Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.8 LAdmitted-Finance | ₹35.8 L | L1 | Admitted-Finance |
| 2 | L2₹36.5 L+₹71,666.44 (2.00%)Admitted-Finance | ₹36.5 L+₹71,666.44 (2.00%) | L2 | Admitted-Finance |
| 3 | L3₹40.2 L+₹4.4 L (12.3%)Admitted-Finance | ₹40.2 L+₹4.4 L (12.3%) | L3 | Admitted-Finance |
| 4 | L4₹42.9 L+₹7.1 L (19.7%)Admitted-Finance | ₹42.9 L+₹7.1 L (19.7%) | L4 | Admitted-Finance |
| 5 | L5₹43.5 L+₹7.6 L (21.3%)Admitted-Finance | ₹43.5 L+₹7.6 L (21.3%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SHILPA CONSTRUCTION COMPANY L5 | M/S Harika enterprises L1 | PASAYDAN ELECTRICALS L4 | REVANTH ENTERPRISES L6 | Brite electricals L3 | VAISHNAVI ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down the unserviceable power factor capacitors of different capacities from the capacitor panel board after disconnecting the electric supply, Supply and fixing of power factor correction capacitors, All Poly Propelene (APP) Box type, (LTBCU), rectangular in shape, heavy duty, with over current withstand capability 3 x In, operating losses 0.35 W / kVAr, peak inrush current withstand capability 500 x In, number of switching operations per year : 20000, maximum ambient temperature 70 degree celcious, minimum operating life 300000 hours, various KVAR rating, 440 V, with suitable fixing arrangement including connection with suitable copper cables and testing complete all as specified and directed.
Note : (i) Capacitors shall conform to IEC 831-1, with total losses not more than 0.25W / KVAR.
(ii) Copper cables, thimbles will be measured and paid for seperately under respective items.
Make : Cat No LTXL (Box series : LTBCU) of make L&T or equivalent model | 1,800 | KVAR | 897 ₹16,14,600 | 741.6 ₹13,34,880 Lowest | 800 ₹14,40,000 | 987.07 ₹17,76,725.28 | 830 ₹14,94,000 | 756.43 ₹13,61,577.6 |
| 2.00 | All as per Sl Item No 2 above, but cylindrical type (LTCCU) | 1,475 | KVAR | 798 ₹11,77,050 | 650.16 ₹9,58,986 Lowest | 700 ₹10,32,500 | 865.36 ₹12,76,410.37 | 730 ₹10,76,750 | 663.16 ₹9,78,165.72 |
| 3.00 | Monthly Servicing of Automatic Power Factor Corrections (APFC) panel of capacity 75 kVAr complete, comprising of any type capacitors, APFC relay, MCCB, cooling fan, Volt meter, Ammeter, CTs with all other connected accessories, checking of serviceability of each component, cleaning of all contact points, tightening of all connections including replacement of unserviceable components, thimbles, nut, bolt & washers etc if necessary, cleaning the entire panel by using the hot blower complete all as specified and directed by Engineer-in-Charge. (For 05 panels)
Note : MCCB, MCB, capacitor if any replaced shall be measured and paid seperately. | 6 | Job per Month | 3,210 ₹19,260 | 2,691.36 ₹16,148.16 Lowest | 4,000 ₹24,000 | 3,582.2 ₹21,493.2 | 2,970 ₹17,820 | 2,745.19 ₹16,471.12 |
| 4.00 | All as per Sl Item No 3 above, but 100 kVAr. (For 03 panels) | 6 | Job per Month | 2,400 ₹14,400 | 2,049.84 ₹12,299.04 Lowest | 3,000 ₹18,000 | 2,728.34 ₹16,370.02 | 2,265 ₹13,590 | 2,090.84 ₹12,545.02 |
| 5.00 | All as per Sl Item No 3 above, but 150 kVAr. (For 03 panels) | 6 | Job per Month | 3,003 ₹18,018 | 2,484 ₹14,904 Lowest | 3,600 ₹21,600 | 3,306.2 ₹19,837.22 | 2,735 ₹16,410 | 2,533.68 ₹15,202.08 |
| 6.00 | All as per Sl Item No 3 above, but 175 kVAr. (For 02 panel) | 6 | Job per Month | 2,067 ₹12,402 | 1,726.56 ₹10,359.36 Lowest | 3,000 ₹18,000 | 2,298.05 ₹13,788.31 | 1,901 ₹11,406 | 1,761.09 ₹10,566.55 |
| 7.00 | All as per Sl Item No 3 above, but 185 kVAr. (For 01 panel) | 6 | Job per Month | 1,077 ₹6,462 | 898.56 ₹5,391.36 Lowest | 1,600 ₹9,600 | 1,195.98 ₹7,175.9 | 999 ₹5,994 | 916.53 ₹5,499.19 |
| 8.00 | All as per Sl Item No 3 above, but 200 kVAr. (For 06 panels) | 6 | Job per Month | 7,035 ₹42,210 | 5,837.76 ₹35,026.56 Lowest | 10,200 ₹61,200 | 7,770.06 ₹46,620.35 | 6,440 ₹38,640 | 5,954.52 ₹35,727.09 |
| 9.00 | All as per Sl Item No 3 above, but 225 kVAr. (For 03 panels) | 6 | Job per Month | 3,651 ₹21,906 | 3,022.56 ₹18,135.36 Lowest | 5,400 ₹32,400 | 4,023.03 ₹24,138.16 | 3,250 ₹19,500 | 3,083.01 ₹18,498.07 |
| 10.00 | All as per Sl Item No 3 above, but 250 kVAr. (For 09 panels) | 6 | Job per Month | 11,400 ₹68,400 | 9,398.16 ₹56,388.96 Lowest | 17,100 ₹1,02,600 | 12,508.95 ₹75,053.71 | 10,550 ₹63,300 | 9,586.12 ₹57,516.74 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
4 Aug 2026, 6:00 pmClosed
GE(I) R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
REPAIRS REPLACEMENT OF HT SWITCH GEARS 11 KV OVERHEAD LINES LT PANELS AND LT SWITCH GEARS AT ELSEC CPDC CHESS DSC AND RESIDENTIAL AREA UNDER GEI RND RCI HYDERABAD
2026_MES_778352_1
8446
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(I) R AND D RCI
MES enlisted Class D category b ii Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE(I) R AND D RCI, HYDERABAD
₹96,000
Yes
20 Aug 2026
14 Jul 2026
6 Aug 2026
14 Jul 2026
4 Aug 2026
28 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down the unserviceable power factor capacitors of different capacities from the capacitor panel board after disconnecting the electric supply, Supply and fixing of power factor correction capacitors, All Poly Propelene (APP) Box type, (LTBCU), rectangular in shape, heavy duty, with over current withstand capability 3 x In, operating losses 0.35 W / kVAr, peak inrush current withstand capability 500 x In, number of switching operations per year : 20000, maximum ambient temperature 70 degree celcious, minimum operating life 300000 hours, various KVAR rating, 440 V, with suitable fixing arrangement including connection with suitable copper cables and testing complete all as specified and directed.
Note : (i) Capacitors shall conform to IEC 831-1, with total losses not more than 0.25W / KVAR.
(ii) Copper cables, thimbles will be measured and paid for seperately under respective items.
Make : Cat No LTXL (Box series : LTBCU) of make L&T or equivalent model | 1,800 | KVAR | - | - |
| - | All as per Sl Item No 2 above, but cylindrical type (LTCCU) | 1,475 | KVAR | - | - |
| - | Monthly Servicing of Automatic Power Factor Corrections (APFC) panel of capacity 75 kVAr complete, comprising of any type capacitors, APFC relay, MCCB, cooling fan, Volt meter, Ammeter, CTs with all other connected accessories, checking of serviceability of each component, cleaning of all contact points, tightening of all connections including replacement of unserviceable components, thimbles, nut, bolt & washers etc if necessary, cleaning the entire panel by using the hot blower complete all as specified and directed by Engineer-in-Charge. (For 05 panels)
Note : MCCB, MCB, capacitor if any replaced shall be measured and paid seperately. | 6 | Job per Month | - | - |
| - | All as per Sl Item No 3 above, but 100 kVAr. (For 03 panels) | 6 | Job per Month | - | - |
| - | All as per Sl Item No 3 above, but 150 kVAr. (For 03 panels) | 6 | Job per Month | - | - |
| 6 | All as per Sl Item No 3 above, but 175 kVAr. (For 02 panel) | 6 | Job per Month | - | - |
| 7 | All as per Sl Item No 3 above, but 185 kVAr. (For 01 panel) | 6 | Job per Month | - | - |
| 8 | All as per Sl Item No 3 above, but 200 kVAr. (For 06 panels) | 6 | Job per Month | - | - |
| - | All as per Sl Item No 3 above, but 225 kVAr. (For 03 panels) | 6 | Job per Month | - | - |
| - | All as per Sl Item No 3 above, but 250 kVAr. (For 09 panels) | 6 | Job per Month | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
BOQ_871778.xls
BOQ • 0.29 MB
8446HT.pdf
Tender Documents • 0.61 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .