Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.3 LAccepted-AOC 164 A 11 GALI NO 3 RISHI NAGAR KAITHAL 136027 | KAITHAL | HARYANA | 136027 | L1 | Accepted-AOC LOA issued | |
| 2 | L2₹31.6 L+₹25,072 (0.80%)Rejected-Finance 62 PINK ROSE COLONY KAIMARI ROAD 125001 | HISAR | HARYANA | 125001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹31.9 L+₹56,928.90 (1.82%)Rejected-Finance MEHEM ROAD NEAR TVS BIKE AGENCY GOHANA SONIPAT HARYANA 131301 ON MEHAM ROAD NEAR TVS BIKE AGENCY GOHANA 131301 | SONIPAT | HARYANA | 131301 | L3 | Rejected-Finance L3 | |
| 4 | L4₹31.9 L+₹57,001.50 (1.82%)Rejected-Finance KHASRA NO 183 10 SHYAM VIHAR HISAR HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L4 | Rejected-Finance L4 | |
| 5 | L5₹32.9 L+₹1.6 L (4.99%)Rejected-Finance H NO 959 SECTOR 3 ROHTAK | L5 | Rejected-Finance L5 |
Tender Value
₹34.8 L
EMD Value
₹69,620
Closing Date
8 Aug 2023, 5:00 pmClosed
AMIT GOYAL
ED - Karnal
Providing 315 KVA Electrical Sub Station in the campus of SDO Civil Complex at Samalkha Distt. Panipat.
2023_HRY_297895_1
20230A7A1E6A FBB9 43B0 9CD3 99F8A92A63B7665BAR
Open Tender
Electrical Works
Works
90 days
Samalkha
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹69,620
Yes
13 Mar 2024
17 Jul 2023
9 Aug 2023
18 Jul 2023
8 Aug 2023
18 Jul 2023
Amount
[23.1.6.5]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 6.5. Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 10 Sqmm(1/3.50 mm)
[23.22.1.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 125 to 160 amp, 25 KA
[23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA
[23.22.1.12]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.12. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 300 to 400 amp , 50 KA
[23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA
[23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP
[23.22.2.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.2. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 250 A FP
[23.22.2.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.3. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB above 250 A and up to 630 A FP
[23.22.4.6]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.6. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 6 way ( 8 incoming 3phase*6 outgoing)
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole
[23.22.5.3]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.3. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Double POLE
[23.22.5.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.7. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp MCBs FOUR POLE
[23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE
[23.26.1]SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages.
[23.26.2]SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages.
[23.26.3]SAFETY ITEMS 3. Supply and erection of shock restoration chart in glass frame.
[23.26.4]SAFETY ITEMS 4. Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6x4 made of GI pipe 32mm dia).
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required.
[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
[24.1.6]EARTHING AND LIGHTENING ARRESTOR 6. Supplying and laying 25mm x 3mm G.I. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required.
[24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.
[24.10.1]CIVIL ITEMS (USED COMMONLY IN ELECTRICAL WORKS) 1. Digging & refilling of trench 30 cm wide below ground level for erection of pipe/cable (up depth of 1 Metre. underground cable excluding the cost of cable/pipe complete in all respect.
[24.2.7.6]LT CABLE 7.6. Supply and erection of suitable compression type brass cable glands for underground Cable :- 240 sqmm to Cable 3 to 32 Core
[24.2.8.13]LT CABLE 8.13. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 240 sqmm
[24.3.3.1]HT CABLE 3.1. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm
[24.3.4.1]HT CABLE 4.1. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm
[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia
[24.5.2.5]MISCELLANEOUS ITEMS 2.5. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 120/105 mm outer dia/ inner dia
[24.7]RCC FOUNDATIONS FOR DG SET "Providing RCC foundation of M20 grade (1 Cement:1.5 Stone aggregate: 3 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 50 kg/cum of concrete contents, concrete cover 50mm, over a bed of 75mm thick PCC 1:5:10, of required dimensions as per OEM recommendations to provide levelled surface for placement of the DG set complete in all respects and as per directions of Engineer-in-charge (Size of foundation assumed = 5.0x1.8x1.0m)" Unit: per cum
Pdg. And Fixing of wire mesh jali around the transfarmer of size 4` x 8` made out of 75 x 25 x 3.25 mm jali fixed with angel iron frame made out of M.S. Angel 50 x 50 x 6 mm.
Supply and erection of stay set with stay wire suitable for 9M long PCC pole made out of 7/3 SWG GI wire with U type M.S. Rod 5/8` dia duly threaded by means of angle iron of size 50 x 50 x 6 mm x 30 cm 6 feet long M.S. Rod buried in ground after fixing with cross channel size 75 x 40 x 6 mm x 60 cm long the stay wire will be binded on the top of the pole with help of suitable size of double U type M.S. Clamps and stay fixed with nuts and bolts the stay wire shall be insulated in the middle point with the help of egg insulator including all labour and material required to complete the job in all respect to the entire satisfaction of Engineer-in-charge of work.
Supply and erection of prestressed cement concrete pole as per IS : 1678-1960. 9 metres long 105 mm x 115 mm at top and 105 mm x 315 mm at bottom with working load of 200 Kg. burried 1.80 m in ground. (Make and specification as per UHBVNL/UHBVNL) including Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1 :3:6) layer on top with including excavation and refilling etc as required (As per HSR 24.4.10.4.) Above 8.0 metre and up to 11.0 metre.
Supply and Erection of rubber mat of size 1Mx2 M X 12mm thick suitable for 11 KV ISI marked complete in all respect upto the entire satisfaction of the engineer In-charge of the work.
Supply and erection of 16 Sqmm 4 Core under ground cable on surface/ cable tray / pipe / trench etc. complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work Make RR / Havells / Polycab
Supply and erection of 25 Sqmm 04 Core under ground cable on surface/ cable tray / pipe / trench etc. complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work Make RR / Havells / Polycab
Supply and erection of 35 Sqmm 04 Core under ground cable on surface/ cable tray / pipe / trench etc. complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work Make RR / Havells / Polycab
Supply and Erection of fire buckets of 9 ltr. capacity made out of 24guage G.l sheet and duly painted with one coat of red oxide and 2 coats of approved paint in red colour and written with the fire` as per fire protection necessar sand filling in the bucket hung the bucket on stand with all labour and material required to complete the job all respect up to entire \satisfaction of the Engineer m charge of the work
Supply and erection of ACSR conductor (ISI Marked) with accessories including stringing and sagging of conductor of various sizes as well as jointing and binding with insulator at support complete in all respect up to entire satisfaction of Engineer-in-charge of the work. ACSR Cond. 50 Sqmm (Make and specification as per UHBVNL/UHBVNL).
Supply, stringing and sagging of GSL wire 8 SWG complete in all respect with erection of the same upto the entire satisfaction of the Engineer in Charge of work (Make and specification as per UHBVNL/UHBVNL)
Supply and erection of MS channel 100x50x6mm including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect upto the entire satisfaction of Engineer-in-charge. (Make and specification as per UHBVNL/UHBVNL)
Supply and erection of MS angle 50x50x6mm including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect upto the entire satisfaction of Engineer-in-charge. (Make and specification as per UHBVNL/UHBVNL)
Supply and erection of MS flat 50x6mm including cutting bending to the required shape drilling hole carriage Painting loading unloading complete in all respect upto the entire satisfaction of Engineer-in-charge. (Make and specification as per UHBVNL/UHBVNL)
Providing and fixing of Nut and Bolt of size as per ISI specification of Engineer-in-charge. (Make and specification as per UHBVNL/UHBVNL)
Supply and erection of 11KV GI pin insulator with pin Rashtriya / Jayshree / BHEL make with pin with all labour and material required to the complete the job included the fixing the same on existing channels up to entire satisfaction of the Engineer-in-Charge of the works. (Make and specification as per UHBVNL/UHBVNL)
Supply and erection of 11KV gang operated switch Rashtriya / Jayshree / BHEL make conforming to IS with latest amendment including suitable size of copper blade erection of same on the existing `H`pole with the help of 3 Nos. channels of size 75mmx40mmx6mm, 1.8M long fixed with suitable size of MS clamp, nuts and bolts including cost of 6 Nos. 11KV insulator with GI pin, RD fuses and painting with 2 coat of approved paint and one coat of red oxide material required to complete the job in all respect up to entire satisfaction of the Engineer-in-Charge of the works. (Make and specification as per UHBVNL.
Supply Erection Testing and Commissioning of 11kV indoor HT metering panel indoor / outdoor complete with C.Ts P.Ts Cubical .as per requirement / approved by UHBVNL consisting of the following. - Cubical panel free standing floor mounting type made out of sheet steel 16 SWG CRCA sheet with channel iron base frame spray painted with strong synthetic light grey enamel paint as per size and design approved by the UHBVNL. - 3 Nos. 11KV CTS of rating as approved by UHBVNL for indoor installation of approved make of UHBVNL. - 1 Nos. 11KVPTS 11000/10 VA burden 0.5 accuracy oil filled suitable for indoor installation of approved make of UHBVNL. ` `The cubical panel will be completed in all respect including inter connection, internal wiring with PVC copper cable, modem and allied accessries its testing and approval of all item by UHBVNL cost of all testing/ approval charges or all items of UHBVNL with a guarantee of one year from the date of commissioning. including cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the engineer in charge of the work
Supply and Erection of Digital Electronic Trivector Meter 3 phase 4 wires 0.5 accuracy for recording reading in KWH / KVARH / KVAH of make and rating approved by UHBVNL with push button display operating system for different kind of readings suitable for dual metering including cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the engineer in charge of the work. (Make and specification as per UHBVNL/UHBVNL)
Supply of Disc insulator Rashtriya / Jayshree / BHEL make with Disc fitting TandC type complete in all respect with erection of the same upto the entire satisfaction of the Engineer in Charge of work (Make and specification as per UHBVNL/UHBVNL)
Supply and erection of lighting arrestor model ALPRO / Alastem / LEMCO make suitable for 11KV 3 Phase 50 HZ ground neutral system comprising of spare gape type queen gap type in series with non linger resitar element house in Horizontally scale poreclam bushing with line and ground terminal along with mounting clamps conforming to ISS 3070 (Part-I) of 1985 with latest amendment with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works.
Supply and erection 240 Sqmm 3.5 Core of under ground cable on surface/ cable tray / pipe / trench etc. complete with necessary connections complete in all respect upto the entire satisfaction of Engineer in charge of the work Make RR / Havells / Polycab
Supply Installation Testing and Commissioning of of Oil filled 11/0.433KV CU Wound 3 Phaze 50 Hz 315KVA Transformer with OCTC, No load voltage ratio 11/0.433 KV, Vector Group Dyn 11(HV- 11KV- Delta and LV- 0.433 KV- Star), Tapping Range/ Steps plus 5% to -10% in steps of 2.50%, Tap- Changer Off Circuit Tap switch, Tamp. Rise (Oil/Wdg.) 40/45°C, Cooling ONAN- Outdoor Transformer, Termination HV/ LV/ Orientation Cable Box/ Cable Box/ 180°, Impedance 4.5% (Sub to IS Tolerance ) as per IS, Losses @ 50% load 1.025 KW (Max)/ as per Energy efficiency Level 01, Losses @ on 100% load 3.1 KW (Max)/ as per Energy efficiency Level 01, Fitting and Accessories 01 No. Rating and Diagram Plate, 02 Nos. Earthing Terminals, 04 No. Lifting Lugs, 01 No. oil Level indicator with minimum level marking, 02 No. Thermometer Pockets, 01 No. Conservator (Conventional without Air bag only) with oil filling hole with cap and drain plug, 01 No. Air Release plug, 01 No. Silica gel breather, 01 No. off Circuit tap Switch, 04 No. Bi- Directional Rollers, Jacking Pads, Radiators (epoxy painted only), First Filling of Oil (as per IS 335), Epoxy Paint shade #IS:631, Explosion vent, Bottom drain- cum Filter Valve, Top filter valve, Accessories:- 01 No. Marshalling Box, 01 No. WTI with Alarm and trip contacts, 01 No. OTI with alarm and trip contacts, 01 No. Buckholz Relay, HV 75KVp/ 28 KVrms, LV-3/KVrms as per BIS 1180 Level 01 Make Kirlosker/ ABB India/ Siemens/ Schneider/ Crompton/ Alstom/ Bharat Bijli/ NGEF/ Voltamp
Supply and erection of HT XLPE cable 95 Sqmm 3 core including the cost of ibolt for holding of cable etc. including required material to erect on existing .PC.C pole complete in all respect upto entire satisfaction of Engineer-in-charge of the work.
J.B.S.Electrical Co.
PS ELECTRIC
M/s JSB Enterprises
DEVENDER KUMAR CONTRACTOR
Som Nath Contractor
Janta Electric Store
S.S. Enterprises
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .