulator, Voltmeter and Ammeter for charging the battery from external mains. This will be in addition to the battery charging alternator or dynamo fitted on the engine.All the components in the control panel shall be properly mounted, duly wired and labeled. Suitable terminals are
to be provided for panel incoming and outgoing connections. System opeartion facility provided shall afford the following operational requirements. Necessary instruments and accessories such as voltmeter, power factor meter, KW meter, KWH meter, Ammeter, Frequency meter,battery charger complete in all respect as desired by engineer at site:-
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- Double Walled Corrugated HDPE Pipe 160/ 136mm (Outer/ Inner dia.)
COPPER EARTHING
PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (Un-sheathed)
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- Double walled corrugated (DWC) HDPE pipe 63/51mm (outer/ inner dia.)
MS SHEET ENCLOSURE FOR MCCB's: Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm)
MCCB's (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- MCCB Four Pole 63amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
Dismantling Sanitary fixtures such as Eurpoean/Indian/Orissa W.C., PVC / China ware cistern, Wash Hand Basin, Urinal Pot, Sinks and CP Fittings and disposal of dismantled material within a distance of 100 Mtr. complete in all respect as required by Engineer-in-Charge.
Eurpoean/Indian/Orissa W.C.,
PVC / China Ware Cistern
Wash Hand Basin / Urinal Pot
12.5 mm thick cement plaster 1:5 complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge.
Elbow 90 Degree (All side socketed)
Vent Cowls
Coupler
CP Bib Cock/Angle Cock/Stop Cock/Shower/Bottle Trap
Bathroom Assessories such as Soap Dish, Towel Rail, Towel Ring, Towel Bracket, Mirror, Toilet Paper Holder, Seat Cover, Jet Pressure and all other accessories.
Coupler
Dismantling of wall tiles at any floor of the building, laid in cement mortar including scraping of cement plaster and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect
Single Tee With Door
Elbow 90 Degree (All side socketed)
Vent Cowls
Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect.
Removal of Cinder from 1st floor including disposal (labour rate only)
Dismantling H.C.I Soil pipes including disposal as desired by the Engineer-in-Charge.
100mm i/d H.C.I. pipe
75mm i/d H.C.I. pipe
Credit of old material complete in all respects
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type B
110mm o/d single socket SWR UPVC pipe lines laid complete
90mm o/d single socket SWR UPVC pipe lines laid complete
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.
For 110mm i/d pipes
P Trap/Floor Trap 110mm x 110mm
For 90mm o/d pipes
Elbow 90 degree (all side socket)
Single Tee
Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge )
SDR 11 CPVC pipes & fittings 20mm o/d
Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting.
Core cutting in RCC slab 125mm dia or 150mm dia withe the help of core cutting machine as per requirement at site & as desired by Engineer-in-Charge.
Providing and fixing galvonised hanging clamp 100mm dia chimney type for PVC pipe, 12mm galvonised fully thread bar with nut bolt as per requirement at site & as desired by Engineer-in-Charge.
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.
450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal
600mm x 900mm inside with 455mm x 610mm cover and frame light duty double seal
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber includin
g cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm
100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm
CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm
Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.
Size 49 cm dia (above counter round)
Through wall 11.43 cm thick
Providing, fixing and jointing Cpvc Union Couplings with Upvc Pipes complete in all respect.
25mm i/d Cpvc Union
Providing, fixing and jointing CPVC Ball valves screwed with CPVC ball & spindle & Teflon seats, on CPVC Pipe lines including all carriages complete.
25mm i/d CPVC Ball valves
Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
Chinaware wall mounted E.W.C without cistern including seat cover complete in all respect.
Providing and fixing in position concealed cistern including flushing plate of approved make (to the approval of the Engineer-in charge) complete in all respec
Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge.
Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
Providing and fixing jet spray with 2'-6" long PVC pipe.With C.P. Brass nut
Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect.
Size 550 mm x 400 mm x 815mm
Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete.
Vitreous white Chinaware Partition Large partition size 75 x 16.5 x 36.5 cm
Providing and fixing in position vitreous Chinaware white channel of approved make (to the approval of Engineer-in-charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect.
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.
C.P brass towel ring
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect.
Table Top (size 49 x 40 x 15 cm)
Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 300 mm with PTMT nut
Providing and fixing in position C.P. brass bottle trap 32mm dia with 40 mm seal of approved make (to the approval of Engineerin- charge) complete in all respect.
Providing and fixing P.V.C Waste Pipe Collapsible 32mm complete in all respect.
Providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect.
Rectangular Sink with Deluxe Border Single Bowl Overall Size 555 mm x 475mm x 200 mm
C.P.brass 15mm Angle valve without flange
Providing and fixing in position C.P brass basin mixer without pop-up waste system with 450 mm long flexible hose of approved make (to the approval of Engineer-in-charge) instead of C.P. brass pillar tap complete in all respect
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.
C.P. brass towel Rails size 15mm dia 610mm long
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.
C.P. brass Bib cock foam flow without flange
Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.
C.P.brass 20mm Concealed stop cock with flange
Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. Brass fittings:
C.P brass Sink mixer with swinging spout.(wall mounted)
Providing and fixing Stainless steel health faucet complete in all respect.
Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect.
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect. C.P. Brass extension piece, 25mm long to 50mm long
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm)
Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. Brass Accessories:
Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. C.P. Brass khunti with 3 pegs
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Tripple Layer Tanks
Providing and fixing in position automatic brass Ball Cock in tanks. Plastic Ball Cock with rod and Plastic Ball
Extra Rate for First Floor
Extra Rate for Second Floor
Providing and fixing in position CPVC Tank Nipple of approved make (to the app
Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P. Brass Accessories:
Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. C.P. Brass khunti with 3 pegs
roval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.
CPVC tank nipple 25mm i/d
Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects.
Platform for HDPE Water Storage Tank complete in all respects
For 2000 Ltr capacity
For 1000 Ltr capacity
Providing and fixing in postion storage type automatic electric water heater pressure type thermostatically controlled, single phase wall mounted of approved make (to the approval of Engineer-in-charge) with thermostats, inner container of stainless steel, Inner glass lining with B-Rating minimum 3 stars complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect. Vertical Type
25 litre capacity water heater
Supplying and filling cinder on roof (Ist story) including light ramming
Screed of 50mm thick cement concrete 1:8:16 with stone aggregate to be laid below the topping.
Extra rate for First Floor
Extra rate for Second Floor
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg /sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/ sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Area same as screed of all the floors
Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete .
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending.) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and ramps.
Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.)
Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Water Cooler Semi Steel Body 80/120 ltr Capacity without Stablizer
Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect.
COPPER EARTHING (Upto 14 metre in Length):- iii- Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iro
Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect.
Platform for water coolers complete in all respects
AUTOMATIC VOLTAGE STABLIZER Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:-
Automatic Voltage Stablizer 3 KVA
Providing & Fixing M.S./G.I. Shed for outdoor water cooler including material & carriage complete in all respects
EXTERNAL IN THE GROUND : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, & testing of joints excluding cost of excavation complete as per direction of Engineer-in-Charge.
CPVC SDR 11 pipe & fittings 25mm o/d
EXTERNAL IN THE GROUND : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, & testing of joints excluding cost of excavation complete as per direction of Engineer-in-Charge.
Credit of old material complete in all respects
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.
110 mm o/d pipes
Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watchi
ng, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.
Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work.
For covering sewer line type II
For Sewer Line 100 mm dia as per Detail attached
Providing & Installing & Erection split type wall mounted inverter type air conditioner capacity 1.50 tonne 5 Star of Reputed Make without voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of 3 mtr concealing Copper pipes within building and installing charges complete in all respects as per Satisfaction of Engineer-in-charge. Min. cooling capacity 5280 W
Providing , Installing & Erection split type wall mounted inverter type air conditioner capacity 2.0 tonne 5 Star of reputed Make without voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of 3 mtr concealing Copper pipes within building and installing charges complete in all respects as per satisfaction of engineer-in-charge. Min. cooling capacity 6200 W
Providing laying hard soft copper concealing of copper pipes of dia 12.7mm od (insulation = 13mm)/9.5mm od (insulation = 13m) as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within the building and installing charges complete in all respects.
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. Size 75 mm x 75 mm
Providing and installing in position of sanitary nakin vending machine with incinerators including all accessaries complete in all respects
Contruction of 1 No. Underground storage reservior of capacity 50000 L including Pump Chamber per drawing complete in all respects
M.S PIPE (On Surface) Providing, laying, fixing, testing and commissioning of 'C' Class heavyduty MS Pipe conforming to Indian Standard C295IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nutsbolts, gasketsetc.onsurface and providingangle iron support or cement concrete block as support including painting with two or more coats of synthetic enamel paint of required shade complete in all respects.
M.S PIPE (On Wall) Providing, laying, Fixing, testing and commissioning of "C" Class heavy duty MS pipe Confirming to Indian standard IS. 1239/3589 including fitting like tees, bends, sockets, elbows, flanges,tapers, nuts bolts, gasket etc. fixing the pipe on the wall/ ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects.
HYDRANT LANDING VALVE Supplying,Installation, Testing & Commissiong of G.M Single headed hydrant valve with instantaneous Gun metal peet Coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5299 (typeA) with blank Gunmetal cap and chain includung orifice plate made of 6mm the stainless steel to keep the pressure not more than 3.5 per sqcm at any point complete in all respect.
BRANCH PIPE Supplying , installation, testing and commission of 63 mm gun metal Branch pipe(ISI marked) with 20mm(normal internal dia) size gunmetal nozzel confirming to IS 903, suitable for instantaneous connection to interconnection hose pipe coupling as required.
FIRE BRIGADE INLET Providing & fixing Fire Brigade inlet connection of cast iron body with gunmetal 63mm dia instantaneous type male couplings with built-in check valves and 150mm dia, flanged outlet complete with bolts, nuts and rubber insertions as per IS:904.
EXTERNAL IN THE GROUND : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, & testing of joints excluding cost of excavation complete as per direction of Engineer-in-Charge.
Providing & Fixing M.S./G.I. Shed for outdoor water cooler including material & carriage complete in all respects
Four way inlet connection
RRL HOSE PIPE Supplying , installation, testing and commission of RRL fire hose type A, IS: 636, 63 mm dia x 15 m long with gun metal male and female coupling(ISI marked) bound & riverted to hose pipes with copper rivets and copper wire as required.
FIRST AID HOSE REEL Supplying, installation, testing and commissioning of First-Aid-fire Hose reel with MS construction spray painted in post office red, confirming to IS 884 with opto date amendmets, complete with rubber hose pipe (IS:444/1987) 20 mm dia 30 meter long type-2, hose reel drum with bracket as per Is:884, 20mm dia GM nozzle and 20mm dia GM gates valve as required with complete with G.I pipe connection with main pipecomplete in all respect.
HYDRANT BOX Supply, installation, testing & Commissioning of weather proof cabinet for hose fabricated out of 1.6mm thickness M.S sheet with the front glass door having locking arrangement, suitable to accomadate all the necessary pipes, accessories, fitting etc. including painting the metal portion with one coat of ready mixed primer paint and two enamel coats of synthetic paint of all approved quality,shade and sign writing etc.
750mm wide x 600mmhigh x 250mm deep
Supplying & fixing air vessel made out of 250mm. Dia, 8 mm thick MS sheet, 1200mm height with air release valves on top and flanged connection to risers, drain arrangements with 25 mm dia gunmetal wheel valves, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required
PRESSURE SWITCH Providing & fixing of pressure switch of approved make in MS pipe line suitable for line pressure up 15kg/cm2 & including connection with main panel etc as required complete in all respect.
PRESSURE GAUGE Providing & fixing S.S Pressure Guage complete as required complete in all respect.
Dia diameter 100mm calibration 0-16kg.
GM BALL VALVE Providing, fixing and jointing Brass Ball Valves screwed with SS/Brass ball spindle & teflon seats on G.I. Pipe lines including all carriage complete.
25 mm Dia
ABC TYPE FIRE EXTINGUISHER Providing and fixing of FIRE EXTINGUISHER,ABC Powder type(stored pressure) as per IS: 15683 complete with all accessories as per manufactures specification ISI mark complete in all respect. CAP. 6 kg
CO2 TYPE FIRE EXTINGUISHER Providing and fixing of FIRE EXTINGUISHER,Co2 type as per IS: 15683 complete with all accessories as per manufactures specification ISI mark complete in all respect. CAP. 4.5KG
BUTTERFLY VALVE Supplying, Laying, Testing & Commissioning of ISI marked BUTTERFLY VALVE PN 1.6, with rubber Gun Metal seal duly ISI marked complete with rubber insertionn, nuts, bolts and washers, matching flanges of required thickness, etc complete as per specification.
100 mm Dia
150 mm Dia
NON RETURN VALVE Providing & fixing Dual plate check valve flanged and class PN-1.6 as per IS with nitrile seat SS shaft & spring in pipe lines including joining & cost of nuts, bolts, rubber insertion etc complete.
HYDRANT PANEL Providing & fixing of Hydrant Electrical Panel of cubical type floor mounted 16 Gauge including cable. Complete in all respect.
MOTOR PUMP Providing and fixing of Pump 450Lpm at 30m Pump Set consisting of KBL HES Pump , MOC: CI casing, Br. Impeller, CS Shaft , Mech. Seal. BBL Make 7.5kw/2P, IE2 TEFC SCIM MS Heavy Base Frame, Rathi PB RB 116 Coupling complete in all respect.
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.
Triple Layer Tanks
Construction of platform for terrace tanks for 5000 lts complete in all aspects including material, labour etc.
Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.
Providing and fixing in position automatic b
rass Ball Cock in tanks. Brass Ball Cock with rod and Plastic Ball
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.
Earth work upto 1.5 m. Depth All classes of soil except rocky
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.32 MB
SBD1.pdf
Tender Documents • 16.87 MB
Technicalcondition.pdf
Additional Documents • 24.76 MB
BOQ_310616.xls
BOQ • 0.90 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .