Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹71.6 L+₹68,980.28 (0.97%)Rejected-Finance NO 1 116 GANGAI AMMAN KOVIL STREET SORANJERY PATTABIRAM CHENNAI 600072 | CHENNAI | CHENNAI | TAMIL NADU | 600072 | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | L3₹80.8 L+₹9.9 L (13.9%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest tenderer |
Tender Value
₹75.5 L
EMD Value
₹1.4 L
Closing Date
30 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri. Narinder Singh, IDSE, SE(SAG)
COMMANDER WORKS ENGINEERS CHENNAI PALLAVAN SALAI CHENNAI 600 002
87651E8 PROVN OF LIVING SHELTERS AND DEFF ACCN FOR TRAINEES AT MTTI, UNDER GE AVADI CHENNAI
2021_MES_462141_1
87651E8
Open Tender
Civil Works
Item Rate
90 days
AVADI CHENNAI
AS PER NIT
9 documents required · 9 mandatory
₹1,000
GE AVADI CHENNAI
₹1.4 L
Yes
30 Oct 2021
23 Jul 2021
6 Sept 2021
23 Jul 2021
30 Aug 2021
17 Aug 2021
23 Jul 2021 - 31 Jul 2021
60 days
Amount
REVISED BOQ UPLOADED ON 13 AUG 2021, BOQ UPLOADED ON 11 AUG 2021 CANCELLED
SCH "A" PART-I (CIVIL WORKS)
Demolition of brickwork or stone boulder masonry, built in cement mortar, including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles and removal of unserviceable debris to a distance not exceeding 100m complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying cables / pipes etc., or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out in any type of soil all as specified and as directed.
Earthwork is deemed to be carried out by manual method. However mechanised method may be adopted without any extra cost to the government.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in any type of soil complete all as specified and as directed.
Filling under floors using soil spreading and levelling in layers not exceeding 25cm thick and well ramming including watering and consolidation complete all as specified and as directed.
Approved as excavated vide BOQ Sl Item No.4.00 and 5.00 shall be used under this item.
Removing excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Moorum/red bajri filling in floors or in pavings, laid in layers not exceeding 15cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
The cubical measurement shall be after consolidation.
Plain cement concrete, type B1, 1:2:4, using 20mm graded stone aggregate as in bed blocks and the like including weathering, slightly rounded or chamfered angles and throating and necessary formwork complete all as specified and as directed.
Plain cement concrete, type C0, 1:3:6, using 12.50mm graded stone aggregate in filling in door frames and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed.
Plain cement concrete, 1:4:8, type D2, using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
Reinforced cement concrete, RCC M-25, (Design Mix), using 20mm graded stone aggregate as in plinth beam, footing, bases of columns etc., complete all as specified and as directed.
Reinforcement shall be measured and paid separately as applicable.
Reinforced cement concrete, RCC M-25, (Design Mix), using 20mm graded stone aggregate as in columns, pillars etc., complete all as specified and as directed.
Reinforcement shall be measured and paid separately as applicable.
Use and waste of formwork to sides of concrete foundations, plinth beams and similar work; vertical or to batter rough finished surfaces of concrete complete all as specified and as directed.
Use and waste of formwork to sides of columns, pillars, stancions and similar work; square, rectangular or polygonal rough finished surfaces of concrete complete all as specified and as directed.
Factory made Glazed and skeleton shutters, of IInd class hardwood, 30mm thick open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and as directed.
Glass or wire cloth as required shall be measured and paid separately.
Flush shutters, 35mm thick, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
Aluminium anodised barrel tower bolts, of extruded section and fixed, length of bolt 150mm complete all as specified and as directed.
Aluminium anodised barrel tower bolts, of extruded section and fixed, length of bolt 200mm complete all as specified and as directed.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, length of bolt 300mm complete all as specified and as directed.
Butt hinges, medium weight, cold rolled mild steel and fixed / welded to frame of size 100mm complete all as specified and as directed.
Extruded aluminium alloy handles, fabricated type, anodised of size 150mm complete all as specified and as directed.
Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, overall length of cover plate 140mm, including fixing on floor complete all as specified and as directed.
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Mild steel as in small articles such as hold fast, wall ties, bands, straps and like conforming to Fe-290 Grade-E-165 complete all as specified and as directed.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 5cm but not exceeding 10cm and diameter of neck 11mm to 15mm complete all as specified and as directed.
Mild steel bolts purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 300mm long and diameter of neck exceeding 20mm and not exceeding 25mm complete all as specified and as directed.
Mild steel TMT bars 10mm dia & over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in main reinforcement complete all as specified and as directed.
Mild steel TMT bars but 5mm dia and over upto and including 10mm dia, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups, spacers & binders complete all as specified and as directed.
Rolled mild steel as in plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections, of Fe-410-W (Gde E-250 quality A) complete all as specified and as directed.
Rolled mild steel of grade Fe-410-W (Gde-E-250) Quality-A as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, riveted, bolted or welded complete all as specified and as directed.
Rolled mild steel as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces., cleats etc., of Fe-410-W (Gde E-250 quality A) complete all as specified and as directed.
Pressed steel frames for doors of size 105mm x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., tarring and sanding of hidden steel surfaces complete all as specified and as directed.
PCC bed block to fix the frames and PCC filling in pressed steel frame as required shall be measured separately.
Aluminium frame for doors, windows, ventilators with one or more rebates including ioining cleat for fixing etc. powder coated to minimum 50 micron thickness complete all as specified and as directed.
Supply only aluminium window and ventilator shutters, side hung type without sash bar, including anodised aluminium shutter sections and anodised aluminium snap beading, ioining cleats, glazing clips etc., powder coated to minimum 50 micron thickness complete all as specified and as directed.
(a) Rubber packing, screws etc. as required shall be measured fixing of shutters.
(b) Glass or wire cloth as required shall be measured and paid separately.
Fixing only aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary ioining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, and provision of anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21, 100mm long (2 Nos.), suitable handle (1 No.) , aluminum tower bolt 125mm (02 Nos) etc., complete all as specified and as directed.
(a) All aluminium sections including snap beading, joining cleats, glazing cilps etc. shall be measured under aluminium shutters separately as supply only.
(b) Glass or wire cloth as required shall be measured and paid separately.
(c) The fixtures given are for shutter of approximate size 0.50m x 1.50m.
Anodised aluminium grill (anodised transparent or dyed to required shade according to IS-1868 with minimum anodic coating of grade AC 15) of approved design / pattern, with approved standard section and fixed to existing window frame with CP brass / stainless steel screws at 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium section around the opening , complete all as specified and as directed.
Powder coated aluminium snap grid framework (powder coating of minimum 50 microns) of grid size 605mm x 605mm of main and cross tee of size 40mm x 25mm x 1.5mm thick and wall angle size 25mm x 25mm x 1.5mm thick for false ceiling including fixing of supporting hangers complete all as specified and as directed.
The hangers for support of false ceiling shall be measured and paid separately.
Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed.
Gypsum Board 12mm thick of size 600mm x 600mm in ceiling fixed with screw as per manufacturers and surface prepared and applying two coats of distemper oil emulsion white or tinted including in narrow widths, bands, cornices, pilasters etc., over self primed surface complete all as specified and as directed.
Plain, galvanised, mild steel sheeting, 0.63mm thick, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed.
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws of length suitable for wooden and structural members of steel truss or any other suitable method to fix the sheet complete all as specified and as directed.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws of length suitable for wooden and structural members of steel truss or any other suitable method to fix the sheet complete all as specified and as directed.
Plain cement concrete, 1:4:8, type D2, using 40mm graded stone aggregate, 75mm thick as in sub-base to floor complete all as specified and as directed.
Plain cement concrete 40mm thick, type B1, 1:2:4, using 20mm graded stone aggregate,surface finished even and smooth without using extra cement as in floor complete all as specified and as directed.
Glass dividing strips, 3mm thick, width 38mm inserted in position, conform to design complete all as specified and as directed.
Roughening surfaces old concrete floor by picking, sweeping clean and washing down with water to remove dust and brushing neatly with cement slurry with 3 kg of cement slurry per square metre complete all as specified and as directed.
Rendering 15mm thick in CM(1:4) on fair faces of brickwork or concrete surfaces finished even and smooth complete all as specified and as directed.
Preparing newly plastered surfaces of wall, applying two coats of cement paint over a coat of primer including in narrow widths, bands, cornices, pilasters etc., complete all as specified and as directed
Preparing new surfaces of steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Sheet glass, 5mm thick, ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and as directed.
Preparing new surfaces of wood and wood based materials of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Pre-cast cement concrete block masonry with grade 'C' solid blocks exceeding 10cm in width having minimum compressive strength of 50 Kg/Sqcm as per IS 2185 (Part-I) 2005 and set in CM 1:4 complete all as specified and as directed.
PUF (Polyurethane Foam) insulated panels, 60mm thick, of density 40 kg / cum sandwiched between two sheets of 0.50mm thick pre-painted galvanised iron sheet cladding having internal finish of ivory colour and external finish of camouflage pattern and tongue and groove joints at both vertical sides, panels having locking arrangements with check nuts for joining the panels to each other, also having heat transmission co-efficient all as per IS-661-2000 and IS-3792 and panels provided with additional reinforcement in the form of suitable hollow sections vertically and horizontally at suitable intervals complete all as specified and as directed.
Vertical and horzontal reinforcement of hollow sections provided shall be measured and paid separately.
SCH "A" PART-II (INTERNAL ELECTRIFICATION)
Point wiring on stone / brick masonry wall complete with two 1.5 sqmm single core PVC insulated 1100 volts grade unsheathed FRLSH cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia fixed to fabricated sheet wall with suitable clamps and fixing accessories, and including provision of one 1.5 sqmm PVC insulated single core multistranded copper conductor FRLSH green in colour as earth continuity conductor and connected to common earth dolly, including pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet, 60mm deep, concealed in walls, duly painted with two coats of anti-corrosive over a coat of red oxide zinc chrome primer and covered with bakelite hylam sheet cover 3mm thick fixed with cadmium plated screws for housing the switches, socket outlets, fan regulators etc., complete all as specified and as directed for one light point controlled by one switch.
Cost of terminal box is deemed to be included in the item rates quoted for point wiring.
All as per BOQ No.55 here-in-before but for one ceiling fan point controlled by one switch and regulator
Cost of terminal box is deemed to be included in the item rates quoted for point wiring.
All as per BOQ No.55 here-in-before but for One switch socket outlet point 3 pin 5 Amps on independent board.
Cost of terminal box is deemed to be included in the item rates quoted for point wiring.
All as per BOQ No.55 here-in-before but for One switch socket outlet point 3 pin 5 Amps on same board with other switches.
Cost of terminal box is deemed to be included in the item rates quoted for point wiring.
All as per BOQ No.55 here-in-before but for point wiring with two 4.0 sqmm single core copper conductor multistranded FRLSH cable and one 4.0 sqmm PVC insulated single core multistranded cable as earth continuity conductor FRLSH green in colour drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 25 mm dia for one 5 pin switch socket outlet, 5/15 Amps, on independent board complete all as specified and as directed.
Cost of terminal box is deemed to be included in the item rates quoted for point wiring.
Switch piano, flush type single pole, one way, 5 Amps complete all as specified and as directed.
Switch socket combination, flush type, 2 in 1, 3 pin, 5 Amps universal type complete all as specified and as directed.
Switch socket combination, flush type, 2 in 1, 3 pin, 5 Amps and 15 Amps universal type complete all as specified and as directed.
Ceiling rose, 3 terminal, PVC / polycarbonate, insulated body complete as specified and as directed.
Stepped type electronic fan regulator, 300 W, flush type, including fixing on existing laminated sheet complete as specified and as directed.
LED light fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light, pre wired including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire complete all as specified and as directed.
Ceiling fans complete with blades, down rods, without electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and connecting including provision of two way PVC connectors, 1.5 sqmm flexible three core multistranded copper conductor cable from ceiling rose or connector to fan complete all as specified and as directed.
MCB 6-32 Amps, SP, 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
(a) Make shall be Havells Cat No. DHMGCSPF006-032 or equivalent of makes as listed here-in-after.
MCB 40 to 63 Amps, SPN, 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
(a) Make shall be Havells Cat No.DHMGCSNF040-63 or equivalent of makes as listed here-in-after.
MCCB 100 Amps, FP, 415 Volts, 3 phase, 50 Hz, 16 kA breaking capacity, with fixed thermal and fixed magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 75% of Icu having spreader links and barriers as standard feature of manufacturer complete all as specified and as directed.
(a) Make shall be Havells Cat No. IHLGNF0100 # or equivalent of makes as listed here-in-after.
MCB DB SPN 8 way, single door, powder coated, 240 volts, AC, 50Hz, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed.
(a) Make shall be Havells Cat No. DHDMSHODCW08 or equivalent of makes as listed here-in-after.
Load line MCB DB TPN 4 way, vertical, double door, powder coated, 415 volts, AC, 50Hz, fixed on wall semi flush with provision for MCCB FP, 100 Amps as incomer and MCB SP 6-32 Amps as outgoing with tinned copper bus bar, neutral link, earth link, blanking plates and connecting up complete all as specified and as directed.
(a) Make shall be as Havells Cat No. DHDLVDRWGOFO04 under or equivalent of makes as listed here-in-after.
(b) MCCB and MCB as required shall be measured and paid separately.
LED building security light fitting 20W made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07, complete pre-wired and connecting up with suitable twin core flexble copper wire including provision of necessary GI tubing medium grade 25mm bore of pipe 1.5m bent to shape with necessary clamps made out of mild steel, nuts and bolts etc., including two coats of synthetic enamel paint over a coat of red oxide primer on exposed steel surface for fixing the fitting to steel tubular poles etc complete all as specified and as directed.
(a) Make shall be as Havells Cat No. ENDURAPEARLSL20WLED757SASYTOPCMP under or equivalent of makes as listed here-in-after.
(b) For all other mandatory requirements of LED fittings, please refer under Particular Specifications here-in-after.
Power / Sub-main wiring with PVC insulated unsheathed, 1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmm FRLSH conforming to IS-694, drawn through and including suitable dia rigid PVC conduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor cable FRLSH (green) as earth continuity conductor fixed to fabricated sheet wall with suitable clamps and fixing accessories, and connecting to common earth dolly complete all as specified and as directed.
(a) Two runs of 6 sqmm cable and one run of 6 sqmm cable and one run of conduit will be measured as one length.
(b) Cost of terminal box is deemed to be included in the item rates quoted for sub-main wiring / circuit wiring.
Earthing complete with galvanised iron earth plate electrode 600mm X 600mm X minimum 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
SCH "A" PART-III (EXTERNAL ELECTRIFICATION)
Supply, laying, connecting and testing XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, in trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments of the following sizes complete all as specified and as directed.
(a) Earthwork, sand cushioning, protection for cable etc., as required shall be measured and paid separately.
(b) Lugs and glands shall be used appropriately wherever required while connecting cables to the panel board and the quoted rates are deemed be include for the same.
(a) 3.5 core, cross sectional area 35 sqmm.
(b) 3.5 core, cross sectional area 70 sqmm.
Steel tubing, galvanised, light grade, with all fittings such as bends, elbows, tees etc., and laid in trenches / under roads / crossings etc., of bore of pipe 50mm for cable protection complete all as specified and as directed.
Earthwork, cutting across roads etc., as required shall be measured and paid separately.
Steel tubing, galvanised, light grade, with all fittings such as bends, elbows, tees etc., and fixed on poles of bore of pipe 50mm for cable protection complete all as specified and as directed.
Dry river sand laid to required width of trench at bottom and top for cable cushioning all as specified and as directed.
Punned thickness only shall be measured.
Burnt bricks sub class "B" of old size, designation 50, laid dry in trenches with width equal to length of bricks across the cable for cable protection all as specified and as directed.
MCCB 400 Amps, 4 pole, 415 Volts, 3 phase, 50 Hz, 35 kA breaking capacity, with adjustable thermal and adjustable magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 75% of Icu having spreader links and barriers as standard feature of manufacturer complete all as specified and as directed.
(a) Make shall be Havells Cat No.IHLCNFCF0400 or equivalent of makes as listed here-in-after.
Design, fabrication, supply, installation, testing and commissioning of LT panel board, outdoor type, compartmentalised, made up of CRCA sheet minimum 3mm thick and suitable sized angle iron / flat iron frame, top with sloped canopy, botom with detachable plates, with hinged doors, front and back side openable with locking arrangement, louvers and air vent for natural air flow, chamber for cable entry and exit and busbars, weather, dust and vermin proof, epoxy powder coated, to minimum IP-54 protection class of IS-2147, pedestal mounted, LT 415 volts, 3 Phase, 4 wire, 50 cycles, including cable galleries, interconnecting bus-bar connection / linkage, suitable for housing and including provision of the following switch gears including all pre-wiring with PVC copper conductor cable of suitable size, nuts, bolts and washers and cable connection with suitable size aluminium lugs and glands in accordance with IS-13947 (Part-I) 1993 & IS-8623 including dismantling existing LT panel board including components all as specified and directed by Engineer-in-Charge.
(a) Aluminium bus bar with rating 400 Amps for 3 phase and neutral with heat shrinkable PVC coloured sleeves and aluminium earth bus of suitable size mounted on SMC insulators - 01 Set
(b) MCCB 200 Amps, 4 pole, 415 Volts, 50 Hz, 35 kA with fixed thermal and fixed magnetic setting - 01 No.(incoming)
(c) MCCB 100 Amps, 4 pole, 415 Volts, 50 Hz, 35 kA with fixed thermal and fixed magnetic setting - 02 Nos.(Outgoing)
(d) MCCB 63 Amps, 4 pole, 415 Volts, 50 Hz, 16 kA with fixed thermal and fixed magnetic setting - 01 No.(Outgoing)
(e) Multifunction meter 3 Phase, 4 W, 240 V, 5 A, flush mounting, Class 1, of size 96mm x 96mm - 1 No.(incoming)
(f) Three phase contactor 20 Amps, with timer for security light - 01 No
(g) LED type pilot indicator lamps RYB phases with backup fuse, Set of three - 01 No.(incoming)
(h) The feeder pillar box shall be mounted by means of suitable bolts and nuts grouted into pedestals of size 600mm x 300mm x 450mm - 2 Nos made of brickwork in CM 1:4, using sub-class "B" old size bricks of designation 50, over PCC foundation of 100mm thickness in PCC 1:4:8, type D2 using 40mm graded stone aggregate, PCC coping average 75mm thick, 1:3:6, type C1, using 20mm graded stone aggregate, the exposed brick / concrete surfaces shall be rendered in CM 1:4, 10mm thick, finished fair and even and applied white wash three coats.
The MCCB shall be made with suitable arrangement for front operation.
Mariammal Constructions
UNITED ENGINEERS CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .