| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC NO 12 25 26 KATHIRAVAN NAGAR MAHALINGAPURAM PO POLLACHI COIMBATORE 642 002 | COIMBATORE | TAMIL NADU | 642002 | L1 | Accepted-AOC Quoted amount is over all reasonable | |
| 2 | L2₹8.8 L+₹28,000 (3.27%)Rejected-AOC NO 1A 1 SHALOM VALLUVAR STREET SIVANANDHA COLONY COIMBATORE TAMIL NADU 641 012 | COIMBATORE | TAMIL NADU | 641012 | L2 | Rejected-AOC Quoted amount is higher than 1st lowest | |
| 3 | L3₹9.0 L+₹44,589 (5.21%)Rejected-AOC | L3 | Rejected-AOC Quoted amount is higher than 1st lowest |
Tender Value
₹9.9 L
EMD Value
₹19,800
Closing Date
5 Nov 2019, 6:00 pmClosed
Yogesh S Meshram
AGE (i) Agrani Redfields Coimbatore
REPAIR AND MAINTENANCE OF EXTERNAL ELECTRIFICATION WORKS AND LT PANEL BOARD AT INS AGRANI COIMBATORE
2019_MES_287575_1
8725/E8
Open Tender
Civil Works
Item Rate
182 days
Coimbatore
Class- E Category- b (i) / as per NIT document
6 documents required · 6 mandatory
₹500
AGE I Agrani
₹19,800
Yes
8 Feb 2020
5 Oct 2019
7 Nov 2019
5 Oct 2019
5 Nov 2019
19 Oct 2019
5 Oct 2019 - 19 Oct 2019
Amount
Excavation in trenches not exceeding 1.5 Mtre wide and not exceeding 1.5 Metre in depth in hard/dense soil for laying of cable exceeding 1.5 m in depth and getting out complete all as specified.
Returning, filling in, trenches including spreading leveling, watering and well ramming in layers not exc 25 cm.
Removing excavated material to a distance not exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point.
Surface Excavation/Dressing of sub station yards and transformer surroundings not exceeding 30cm deep and an average of 15 cm deep and getting out including removal of small plants and pushes and apply the chemical for not coming the grass in installation complete all as specified and directed.
M&L for cushioning for protection of cable using dry river sand, free from particles all as specified and directed.
M&L for Protection to cable with one layer of new bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks.
M & L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in coping of poles above ground leve including finishing to exposed concrete surfaces even and fair and provision of form work for rough finished surfaces complete all as specified
M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation of poles including finishing to exposed concrete surfaces even and fair and provision of necessary form work for rough finished surfaces complete all as specified and directed
Taking out old unserviceable, burntout , punctured aluminium conductor cable LT, XLPE/PVC, 1100 volts grade, of following cross sectional area from the excavated trenches, ducts, laid in floors, along poles/ walls/ equipments etc., laid and passed through pipes or laid bare in road crossing/drains/ paths/along walls/poles/floors etc and in similar locations complete all as specified and directed by the Engineer-in-Charge:-
95 Sqmm to 70 Sq mm 3.5 core
50 Sqmm to 35 Sqmm 3.5 core
25 Sq mm to 16 Sq mm 4/2 core
Supply and laying in trenches/through pipes or in road crossings/paths /drains/ ducts/floors/along poles/walls/ ceilings/ equipments etc. Cable Under ground, Heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of following cross sectional area :- Make:Gloster/Havells/Finolex
95 Sqmm 3.5 core
70 Sqmm 3.5 core
50 Sq mm 3.5 core
35 Sq mm 3.5 core
25 Sqmm 3.5 core
16 Sqmm 4 core
16 Sqmm 2 core
M&L for taking out faulty UG cable and cutting the faulty end and making joint using out door cable straight through jointing kit (Epoxy/Heat Shrinkable type) suitable for PVC/XLPE under ground aluminium conductor cable, 1100 Volts grade including crimping aluminium socketes of suitable size complete of following cross ectional area :- (Note : Excavation & earth work, sand cushioning, bricks for protection if necessary will be measured and paid sepatately) Make : Raychem/Cabseal/M-Seal/Denson
(a) 70 -150 Sqmm 3.5 core
(b) 25-50 Sqmm 3.5 core
(c) 10-16 Sqmm 4/3.5 core
M&L for taking out faulty UG cable and cutting the faulty end and making joint using cable jointing kit 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm. (Note : Excavation & earth work, sand cushioning, bricks for protection if necessary will be measured and paid sepatately) Make : Raychem/Cabseal/M-Seal/Denson
M&L for taking out faulty UG cable and cutting the fault end and making joint using cable jointing kit 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm. (Note : Excavation & earth work, sand cushioning, bricks for protection if necessary will be measured and paid sepatately) Make : Raychem/Cabseal/M-Seal/Denson
M&L synthetic insulating mat of size 2m x 1m x 12 mm for power house complete all as specified and directed.
M& L for cutting the existing hard standing/PCC/WBM road at a depth not less than 45 cm and 30 cm in width for passing of cable through GI pipe, returning filling in complete including finishing the surfaces by providing cement concrete type B-1 (1:2:4) with 20 mm graded aggregate up to finishing level to a uniform and smooth surface complete all as specified and directed.
Taking out old unserviceable, GI tubing of any size upto 50 mm bore from the excavated trenches, ducts, floors, along poles/ walls/ equipments, road crossing/drains/ paths etc all as specified and directed by the Engineer-in-Charge.
Supply and lay in trenches/under roads/crossings are fixed to wall/pole, GI tubing light grade of following sizes for protection of UG cables . Note : Payment for excavation and earth work shall be paid for separately under relevant items of Schedule. Make:Surya/Jindal/TATA.
(a) 80 mm dia
(b) 50 mm dia
M & L for attending the complaints of the existing ACBs of any rating at main LT Panel Boards and servicing the fixed and moving contacts and blowout the dust and apply the lubricant as recomented by OEM including repair and replace the defective components of ACBs indicator lamps calibrating the relays(OLP, EF Relay and Time dely relay,charging springs etc) Digital meters, servicing and greasing all movable mechanism including replacement of defective fuses,wiring and reassembling and testing complete all as specified and directed. Make of ACBs Siemens
Supply and fix lightning arresters expulsion type complete with all fittings transmission class, discharge capacity of 65 kiloamphere suitable for 11KV complete all as specified and directed Make :BHEL/MEI/GEC
Supply only HT Fuse wire of capacity 25 Amps to 50Apms for 11 KV side
M & L Pin type porcelain, vitreous white Brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut 150mm height 150mm dia for 11000Volts grade complete all as specified . Make:BHEL/Mysore porcelain/madras porcelain
M & L for painting with two coats of synthetic enamel paint over a coat of red oxide primer to existing feeder piller boxes and numbering and maker the location as directed after preparing the old painted surfaces by rubbing and cleaning the dust,rust and existing painting etc complete in FP box and Panel Boards installed in various location complete all as specified and directed. Make : Asian paints/Berger paints/Neuralac
S & F in repairs Digital Multi function Energy meters accuracy class 0.5 Feeder piller /panel Board mounted type to measure Electrical parameters of V, A, F, PF, kW, kVA, etc including suitable ratio CTs in FP boxes and Panels installed at invarious locations of INS.Agrani including replacement of connected wiring with multistranded copper conductor cable etc complete including testing on completion. (Note: Disturbed surfaces of Panel Board to be rectified neatly) Make : L & T/Seimens/Schneider
M & L for loose filling of 40mm graded stone aggregates in outdoor transformer yard /Sub station and panel board yards etc complete all as specified and directed.
S&F Cable route marker of Cast Iron which dia 100 mm and angle iron of 25 x 25 x 4 mm and 1 ft length including all connecting accessories like nut, bolts and washer and burried in ground with PCC (1:2:4) size 100 x 100 x 150 mm complete all as specified and directed by Engr-in-Charge.
M&L ready mix synthetic cold bitumen emulsion/ cold asphalt mixed with desired praportion of fine/ course aggregates in 25 kg bags for repairs to road cutting including preparation of cutting surface by watering ramming to desired density further spreading, levelling and ramming of cold asphalt/ bitumen emulsion as directed by engg in charge
Tree trimming from the tree branches from any height minimum dia 25 mm near two pole structure measured as one job complete all as specified and directed by Engr-in-Charge.
S&F white writing board of size 4 mtr x 2 mtr and draw a complete electric distribution diagram with radium of differnt colour complete all as specified and directed by Engr-in-Charge. Note : Contractor should get approval from Engr-in-Charge before installation.
Supply and fixing flex board including MS sheet box with writing the name of Power house in Aerial Black letters of size 44 inch including angle iron frame of size 25 x 4 mm grouting on to of the installation with suitable nut and bolts including LED light 10 watt complete all as specified and directed by Engr-in-Charge. Note : Contractor should get approval from Engr-in-Charge before installation.
Supply and fixing flex board with writing the name of the installation in front of the installation in Aerial Black letters of size 44 inch including blue painted angle iron 2 Nos. of size 25 x 4 mm of height 3 mtr and MS sheet of size 1m x 0.75m x 3 mm installed on ground with PCC (1:2:4) complete all as specified and directed. Note : Contractor should get approval from Engr-in-Charge before installation.
S&F danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT 25 x 20 cm Size.
S&F danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT 20 x 15 cm Size.
M & L for painting with two coats of synthetic enamel paint over a coat of red oxide primer to existing transformer of any size/caapcity after preparing the old painted surfaces by scraping, rubbing and cleaning the dust,rust and existing painting etc complete all as specified and directed. Make : Asian paints/Berger paints/Neuralac
Disconnecting the 4 core cables from existing MCCB/MCB's installed in LT panel and reconneting the same with new lugs/thimbles to the existing MCCB/MCB in FP box and Panel Boards installed in various location including repair the panel board by doing welding, fixing new hinges 04 Nos., bends, dents etc and replacement of lock complete including repair the panel board by doing welding if necessary and replacement of lockcomplete all as specified and directed. Note : Complete Panel MCCB measured as one Job.
S&F Sheet metal enclosure for DB's double glazed door IP-43 Vertical Triple pole & neutral 4 way with cable end box conforming to IS-8623-1 & 3, IEC 61439-1 &3 made in CRCA sheet steel, RAL 9003 powder coated ready to use DB's provided with insulated vertical phase bus bar, neutral bar with shrouds, earth bar, sticking saddles, cement spill protector, colour coded interconnection wire set, cable ties, blanking plates and circuit identification label with provision for 3/4 pole MCCB as incomer and SP/TP MCBas outgoings cutting the chases for concealed the DB and making good disturb surfaces including taking down of old unsv TPN DB complete all as specified and directed by Engr-in-Charge. NOTE (a) MCCB/MCBs shall be measured and paid separately. (b) All cables terminating into MCCB/MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch 'A'. Make/Model : Cat Part No. DBVTL004GD of make L&T or Cat Part No. CSDBMCCB100DD04IP43S of C&S or equivalent in Schneider.
S&F in repair MCCB four pole, 63 Amps, ultimate breaking cap 36 KA complete conforming to IEC 60947-2 Suitable for isoltaion Ics= 100% of Icu which having adjustable overload setting, adjustable short circuit setting, transparent release cover including suitable spreader terminals complete all as specified. Make/Model : Cat part No. DZ1F0063DXD1AOOOO of make L&T or equivalent in CSE1N125ATM4P of C&S or equivalent in Schneider.
S&F single pole MCB 6 to 16 Amps 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 15 KA breaking capacity conforms to IS/IEC 60947-2 and terminal box suitable upto 35 sqmm cable complete all as specifed and directed. Make/Model : Cat part No. BB10060C of make L&T or Cat part No. CSMBS1C6 of make C&S or equivalent in Schnider.
M&L 11 KV triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level, for current rating upto 200 amps including all connection complete all as specified and directed.
M&L explusion fuses single phase 11 KV above 25 amps & upto 50 amps complete all as specified and directed.
M&L aluminium conductor steel reinforced for jumer including PVC sleeves complete all as specified and directed.
S&F MCCB 4 pole 160 amps of breaking capacity 36 kA conforming to IS /IEC 60947-2, Ics=100%Icu adjustable over load from 0.4 - 1.0 x In, Adjustable short circuit from 1.5 - 8 x Ir, inbuilt Instantaneous protection, inbuilt ground fault protection from 20%-50% of In complete all as specified and directed by Engr-in-Charge. Model/Make : Cat part No. CM92152OOOOAG of make L&T or Cat part No. 3VL2716-2EM46-0AA0 of make Siemens or equivalent in Schneider.
S&F MCCB 4 pole 100 amps of breaking capacity 36 kA conforming to IS /IEC 60947-2, Ics=100%Icu adjustable over load from 0.4 - 1.0 x In, Adjustable short circuit from 1.5 - 8 x Ir, inbuilt Instantaneous protection, inbuilt ground fault protection from 20%-50% of In complete all as specified and directed by Engr-in-Charge. Model/Make : Cat part No. CM92153OOOOAG of make L&T or Cat part No. 3VL2710-2EM46-0AA0 of make Siemens or equivalent in Schneider.
Supply installation, testing and commissioning of outdoor type IP - 66 protection factory fabricated cubical type LT panel board made out of 2.00mm thick CRCA sheet compartamentalised to accommodate the following , TPN aluminium bus bar rating of 200 Amp, bus bar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50mm conical type at a maximum interval of 500 mm through out the length of TPN bus bar, panel shall be front and back open above system, operated from both sides shall have louvers and air vent gasket for natural flow of air 'U' type gasket used to make panel board completely vermin proof single door and mounted on wall including taking out of old LT panel board complete.
The extension link shall not less than 300 mm long supported on DMC/epoxy insulator having provision for termination of incomer and outgoing cables. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN aluminium bus bar of rating not less than 1.5 time rated capacity of individual outgoing feeders. All control wire shall be 2.5 sqmm multi stranded copper conductor and shall be properly bunched, tied ferried for proper identification and crimped with adequate size of lugs. The cubical panel shall have a bottom MS channel of size 75x 40mm duly coated with zinc metal coating having thickness not less than 100 microns. A detachable predrilled suitable size gland plate zinc matel coated should be used at the bottom for entry of cable with lead, complete all as specified and directed for housing and incl of the following items :-
(A) INCOMING (i) Change over switch 125 Amps open execution 4 pole conforming to IS/IEC-60947-3. Make /Model : Cat part No. CSCS125NM4CO of make C&S or CO11250OOOO of make L&T or equivalent in Siemens. - 01 Nos.
(ii) MCCB : 125A, 4 Pole, 36 KA, 415 V, 50 Hz,conforming to IS/IEC 60947-2, Ics = 100% Icu, suitable for isolation, adjustable overload from 0.4 to 1.0 x In and adjustable short circuit from 1.5 - 8 Ir, inbuilt Instantaneous protection, provn of thermal memory : ON/OFF, variable trip class at 7.2Ir to 6 Ir, Front LED indication of Over load including suitable spreader terminal complete all as specifed and directed. Make / model : Cat part No. CM92152OOOOAG of make L&T or Cat part No. CSCN250EM*4P of Make C&S or quivalent in Seimens. - 01 Nos.
(iii) RYB LED indicating lamp - 01 Each
(B) OUTGOING (ii) MCCB four pole, 63 Amps, ultimate breaking cap 36 KA complete conforming to IEC 60947-2 Suitable for isoltaion Ics= 100% of Icu which having adjustable overload setting, adjustable short circuit setting, transparent release cover including suitable spreader terminals complete all as specified. Make/Model : Cat part No. DZ1F0063DXD1AOOOO of make L&T or equivalent in CSE1M125ATM4P of C&S or equivalent in Schneider - 03 Nos.
shalom constructions
JENIFER AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .