Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹41.8 L+₹3.8 L (9.99%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹48.3 L+₹10.3 L (27.1%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 |
Tender Value
₹44.5 L
EMD Value
₹89,100
Closing Date
22 Aug 2020, 6:00 pmClosed
CWE AF SOUTH BANGALORE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
SPECIAL REPAIRS TO MES INSTALLATION AT SOUTH CAMP (PUMP HOUSE NO. 2) AT ATS BELAGAVI
2020_MES_364075_1
81166
Open Tender
Civil Works
Item Rate
180 days
Sambra Belagavi
As per Tender documents
7 documents required · 7 mandatory
₹500
GE (AF) SAMBRA
₹89,100
Yes
12 Nov 2020
25 Jul 2020
25 Aug 2020
25 Jul 2020
22 Aug 2020
10 Aug 2020
25 Jul 2020 - 6 Aug 2020
Amount
Taking up or down 15 mm bore GI tubing including connections all as directed.
Taking up or down 20 mm bore GI tubing including connections all as directed.
Taking up or down 25 to 32 mm bore GI tubing including connections all as directed.
Re- fixing old steel GI tubing 15 mm dia bore in new or old position obtained from Item No. 1 here in before all as directed.
Re -fixing old steel GI tubing 20 mm dia bore in new or old position obtained from Item No.2 here in before all as directed.
Re- fixing old steel GI tubing 25 to 32mm dia bore in new or old position obtained from Item No.3 here in before all as directed.
S & F 15 mm bore GI pipe, medium grade with all fittings fixed complete to walls and ceiling or laid in floors, all as specified and directed.
S & F 20 mm bore GI pipe, medium grade with all fittings fixed complete to walls and ceiling or laid in floors, all as specified and directed.
S & F 25 mm bore GI pipe, medium grade with all fittings fixed complete to walls and ceiling or laid in floors, all asspecified and directed.
Disconnecting existing tanks exc 250 but not exc 500 ltr capacity, setting aside (or lowering if required) for repairs, cleaning etc and hosting if required, reconecting & refixing in position.
S & F in repairs 25 mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed min weight 142 gms.
S & F in repairs 20 mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed minimum weight 142 gms.
Demolition of plain cement concrete/cement concrete tiles of any description and in any position as in roof.
Taking down existing tar felt carefully all as directed by Engr-in-Charge.
M & L Cleaning existing roof surfaces and brushing with neat cement slurry @ 3Kg/Sqm. smooth the surface all as specified and directed.
Rendering in cm (1:3) 10mm thick mixed with conplast-X 42 11 C fosroc Chemical (India) Ltd @100 ml per bag of cement all as per manufacturers instuctions on concrete surface and making the surface and even as in required slope for draining out the rain water all as directed/specified. (Conplast-X 42 11C of FOSROC chemical shall be measured and paid seprately).
Supply only conplast-X 42 11C FOSROC chemical India Ltd. (@100 ml per bag of cement).
M & L Average 50 mm thick Cement concrete type C1, 1:3:6 mix (using 20mm graded stone aggregates), as in padding concrete/levelling course all as specified and directed.
M & L Preparing RCC roof slab by removing dust, dirt and applying oil bond bituminous primer @ 0.2Kg/Sqm and providing APP modified water proofing membrane weighting not less than 4 Kg/Sqm reinforced with non woven polyester matt weighing not less than 160 gms/sqm including minimum 10cm side over laps and 15cm end lap torch sealed and bonded as per detailed procedure on note No. 6 of TD AFB/TD/260/06 sheet 1/1 and applying a coat of blown hot bitumen 95/15 over a membrane at 1.20 kgs/sqm all as per detailed specification and procedure after drying apply a coat of solar reflective bituminous aluminium paint over membrane at 0.10 kg/sqm all as specified and as directed. Note:- (i) The work shall be carried out only through manufacturer or their authorised applicator and a written guarantee for work shall be submitted by the manufacturer for the effectiveness of WPT.
M & L cement concrete 1:2:4, type B1 using 20 mm graded stone aggregate as in parapets, copings, bed plates etc, complete all as specified and directed.
Cutting/chipping the spalling concrete surfaces of columns, beams, cantilever etc and trimming & cleaning the surface to receive guniting/plastering all as specified and directed including all necessary form work & scaffolding upto 25.00m of height and safety measures and lowering down the demolished materials for disposal and disposing the demolition material out MD land.
Providing pressure guniting averaging 15mm thick cement mortar 1:3 for soffits of slabs, chajjas etc complete all as specified and directed including providing double scaffolding as required upto 25.00m of height and removal of the same on completion of the work complete all as required and directed and applying Epoxy Treatment (Nito Bond AR of M/s Fosroc or its equivalent in M/s Dr. Fixit prior to guniting to fecilitate proper bonding with old surfaces complete all as specified and as directed.
Providing pressure guniting averaging 30mm thick cement mortar 1:3 for columns/beams/fins/parapets complete all as specified and directed including providing double scaffolding as required and removal of the same on completion of the work complete all as required and directed and applying Epoxy Treatment (Nito Bond AR of M/s Fosroc or its equivalent in M/s Dr. Fixit prior to guniting to fecilitate proper bonding with old surfaces upto 25.00m of height complete all as specified and as directed
Welded steel wire fabric supplied and fixed complete steel members weight per sqm n exc 4 kg fixed to existing reinforcement all as directed by engg in charge as under upto 25m height.
Welding additional reinforcement with the existing rods mild steel TMT bars 6 to 8 mm dia cut to length bent to shape required including cranking bending spirally hooking ends etc upto 25.00m of height (welding shall be measured separately).
Welding additional reinforcement with the existing rods mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally hooking ends etc upto 25.00m of height (welding shall be measured separately)
M & L for injection grout using M/s FOSROC or STP or equivalent materials all as per manufacturer instruction utpo height of 25.00m complete all as specified and directed.
Dismantling RCC posts or struts ( steel , RCC) any section including taking down embedded portion and making good as disturbed ground all as specified
Excavating in post holes (or similar holes) each n exc 0.05 cum, getting out , returning, lilling in and ramming earth or broken rubble mixed with around in layers not exc 25cm in hard dense soil.
S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron sinets (for secnring wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire all as specified and directed.
Supplying only Chain Link MS galvanised fencing any size or type all as specified and directed.
S&f of mild steel screw bolts with hexagonal or square heads at one end and screwed the other, or screwed both ends of dia 5 to 10 mm with washers and one hexagonal or square exc 5cm but n.exc 10 cm long all as specified and directed.
M&L for preparation of new surfaces of steel of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
Surface Excavation n. exc. 30cm deep & avg 15 cm deep & getting out in hard dense soil all as specified and directed.
M/L fo hardcore of gauge n. exe 63 mm deposited spread, levelled in layers n. exe 15 cm thick, watered rammed to a true surface.
M/L PCC 1:4:8 type D2 using 20 mm graded stone agg 75 mm thick as in paving all as specified and directed.
M/L for screed bed or bedding layer of mortar 15 mm thick for laying floor finish in CM (1:6) all as specified and directed.
M/L designer rubber moulded cement concrete tiles of approved colour and pattern of size 200 x 200 x 25 mm / 300 x 300 x 25 mm tiles with grey cement and pigment thick set and jointed and pointed in neat cement slurry all as specified and directed.
Excavating in trenches n exc 1.5 m wide and n exc 1.5 m depth for foundation etc or for shafts, wells cesspits, manholes, pier holes etc n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard/dense soil.
M/L cement concrete in foundation filling and mass concrete type D-2 1:4:8 (40 mm graded stone aggregate) all as specified and directed.
M & L for pre cast cement concrete block masonry grade 'C' solid blocks exc 10cm in width having minimum compressive strength of 50 kg/sq cm as per IS 2185 (Part I) 2005 and set in cement mortar 1:4 complete all as specified.
M/L for Cement concrete type B-1 1:2:4 (20 mm graded aggregate) as in surface channels and drains complete all as specified.
M & L for rendering 15 mm thick in CM 1:4 on fair surfaces of block masonry/concrete surfaces finished even and smooth without using extra cement all as specified and directed.
Returning filling in including spreading levelling and well ramming in layers not exc 25 cm in hard soil all as specified and directed.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed of hard soil all as specified and directed.
M & L for extra for forming fair finished drain or channel 45 cm inner girth in cement concrete, using extra cement, including forms, moulds etc all as specified and directed.
M & L providing precast cement concrete types B1 1:2:4 (20mm graded aggregate) in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:6 complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonary, build in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but all as specified.
Removal of honey bee hives carefully at different locations and including applying of chemical over affected portion of the hives upto height of 10.0m complete all as specified and directed.
Removal of honey bee hives carefully at different locations and including applying of chemical over affected portion of the hives above height of 10.0m and upto 25.0m complete all as specified and directed.
Taking down cement plaster including racking out joint hacking for key scrubbing down with water etc.
Material and labour 5 mm thick cement plaster in CM 1:3 for ceiling finished even & smooth without using extra cement on concrete surfaces.
M & L Rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces finished fair and even and smooth with out using extra cement.
M & L for new surface of ceiling by scrapping wand washing including perpration of surface by applying three coat of white washing all as specified and directed.
Two coats of Cement base paint over a coat of primer on walls, pillasters, cornices, etc, on newly plastered walls including preparation of surfaces all as specified and as directed.
Preparation of newly plastered surfaces and applying two coats acrylic distempering over a coat of primer on walls, pillasters, cornices, etc all as specified and as directed.
One coat of white wash on old decorated surfaces of ceilings including necessary preparation of surfaces all as specified and as directed.
One coat of Acrylic distemper on old distempered walls, pillasters, cornices, etc., including necessary preparation of surface by washing, rubbing down and stopping all as specified and as directed.
One coat of cement base paint on old cement painted walls, pillasters, cornices, etc., including necessary preparation of surface by washing, rubbing down and stopping all as specified and as directed.
One coat of weather proof exterior emulsion on old decorated surfaces of walls, pillasters, roof projections, facias, drops, chajjas, etc., including necessary preparation of surface by washing, rubbing down and stopping all as specified and as directed.
M&L preparation of old plastered surfaces of walls by brooming down or steel wire brusing; scrapping down smoke soot, moulds, moss and effloroscent salts and tradingoil and greasy spots and applying two coats of anti fungal paint over a coat of primer upto 25.00m height including removal of existing finishes complete all as specified and directed including taking down of existing finishes.
One coat of synthetic enamel paint on old painted wooden surfaces of any description over 10cm width or girth including necessary preparation of surface all as specified and as directed.
One coat of synthetic enamel paint on old painted steel surfaces of any description over 10cm width or girth including necessary preparation of surface of overhead tank of 18m staging all as specified and as directed .
One coat of synthetic enamel paint on old painted steel surfaces of any description over not exc 10cm width or girth including necessary preparation of surface all as specified and as directed.
Material and labour for two coats of synthetic enemal paint over a coat of red oxide on new steel surface including preparation of surface complete all as specified and directed.
Material and Labour Surfaces of any description, n.exc 10cm in width or girth two coats of synthetic enamel apint over a coat red oxide on new steel surfaces when unconnected with other painting or when painted in a different tint all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15cm thickness (below or above G.L) all as specified and directed.
Dismantling of Wall/floor heatrth or wall tiling including cement mortar bedding(but not backing coat)and removing rubbish off the premises all as specified and directed.
M & L 75 mm thick cement concrete type C1, 1:3:6 (using 20 mm graded crushed stone aggregate), as in plinth protection.
M & L for dark coloured Non skid coloured tiles superior finish grade B-1 quality 7 to 8 mm thick(square/ rectangular) area of each tiles exceeding 0.11 sqm but not exc 0.18 sqm in floor with rectified edges ( joint free) etc set and jointed in neat cement slury over cement screed 15 mm thick 1:6 all as specified and directed.
M & L for Coloured glazed ceramic tiles economy finish Gde B-II (b) quality of size 300 x 450 x 7 mm thick with rectified edges as in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and incl 10 cm thick backing with cm 1:4 all as specified and directed..
Dismantling wrough iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr- in- charge.
Supply and fixing roof trusses (framed), trussed, purlins, cranes gantries, rails nd fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 290 (Gde E-165) complete all as specified and directed.
S&F hand rails, half round or other steel section or core for steel/wooden hand rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc, wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed drilling, holes, notching for wire etc , flat iron fillets (for securing wire mesh etc including all necessary drilling , bolting or riveting etc and similar work conforming to fe-290 gde E-165 complete all as specified and as directed Overhead tank of 18m staging .
S & F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment (Fe-290, GdeE-165) complete all as specified and directed.
Taking down chowkhats or frame n. exc 1.5 sqm with shuttter ( without taking off shutter from the frames) all as specified and directed.
Material and labour welding in repairs n exc 2.5 cm in length and not exc 6mm thick of metal to be welded all as specified and directed.
Supply and fix steel ventilator with top hung shutter including hinges steel peg stay complete all as specified and directed.
Supply and fix steel windows with side hung shutters including projecting type hinges with steel handles and steel peg stay complete with glazing bars devetailed or welded all as specified and directed.
Supply and fix 4 mm thick figured glass pin head type and glazing with oil putty in square n. exc 0.5 sqm in each pane
M & L 4 mm thick sheet glass, ordinary quality and glazing with oil putty with glazing clips or wooden beading not exc 0.5 Sqm in each pane all as specified and directed.
Demolition of reinforced cement concrete, in suspended slabs, beams, lintels, etc in cement mortar or cement concrete (reinforcement out as required to facilitate demolition) all as specified and directed.
Use and waste formwork to soffits of suspended slab such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick for fair finished surfaces (horizontal / sloping or curved) complete all as specified and directed.
Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to complete all as specified and as directed.
S & F mild steel TMT bar 6 to 8 mm dia as in stirrups cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
M & L reinforced cement concrete (nominal mix) type B1 1:2:4 (20 mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, deck slabs and in shelves and the like complete all as specified and directed.
Removal of concrete and plaster debris to a distance exceeding 1.5KM but not exceeding 5.00KM and depositing where directed complete all as directed.
E & M Works: Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified and directed.
Taking down carefully unserviceable main switches/DB's off size incl MCBs from their position and removing materials from site all as specified and as directed by Engr-in-Charge
Taking down existing sub main wiring with aluminum conductor cable of 2 of 4/6/10 sqmm with GI earth wire on and including wooden batten and removing materials from the site and making good distrubed surface of walls and ceiling complete all as specified and as directed by Engr-in-Charge
Material and Labour for point wiring with PVC unsheathed multi standard 1.5 Sqmm FRLS copper Cable for one light point controlled by one way switch, and wire to be drawn in and including PVC casing capping 20/25 mm width complete with all accessories including MS sheet metal 1.6 mm thick switch board or PVC rectangular switch board of suitable size with 3 mm thick plastic laminated sheet cover for fixing switch / socket / regulators etc fixed on wall respectively including making good disturbed surfaces and white washing/colour washing / distembering to match the existing surfaces including PVC unsheathed multi standard 1.5 Sqmm FRLS copper cable as earth continuvity connected with common earth dolly complete all as directed by Eng -in Charge for :-
(a) One light point controlled by one 1 way switch 5 Amp complete
(b) One fan point controlled by one, 1 way switch 5 Amp complete
(c) One 3 pin socket outlet 5 amp independent
(d) One 3 pin sockt outlet 5 Amp on the same board with other switch
All as per srl item No 4 above but for one 3 pin socket outlet 15 Amp independent with cable of size 2.5 Sqmm for piont wiring and 2.5 sqmm as in contineous earth wire all as specified and directed.
M&L complete for switch piano flush button single pole one way 5 Amp 240 Volts all as specified and directed.
M&L for swith socket combination 2 in 1,3 pin 5 Amp flush type 240 volts complete all as specified and directed.
M&L for swith socket combination 2 in 1,3 pin 16 Amp flush type 240 volts complete all as specified
M&L complete for ceiling rose surface backelite three terminal 240 volts complete all as specified
S&F fan regulator, electronic, step type, flush mounting complete all as specified and as directed.
Taking down old US tube light fitting & M&L for LED batten T8 LED Lighting fixture with CRCA batten complete with retrofit T8 polycarbonate ready to use 20 watt C&S Make- Code-LTDC01220WLED/WD ,fitting fixing on wall/on roof/truss etc. complete all as specified and as directed or equivalent make of /Crompton reaves/Wipro/Havells/Philips/surya .
Supply and fixing of street light fitting LED 45 watt with fixing arrangement such as 40 mm bore light grade GI pipe bracket of 1.20 Mtr long, MS clamp, Nut bolts etc and connecting up as specified and directed. Make : Havells, Model No ENDURAPEARNEOSL45WLED757SASYTOPC or equivalent make of Bajaj/Crompton/Philips
Sub main wiring with four single core stranded copper conductor unsheathed PVC insulated FRLS cable 1100V grade with 2.5 sq mm drawn through suitable size of non-metallic PVC rigid conduit/casing caping with Two run 2.5sqmm copper conductor FRLS cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up complete all as specified and directed. NOTE ;- Four runs of 6 sq mm cable and two run of 2.5 sq mm neutral & earth continuity copper conductor and one run of PVC conduit / casing caping shall be measured as one unit
Sub main wiring with two single core stranded copper conductor unsheathed PVC insulated FRLS cable 1100V grade with 4 sq mm drawn through suitable size of non-metallic PVC rigid conduit/casing caping with one run4 sqmm copper conductor FRLS cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up complete all as specified and directed. NOTE ;- Two runs of 4 sq mm cable and one run of 4 sq mm earth continuity copper conductor and one run of PVC conduit / casing caping shall be measured as one unit
S&F and connecting up complete for MCB DB SPN 4 way Horizantal ,double door,240 V AC , 50 Hz, with for MCB as incomer and TP//DP/SP MCBs as outgoing, IP-42 protection confirming to IS- 13032 universal mounting with copper bus bar , neutral link, earth link, earthing sluds, detachable gland plates with knockout on both sidescomplete all as specified and as directed.
M&L complete for MCB SP 06 to 32 Amps 240 volts, 50 Hz AC supply complete all as specified
M& L complete for MCB SPN 32 Amps, 240 Volts, 50 Hz AC supply complete all as specified
M/L for complete earthing with galvanised mild steel earth plate electrode of size 600x600x6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4 mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised ironl including PCC pit in PCC 1:3:6 type C-1, RCC cover slab with PCC 1:2:4, using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20 mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh and 15mm dia bore light grade galvanised steel tubing upto 7.5 m length for protection of earth lead wire , common salt, charcoal etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion.
Shifting of BER DG set of capacity 35 KVA by taking out from existing foundation including disconnecting all incoming/outgoing cables earth strips complete with fuel tank,AMF Panel & DG panel from pump house no 2 to MES store yard with out disturbing existing electric supply and electric connection by using crane all as specified and directed by Engr -in -Charge.
M&L for relocating existing LT Panel & AMF Panel of 125 KVA DG set from its existing position to another position incl earth strips, incoming and out going LT cable and electric connections and making new foundations of suitable size complete all as specified and directed by Engr -in -Charge.
M & L for taking out and relaying and saddling of existing LT cable of off sizes by using suitable size of saddle at a distance not more than 45 cm or all specified by Engr-in-Charge.
M&L earth continuity conductor or main earthing lead fixed to wall on porocelain insulator of size 25x4 mm galvanized iron strip.
M&L for relocating existing electronic/digital water level indicators-02 nos from its position to another position incl provision of casing capping inside the bldg incl suitable size for incoming and outgoing cable of suitable size. Complete all as specified and directed by Engr -in -Charge.
S& F sluice valve cast iron sluice valve of class PN-1 with both end flanged confirming to the IS -14846 with stainless steel spindle and iron wheel head including new rubber gasket ,bolts and nuts etc including dismantling of existing unserviceable valve of size 200 mm.
S & F unplastic PVC pipe of 40 mm in floor or wall for cable protection .
M/S MAHADEV M PATIL
M/S SANJAY B SHARMA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .