Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.3 LAdmitted-Finance | -4.10% | ₹2.3 L | L1 | Admitted-Finance |
| 2 | L2₹2.4 LAdmitted-Finance | +0.01% | ₹2.4 L | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical Others-Non Responsive due to not uploaded registration certificate and any permission & MDRISL Fees not received |
Tender Value
₹2.4 L
EMD Value
₹4,800
Closing Date
23 Jun 2026, 6:00 pmClosed
EXECUTIVE ENGINEER
THE EXECUTIVE ENGINEER P.W.D. ELECT. DIVISION, SEC
SITC of Air Conditioner in Sugam center at Rajasthan Secretariat Jaipur.
2026_CEPWD_568701_2
EESectt_nit_10_26-27
Open Tender
Electrical Works
60 days
Electric work/EESECTT
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
EESECTT/MDRISL
₹4,800
Yes
THE EXECUTIVE ENGINEER P.W.D. ELECT. DIVISION, SEC
29 Jun 2026
17 Jun 2026
24 Jun 2026
17 Jun 2026
23 Jun 2026
17 Jun 2026
22 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply , Installation, Testing and Commissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. Min 5 year Original Equipment Manufacturer (OEM) warranty of both compressor and Printed Circuit Board (PCB). | |||||
| 1.1 | Cooling capacity 5000-5300 Watt, ISEER not less then 3.8 | - | Each | - | - |
| 1.2 | Cooling capacity 6100- 6300 Watt, ISEER not less then 4.6 | - | Each | - | - |
| 2Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. | |||||
| 2.1 | 20 mm | - | mtr | - | - |
| 3Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. | |||||
| 3.1 | Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia | - | - | - | - |
| 3.2 | 100 mm dia per running inch length | - | per inch | - | - |
| 4 | GST | 1 | GST | 36,591.48 | ₹36,591.48 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.94 MB
Tendernotice_2.pdf
PDF • 0.14 MB
Tendernotice_3.pdf
PDF • 1.46 MB
Tendernotice_4.pdf
PDF • 0.61 MB
Tendernotice_5.pdf
PDF • 0.39 MB
BOQ_1011722.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid