Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹26.5 L+₹2.7 L (11.2%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹26.5 L+₹2.7 L (11.3%)Rejected-AOC COLABA MUMBAI | L3 | Rejected-AOC Rejected | |
| 4 | L4₹26.8 L+₹3.0 L (12.5%)Rejected-AOC COLABA MUMBAI | YAVATMAL | MAHARASHTRA | 445001 | L4 | Rejected-AOC Rejected | |
| 5 | Rejected-Technical | - | Rejected-Technical Due to MOU not submitted as required as per Sch A Notes given on clause No 18 of tender |
Tender Value
Refer Docs
EMD Value
₹48,400
Closing Date
20 Apr 2023, 6:00 pmClosed
CWE KARANJA
CWE KARANJA NAVAL STATION KARANJA URAN RAIGAD - 400704
SPECIAL REPAIRS TO 01 NO 08 PASSENGER LIFT INSTALLED AT NAVAL STATION KARANJA
2023_MES_584363_2
84213-K/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
NAVAL STATION KARANJA
Please refer tender documents
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER (NW) KARANJA
₹48,400
1 May 2023
25 Mar 2023
22 Apr 2023
25 Mar 2023
20 Apr 2023
8 Apr 2023
Amount
Dismantling and taking out old control panel and supply and fixing new control panel complete with all safety such as over load, over current protection incl proper connection with existing circuit with proper lugs, terminal connector screws and motor connection with size of standard copper cable single core etc complete for 8 passenger lift to serve G+10 floors Kailash building complete all as specified and as directed by Engr-in- Charge.
Removing and refixing of lift car counter weight and alignment of rails in shaft wall properly grouting in rich concrete mix and large size fasteners with chemical bolt for fixing the fastener brackets (recommended product- Hill and fisher make) for 8 passenger lift to serve G+10 floor installed at Kailash building complete all as specified and as directed by Engr-in- Charge.
Disconnecting and taking out unserviceable shaft wiring and providing new shaft wiring in hoist way up to lower limit switch with PVC insulated single core multi stranded copper conductor cable 0.75 sqmm and 1.5 sqmm for earthing and 6.0 sqmm single core for motor, 1100 volts grade, drawing through in galvanized sheet metal (24G) trunking from machine room to serve ground plus 10 floor in hoist way for control of all floor hall push button assembly limit switch, fireman switch complete suitable for 08 passenger lift to serve G+10 floor installed at Kailash building complete all as specified and as directed by Engr-in- Charge.
Disconnecting and taking out unserviceable COP assembly for G+10 floors and supply and fixing new car operating panel Assembly complete with illuminated push button for floor position, alarm, non-stop door open, door close, cabin fan, cabin light stop, attend out key etc., with direction indicator with LCD/ LED display with CPI card and 2mm thick stainless steel face plate complete suitable for 8 passenger lift to serve G+10 floor installed at Kailash building complete all as specified and as directed by Engr-in- Charge.
Dismantling and taking out unserviceable existing door, its mechanism and supply and fixing complete landing door mechanism, center opening type, with new stainless steel hair line finish door panels, side guards, jamb channels etc for 800 mm clear opening and replacement of existing door plywood 8mm thick with water proof and rust free stainless steel door suitable for 8 passenger lift to serve G+10 floor installed Kailash buildings complete all as specified and as directed by Engr-in- Charge.
Dismantling existing unserviceable VVVF drive and supply, fixing, commission and testing variable voltage variable frequency (VVVF) drive, close loop with PGB2 card with multiple micro program chips based link each other in network, thermal over load protection, compatible to new encoder at motor etc of make Yashikawa Japan,11 KW capacity, suitable for 8 Passenger lift to serve G+10 floor installed at Kailash building complete all as specified and as directed by Engr-in- Charge.
Disconnecting and taking out of existing car cabin with new car cabin for 8 persons/ 544 kg passenger lift made of 1.5 mm thick stainless steel hair line finish side enclosures assembled on 3mm thick sheet metal platform, covered with 3mm thick aluminium chequered plate, false ceiling made of 1.2mm thick stainless steel hair line finish sheet, with LED spot lights for lighting, including cabin fan non oscillating type including necessary wiring of controls complete with display safety instruction (engraved on plate) such as DOs /DONTs., toed capacity, safety barricade on car top, toe guard at bottom in and including safety features i.e., emergency lighting system, alarm, door interlocks, final limit switch, levelling device, handrail, flow control valve, stack/ broken cable device, car door contact, infrared light curtain etc over load sensing switches at platform etc suitable for 08 passenger lift to serve G+10 floor installed at Kailash building complete all as specified and as directed by Engr-in- Charge.
Dismantling and taking out unserviceable car door from car cabin supplying and fixing new car door comprise of 02 No VVVF controlled, power operated, center opening by horizontal sliding stainless steel panel 1.2 mm thick hair line finish flush type panels complete with interlock switches, safety edge with full beam, infra red sensor up to full length of car door, aluminium sill, complete with control connection etc suitable for 08 passenger lift to serve G+10 floor installed at Kailash buildings complete all as specified and as directed by Engr-in- Charge.
Dismantling and taking out of lift main pully, supplying and fixing new main pulley suitable for 08 passenger lift to serve G+10 floor at Kailash building complete all as specified and as directed by Engr-in- Charge.
Dismantling and taking out of lift governor and pit pulley set, supplying and fixing new governor and pit pulley set suitable for 08 passenger lift to serve G+10 floor at Kailash building complete all as specified and as directed by Engr-in- Charge.
Dismantling of existing Automatic Rescue Devices (ARD) and supply and fixing ARD system including replacement of microprocessor card, IGBT card, control wires etc including testing suitable for 8 passenger lift to serve G+10 floor installed at Kailash building complete all as specified and as directed by Engr-in- Charge.
Material and labour for repair to main drive gear assembly comprising following complete all as specified and as directed by Engr-in-Charge. (i) Disconnecting and dismantling from installed position, loading/ unloading and transporting to nearest workshop. (ii) Repair/ replacement of worn out gear assembly suitable as per existing. (iii) Repalcement of both side ball bearing with existing size and make SKF. (iv) Replacement of both side oil seals and gear oil of approved make. (v) Replacement of break shoe and liner where required complete.
Disconnecting and taking out of old unserviceable steel wire rope after necessary disconnecting in hoist way from counter weight, pulley and car cabin, supply and fixing steel wire rope 13 mm dia heavy duty confirming to relevant IS standards un galvanized 8/19 construction suitable for lift including necessary proper connection suitable for 8 passenger lift to serve G+10 floor installed at Kailash buildings complete all as specified and as directed by Engr-in- Charge.
Disconnecting and taking out of old unserviceable steel wire rope after necessary disconnecting from over speed governor supplying and fixing steel wire rope 08mm dia heavy duty confirming to relevant IS standards un galvanized 8/19 construction suitable for lift including necessary proper connection suitable for 8 passenger lift to serve G+10 floor installed at Kailash buildings complete all as specified and as directed by Engr-in- Charge.
Disconnecting and taking out of unserviceable travelling cable from hoist way, supplying and fixing new travelling cable PVC insulated 12 core with standard copper conductor, 1100 volts grade of size 0.75 sqmm conforming to relevant IS specification including thimbles, suspended freely move with car cabin up and down movement between ground and upper floors including necessary proper connecting with the way junction and other connection required in existing circuit suitable for 8 passenger lift to serve G+10 floor installed at Kailash building complete all as specified and as directed by Engr-in- Charge.
Disconnecting and taking down old existing button and supply and fixing complete new hall push button with steel box having button for call registration and LCD/ LED Indicators having stainless steel 2.0 mm thick face plates complete suitable for 8 passenger lift to serve G+10 floor installed at Kailash buildings complete all as specified and as directed by Engr-in- Charge.
Supply and install floor anouncement system in Hindi, English language with music suitable for all types of control system complete suitable for 8 passenger lift to serve G+10 floor installed at Kailash buildings complete all as specified and as directed by Engr-in- Charge.
Supply and fix for rechargeable maintenance free lead acid batteries of 12V, 17 AH for ARD system complete all as specified and as directed by Engr-in- Charge. General Note: The lift will be inspected by lift inspector of state govt and the fees shall be inclusive of rate quoted above. The Spl repair work will be completed after inspection lift inspector.
Shree Elevator Engineering Co.
Monarch Enterprises
Escon Elevators Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .