Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.7 LAccepted-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹22.9 L+₹1.7 L (8.08%)Rejected-AOC | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹23.0 L+₹1.8 L (8.38%)Rejected-AOC 144 VIKAS BAZAR MATHURA UP 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L3 | Rejected-AOC Other than L1 | |
| 4 | L4₹29.8 L+₹8.6 L (40.8%)Rejected-AOC | L4 | Rejected-AOC Other than L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
9 Jan 2023, 6:00 pmClosed
Mathews M Shepherd, GE
GE (West) Mathura
REPAIR/MAINT/REPLACEMENT OF DG SETS UNDER GE(W) MATHURA
2022_MES_568342_1
8300/1106/E8
Open Tender
Civil Works
Item Rate
180 days
Mathura Cantt
As per Tender Document
9 documents required · 9 mandatory
₹500
GE (West) Mathura
₹60,000
Yes
23 Feb 2023
12 Dec 2022
16 Jan 2023
12 Dec 2022
9 Jan 2023
27 Dec 2022
Amount
M&l for repair, maintanance and servicing of DG sets of capacities ( 30 KVA to 160KVA) of any make & type including dismantling of top / head of DG set for thorough inspection by Engineer-in-Charge and carrying out work as under (i) Checking & adjustment of tappet clearance (ii) Cleaning cylinder & piston head by removing the carbon deposits (iii) Checking general condition of the Engine (iv) Checking & adjustment of operating parameters (v) Checking & adjustment of fuel timing (vi) Checking & adjustment of fault warning system (vii) Replacment of the damaged gaskets and re-assembling the same after repair , servicing / replacement of unsv / worn out nut bolts including testing of DG set on full load as per time directed by Engr-in-Charge :- Notes:- Servicing of DG set will be done by Authorised dealer of Kirloskar / Cummins only.
M&L for repair, maintanance and servicing of DG sets of capacities ( 200 KVA to 400KVA) of any make & type including dismantling of top / head of DG set for thorough inspection by Engineer-in-Charge and carrying out work as under (i) Checking & adjustment of tappet clearance (ii) Cleaning cylinder & piston head by removing the carbon deposits (iii) Checking general condition of the Engine (iv) Checking & adjustment of operating parameters (v) Checking & adjustment of fuel timing (vi) Checking & adjustment of fault warning system (vii) Replacment of the damaged gaskets and re-assembling the same after repair , servicing / replacement of unsv / worn out nut bolts including testing of DG set on full load as per time directed by Engr-in-Charge :- Notes:- Servicing of DG set will be done by Authorised dealer of Kirloskar / Cummins only.
Dismantling of old unseviceable fuel filters with 'O' ring complete and supplying and fixing new Fuel filters elements set (both Primery & Secondary as per model) with 'O' ring as per directed & suitable for following capacities of DG Set (any type or Model): (a) DG Set 30 KVA / 40 KVA
(b) DG Set 140 KVA / 160 KVA
(c) DG Set 200 KVA
(d) DG Set 320 KVA
(e) DG Set 400 KVA
Dismantling of old unseviceable lubricant oil filters cartridge with 'O' ring and including by pass lubricant oil filter cartridge with 'O' ring (as per model) complete and supplying and fixing new oil filter cartridge element with 'O' ring as per directed & suitable for following capacities of DG Set (any type or Model) : (a) DG Set 30 KVA / 40 KVA
(b) DG Set 140 KVA / 160 KVA
(c) DG Set 200 KVA
(d) DG Set 320 KVA
(e) DG Set 400 KVA
Dismantling of old unseviceable Air Filters element with 'O' ring complete and supplying and fixing new air filters (both outer & inner) complete element set with 'O' ring as per directed & suitable for following capacities of DG Set (any type or Model) : Make: Cummins / Mico (a) DG Set 30 KVA / 40 KVA
(b) DG Set 140 KVA / 160 KVA
(c) DG Set 200 KVA
(d) DG Set 320 KVA
(e) DG Set 400 KVA
Supply and replacement of fuel water separator filter complete with benjo bolt and washer for following capacity of DG Sets (any type or Model)complete all as specified and as directed : (a) DG Set 30 KVA / 40 KVA
(b) DG Set 140 KVA / 160 KVA
(c) DG Set 200 KVA
(d) DG Set 320 KVA
(e) DG Set 400 KVA
Dismantling / taking down of radiator assy complete from its mounting from engine and cleaning complete tube with suitable cleaning reagent to remove rust & scaling , plugging of any water leakage by brazing / welding work and re-installing in original position including replacement of rubber hose pipe complete with jupiter clamps for 30 to 160 KVA capacity of DG Sets (any type or Model) complete all as specified and as directed :
Dismantling / taking down of radiator assy complete from its mounting from engine and cleaning complete tube with suitable cleaning reagent to remove rust & scaling , plugging of any water leakage by brazing / welding work and re-installing in original position including replacement of rubber hose pipe complete with jupiter clamps for 200 to 400 KVA capacity of DG Sets (any type or Model) complete all as specified and as directed :
M&L for draining out diesel from fuel tank of DG set of capacity upto 400 KVA and storing the same in clean barrels, cleaning of fuel tanks, checking for any leakages and repairing the same (if any) with suitable welding, refilling the fuel and testing to the entire satisfaction of Engr-in-charge including repairing / replacement of locking arrangement with Key of fuel tank complete all as specified & directed .
M&L for cleaning of oil , grease, dust etc from outer (acoustic enclosures ) and inner surface ( Engine, Alternator, base frame channel and fuel tank) of complete DG set and preparation of old painted surfaces and applying two coats with super enamel paint ( in side of acoustic enclosuress) of colour as specified & directed on Engine, Alternator, base frame channel and fuel tank (except acoustic enclosures ) with the help of air compressor including including writing the machine No. (SM /MES No ) complete all as directed by Engr-in-Charge for following capacities of DG Sets : (a) DG Set 30 KVA / 40 KVA
(b) DG Set 140 KVA / 160 KVA / 200 KVA
(c) DG Set 320 KVA / 400 KVA
M&L for disconnecting unserviceable fuel injection Pump (FIP) of 30 to 160 KVA capacity of DG Set (any type or Model) and transporting to workshop for complete repairing, calibration / overhauling including by replacement of Seal Spring, piston ring , fork liver, bush and minor worn out nuts-bolts, sockets etc including refixing and testing on full load complete all as specified and as directed.
M&L for disconnecting unserviceable fuel injection Pump (FIP) of 200 to 400 KVA capacity of DG Set (any type or Model) and transporting to workshop for complete repairing, calibration / overhauling including by replacement of Seal Spring, piston ring , fork liver, bush and minor worn out nuts-bolts, sockets etc including refixing and testing on full load complete all as specified and as directed.
S&F in replacement flexible coupling with alignment of DG Engine & Alternator including testing for 30 KVA to 160 KVA capacities of DG set (Any Type or Model) complete all as directed.
S&F in replacement flexible coupling with alignment of DG Engine & Alternator including testing for 200 KVA to 400 KVA capacities of DG set (Any Type or Model) complete all as directed.
Dismantling and taking down unserviceable fuel injector with nozzle of any capacity and model of DG Sets and transporting to workshop for overhauling / servicing and calibration, including replacement of injector cup seal, nozzel and plungers etc and testing of injector nozzle on test bench for fine mist spray and refixing complete all as specified and as directed.
M&L drainout of old used engine oil from DG set engine any capacity, and cleaning of oil sump including replacement of worn out Nuts bolts and gasket and filling of new engine oil complete all as specified and as directed. Note: Engine oil shall be measured and paid separately.
Supplying and replacement / topping up Engine oil 15W40 grade in DG Set complete all as specified and as directed.
Supplying and replacement / topping up coolant in radiater of DG sets complete all as specified and as directed.
Taking down turbo charger and replacement of complete turbo charge kit with new and fixing to its original position of 30 KVA to 160 KVA capacity of DG Set (any type or Model) complete all as directed
Taking down turbo charger and replacement of complete turbo charge kit with new and fixing to its original position of 200 KVA to 400 KVA capacity of DG Set (any type or Model) complete all as directed
Supply and replacement of Turbo charger including mounting gas kit complete for 30 KVA to 160 KVA DG set (as per existing make & model complete all as specified and directed.
Supply and replacement of Turbo charger including mounting gas kit complete for 200 KVA to 400 KVA DG set (as per existing make & model complete all as specified and directed.
M&L for dismantling of Exhaust pipe of silencer, cleaning of silencer to remove carbon deposit inside barrel and refixing including replacement of worn out rubber gasket packing and nut,bolts complete all as specified and as directed.
Dismantling unserviceable battery charging alternator 24V, DC of DG sets, transporting to workshop, complete repairing / overhauling by replacing unsv parts such as carbon brush, bush, nuts & bolts, solinoid switch, bearing, armature, burnt winding including installation, commissioning & testing to function for charging of battery complete all as directed.
Dismantling of defective battery charging alternator from DG engine, supplying and fixing new alternator 24 Volt DC including replacement of worn out nuts bolts mounting clamp etc. complete all as specified and as directed.
S&F in replacement of fuel (diesel) pipe of 1250 PSI complete with brass banjo bolt & washer etc complete for DG Set of any capacity any make as per site requirement, complete, all as specified and directed.
Supply and replacement of compact type panel mounted battery charger suitable for charging 02 Batteries 12 V each including necessary connection with suitable size of copper wire complete for functional to charging of battery & testing all as specified and as directed.
Supply and replacement of compact type panel mounted battery charger suitable for charging 01 Batteries 12 V each including necessary connection with suitable size of copper wire complete for functional to charging of battery & testing all as specified and as directed.
Dismantling of unserviceable oil pump of DG Set any capacity & type for servicing ,cleaning, calibration, testing including replacement of worn out bushes, seal, 'O' Ring, Gears, testing and commissioning complete all as specified and as directed.
Dismantling of unserviceable water pump of 140 to 320 KVA DG and servicing ,cleaning, calibration, testing including replacement of worn out parts , testing and commissioning complete all as specified and as directed.
Dismantling of unserviceable self starter 24V DC and transporting to workshop for complete repairing by replacing unserviceable parts / burnt winding such as carbon brush, bush, nuts & bolts, solenoid switch, bearing, drive penion and rewinding of armature & field coil , replacement of gear assembly and after repair inatallation, commissioning & testing complete all as specified & directed.
Dismantling of unserviceable self starter 12V DC and transporting to workshop for complete repairing by replacing unserviceable parts / burnt winding such as carbon brush, bush, nuts & bolts, solenoid switch, bearing, drive penion and rewinding of armature & field coil , replacement of gear assembly and after repair inatallation, commissioning & testing complete all as specified & directed.
Dismantling unserviceable self starter and supply & fixing in replacement new self starter 24 Volt DC with solonoid switch suitable for DG set (as per existing model) including connecting, testing & commissioning to make functional complete all as directed.
Supplying and replacement V-Belt off sizes for 30 to 160 KVA DG set complete all as per site requirement, complete all as specified and as directed.
Supplying and replacement V-Belt off sizes for 200 to 400 KVA DG set complete all as per site requirement, complete all as specified and as directed.
Supplying and replacement of Oil pressure gauge ISI mark complete all as specified and as directed.
Supplying and replacement of oil temperature gauge ISI mark complete all as specified and as directed.
Supplying and replacement of Fuel gauge meter ISI mark operated on 24V DC / 12 V DC as per site requirement complete all as specified and as directed.
S&Fin replacement door hinge for sound proof acoustic enclosure of DG set complete with suitable arrangement to fixing in door as existing and complete all as specified & directed.
S&F in replacement door locks with key and opening handle suitable for sound proof acoustic enclosure of DG set complete with suitable arrangement to fixing in door as existing complete all as specified & directed.
S&F in replacement maintenance free Lead Acid Battery 12V, 180 AH with initialy charged complete with installed at site complete all as specified & directed.
S&F in replacement maintenance free Lead Acid Battery 12V, 150 AH with initialy charged complet with installed at site complete all as specified & directed.
S&F in replacement copper battery lead 1.5 mtr length red colour suitable for 180 AH battery complete with copper terminals both end including connection complete all as specified & directed.
S&F in replacement copper battery lead 1.5 mtr length black colour suitable for 180 AH battery complete with copper terminals both ends including connection complete all as specified & directed.
S&F in replacement copper battery terminal with Nut bolts suitable for 180 AH battery complete with fixing at site complete all as specified & directed.
Supply and filling / replacement of electrolyte for battery complete all as specified & directed.
Dismantling the alternator of capacity 30 KVA to 160 KVA (any make & Model) from DG set and carrying out cleaning, servicing, appying one coat of insulation varnish over stator and rotor winding and heating, replacement of spare parts like main bearing, main terminal boards re-assembling and re-installing in its original position and testing on completion to the satisfaction of Engineer-in-Charge complete all as specified and directed.
Dismantling the alternator of capacity 200 KVA to 400 KVA (any make & Model) from DG set and carrying out cleaning, servicing, appying one coat of insulation varnish over stator and rotor winding and heating, replacement of spare parts like main bearing, main terminal boards re-assembling and re-installing in its original position and testing on completion to the satisfaction of Engineer-in-Charge complete all as specified and directed.
S&F in replacement of Automatic voltage regulator ISI mark as per existing make and model and suitable for 30 KVA to 160KVA rating alternator complete with all connection as specified and as directed.
S&F in replacementof Automatic voltage regulator ISI mark as per existing make and model and suitable for 200 KVA to 400 KVA rating alternator complete with all connection as specified and as directed.
M&L for repairing AMF panel & connected electric function of engine of DG Set including setting of engine command controller display (any type or capacity of DG) , detecting the electric fault, removing the defective control wiring and spare parts to make AMF panel functional to DG Set by replacement of following defective spares complete all as specified & directed. Note:- (i) Spare parts will be measured & paid seperately as supply only. (ii) Taking down & refixing shall be deemed to be included in unit rate. (iii) Replacement of burnt control wiring shall be deemed to be included in unit rate. (iv) Repairing of AMF Panel of DG set will be done by Authorised dealer only.
Supply only Timer with realy 230 volts, 50 Hz AC of rating (03-60 second) and as per existing type used in AMFcomplete all as specified & directed.
Supply only Over voltage / Low voltage relays of rating ( 370-460V) and as per existing type complete all as specified & directed.
Supply only Auxiliary contacts with 1NO+1NC (including LHS & RHS)suitable for MCX-34 power contactor complete all as specified & directed.
Supply only Auxiliary contacts with 1NO+1NC (including with 02 Nos LHS & 02 No RHS) suitable for MCX-43 power contactor complete all as specified & directed.
Supply only Contactor coil 230 Volts, 50 Hz AC suitable for 3poles power contactor ML-12 type complete all as specified & directed.
Supply only Contactor coil 230 Volts, 50 Hz AC suitable for 4 poles power contactor MCX-43 type complete all as specified & directed.
Supply only Contactor coil 230 Volts, 50 Hz AC suitable for 4 poles power contactor MCX-34 type complete all as specified & directed.
Supply only power contactor 3 pole, ML-12 type 415 volts with 2NO+2NC auxiliary contacts and coil with voltage 230 volts, 50 HZ AC complete all as specified & directed.
Supply only power contactor 4 pole, MCX-43 type 415 volts with 2NO+2NC auxiliary contacts and coil with voltage 230 volts, 50 HZ AC complete all as specified & directed.
Supply only power contactor 4 pole, MCX-34 type 415 volts with 2NO+2NC auxiliary contacts and coil with voltage 230 volts, 50 HZ AC complete all as specified & directed.
Supply only power contactor 4 pole, MCX-32 type 415 volts with 2NO+2NC auxiliary contacts and coil with voltage 230 volts, 50 HZ AC complete all as specified & directed.
Supply only power contactor 3 pole, MNX-400 type 415 volts with 2NO+2NC auxiliary contacts and coil with voltage 230 volts, 50 HZ AC complete all as specified & directed.
Supply only power contactor 3 pole, MNX 80 type 415 Volt with 3NO+1NC ( MNX-A1 )add on block auxiliary contacts and coil with voltage 230 volts, 50 HZ AC complete set complete all as specified & directed.
Supply only power contactor 3 pole, MNX-225 type 415 volts with 2NO+2NC auxiliary contacts and coil with voltage 230 volts, 50 HZ AC complete all as specified & directed.
S&F in replacement automatic engine controller microprocessor based DGC-6D type for automatic DG start and supervisory control device flush mounted enclosure including PCC board kit unit with connection to make functional to AMF panel and complete wiring connection with testing complete all as specified & directed.
S&F in replacement automatic Generator engine controller microprocessor based display unit for automatic DG start and supervisory control device including PCC board kit unit with connection to make functional to AMF panel and complete wiring connection with testing complete all as specified & directed.
S&F in replacement power command controller HMI211 display panel kit Model 0541-1394 including PCC board kit unit with connection to make functional to AMF panel and testing complete all as specified & directed.
S&F CT coil off ratios for as per site requirement complete all as specified and as directed.
S&F in replacement of Digital meter square type suitable for measuring 3-PH combined Voltage, Ampere & Frequency simultaneously in three independent windows with ultra LED display complete all as specified & directed.
S&F in replacement of Digital meter square type suitable for measuring frequency in three digits with 0.1 Hz resolution and having ultra LED display complete all as specified & directed.
S&F in replacement of LED Indicator lamp (Red , Yellow ,Blue & Green ) suitable for DG Panel complete all as specified & directed.
S&F in replacement of Start & Stop Push button / Switch as per suitable for existing panel complete all as specified & directed.
S&F in replacement of Operating Handle Kit (handle + shaft +center bush + bush clip) of On load & Panel mounted type changeover switch any capacity & rating as per existing complete with fixing to make functional with operating handle complete all as specified & directed..
S&F in replacement On-Load Changeover Switch( I-O-II) , 415 volts, 50 Hz, four pole of capacity 400 Amps with open execution type and with operating handle including replacement of incoming and outgoing lugs and provision of fixing arrangement on panel with all connection complete all as specified & directed.
S&F in replacement On-Load Changeover Switch( I-O-II) , 415 volts, 50 Hz, four pole of capacity 400 Amps with SS enclouser and with operating handle including replacement of incoming and outgoing lugs and provision of fixing arrangement on panel or as per direction with all conection complete all as specified & directed.
S&F Automatic transfer switch AC with encloure, 415 volts, 50 Hz, four pole of capacity 200 Amps for automatic and manual operation with complete protection including fixing arrangement on panel / wall complete with all necessary controll wiring to make functional of ATS complete with testing complete all as specified & directed.
S&F in replacement MCCB 4 poles 415 volts adjustable thermal and adjustable magnetic setting type of capacity 200 Amps (frame as per existing) with breaking capacity 36 KA including fixing arrangement on panel/wall complete all as specified & directed.
S&F in replacement MCCB 3 poles 415 volts, 160 Amps (frame as per existing) with breaking capacity 36 KA including fixing arrangement on panel/wall complete all as specified & directed.
S&F in replacement MCCB 4 poles 415 volts, 400 Amps (frame as per existing) with breaking capacity 36 KA complete including fixing arrangement on panel/wall complete all as specified & directed.
Supply, laying, jointing and testing of XLPE insulated, sheathed, armoured, heavy duty electric cable with stranded aluminium conductor 1100 volts grade cross section area 185 Sqmm 3.5 core and laid in trenches / duct / fixing on panels /walls /poles or passing through pipe including connecting with suitable lugs, thimble ,glands, nuts and bolts to exist Panel / DG set and testing complete including taking out the old burnt out cables any size or type complete all as specifed & directed. Note: (i) LT Cable joint , Lugs, Thimble, Gland, Nut & bolts shall be included in quoted item rate.
Supply, laying, jointing and testing of XLPE insulated, sheathed, armoured, heavy duty electric cable with stranded aluminium conductor 1100 volts grade cross section area 120Sqmm 3.5 core and laid in trenches / duct / fixing on panels /walls /poles or passing through pipe including connecting with suitable lugs, thimble ,glands, nuts and bolts to exist Panel / DG set and testing complete including taking out the old burnt out cables any size or type complete all as specifed & directed. Note: (i) LT Cable joint , Lugs, Thimble, Gland, Nut & bolts shall be included in quoted item rate.
Supply, laying, jointing and testing of XLPE insulated, sheathed, armoured, heavy duty electric cable with stranded aluminium conductor 1100 volts grade cross section area 95Sqmm 3.5 core and laid in trenches / duct / fixing on panels /walls /poles or passing through pipe including connecting with suitable lugs, thimble ,glands, nuts and bolts to exist Panel / DG set and testing complete including taking out the old burnt out cables any size or type complete all as specifed & directed. Note: (i) LT Cable joint , Lugs, Thimble, Gland, Nut & bolts shall be included in quoted item rate.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables and getting out soft/loose soil complete all as specified & directed.
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified & directed.
Returning, filling in including spreading, levelling,watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified & directed.
M&L for sand cushioning and covering clean and dry sand to underground electric cable with 8 cm before laying and 10 cm over the cable including ramming complete all as specified and directed. Note :- Punned thickness shall be measured and paid for.
M&L for laying in trenches un-reinforced precast cement concrete cable cover, class LV type 1, flat, size 250mmx150mmx40mm for cable protection laid adjacent to each other length wise perpendicular to the central axis of cable complete all as specified and directed.
S&F in replacement end termination cable jointing kit heat shrink type for 1.1 KV grade cable and suitable for indoor/outdoor complete with jointing accessories including nut bolts, thimble, lugs and suitable for 3 1/2 4 core XLPE armored AIuminium conductor cable of size 95 to 185 sqmm complete all as specified and as directed.
Supply & installation ABC stored presure type fire extinguishers 6Kg cap having jet pressure range of 6mtr including taking out old unserviceable any type and capacity complete all as specified and directed.
M&L for preparation of old painted surface on any type and applying two coats of synthetic enamel paint complete all as specified and directed.
M&L for writing letters or figures (Block, Roman, Italic or Indian) n. exc. 30 cm high, letters or figures shall be painted with flourecent paint they stand out boldly and solidely without showing brush marks complete all as specified and directed.
M&L for writing Index hand(natural size) or arrows (upto 40 cm long) with flourecent paint without showing brush marks complete all as specified and directed.
M&L for writing stop, commas, short lines, dashes, hyphens, brackets etc with flourecent paint without showing brush marks complete all as specified and directed.
M&L for earthing for DG sets & AMF panels complete with galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 mtr below normal GL with the top edge of the plate not less than 1.5 mtr below the normal ground level connected to GI strip of size 32mmx6mm and watering pipe 20 mm bore GI pipe ( medium grade ) and chamber PCC(1:4:8) type D2 using 40 mm graded stone aggregate, coping shall be (1:3:6) type C1 using 20 mm graded stone aggregate and RCC (1:2:4) type B1 using 20 mm graded stone aggregate pit cover 50 mm thick re-inforced with 8 mm tor MS bar at 80 mm c/c both way including excavation and earth work and removal of surplus soil of earth complete all as shown in electrical plate No. 3 of SSR Part-I and as specified including test point,charcoal dust,common salt complete and earth lead upto 7.5 Mtr connected to earthing test point all as specified and testing of eathing on completion complete all as specified and directed.
M&L for GI strip of size 32x6mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle/insulator as required and connecting to panel/body and dismantling unserviceable strip any type/size complete all as specified and directed.
M&L for detecting the faulty / burnt electric cable of any size from DG set to DG Panel / Main Panel by trench out and length / distance not exceeding upto 30 RM and repair / joint the electric cable through cable joint kit as per suitable size and make panel functional with all incoming and outgoing cable connection including tightening loose cable / strip connections, removal of dirt,dust and carbon particles by air blower, rubbing emmery paper replacement of worn out thimbles,nut, bolt & washers , replacement of control wiring of panel etc including with excavation, returning filling & removal of excavated surplus soil to a distance not exceeding 50 mtr complete to complete all as specified and as directed. Note : (i) Additional spare parts such as Cable , cable joint kit , MCCBs will be measured & Paid separetly under relevent item of Sch 'A' as supply & fixing. (ii) Replacement of burnt control wiring of panel, Cable lugs, nut- bolts , thimble etc. shall be deemed to be included in unit rate.
S&F in replacement MCCB 3 poles 415 volts adjustable thermal and adjustable magnetic setting type of capacity 250 Amps with breaking capacity 36KA complete including fixing arrnagment on panel/wall complete all as specified and directed.
S&F in replacement MCCB 3 poles 415 volts,100 Amps with breaking capacity 10KA complete inclduing taking down exising unserviceable including fixing arrnagment on panel/wall complete all as directed.
S&F in replacement DG Engine heat sensor switch and Radiator heat sensor switch as per existing model complete with testing complete all as specified and directed.
S&F in replacement maintenance free Lead Acid Battery 12V, 90 AH with initialy charged complet with installed at site complete all as specified and directed.
S&F in replacement Automatic transfer switch AC with encloure, 415 volts, 50 Hz, four pole of capacity 400 Amps for automatic and manual operation with complete protection including fixing arrangement on panel / wall complete with all necessary controll wiring to make functional of ATS complete with testing complete all as specified and directed.
Dismantling alternator from the engine base of DG set any capacity and rewinding of field coils of alternator with super enamelled wire including varnishing and heating including reassembling and testing for capacity of DG Set form 30 KVA to 400 KVA complete all as specified and directed.
S&F in replacement earth fault module of 200 Amp rating suitable for 3 phase 415 volt 4 wire system with connection complete all as specified and as directed.
S&F in replacement of Radiator core made up of copper of cap upto 320 KVA DG set complete all as specified and directed.
S&F in replacement By Pass switch 415 volts, 50 Hz, four pole of capacity 400 Amps with open execution type including with 2NO+2NC auxiliary contacts and with operating handle including replacement of incoming and outgoing lugs and provision of fixing arrangement on panel with all conection complete all as specified and as directed.
S&F in replacement of ECM (Electronic Control Module) unit control device for 160 KVA with ECM connector relay unit set and all connecting accessories with control wiring testing complete all as specified and directed.
S&F in replacement of Actuator suitable for 320 KVA DG Set with all connecting accessories & control wiring testing complete all as specified and directed. Note :The contractor will be fully responsible for providing the trend DG technician within 02 hours to rectify the defect in DG set and AMF panel. If the contractor loses his responsibility, the contractor will be fined at the rate of 10000/- per day till the fault is rectified and penalty will be deducted from his due payment.
M/s KCL Engines and Machines
M/s DEVI DAYAL CONSTRUCTION CO
ASHOK INFRATECH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .