Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹10.4 L+₹2.1 L (24.7%)Rejected-AOC | L2 | Rejected-AOC OK | |
| 3 | Rejected-Technical HOUSE NO 22 BHAGADUTTAPUR BELTOLA RUKMINIGAON ROAD GUWAHATI 781028 | KAMRUP METRO | ASSAM | 781028 | - | Rejected-Technical does not have appropriate c(i) category | |
| 4 | Rejected-Technical | - | Rejected-Technical does not have appropriate c(i) category | |
| 5 | Rejected-Technical | - | Rejected-Technical does not have appropriate c(i) category |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
26 Aug 2021, 6:00 pmClosed
AGE (I) AF Digaru
AGE (I) AF Digaru PO Digaru Dist Kamrup Assam 782401
REPAIR / MAINTENANCE / SERVICING OF AC UNITS, COMPRESSOR, EVAPORATOR, BLOWER, THROTTLING, FAN, PCB, GAS REFILL AND OTHER MISC WORKS AT AF STN DIGARU
2021_MES_458890_2
8485/E8 of 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Digaru
MES contractor enlisted as class E cat c(i) having deposited standing security of Rs 24000 with dept.
5 documents required · 5 mandatory
₹500
Yes
AGE (I) AF Digaru
₹16,000
Yes
16 Oct 2021
12 Aug 2021
28 Aug 2021
12 Aug 2021
26 Aug 2021
21 Aug 2021
Amount
Taking down unserviceable Window/Split Air Conditioner of any capacity make by un-screwing from base plate after disconnecting all electrical and suction / discharge pipe connections complete and makinf necessary repairs as required like fixing new compressor (sealed unit) and providing all electrical connections to respective terminals including changing of unserviceable connecting wires as per the existing. Brazing of suction and discharge lines with new compressor and vacuuming the system and testing / rectification of leakage, fixing cooling coil, supply and charging of refrigerant gas as per requirement to achieve proper cooling effect and testing on completion complete all as specified and as directed. Note: (i) Compressor (sealed unit), cooling coil shall be measured and paid separately. (ii) Gas and Parts required for replacement for satisfactory repair shall be paid and measured separately.
S&F in replacement of Copper Pancake Coil Nitrile Foam Insulation Tube, Class 1, Inner Diameter - 1/2 Inch (12.7mm) & Wall Thickness - 6 mm, Pack of 1 Pcs of 2 m length for suction and discharge line copper tubing for split type AC 1.5/2 ton capacity complete all as specified and directed.
S & F in replacement filter of split/window type AC (1.5 / 2.0 ton) complete all as specified and directed.
S&F in replacement of Copper Tubing of suitable size1/2"and 3/4" for suction and discharge line two run for split type AC with insulation to protect the heat etc complete all as directed.
S&F in replacement of cooling/condenser coil copper with aluminium fins for outdoor unit of split type AC suitable for 1.5/2 ton etc complete as as directed.
S&F in replacement of air cooling/evaporator coil copper with aluminium fins for indoor unit of split type AC suitable for 1.5/2 ton etc complete as as directed.
S&F in replacement of Master PCB suitable for both window and split AC alongwith remote control with remote control, 5 working mode, 3 fan speed, temperature control, auto fan, timer, sleep, double sensor, auto restart, transformer connection complete 220V, 50Hz complete all as specified and directed.
S&F connection lead two single core,with PVC insulated and sheathed Copper cable size 2.5 Sqmm including earth wire complete all as specified and directed. Make: Finolex/ Havels/ Plaza/ RR Cable/ Richa.
M&L for unplasticised PVC pipe of pressure rating 10 Kg/Cm2 fixed complete to walls,ceilings or in floors etc, size 15mm dia (outer dia) including chase cutting on wall & making good as per existing complete all as specified and directed.
M&L for two single core FRLS PVC insulated multi stranded copper conductor cable 4 Sqmm including rigid heavy duty PVC conduit size 25 mm dia in Existing surface including all accessories along with 2.5 Sq mm PVC insulated copper standard conductor earth wire connected to main wring system complete all as specified and directed. Make: Finolex/ Havels/ Plaza/ RR Cable/ Richa.
M&L for Gas Charging of Split type A/C and Window type AC capacity of 1.5/2 TR including necessary R-22/134/320/ suitable gas, filter, anti moisturising agent, soldering/brazing, necessary copper suitable TR capillary tube any size and testing complete. (Refrigrant gas will be measured with this items rate).
Supply only Compressor ( Sealed unit ) suitable for Window type AC 1.5 TR (3 Star / 5 Star). Make: Kirloskar / Blue star/ Voltas/ Carrier/ Samsung.
Supply only of Compressor (Sealed unit) suitable for Spli type AC 1.5 TR (3 Star / 5 Star). Make: Kirloskar / Blue star/ Voltas/ Carrier/ Samsung.
Supply and replacement of Compressor (Sealed unit) suitable for Spli type AC 2 TR (3 star / 5 Star). Make: Kirloskar / Blue star/ Voltas/ Carrier/ Samsung.
S/F for Single pole Sheet metal enclosure with socket plug top and MCBs.
S/F for Capacitor 36 MFD for window / Split type AC 1.5 TR.
S/F for Capacitor 40/45 MFD for window / Split type AC 2 TR.
M&L for shifting of split AC unit including dismantling of indoor and outdoor unit and mounting arrangement and refixing in new location by fixing mounting arrangement, topping up gas complete all as specified and directed.
M/s Ravi Enterprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .