Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC HOUSE NO 2 SATGAON MAIN ROAD NEAR BAILEY WATER FACTORY P O UDAYAN VIHAR DIST KAMRUP METRO GUWAHATI ASSAM 781171 | GUWAHATI | KAMRUP METRO | ASSAM | 781171 | ₹33.5 L Quoted ₹34.0 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹36.9 L+₹2.9 L (8.65%)Rejected-Finance | ₹36.9 L+₹2.9 L (8.65%) | L2 | Rejected-Finance Other than Lowest Bidder |
| 3 | L3₹37.0 L+₹3.0 L (8.70%)Rejected-Finance H NO 18 BY LANE NO 09 SATGAON PRAGATI NAGAR GUWAHATI ASSAM 781171 | KAMRUP METRO | ASSAM | 781171 | ₹37.0 L+₹3.0 L (8.70%) | L3 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹38.5 L
EMD Value
₹76,900
Closing Date
15 Mar 2022, 6:00 pmClosed
GE Narangi
GE Narangi C/O 99 APO
PROVN OF TOILET WITH SANITARY FITTINGS AND PLUMBING WORK TOILET FOR GUARD ROOM AND CONSTN AND REPAIR OF INTERNAL DRAINS INCLUDING SLOPE CORRECTION UNDER GE NARANGI
2021_MES_484131_3
8698/B/E8
Open Tender
Civil Works
Item Rate
180 days
GE Narangi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Narangi
₹76,900
Yes
9 Apr 2022
16 Feb 2022
18 Mar 2022
16 Feb 2022
15 Mar 2022
2 Mar 2022
Amount
M&L Excavating over areas not exceeding 1.5 metre deep and getting out in soft/loose soil complete all as specified and directed.
M&L Excavating over areas exceeding 1.5 metre or part thereof deep beyond the first 1.50m and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation or for shafts, wells cesspits,man holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed.
All as per item no 3 above but depth exceeding 1.50m and not exceeding 3.00 m complete al as specified and directed.
Returning, filling, in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and as directed.
Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed.
M&L for loose filling with broken brick aggregate of gauge 80 to 150mm in soakage pits, soakage wells complete all as specified and as directed.
M&L for moorum/red bajri filling in floors or pavings deposited, laid in layers n exc. 15 cm thick,spread , levelled and rammed including watering complete all as specified and as directed.
M&L for hardcore of broken or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface etc complete all as specified and as directed.
M&L for PCC 1:3:6, typeC2 (using 40mm graded stone aggregate) as in surface channel and drains complete all as specified and as directed.
M&L for PCC 1:2:4, type C1 (using 20mm graded stone aggregate) as in roof kerbs or mud stops round or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
M&L for PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed.
M&L for PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed.
M & L Precast RCC1:2:4 Type B-1 ( Using 20mm graded stone aggregate) as in landings, cover slabs ( for manhole etc) chullah hoods, chajjas , water toughs, mangers, shelves and similar articles with plain faces complete all as specified and directed.
M&L for reinforced cement concrete M-25 design mix as in foundations, including rafts, footings, foundation beams; plinth beams bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for reinforced cement concrete M-25 design mix as in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for reinforced cement concrete M-25 design mix as in beams, seimic bands, cantilevers, bressumers and lintels complete all as specified as directed.
M&L for reinforced cement concrete M-25 design mix as in slabs supported on walls , beams and columns in floors, roofs, landings, balconies, casnopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for reinforced cement concrete M-25 design mix as in chajjahs complete all as specified as directed.
M&L for reinforced cement concrete M-25 design mix as in walls, retaining walls, basement walls, ballast walls, and the like any thickness above top of footings including attached pilasters and buttresses complete all as specified and directed.
M&L for Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces complete all as specified and directed.
M&L formwork to sides and soffits of floor or roof beams, beams haunchings, girders, bressumers, lintels over 1.5m clear span, cantilevers, shelves including supports overhangs etc also splays between floors and beams etc. for fair finished flat surfaces of concrete complete all as specified and as directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar works, not exceeding 200mm thick ( Horizontal or sloping) complete all as specified and directed.
Cutting chases in brick masonry walls built in cement mortor for concealed water tubing or concealed conduit wiring, etc., and making good in CM 1:3, cutting not exc 10 cm girth etc complete all as specified as directed.
M & L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia as in reinforcement bar complete all as specified and as directed.
M & L for mild steel TMT bars 6 to 8mm mm dia and over cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia as in reinforcement bar complete all as specified and as directed.
M&L for mild steel TMT bars 6 mm dia and over upto and including 10mm dia cut to length, bent to shape required including cutting, cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and as directed.
S&FMild steel framed work such as grills,gratings,etc.with ends of bars shouldered and/or riveted,or forged into spikes,framed guard bars, barred iron doors,ladders, framed balusters, walk ways,railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165.
Demolition of brick /stone massonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L brick work with sub class ‘B’ bricks (locally available best quality) in one brick thick honey comb walling built in cement mortar (1:4) complete all as specified and directed.
M&L brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius built in cement mortar (1:4) complete all as specified and directed.
M&L brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
All as per item No. 34 above but except bricks. (Serviceable bricks obtained from demolition shall be reused).
M&L brick work with sub class ‘B’ bricks (locally available best quality) laid flat , in floors laid dry and pointed in cement mortar 1:3 on side of drain wall complete all as specified and directed.
All as per item No. 36 above but except bricks. (Serviceable bricks obtained from demolition shall be reused).
M&L for keyed pointing to brick walls in cement mortar 1:4 complete all as specified and directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Demolition of cement concrete in ground floors and paving not exceeding 15cm thickness (below or above ground level) including removal of spoils/ demolished materials not exceeding 50m and depositing complete all as specified and directed.
M & L for 25mm thick PCC 1:2:4, type B1 (using 20mm graded stone aggregate) as in floor to receive top layer complete all as specified and as directed.
M&L for 75mm thick PCC type D-2, 1:4:8 (40mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for providing 75 mm thick PCC (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) as in plinth protection. Plinth protection shall be laid in alternate bays n exc 2 sqm, 10 mm thick joints shall be provided, joint shall be filled with bitumen mastic, bitumen mastic shall comprises of 1 part of hot bitumen 85/25 and 3 parts of sand all by weight finished cement concrete surface even and fair without using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick in CM (1:3) on concrete surfaces of roof mixed with WPC as per manufacturer,s instruction complete all as specified and directed. Note : WPC will be measured and paid seperately.
M&L for rendering 5 mm thick in CM (1:3) on concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10 mm thick in CM (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:4), in two layers, to fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound (@ 3% by weight of cement or as per manufacture's instructions), finished even and smooth without using extra cement complete all as specifed and directed. (Note : Water proofing compound to be measured and paid separately as "Supply only")
Supply only integral water proofing compound complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying a coat of wall care putty of 1mm average thickness and sanding the surface till smooth finish surface is obtained and a coat of alkali resistant primer and two coats of oil bound distemper complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of new plastered surface of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surface of wall and applying three coats of white wash complete all as specified and directed.
S&F steel windows and ventilators fixed type complete with glazing bars dovetailed or welded complete all as specified & as directed.
S&F steel ventilators with top hung shutters including hinges , steel peg stay complete all as specified & as directed .
S&F PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (stile) consisting of frame made out of MS tube for top and bottom rails, MS frames shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stills and plain colour PVC sheet top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/ scaled to the stiles and rails with suitable PVC Sheet beading and jointed together with solvent cement as per drawings and specifications as catered in SSR Part – II 2020.
S&F 100mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 150mm in size extruded aluminium handles, fabricated type, anodised complete all as specified and directed.
S&F 100mm in size extruded aluminium handles, fabricated type, anodised complete all as specified and directed.
S&F stainless steel butt hinges 100 mm long medium weight complete all as directed.
S&F, stain-less steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless wire staples complete all as specified and as directed.
S&F 4mm thick frosted glass, ordinary quality and glazing with oil putty in square not exceeding 0.50 sqm in each pane complete all as specified and directed.
S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.50 sqm in each pane complete all as specified and directed.
M&L for glazed ceramic coloured joint free tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick with and including 10mm thick CM 1:4 backing coat, set and jointed in neat cement slurry and pointed in white or colour cement to match etc complete all as directed.
M&L coloured Non-skid ceramic tiles 7 mm thick (Square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match existing surfaces over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel and steel based surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
S&F GI tubing15 mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S & F GI tubing 20mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S&F stop valves 15 mm dia cast copper alloy, fancy type chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and directed.
S&F stop valves/ angular stop valve, 15mm dia, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and as directe.
S&F 20mm bore gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe etc complete all as specified and as directed.
S&F Bib taps 15mm dia fancy type cast copper alloy chromium plated, with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as directed.
S&F 15mm bore pillar taps cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.
S&F 1000 litres capacity rotational moulded polye-thylene water storage tanks triple layer ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I with and including 20 mm bore dia -ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and directed.
S&F 20mm bore ball brass valves, high pressure, with polyethylene float and fly nut complete, screwed for iron pipe gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe etc complete all as specified.
S & F Vitreous China Squatting Pan"Orissa pattern" size 580 mmx440 mm white with integral foot rest etc. ( excluding cistern and flush pipe) including S or P Trap and provision of concrete bedding and making good to floor complete all as specified and as directed.
S&F PVC low level flushing cistern 10 litres capacity with inlet ball valve, float and handles including brackets complete all as specified and directed.
S&F fancy type soap dish chromium plated fixed to wall with chromium plated brass screws and plastic cleats complete all as specified and as directed.
S&F vitreous china wash basin white flat back size 550 mm x 400mm including all fittings and CP Pillar tap, including cutting for and pinning in ends of brackets or erecting stand etc complete (waste coupling 32mm bore CP, 32mm bore PVC waste pipe, cast iron brackets etc shall be deemed to be included in the quoted rate) complete all as specified and directed.
S & F Brass chromium plated tubular towel rail, 20mm dia D type 60cm long between flanges with brass chromium plated brackets complete all as specified & as directed.
S & F Sheet glass shelf assembly consisting 5.5mm thick sheet glass shelf 12cm wide with aluminium alloy bracket guard and railing 60cm long all as specified and as directed.
S&F CP swivel shower rose of 125 mm dia and suitable for fixing 15 mm bore iron pipe all as specified and directed.
S&F 15mm dia PVC connection pipe 600mmm with PTMTnuts complete all as specified and directed.
S&F cast iron floor trap with 100mm dia outlet with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 complete all as specified and directed.
S&F cast iron floor trap with 75mm dia outlet with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 complete all as specified and directed.
S&F vitreous china bowl, urinal flat back, size of 465X 355 X 265 mm white ( minimum) with grating and union for discharge pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement etc. complete all as specified and directed.
S&F Vitreous china urinal,partition white of size 310mmX700mm fixing with screws and washers including filling with white cement and coloured pigment to match the shade of existing surface complete all as specified and directed.
S&F Vitreous china urinal, half stall white (excluding flushing cisterrn) including urinal spreader, PVC connection, 40mm PVC waste pipe & 40mm waste coupling providing and fixing plugs, bedding urinal against wall in mortar 1:2, securing urinal to plug, with and including 60mm long screws, pointing around urinal back in cement, fixing flush pipe, grating and union for discharge pipe complete all as specified and directed.
S&F 110 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F 110 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or in floor as in waste/soil pipe etc complete all as specified and directed.
S&F 150 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or in floor complete all as specified and directed.
M/L PCC 1:3:6 type C-2 ( 40mm graded aggregate) as in concrete bed to drain pipe 150 mm dia including packing under , and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
S&F 110 mm dia PVC (SWR) bends of any radius complete all as specified and directed.
S&F 110 mm dia PVC (SWR) vent cowl complete all as specified and directed.
S&F PVC (SWR) door junction single, (Double T) equal or unequal of 75mm dia bore complete all as specified and directed.
M & L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm cable (including connecting to earth dolly) laid/fixed in and including concealed in PVC rigid conduit on walls/ceiling, and also including sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers for One light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
All as per item No 99 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board.
All as per item serial No 99 here-in-before but for One 3 pin 5 Amp socket outlet on same board with other switches.
All as per item No 99 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.
S&F switch piano, flush type single pole one way 5 Amps 240 volt complete all as directed.
S&F socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as directed.
S&F switch socket combination outlet , 2-in-1, 5 Amp flush type complete all as directed.
S&F switch socket combination multipurpose, 5 in 1, , 5 & 16 Amp flush type complete all as directed.
S&F ceiling rose surface bakelite 65x50mm three terminal complete all as directed.
S&F lamp holder insulated PVC/ Polycarbonate/ bakelite body, with back plate suitable for batten fitting or PVC round or squre box, complete all as directed.
S&F Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagonal bulk head black-lit LED10 W -IP-66 luminaire comprising of high brightness LEDs complete all as specified and as directed. Make:- Havells Model HEXAFT10WLED857SSYMBOPC or equivalent Model of make : Philips / Crompton /GE.
S&F stepped type electronic fan regulator, two module size, flush type complete all as directed.
S&Fin repair regal batten for LED Tube rod pre-wired including LED tube double sided 1x20W connecting up with aluminium housing and sheathed 1100 volt grade flexible copper cable & fix on 2 no. of PVC block complete all as directed. (Make:- Havells, Model No: REGALBATTENT8UPTO1X22WDSBSWH+CRSTAL1213T8DSTL20WLED865SGLASS or equivalent model of make Bajaj / Philips / GE / Crompton)
S&FLED street light fitting 35 Watt 230 Volt AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, IP 65/66 protection class complete. Make: Havells/ Philips /GE/Crompton)
Supply and fixing building security light bracket made of GI pipe 40 mm bore medium grade (bend to shape), 2.00 metre long and fixed with Ms flat iron clamp(clamp shall be 40 x 5mm), nuts, bolts and washers on pole complete all as specified and directed.
Supply and fixing building security liminaires WSPD 48 Watts epoxy powder coated pressure die cast aluminium housing with weather proof gasket for LEDs and control gear compartments, pressure die cast aluminium frame with heat resistant toughened clear glass fixed with SS screws. CRee LED/Equivalent colour temp-5700 K +/-300 K lens , IP-66, lumen efficiancy >100, lm/w. surge protection, 4 KV internal ( built in) with twin core conductor complete all as specified and directed including testing on completeion. Make: Havells Cat No. ENDURAPEARNEOSL48WLED757SASYTOPC or equivalent in Philips/WIPRO/CG.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrode at one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm bore GI pipe medium grade with all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I including demolition of old earthing complete all as specified and directed.
S&F exhaust fan with louvers shutter 230V, 50 Hz, metal body, 300mm sweep copper winding and necessary connecting items with flexiable PVC insulated multistranded copper conductor cable of size 1.5 sqmm and making good to the disturbed surfaces complete all as specified and directed.
S&F Ceiling fan with blades, down rod, electronic regulator and accessories 230 V 1200mm sweep with minimum air delivery 210 CFM with service value 6.00 BEE five star rated with bushless direct current motor ( BLDC) complete all as specified and directed. Make : Usha/Orient/ Havells
S&F MCB DB, double door sheet metal enclosure SPN 8 way with 200 A rated bus bar complete and grouted in wall with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
S&F MCB DB, double door sheet metal enclosure SPN 4 way with 200 A rated bus bar complete and grouted in wall with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
S&F MCBs, SP 6 to 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA, C-series marked fixing in DBs (DBs catered separately in this Schedule) (Make :- Legrand/ Siemens/Schnider/L&T)
S&F MCBs, SPN 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA ,C-series complete all as specified and directed. (Make :- Legrand/ Siemens/Schnider/L&T)
M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 10 sqmm 2 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
Supply and spreading clean dry river sand in cable trenches as in cable cushioning complete all as specified and as directed. (Note: Punned thickness shall be measured and paid)
M&L for Sub class ‘B’ old size well burnt brick laid flat in trenches over the cable for protection of LT cable complete all as specified and as directed.
M/S M Ahmed and Co.
SHANKAR ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .