Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 CrAccepted-AOC | ₹16.8 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹17.1 CrRejected-Finance 121 MODEL TOWN AMBALA CITY HARYANA 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | ₹17.1 Cr | L2 | Rejected-Finance Being L2 Refer summary |
| 3 | L3₹18.5 CrRejected-Finance 128 CANTT ROAD GARHA JALANDHAR PUNJAB 144001 | JALANDHAR | JALANDHAR | PUNJAB | 144001 | ₹18.5 Cr | L3 | Rejected-Finance Being L3 Refer summary |
| 4 | L4₹18.9 CrRejected-Finance | ₹18.9 Cr | L4 | Rejected-Finance Being L4 Refer summary |
| 5 | L5₹20.4 CrRejected-Finance | ₹20.4 Cr | L5 | Rejected-Finance Being L5 Refer summary |
Tender Value
Refer Docs
EMD Value
₹12.6 L
Closing Date
21 Aug 2021, 6:00 pmClosed
CE AF Udhampur
CE AF Udhampur
PROVN OF CERTAIN STORAGE ACCN AT AF STN LEH
2018_MES_189340_3
CEAF -01/2018-19PROVN OF CERTAIN STORAGE ACCN AT A
Open Tender
Civil Works
1098 days
leh
AS PER TENDER DOCUMENT
10 documents required · 10 mandatory
₹3,000
GE P AF LEH
₹12.6 L
Yes
14 Oct 2021
14 Oct 2020
24 Aug 2021
14 Oct 2020
21 Aug 2021
3 Aug 2021
15 Oct 2020 - 8 Jan 2021
Amount
Total amount of Sch 'A' part-I ( BUILDING WORK)
Total amount of Sch 'A' part-II ( PLUMBING WORK)
Total amount of Sch 'A' part-III (INTERNAL WATER SUPPLY WORK)
Total amount of Sch 'A' part-IV (Section-I) (INTERNAL ELECTRIFICATION WORK)
Sch 'A' Part-IV Section-II (INTERNAL ELECTRIFICATION WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Explosion proof point wiring with 1.5 Sqmm 1100 Volts grade PVC insulated fire retardant multi stranded flexible copper conductor cable in and including ERW rigid steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ceiling with proper fixing arrangements including one No continuous run of 1.5 Sqmm PVC insulated fire retardant solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by One way switch complete all as specified.
LED integrated batten T5 of 18/20Watt, 4 FT, white, indoor decorative PVC extruded T5 LED batten integrated type complete all as specified.
LED tube light fitting , 2 x 20 W flameproof type FLP-WP complete with all accessories prewired and including connecting up with twin core twisted including connecting up with twin core twisted flexible copper conductor cable with suitable size as required.
LED Street light of 25 Watt , IP66 powder coated pressure die cast aluminium compact high power LED street light with heat resistant toughened glass including street light bracket made out of 40mm dia GI Pipe light grade 1.2 mtr long ,bent to shape, with all necessary fittings i.e nuts,bolts, clamps made out of flat iron 50X6mm -02 nos.and necessary electric connection complete all as specified and as directed by Engr-in-Charge.
LED bulk head 30 Watt , IP65, flameproof type CMRI Certified LED Flameproof Bulkhead Luminaire recommended for Gas / Vapor Group of IIA & IIB and Zone 1 & 2, heat resistant toughened glass including connection electrically with twin core flexible cable complete all as specified and as directed by Engr-in-Charge.
Surface mounted LED luminare for mirror lighting 10 watt Complete with lamp including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.50 sqmm all as required.
Lamp holder insulated body with back plate ISI marked for batten fittings including LED 10 Watt complete all as specified.
Bulkhead luminare LED type surface mounted comprising of high brightness LEDs of 10Watt all as specified and as directed
Heavy duty exhaust fan (as per BEE recommendation) 380mm sweep single phase 230 volts 50 Hz AC supply totally enclosed heavy duty motor with die cast alumn rotor mounted on two ball bearings complete louvers including cutting chases for fixing fan, connecting electrically using 3 core 0.75sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site or directed by Engr-in-Charge .
PVC exhaust fan (as per BEE recommendation) 250mm sweep single phase 230 volts 50 Hz AC supply totally enclosed heavy duty motor with die cast alumn rotor mounted on two ball bearings complete louvers including cutting chases for fixing fan, connecting electrically using 3 core 0.75sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site or directed by Engr-in-Charge
Flame proof MCB distribution board encloser double door triple pole with neutral 415 volts 8 way complete with appropriate size bus bar and neutral link confirming to IP 66 complete all as specified and directed and including suitable for following accessories : (i)RCCB four pole 63 Amps with sensitivity 100mA-1Nos (ii) MCB SP 06 to 32 Amps with rupturing capacity 10KA-02 Nos Note:- MCB DB RCCB and MCB to be integrated for flame proofing by manufacturer before installing.
Explosion proof submain wiring with two single core grade PVC insulated fire retardant multi stranded flexible copper conductor cable of size 6 sqmm in and including ERW rigid steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ceiling with proper fixing arrangements including one number continuous run of 6 Sqmm PVC insulated fire retardant solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body all as specified and as directed at site.
MCB single pole & neutral 240 volts 6 to 32 amps,with rupturing capacity 10 KA, ISI Marked.
MCB single pole & neutral 240 volts 50 to 63 amps,with rupturing capacity 10 KA, ISI Marked.
MCB single pole 240 volts 6 - 32 amps, with rupturing capacity 10 KA, ISI Marked
High bay light fitting ,100W flameproof type suitable for 1 & 2 gas,gap II A & II B with IP65 protection alongwith hanging hook clamp/surface mounted complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
High bay light fitting ,50W IP65 protection alongwith hanging hook clamp/surface mounted complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
Sheet metal enclosure DB for MCB TPN double door 4 way complete all as specified and as directed by Engr in charge.
MCB single pole 240 volts 63amps, with rupturing capacity 10 KA, ISI Marked
Supply installation,commissioning and testing of busbar chamber 6 way 63 amps indoor cubical floor mounted type made out of 2mm thick Mssheet duly powder coated complete with busbar 200 amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50 Hz power supply system,with locking arrangement for front/rear door all as required at site and directed by Engr in charge.
Total amount of Sch 'A' part-V (Section-I) (EXTERNAL ELECTRIFICATION AND COMMON NATURE ITEM WORK)
Sch 'A' Part-V (Section-II)( EXTERNAL ELECTRIFICATION AND COMMON NATURE ITEM WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply, fabrication and fixing feeder pillar box outdoor type with canopy made out of MS sheet of 3.15mm thickness bent to shape & size factory made with welding, bending works suitable for and including 200 Amps rated copper bus bars (size not less than 30cm) 4no's of making holes of any size and mounted on porcelain/epoxy based post insulators of size with suitable size of nuts, bolts and washers complete with mounting leg of size 40x40x5 mm and length of angle iron not less than 2.5 mtr 1 mtr to be embeded in PCC below G.L and 1.5 mtr above ground including painting of complete structure with two coats of super enamelled synthetic paint over a coat of red oxide and incoming/out going cable connections with required size of cable lugs with proper crimping. The panel shall comprising of the following fittings and fixture :- i) MCCB 32 Amps, 4 Pole, 10kA, 50 Hz 415V with fixed thermal and fixed magnetic setting- 01No as incoming ii) MCB 32 Amps, SPN, 10kA with fixed thermal and fixed magnetic setting- 01 Nos for security lights iii) Insulated copper bus bar cap 200 Amps of suitable lentgth to suit the size of panel mounted on insulators housed in MS box openable type complete-04 Nos. iv) Wiring complete with suitable size of copper cable PVC insulated from incoming to bus bar and bus bar to out going controls of size matching current rating of control.
Supply, install, testing and commissioning diesel engine driven silent generating set, 415 volts, 200 KVA 3 phase, 0.8 power factor, 50 Hz, brushless, 1500 rpm, self excited, self regulated, AC, and conforming to conditions under IS 4722, BS-5514, 2613/5000 and adhering to CPCB norms with control Panel complete all as specified and as directed with and including following:- (A) ALTERNATOR: Standard design alternator rated at 200 KVA net output at site and at power factor 0.8, AC 3 phase, 4 wire 415 volts, 50 cycles, 1500 rpm, self excited, self regulated, screen protected, drip proof IP-23 enclosure, brushless design with hub and sealed ball/roller bearing, with winding on each pole faces, insulating class H, band of voltage regulation +/- 1% operated voltage from no load to full load and shall conforming to BS-2613/BS-5000 and shell B in position to ganarate supply with frequency regulation within +/- 3% tolerance, revolving field type. (B) DIESEL ENGINE: Adequate capacity diesel engine suitable to above alternator, water cooled, to drive independently above alternator directly coupled to alternator through flexible coupling or multicylinder, multistroke, direct injection, cold starting, 1500 rpm, as per relevant ISI/BS-5514 with an overload cap of 10% for 1 hour in any 12 hours continuous running complete with standard accessories all as specified and required for safe running and operation. salient features of accessories shall be as under:- (i) Flywheel housing (ii)Air cleaner wet/dry type (iii) Fuel Filter (iv) Fuel Injection system incl.injection pump, solenoid switch, nozzle as per manufacturer's specifications (v) Lubricating oil filter, bypass filter, oil cooler CONTD...
(vi) Lubricating oil pump (vii) Turbocharger (viii) Radiator for water cooling (ix) 12 volts starting system consisting of batteries of capacity as recommended by manufacturer, battery connections with copper leads and with lugs of adequate size, initial charging of batteries, battery charger/ generator with regulator, starter motor, starter gear, start and stop push buttons, ignition key and switch. (x) Residential type exhaust silencer complete with exhaust pipe of suitable dia upto outside the accoustic enclosure, all covered with glass wool wrapped with aluminium foil of 28 swg adequate to create draft for safe exhaust without transferring vibrations to buildings/walls, flexible exhaust pipe complete. (xi) Microprocessor control electronic metering and module (ECPG) for indication of battery voltage, oil pressure, water pump, engine rpm, hour meter and protection against low oil pressure, high water temperature and over speed of engine incl. electronic governing. (xii) Battery charging indicator (xiii) Radiator cooling system comprising of radiator, radiator fan belt, water pump with belts, thermostat. (xiv) Fuel hoses. (xv) Separate fuel tank or pay tank made out of 2 mm thick CRCA sheet of suitable capacity not less than 500 litres with level indicator, stop cock, drain plug/valve, breather inlet and outlet connections and all fuel supply lines as required at site and as per manufacturers instructions including return and overflow as well as fuel filling arrangements with piping. (xvi) Air intake system contd...
Electric insulating ISI marked Rubber mats of size 1m x 2m of thickness 2mm (Class-A) , working voltage upto 3.3kV and dielectric strength 30KV complete all as specified and directed.
Street light fitting LED 90 Watts complete connected with wiring of approximate size and duly mounted on bracket of 40 mm bore GI light grade pipe made to shape overall length 1.50 metre with clamps of FI 40 X 6mm to fixing street light fittings and providing PVC insulated conductor cable for suitable size for making connection to light fittings from junction box complete all as specified .Make: HPL/C&S or equivalent in Surya/Havells/phillips.
IP66 High Power 150Watt LED floodlight with pressure die-cast aluminium housing, complete with all accessories.
Junction box of size 200x150x75mm made of MS Sheet 1.6mm thick, front door openable with fixing screw painting with two coats of synthetic enamel paint over a coat of red oxide including alumn bus bar 2 Nos of size 20x3mm mounted on epoxy based post insulators and drilled holes for connection all as required and fixed to poles using MS strip of size 20x3mm and nuts & bolts of required size,MCB 10 A Single pole all as required at site or directed by Engr-in-charge.
PVC insulated PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded Copper conductor of size 2.5 sqmm 2 core 1100 Volts grade complete all as specified and as directed by Engr-in-charge.
Maintenance free chemical ring earthing system complete with 01 Nos. UL 467 approved copper bonded earth rods 17mm dia. 3000mm long electrode buried in ground to bore holes 100mm dia. Vertically to a depth not less than 3.50 Mtr deep below ground level with top edge earth electrode at a depth not less than 500 mm below normal ground level, provision of copper bus bar of size 200mmX25mmX6mm for inter connection with copper earth lead strip 32mmX6mm and further connected to test point terminal block of size 120mmX120mmX25mm made of copper as directed, including 30 Kg (Minimum for each earth pit) NABL Lab Certified back fill chemical compound for filling bore holes with soil mixed, so as to achieve earth resistance below 1 Ohms. including necessary excavation, PCC chamber in PCC (1:3:6) type complete with Pit cover of 300mmX300mm made of Cast Iron with handle etc complete all as specified. NOTE:-(i) If the desired result of less than 1 ohm is not acheived the contractor will do the earthing again with out any extra cost to the department. (ii) The contractor shall refill the earthing by soil brought from outside having good earth resistivity and the cost of the same is deemed to be in the price quoted.
Total amount of Sch 'A' part-VI( Section-I) (EXTERNAL WATER SUPPLY WORK)
SCHEDULE `A' PART-VI(Sec-II)(EXTERNAL WATER SUPPLY WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Kaiflex insulation tubing of size 150mm inner dia and 25 mm thick including jointing, fixing material such as solvent adhesive, tape insulation self adhesive and polyshield coating, including polyglass tape and (Resin+hardner) two coats as per manufacturers recommendation complete all as specified and directed by Engineer-in-Charge.
Kaiflex insulation tubing of size 80mm inner dia and 25 mm thick including jointing, fixing material such as solvent adhesive, tape insulation self adhesive and polyshield coating, including polyglass tape and (Resin+hardner) two coats as per manufacturers recommendation complete all as specified and directed by Engineer-in-Charge.
Kaiflex insulation tubing of size 50mm inner dia and 19 mm thick including jointing, fixing material such as solvent adhesive, tape insulation self adhesive and polyshield coating, including polyglass tape and (Resin+hardner) two coats as per manufacturers recommendation complete all as specified and directed by Engineer-in-Charge.
Kaiflex insulation tubing of size 25mm inner dia and 19 mm thick including jointing, fixing material such as solvent adhesive, tape insulation self adhesive and polyshield coating, including polyglass tape and (Resin+hardner) two coats as per manufacturers recommendation complete all as specified and directed by Engineer-in-Charge.
Valve pit of size (1.2 x 1.2 x 1.2m) consisting of random rubble uncoursed stone masonary in cement mortar (1:6), 50 mm thick coping with PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) incl excavation and earth work and disposal of surplus soil to a distance not exc 50 mtr and depositing where directed by Engr-in-Charge, plastering internally with 15 mm thick in cement motor 1:6 and flush pointing externally in the same mortar as work proceeds and mild steel sheet cover (3.15 mm thick) angle iron frame of 40 x 40 x 6 mm handle locking arrengement and painting with two coats of synthetic enamel paint over a coat of red oxide primer on steel surface complete all as specified and directed by Engr-in-charge.
Stainless steel insulated water tank of capacity 500ltr including making connection with inlet, outlet pipes (rates also includes for fitting of nipple , socket or union required for connection including overflow pipe)
Stainless steel insulated water tank of capacity 5000ltr including making connection with inlet ,outlet pipes (rates also includes for fitting of nipple ,socket or union required for connection including overflow pipe)
Cast iron air release valve with single air outlet confirming to IS -14845 of size 50 mm bore including fitting complete all as specified and as directed
SCHEDULE `A' PART-VII (CENTRAL AIR HEATING SYSTEM AND COOLING WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only. Note for HEATING VENTILATION , AND AIR CONDITIONING:- (a) HVAC schedule given in tender is tentative for reference only . Contractor will submit his own design duly vetted by IIT/NIT .The capacity of plant and equipments will not be less than capacity indicated in Schedule “A”/BOQ , PS and drawing. (b) If design approved by IIT/ NIT require higher capacity, the same will be provided by the contractor and cost of the same is deemed to be included in rate quoted by the contractor in Schedule ‘A’/BOQ . NO deviation for higher capacity will be admissible on this account . Capacity of plant is deemed to be amended on higher capacity without any extra cost to the department which is required to the supply , installation , testing and commissioning of entire plant to achieve desired condition of temperature and humidity indicated in Sch “A”/BOQ & PS during outside conditions of peak summer, winter and monsoon respectively . (c) Capacity indicated in schedule or the higher capacity suggested by IIT / NIT shall be achieved , tested and guaranteed on ground at outlet /discharge side of equipments like hot Glycol Generator , chiller , pump , AHU, cooling tower etc by the contractor.
WATER COOLED CENTRIFUGAL CHILLER/SCROLL CHILLER Supply, Installation, Testing and Commissioning of ARI/Eurovent Certified 30 TR (Actual)Cooling capacity Water Cooled Centrifugal Chillers having hermetic/Semi hermetic/Open, single/multi stage Compressor 30TR cooling capacity , refrigerant/ fan cooled motor , Motor suitable for 415+ 10% volts, 50 Hz, 3 Phase Power Supply, Factory Fitted Unit , Microprocessor Based Control Panel, suitable for low GWP/ODP/Flammability/toxicity Refrigerant, Shell & Tube Insulated Evaporator, Shell & Tube Condenser, Electronic Expansion Device, Suitable Capacity Control Mechanism etc. Chilled Water Entering Temperature : 18 deg C Chilled Water Leaving Temperature : 6 deg C Evaporator Fouling Factor : 0.0001 MKS Condenser Water Entering Temperature : 32 deg C Condenser Water Leaving Temperature : 65 deg C Condenser Fouling Factor : 0.0002 MKS Refrigerant : low GWP/ODP/Flammability/toxicity Refrigerant Maximum Allowable IKW / TR @ 100% Load for water cooled cenrifugal /scroll chiller will be : 0.67 Maximum Allowable NPLV : 0.4 Scope of Supply for each chiller 1 No. 30 TR coolong capacity Centrifugal,scroll,screw, hermetic/Semi Hermatic/Open compressor complete with automatic capacity control, safety switches and controls etc. as per specifications. 1 No. - Suitable capacity air cooled induction motor with class 'F' insulation suitable for operation on 415+ 10% volts, 50Hz, A.C. supply. 1No. - Matching shell and tube water cooled condenser of M.S. shell and integrally finned copper tubes.
1No. - Matching flooded Type shell and tube chiller of MS shell & and copper tubes. 1 Lot- Refrigerant piping fittings, valves and accessories to interconnect compressor, condenser, chiller and electronic expansion valve. 1 Set- Microprocessor based control panel complete with accessories as per specifications. Lot- Refrigerant line accessories comprising of safety valves, angle valve, liquid line indications etc. Lot- Water flow switches at outlet of condenser and chiller, water drain and air purge valves where ever required. Lot- Suction line and chiller insulation with suitable thickness Croos linked XLPE insulation complete as required. Lot- Initial / first charge of refrigerant gas and compressor oil. Lot- Frame work for mounting the above condenser, chiller compressor and motor with base plate complete with anti-vibration pads/springs. Lot Interconnecting piping with valves duly insulated Victolic coupling for Pipes (Chiller/Condenser) connection Lot-RCC cement concrete foundation for the chiller unit(2 Working + 1 Standby)
Condenser Water Pumping System Supply,Installing, testing and commissioning of pumping system consisting of horizontal suction and delivery condenser water pump sets capable of delivering total 60 USGPM of water against 25 meter head and complete as per specification. The system shall comprise of the following: 2 No.-centrifugal pump with minimum 75% efficiency. 60 USGPM delivery at 25 M head suitable for parellel operation speed 1500 RPM 2 No. - Suitable HP TEFC squirrel cage induction motor with class 'F' insulation, 1500 rpm synchronous speed, operating on 415+ 10% volts, 3 phase, 50 Hz A.C. supply. Lot- Mounting frame with Antivibration pads. Lot Interconnecting piping with valves Lot-RCC cement concrete foundation for the pump unit(1 Working + 1 Standby)
Condenser Water Pumping System Supply,Installing, testing and commissioning of pumping system consisting of horizontal suction and delivery condenser water pump sets capable of delivering total 60 USGPM of water against 25 meter head and complete as per specification. The system shall comprise of the following: 2 No.-centrifugal pump with minimum 75% efficiency. 60 USGPM delivery at 25 M head suitable for parellel operation speed 1500 RPM 2 No. - Suitable HP TEFC squirrel cage induction motor with class 'F' insulation, 1500 rpm synchronous speed, operating on 415+ 10% volts, 3 phase, 50 Hz A.C. supply. Lot- Mounting frame with Antivibration pads. Lot Interconnecting piping with valves Lot-RCC cement concrete foundation for the pump unit(1 Working + 1 Standby)
Hot/Chilled liquid Pumping System Supply,Installing, testing and commissioning of pumping system consisting of horizontal suction and delivery Hot/Chilled liquid pump sets capable of delivering total 40 USGPM of water against 25 meter head and complete as per specification. The system shall comprise of the following: 2 No.- centrifugal pump with minimum 75% efficiency. 40 USGPM delivery at 25 M head suitable for parellel operation speed 1500 RPM 2 No. - Suitable HP TEFC squirrel cage induction motor with class 'F' insulation, 1500 rpm synchronous speed, operating on 415+ 10% volts, 3 phase, 50 Hz A.C. supply. Lot- XLPE insulation of suitable thickness duly cladded by aluminium sheets of 0.5mm thickness and properly clamped to pump as per specifications. Lot- Mounting frame with Anivibration pads. Lot Interconnecting piping with valves duly insulated Lot-RCC cement concrete foundation for the pump unit(1 Working + 1 Standby)
Cooling Tower 100 TR Combined heat rejection capacity Supplying, installation, testing and commissioning of FRP cooling tower of 100 TR heat rejection capacity each, in cell construction with FRP water basin, PVC fills with integral louvers and drift eliminators complete with hot water basin either fitted with spray nozzles or having self rotating sprinklers, statically and dynamically balanced axial flow type fan-direct driven or driven through reduction gear box with TEFC induction motor, suction screen, make up-quick fill arrangement, overflow and drain connections with necessary valves and suitable inspection ladder, access arrangement for cooling tower interior, cement concrete foundation, steel / masonry supporting structure, anti-vibration mountings, complete as per specifications and as required.
AIR HANDLING UNITS/AIR WASHER UNIT Supplying, installation, testing and commissioning of factory built floor mounted chilled water double skin type Air Handling Units/AIR WASHER UNIT made of 25mm thick panels consisting of G.I. Casing of thickness 0.8 mm outside layer and 0.8 mm inside layer with polyurethene foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower suitable for static pressure as detailed below, cooling coil section with machanically bonded aluminium finned copper tubes ( tube thickness not less than 0.5 mm ) cooling coil, filter section with pre filter 90% efficiencyand down to 10 micron, direct drive package with flame proof TEFC drive motor suitable for 415+10% volts, 50 Hz, 3 phase, A.C. supply, drain connections, with stainless steel drain pan duly insulated , and necessary vibration isolation arrangement etc. complete as per specifications and drawings of following capacities.
AHU 30TR, 6 ROW COIL, FILTER BANK1-MERV 7, FILTER BANK2- MERV 14, 7500 CFM SUPPLY AIR FAN, STATIC PRESSURE OF ALL FANS 65 MM OF WG
Air washer Unit RETURN AIR washer FAN 7500 CFM, STATIC PRESSURE OF ALL FANS 65 MM OF WG Motor and cabling/wiring should be flame proof type
PLUMBING WORK Chilled Water Circuit Piping Supply,installation,testing and commissioningof "C"class mild steel Chilled water piping with all necessary fittings like bends , tees,reducers,flanges,supports and duly insulated with Closed Cell FR-XLPE thickness.as per given below. The joints shall be sealed with 50 mm X 1 mm thick self adhesive tape complete as per specifications. 80 mm dia.(25 mm thick insulation) 1- Pipe outside the building shall be cladding with 0.5 mm thick aluminium sheet and per specification. 2- Pipe inside the building shall be covered with woven fiber glass fabric of 5 Mil thickness (140 Grams/Sq.Mtr.) and Coated with fire rated vapor barrier preferably epoxy resin or acrylic compound as per specification.
Valves Supply,installation,testing and commissioning of following PN-1.6 valves, stainers gauges in the chilled water piping duly insulated to the same specifications as the connecting piping and adequately supported as per specification and drawings . The chilled water circuit withall fittings and insulation with cladding as per the drawings and specifications.
Butterfly valve 80mm dia
Balancing valve 80mm dia
Check valve 100mm dia
Y Strainer 100mm dia
Y Strainer 80mm dia
Pressure Guage
Thermometer
Three-Way Modulating Valve Supply,Installing, testing and commissioning of complete control for AHUs comprising of a set of 3- way modulating proportional linear type valve having manual overried facility with Proportionate thermostate and wiring for interconnection with 1.5 sq.mm copper conductor multicore armoured cable suitable for Heating /Cooling complete as per specifications and as required. 80 mm dia for AHUs
Pressurized Chilled Water expansion Tank Supply,Installation, testing and commissioning of PRESSURISED CHILLED/hot WATER EXPANSION TANK suitable for total volume of water in chilled water circuits along with necessary accessories such as solenoid valve, safety valve, pressure switch with connection to chilled water header and pressurization unit The tank must be constructed in accordance with section VIII of the ASME Boiler and pressure vessel code and stamped 6 Kg /cm2 working pressure. The complete system shall be sourced from single manufacturer and supplied and installed with all accessories and safety fixtures required for proper functioning of the complete hydronic system.The Contractor shall calculate the total volume of water and determine the expansion tank capacity. Chilled water Expansion Tank suited for above application for proper functioning of the complete hydronic system. The total approximate Volume of water in chilled water circuit = 500 gallons and static head of approximate 25.0 mtr to be considered . The contractor shall submit calculations for total system volume Tank & accessories as above Lot - Mounting frame with Ant vibration pads Lot Interconnecting piping with valves duly insulated
Air Separator Installation, testing and commissioning of AIR SEPARATOR along with necessary accessories such same to prevent entrapment of air in the system. The separator must be constructed in accordance with Section VIII ASME boiler and pressure vessel. Air Separator Connection shall be suitable for 100 MM dai pipe. Air Separator as described above Lot -Mounting frame with Ant vibration pads Lot interconnecting piping with valves duly insulated
Drain Piping Supply,installation,testing and commissioning of GI B Class drain water piping on floor / ceiling of following size along with necessary clamps,fittings such as bends tees etc. and duly insulated with closed cell FR-XLPE thickness as per given below. The joint shall be sealed with 50 mm x1 mm thick self adhesive tape complete as per specifications. 25 mm dia (9 mm thick.)
Condenser Water Circuit Piping Supplying, fixing, testing and commissioning of 'C' Class mild steel condenser water piping with all necessary fittings like bends, tees ,reduces, flanges, supports as given below complete with vibration isolators as per specification. 100mm dia.
Valves Supplying, fixing, testing and commissioning of following PN - 1.6 valves,gauges and strainers for water circulation as per specifications. Supply,installation,testing and commissioning of following PN-1.6 valves,stainers gauges in the condenser water piping and adequately supported as per specification and drawings . The condenser water circuit withall fittings as per the drawings and specifications.
Butterfly Valve 100mm dia
POT Strainer 100mm dia
YStrainer 100mm dia
Pressure Gauge on all in coming and out going of chilled water and condensor water piping for Chiller, AHU Cooling coil etc
Thermometer on all in coming and out going of chilled water and condensor water piping for Chiller, AHU Cooling coil, Cooling Tower etc
DUCTING AND GRILLES Ducting work (for Air Conditioning) Supply, installation and testing of Factory / Site fabricated GI sheet metal ducts as per IS: 655 and IS:277 in accordance with the approved shop drawings and as required by the specifications.
24 Guage
22 Guage
20Guage
18 Guage
Duct Insulation Supply,installation,testing and commissioning of fire retardant insulation material of suitable thickness of thermal conductivity as per specification (Joint shall be sealed with self adhesive tape). Aluminum sheet wrapped 50 mm thick minimum.
Supply Air Grilles Supply, installation, testing and balancing of powder coated Extruded Aluminium supply air Grilles with volume control dampers in accordance with the approved shop drawings and specifications.
Return/Exhaust Air Grilles Supply, installation, testing and balancing of powder coated Extruded Aluminium Return/Exhaust air Grilles with volume control dampers in accordance with the approved shop drawings and specifications.
Fresh Air Grilles Supplying, fixing, testing and commissioning of power coated extruded aluminium section fresh air grill in weather maker room with aluminium volume control dampers, bird screen etc complete as required.
Fresh Air Intake/Exhaust Air Louvers Supply, installation, testing and balancing of Powder coated/Anodised extruded aluminium construction inlet air louvers with bird screen and volume damper for fresh air as per specifications and approved shop drawings.
Fire Dampers Supply, fixing, testing and commissioning of fire dampers in supply air ducts / main branch and return air path as & where required of required sizes including control wiring. The spring return action shall be built mechanism and not externally mounted. as per specifications of STEC no 22 as required. a) Fire damper
Power Cabling Supply, installtation testing and commissioning of complete cable work using XLPE insulated PVC sheathed steel tape/ wire armoured underground aluminium/copper conductor cables of following sizez for electric supply from main panel in AC plant room to various loads including Supplying and making end termination with brass double compression glads and aluminium lugs including interconnections from starters to motors on existing cable trays/supports as required as per specifications.
3.5 core x 25 Sqmm -copper armoured cable
3 core x 10 Sqmm -copper armoured cable
3 core x 6 Sqmm -copper armoured cable
3 core x 4 Sqmm -copper armoured cable
Control Cabling Supply,installation,testing and commissioning of complete cable work using PVC inulated PVC sheathed copper control cables of following sizes to various equipment including interconnections from electric supply to equipments on existing cable trays / supports as required including end termination on both sides as per specifications and as required. 6 Core X 1.5 Sqmm-Copper Cable
Cable Tray Fabrication and installation of following size of perforated GI cable tray, including horizontal and vertical bends reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders including painted etc.as required.
300 mm W x 1.6 mm thick
150 mm W x 1.6 mm thick
Earthing
Providing & fixing 6 SWG dia. GI wire on surface or in rececess for loop earthing complete as required.
Providing & fixing 25mmx5mm GI strip on surface or in rececess for earth connections etc complete as required
Supply, Installation ,commissioning and testing of complete in all respect central air heating system and cooling system including boiler unit, chiller unit, AHU, Pipe line etc as per design conditions mentioned below :- (A) Supply, Installation, commissioning and testing of Central Air Heating plant using oil fired glycol based hot water generator using HSD oil pressurized type 3 Pass reverse flame horizontal smoke TubeTwo numbers hot water boiler of not less than 3,00,000 K Cal/Hr each complete to meet the required condition of temp and humidity criteria for building complete in all respect, with combustion chamber and equipment automatic monoblock burner assy, fire tubes, control panel with /sequence controller, photo cell for frame failour, HT transfer electrode blower assy electric panel, mounting frames, pressure guage at inlet and outlet for suitable operation on 50 Hz three/single phase AC supply complete in all respect including following item of work. Make: Thermax, Ecoflame, Western,Rapidtherm, Alphatherm Note :- (I) The boiler shall be installed in system of (1W+1 S) (III) The tenderer should get the plant installed by any of the original equipment manufacturer with recommended makes of compatible components of items. (IV) The boiler minimum specification should be as under: (i) The boiler inner shall be made from min 8mm thick carbon steel with dish end (curve type) (ii)Outer shell made from min 6mm thick carbon steel. iii) Boiler tube shall be made from 50 mm dia min 3.66mm thick seamless MS Tube (boiler quality) (iv) The front door shall be openable lined with high grade insulation and refactory
(v)High efficient, low noise imported monoblock burner (Benton/Rello) (vi)The boiler shall be insulated with 50mm thick resin bonded fibre glass wool and cladded with 22 guage GI sheet (epoxy pointed) (vii)Pre wired control panel (made from 18 guage CRC sheet ) Main incomer, MCB in/out temperature controller (digital)fault indicating light for water high temp, burner trip,flue temp, with alarm, hour meter for maint schedule etc. (viii) 1 set of oil piping from unit to burner . (ix) including suitable concrete foundation of boiler (a)Heater unit:-Heat exchanger ,consisting of closely wound, helical concentric coils, arranged to give adequate no. of passes on flue gas side & made out of ERW tubes confirming to IS 3059 Pt-I suitable for high temperature all as per manufacturer design and of required head and capacity . (b) Pressure jet burner:-Suitable for light oil firing with stepless modulation mechanism all as per manufacturer design and of required head and capacity. (c) Combustion air fan with drive motor assembly all as per manufacturer design and of required head and capacity. (d) Control Panel : Dust protected pre-wired unit mounted air cooled control panel housing a burner management system , switchgear consisting of contractors, overload relays, fuses and MCB etc.all as per manufacturer design and of required capacity. ( B) Design,supply, installation and erection of Chimney 10 mtr height chimney above bldg roof made out of min 3 mm thick MS sheet including flue gas duct all as per recommendation of manufacturer of Central Air Heating plant of above refered item. Qty - 02 Nos (separate for each Boiler) ( C) Design ,supply and Installation of Glycol storage tank of capacity of 2000 ltr made out of 5mm thick MS sheet complete all as specified and as directed. Qty - 02 Nos ( D) Design ,supply and Installation of diesel fuel storage tank of capacity of 1000 ltr made out of 5mm thick MS sheet complete all as specified and as directed. Qty - 01 Nos
Day oil storage tank:-Supply installation testing and commissioning of HS OIL Day storage tank rectangular mild steel IS 2062 construction with capacity of 2000 ltr complete with inlet outlet overflow,drain vent withflame arrester.Tank shall be made out of 4mm thick MS sheet & will be provided with supports made out of minimum 50mm dia medium grade pipe to keep tank base at minimum 2500mm above finished floor level.The tank shall be provided with level switches for on/off operation of transfer pump. Extra high level and low level alarm shall be provided alongwith gauge indicator duly calibrated.Tank and structure shall be painted with two coats with synthetic enamelled paint of approved colour over one coat of primer complete allas specified.
Transfer gear oil pump fuel(self priming)-Supply installation testing and commissioning of self primimng rotary gear transfer pumps of capacity 15 LPM 10 m head for kerosene or HSD oil complete with base mounting frame.PCC foundation including holding down bolts,coupling guard and TEFC flame proof motor 2 HP and other accessories required for commissioning etc complete all as specified and directed.
Glycol based water fluid tank:-Supply & installation 2000 ltr capacity MS tank madeout of 3mm thick mild steel cylindrical/rectangular with removable lid in/out/drain/overflow system mounting arrangement making connection etc complete all as specified and directed ISI marked.
Total amount of Sch 'A' part-VIII(ROAD/HARDSTANDING /CULVERT/CAUSE WAY WORK)
Total amount of Sch 'A' part-IX (LIGHTENING PROTECTION WORK)
Total amount of Sch 'A' part-X(SEC-I)(SEWAGE DISPOSAL WORK)
Sch 'A' Part-X(SEC-II) (SEWAGE DISPOSAL WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
LLDPE septic tank for 25 users .design to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc. complete, all as directed by Engr-in-charge.
Total amount of Sch 'A' part-XI (AREA DRAINAGE WORK)
Total amount of Sch 'A' part-XII (PROTECTIVE WORK)
Total amount of Sch 'A' part-XIII (STEEL GATE WORK)
Total amount of Sch 'A' part-XIV (FIRE ALARM WORK)
Total amount of Sch 'A' part-XV (HOT WATER SUPPLY WORK)
Sch 'A' Part-XVI (FLAME PROOF EOT CRANE WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Design, supply, installation, testing and commisioning of 2 Ton capacity flame proof EOT crane, electrically operated through pendant push button station floor operated type having hoisting height of 3 meters approximately, single girder box type complete with and including main frame, crab, buffers, gears with gear boxes, shafts, rope drum, rope sheaves, wire rope, wheels, lifting hook, brakes, motors, limit switches, control panel, pendant push button station, micro speed arrangements, wiring etc. IS-3177 and IS-807 all as specified below:- (a) Capacity 2.0 Tons (b) Cross Span 12 m approximately (c) Long Span 10 m approximately (d) Hoist lift 3m approximately (e) Hoisting Speed 3m/min approximately (f) Hoisting motor 2 HP, 4Pole, Flame proof (g) Cross travel motor 0.5 HP, Flame proof (h) Long travel motor 0.5HPx2Nos , Flame proof (i) Operation pendant Push button from floor (j) Class of duty - II (indoor) Mechanical work: (i) Gantry Girder having Length 10 Mtr ( Approx ) Both side . (ii) Gantry Girder ISMB-200 X 100 + 40MM Square Bar With Suitable Joint plate . Span-12 Mtr Hoisting Girder (As per Manufacturer's design). (iii) Electric Hoist Cap-2 Ton , Up-Down ,Left Right ( Six Way Motion)
Sch 'A' Part-XVII (TEMPERATURE & HUMIDITY MONITORING LOGGER WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply and installation of automated wireless online temperature and humidity monitoring and recording logger for real time monitoring of temp and humidity of storage bins complete comprising of following specifications:- Temperature and Humidity sensor (a) Temperature range is -40°C to 120°C with accuracy of ±0.5° C (b) Relative Humidity range is 0 to 100% RH with accuracy of ±2%RH. (c) Highly accurate digital technology sensors (d) Flameproof model with password protection. (e) Optional range Lock set Points can be configured. (f) Non-Intrusive Programming for flame proof/models using magnetic Pens. (g) Error Monitoring on sensor break/open (h) 2 Lines 4 digit 13mm (H) seven segment display (i) Power consumption less than 3.5 watt Other Accessories (a) Data transmitter and receiver with antenna ( with web view) (b) Rack for Data scanner (c) Supply for Data scanner (d) Cat 6 Cable/4Core sheilded cable/ networking switch (e) UPS double battery for back up (f) Software for Data analysis and reporting (g) Intelligent data Logging panel with data storage and local web facility, display and utility to download data from software, can be connected to AFNET for remote viewing at any place without software in web browser , with alarm system.
Sch 'A' Part-XVIII (SPECIAL ITEMS WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
The bullet proof morchas as shown on drawing no. CEAF/TD-148/2019 sheet 1/1 consists of steel/iron plates with firing slots & joined together with hinges for assembling and dismantling and it should be easily movable. (a) Dimension -Thickness of sheet - 10mm, Heigth - 1900mm or more, length & Width - 1680 mm (b) Firing Slot - Each plate to have a sliding firing slot to have bullet proof steel sliding cover. (c) Protection Level - It should provide protection against the amn fired from SLR/AK-47/LMG from a distance of 10 meters, (d) Handling- Handles on each plate to carry the plates and locking arrangement. (e) Colour - Two coats of synthetic enamel paint in Camouflage pattern over a coat of pink/red oxide primer on steel surfaces. (f) Certificate - A certificate of "Protection by any authorized government agency/ Lab etc.
Rifle rack suitable for 03 rifles and grouting in floor with suitable size of nuts and bolts complete all as specified and directed by Engr in charge.
Amunition box of size 2x1x1 feet made of 3mm thick sheet of MS steel and bolted with angle iron frame 50x50x6mm and grounting in floor with suitable size of nuts and bolts and painting the box with painting two coat of enamal paint and one coat of red oxide primer complete all as specified and directed by Engr in charge.
Total amount of Sch 'A' part-XIX(Sec-I)(FENCING WORK)
Sch 'A' Part-XIX(Sec II) (FENCING WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.idder shall insert their rates in Green filed under Col-6.
Cross spiral concertina coil 1000mm dia, made up of 2.60mm HTSG spring core wire having tensile strength of 1600 N/Sqmm and punched tape of 0.5mm thick and 13mm wide after crimming. Punched tape shall be of hot dipped galvanised min 20 micron and having medium barbs of 24mm width @ 35mm centre to centre each concertina coil shall be of min 50 turn and 5 clip in two turns i.e. 125 clip per coil (weight of coil 14 kg to be stretched upto 4.5 RM i.e. 3.11 kgs per RM) complete all as specified.
Total amount of Sch 'A' part-XX(SITE CLEARANCE,EXCAVATION AND EARTH WORK )
Sch 'A' Part-XXI (MANNING AND OPERATION OF E/M INSTALLATION) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.idder shall insert their rates in Green filed under Col-6.
Outsourcing of services for Manning & operation of E/M installation round the clock (i.e 24 hrs in three shift) with one shift of 8 hrs having one FGM in each shift comprising of following installation: (a) DG Set 200 KVA - 02 Nos (1W+1S) (b) Glycol Based HSD oil fired boiler of capacity 100000 K Cal/hr with combustion chamber, automatic monoblock burner assembly, fire tubes, control panel with sequence controller, photo cell, pressure gauge , Heat transfer electrode blower assy electric panel , circulating pumps, fuel pump, Derator cum expansion tank etc-03 Nos (2W+IS) (c) Air cooled Scroll Chiller of Capacity 15TR with multi compressor, Semi Hermetic sealed compressors , chiller, air cooled condensers, expansion device with all auxiliary equipment including cooling tower -03 Nos (2W+1S) (d) Monoblock centrifugal chilled water pump 2HP capacity -03 Nos (2W+ 1S) (e) Double skinned horizontal floor mounted AHU including all connected accessories-02 Nos ( One for heating and one for cooling) Note:-(i) After completion of work under Phase-I , the work of manning and operation under defect liability period as catered under Sch ‘A’ part-XXI for 24 months will be carried out. (ii) T&P for general maintenance like spanner sets, plier, test lamp, emergency lights and safety items like LT hand gloves, tools etc are to be provided by contractor. (iii) Contractor should provide complete uniform to Operator mentioning operator Name & Firm Name (iv) The FGM employed by the contractor must be duly Govt ITI qualified having minimum 2 years experience/ a person having 7 years experience in the relevant trade/Ex-Servicemen in relevant trade.Contractor shall submit educaton qualification certificate / experience certificate foe app[roval of GE before employing them. CONTD..
(v) Fuel (DHPP(N) /DHPP(A) shall be supplied by the department free for filling/use.All other FOL/Lubricants, filters and other accessories , top-up filling, refrigerator gas , compression oil etc shall be arranged by contractor at his own arrangements and cost. (vi) FGM/Operator will maintain a log book and connected documents of all the installation to record all the electrical parameters daily and put it to concerned JE/AGE for checking on weekly basis. (vii) Any damage to the installation due to poor workmanship and negligence of the operator will be borne by the contractor. (viii) The contractor shall pay the minimum wages as fixed by Asstt Labour Commissioner, Leh , UT ladakh whichever is higher. (ix) GE will ensure that contractor will not employ the FGM Continuous after 11 month in the contract. (x) A panel recovery of @ Rs 1000/-per shift per operator shall be recovered in case of operator found absent from duty. (xi)Sufficients spare parts to be kept ready in functional condition and shall be available at site. In case of any breakdown same is to be rectified and made functional within 48 hrs failing which recovery @ Rs 1500 per day will be made. (xii) All Spare/ parts required for running /operation and also maintanance during entire period of defect liability will be borne by contractor , the rates quoted by the contractor shall deem to include the cost of the same and nothing extra shall be admissible on this account . (xiii) Reimbursement/refund on variation in prices as catered under special condition no 42 shall not be applicable for the work catered under this schedule ie for the work of manning and operation covered under Sch ‘A’ Part-XXI.
J.D.Builders
D S constructions
VED PRAKASH GUPTA
M/s V6 Infrastructures Pvt. Ltd.
M/s Ravinder Kapoor Engineers and Builders
GOYALA INFRA PROJECTS PVT LTD.
Sood Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid