| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC 150 BC LINE MALL ROAD MEERUT CANTT 250001 | MEERUT | UTTAR PRADESH | 250001 | L1 | Accepted-AOC BEING 1ST LOWEST | |
| 2 | L2₹6.8 L+₹95,190 (16.2%)Rejected-Finance C O 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance being not a lowest | |
| 3 | L3₹6.9 L+₹1.0 L (17.2%)Rejected-Finance 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance being not a lowest | |
| 4 | L4₹8.0 L+₹2.1 L (35.6%)Rejected-Finance JAI DURGA CONSTRUCTION COMPANY SAILI BYEPASS ROAD PATHANKOT PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance being not a lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected due to one time verification of the firm has not uploaded |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
16 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (WEST) PATHANKOT
GE (WEST) PATHANKOT
REPAIR MAINTENANCE OF GEYSERS WATER HEATER AND CONNECTED WORKS UNDER GE (WEST) PATHANKOT
2022_MES_551744_1
GE/PKT-37/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (WEST) PATHANKOT
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE (WEST) PATHANKOT
₹16,000
Yes
24 Nov 2022
13 Sept 2022
18 Oct 2022
13 Sept 2022
16 Oct 2022
3 Oct 2022
14 Sept 2022 - 24 Sept 2022
Amount
S&F in replacement heating element triangle/cup type / thread type1.5 KW & testing of electric connections, suitable for any make of Geyser, as per sample complete all as specified and directed by Engineer-in-Charge.
S&F in replacement heating element triangle/cup type / thread type 2 KW & testing of electric connections,suitable for any make of Geyser,as per sample complete all as specified and directed by Engineer-in-Charge.
S&F in replacement PVC flexible copper cable sheathed 3 core, 1.5 Sqmm, universal colour code, complete all as specified and directed by Engineer-in-Charge.
S&F thermostate of 25/50 Ltrs capacity, 250 Volts, AC and testing, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement PVC connection of size 15mm dia and 450mm long, superior quality for Geyser, complete with brass adopted for Geyser hot/cold, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement non-return valve (ISI marked) made of brass and suitable for iron pipe of size 15mm, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement socket outlet 2 in 1, 3 Pin, 5 & 15 Amp Flush type, complete all as specified and directed.
S&F in replacement plug top of 15 Amps, complete all as specified and directed.
S&F socket outlet for metal clad box 20 Amps, complete all as specified and directed.
S&F in replacement metal clad plug top 20 Amps, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement syphon assembly complete for 25 Ltrs capacity Geyser, 6/ 9 hole complete all as specified and directed by Engineer-in-Charge.
All as per srl item No. 11.00 here-in-before but of capacity 50 Ltrs.
S&F in replacement in replacement indicator lamps to Geyser of any make, type & capacity, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement in replacement inner tank of Geyser of capacity 25 Ltrs of suitable size, made of steel as per existing gauge, complete all as specified and directed by Engineer-in-Charge.
All as per srl item No.14.00 here-in-before but capacity 50 Ltrs.
S&F in replacement 15mm bore vent pipe of GI medium grade, complete with fitting of Geyser, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement single pole sheet metal plug and socket enclosure with 3 Pin and earthing arrangement, complete with one single pole MCB of capacity 20 Amps, 240 volts, complete all as specified and directed.
S&F in replacement MCB single pole of capacity 20 Amps, 240 volts, complete all as specified and directed.
S&F in replacement connection cover plates with matching colour of Geyser 25/50 Ltrs, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement outer cover of Geyser capacity 25 Ltrs, complete all as specified and directed by Engineer-in-Charge. Make :- Gilco / Orision / Ditz
All as per srl item No. 20.00 above but 50 Ltrs capacity.
S&F in replacement in replacement GI Nipple of size 15mm bore, medium grade complete all as specified and directed.
S&F in replacement in replacement GI elbow of size 15mm bore, medium grade complete all as specified and directed.
S&F in replacement in replacement GI socket of size 15mm bore, medium grade complete all as specified and directed.
S&F in replacement in repair pressure release valve of geyser (ISI Marked) of 15mm dia with rubber washer, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement in repair Seafty plug of geyser (ISI Marked) of 15mm dia with rubber washer, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement 15mm dia bib cock, chromium plated, cast copper alloy, screw down high pressure long nosewith crutch or butterfly handle, complete all as specified and directed.
S&F in replacement Hot Water tank for solar water heater capacity 1000 litrs made of MS Sheet as per existing size , thickness and design complete all as specified and directed by Engineer-in-Charge.
S&F in replacement heating element of capacity 3KW, Single phase, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement evacuated tubes in collector as per existing size, complete all as specified and directed. Make of solar :- Intersolar / Sharp
S&F in replacement in replacement Micronics spun of existing size and type of 50 Ltrs capacity RO, complete all as specified and directed by Engineer-in-Charge. Make :- KENT / RENUKA WATER TECH / EUERKA FORBES
S&F in replacement of Antiscalent cartridge as per existing size of 50 Ltrs capacity RO, complete all as specified and directed by Engineer-in-Charge. Make :- KENT / RENUKA WATER TECH / EUERKA FORBES
S&F in replacement of Mineral cartridge as per existing size of 50 Ltrs capacity RO, complete all as specified and directed by Engineer-in-Charge. Make :- KENT / RENUKA WATER TECH / EUERKA FORBES
S&F in replacement of inline sediment filter with new as per existing size of 50 Ltrs capacity RO, complete all as specified and directed by Engineer-in-Charge. Make :- KENT / RENUKA WATER TECH / EUERKA FORBES
S&F in replacement of inline Pre-Carbon filter with new as per existing size of 50 Ltrs capacity RO, complete all as specified and directed by Engineer-in-Charge. Make :- KENT / RENUKA WATER TECH / EUERKA FORBES
S&F in replacement of inline Post-Carbon filter with new as per existing size of 50 Ltrs capacity RO, complete all as specified and directed by Engineer-in-Charge. Make :- KENT / RENUKA WATER TECH / EUERKA FORBES
S&F in replacement U.F Membrane as per existing size of 50 Ltrs capacity RO, complete all as specified and directed by Engineer-in-Charge. Make :- KENT / RENUKA WATER TECH / EUERKA FORBES
S&F in replacement Micronic Membrane as per existing size of 50 Ltrs capacity RO, complete all as specified and directed by Engineer-in-Charge. Make :- KENT / RENUKA WATER TECH / EUERKA FORBES
S&F in replacement of flow restrictor with new as per existing size of 50 Ltrs capacity RO, complete all as specified and directed by Engineer-in-Charge. Make :- KENT / RENUKA WATER TECH / EUERKA FORBES
S&F in replacement of TDS adjuster with new as per existing size of 50 Ltrs capacity RO, complete all as specified and directed by Engineer-in-Charge. Make :- KENT / RENUKA WATER TECH / EUERKA FORBES
S&F in replacement of PVC pipe 1/4 with new pipe of 50 Ltrs capacity RO, complete all as specified and directed by Engineer-in-Charge. Make :- KENT / RENUKA WATER TECH / EUERKA FORBES
S&F in replacement of water booster pump as per existing size of 50 Ltrs capacity RO, complete all as specified and directed by Engineer-in-Charge. Make :- KENT / RENUKA WATER TECH / EUERKA FORBES
S&F in replacement of adaptor 230V, AC, 50 HZ, Output 48 volts DC of 50 Ltrs capacity RO, complete all as specified and directed by Engineer-in-Charge. Make :- KENT / RENUKA WATER TECH / EUERKA FORBES
S&F in replacement of UV System of 50 Ltrs capacity RO, complete all as specified and directed by Engineer-in-Charge. Make :- KENT / RENUKA WATER TECH / EUERKA FORBES
Notes :- (a) The contract sum shall be arrived at after deduction of amount of Schedule of Credit. (Rs. 42,388.50). (b) PERFORMANCE SECURITY :- (Refer condition 19 of IAFW-2249) The performance security for an amount equivalent to 3% (Three percent) of the accepted contract sum shall be delivered by the successful bidder immediately after the date of intimation letter of acceptance and all provisions shall be applicable as per condition 19 of IAFW 2249
VAISHNAVI BUILDERS
malghotra construction co
JAI DURGA CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .