| 1 | L1₹34.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹36.6 L+₹1.2 L (3.34%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹40.1 L+₹4.6 L (13.1%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹41.0 L+₹5.6 L (15.8%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹41.4 L+₹5.9 L (16.7%)Rejected-Finance 11 1 7 P D KYDGANJ PRAYAGRAJ U P PIN 211003 | PRAYAGRAJ | UTTAR PRADESH | 211003 | L5 | Rejected-Finance Being L5 |
Tender Value
₹44.9 L
EMD Value
₹90,000
Closing Date
25 Jan 2023, 6:00 pmClosed
Garrison Engineer (East) Allahabad
Stanley Road, Teliyarganj, Allahabad
REPAIR OF COMPOUND WALL, SECURITY WALL, DRAIN, PATH, FENCING AND CLEANING OF SEWAGE LINE OF MANHOLES PIPE LINE ETC AT VARANASI CANTT UNDER GE (EAST) ALLAHABAD.
2022_MES_572414_1
8610/E8
Open Tender
Civil Works
Item Rate
270 days
Varanasi
As Per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (East) Allahabad
₹90,000
Yes
16 Feb 2023
31 Dec 2022
27 Jan 2023
31 Dec 2022
25 Jan 2023
18 Jan 2023
31 Dec 2022 - 7 Jan 2023
Amount
Demolition of Concrete work (unreinforced) in ground floors and pavings including floor tiles not exeeding 15 cm thickness (below or above ground level), complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground, complete all as specified and directed.
Excavating in post holes (or similar holes) each not exceeding 0.5 cu.m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m, complete all as specified and directed.
PCC 1:2:4 type B-2 using 40mm crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified & directed.
PCC 1:3:6, type C2 (using 40mm graded stone aggregate), in sub base flooring, 50mm thick, finished even and smooth without using extra cement, complete all as specified & directed.
Machine pressed precast concrete coloured rubber moulded interlocking paver block, 60mm thick, M-35 grade, size and shape confirming to IS 15658-2006 with grey cement and pigment over and including 25mm thick sand cushioning, complete all as specified and directed.
Heavy duty parking/floor tiles 9mm to 10mm thick (square/rectangular) area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed.
Colours chequered cement concrete tiles 30cm x 30cm x 22-25mm thick, with grey cement and pigment, set, jointed and pointed in neat cement slurry in floors over and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
Plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate), 40mm thick, as in flooring, laid in alternate bays / panels, including finishing the surface even and smooth without using extra cement, complete all as specified and directed.
Glass dividing strips of 3mm thick and 38mm wide complete all as specified and directed.
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
Brickwork with flyash bricks, old size straight or curved on plan exceeding 6m mean radius, built in CM 1:6, complete all as specified and directed.
Brickwork with sub class 'B' brick, old size, straight or curved on plan exceeding 6m mean radius, built in CM 1:6, complete all as specified and directed. [Except Bricks] Note: Old bricks obtained against demolition should be used.
Taking down cement plaster on brick or stone walls or wall tiles etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified & as directed.
Rendering 10mm thick in CM 1:4 on concrete surfaces in ceiling/walls, finished fair and even smooth, complete all as specified & directed.
Rendering 10 mm thick, on fair faces of brick work or concrete surfaces in cement sand mortar 1:6, finished surface even and smooth without using extra cement, complete all as specified & directed.
Preparation of new plastered or unplastered surfaces of walls and applying two coat of cement base paint, complete all as specifed and directed.
Preparation of new plastered or unplastered surfaces of walls and applying two coat of white wash, complete all as specifed and directed.
Complete removal of exisitng treatment / finish on walls by scrapping or wire brushes including filling depressions of scrapped surfaces and preparing old decorated plastered surfaces of wall including cornices, pilastered, etc and applying two coats of white wash on wall surface, complete all as specified and directed.
Complete removal of exisitng treatment / finish on walls by scrapping or wire brushes including filling depressions of scrapped surfaces and preparing old decorated plastered surfaces of wall including cornices, pilastered, etc and applying two coats of cement base paint on wall surface, complete all as specified and directed.
PCC 1:2:4 type B-1 (using 20 mm crushed stone aggregate) as in cills, steps, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, including weathering, slightly rounded or chamfered angles and throating, including necessary formwork, complete all as specified and directed.
Broken glass coping on top of walls in CM 1:3, complete all as specified and directed. Note: Glass (of bottle or thick glass) broken to approximately 63mm gauge, shall be firmly embedded at the rate of 10 Kg of glass per square metre of rendered surface, jogged edges of the glass being left projecting
Rolled mild steel work as in posts and struts for fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 fixed in repair, complete all as specified and directed. Note: Quoted unit rate also includes locking holes after fixing of barbed wire and welding to bent portion as directed.
Fixing only rolled mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work fixed in repair, complete all as specified and directed. Note: (i) Quoted unit rate also includes locking holes after fixing of barbed wire and welding to bent portion as directed. (ii) Mild steel sections obtained from item No. 2 shall be used.
Preparation of new steel surfaces & applying two coats of synthetic enamel paint over a coat of red oxide primer, exc 10 cm width or girth, complete all as specified and directed.
Preparation of old painted steel and iron surfaces over 10cm width or girth and applying two coats of synthetic enamel paint, complete all as specified and directed.
Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc, fixed in repair, complete all as specified and directed. Note: Each line wire to be measured separately.
Restraining and resecuring including making good staples and tying with mild steel binding wire (wherever required) etc, in existing barbed wire of any description, complete all as specified and directed. Note: Each line wire to be measured separately.
Cement concrete 1:2:4 type B-1 (using 20 mm crushed stone aggregate) as in surface channels or drains, complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified and directed. Note: Only inner girth shall be measured.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for, including cutting of reinforcement to facilitate demolition complete all as specified and directed. Note: The reinforcement retrieved from demoition shall be offered to contractor under schedule of credit.
Cleaning/ clearance of blocked WC (any type) at any floor from WC to first manhole and making the drain pipe fully functional by flushing with water to entire satisfaction of Enr-in-Charge, including disposal of sludge/waster material upto 50 m, burrying the same in pit, complete all as specified and directed.
Cleaning/ clearance of blocked kitchen sink, WHBs, Urinal from nahani trap/ gully trap to first manhole and making the drain pipe fully functional by flushing with water to entire satisfaction of Enr-in-Charge, including disposal of sludge/waster material upto 50 m, burrying the same in pit, complete all as specified and directed.
Dewatering of septic tank/ soakage well of any description by manual or with sewage pump after plugging of incoming sewage line and throwing water into non residential area or in drain/nallah, complete all as specified and directed.
Cleaning of manholes, septic tanks of any capacity and size including inlet and outlet chambers removing the waste material to a distance not exceeding 50 m and burrying in pits, including covering the pit with soil (minimum layers 45cm thick), complete all as specified and directed.
Cleaning of underground drain pipe of 100 mm dia incl manholes by rodding from manhole to manhole, manhole to septic tank, flushing with water, taking out sludge and other materials blocking the drain pipes, carrying/ removing the same to a distance not exceeding 50 m and burrying in pits including covering the pit with soil (minimum layers 45cm thick), complete all as specified and directed.
Cleaning of underground drain pipe of 150 mm dia incl manholes by rodding from manhole to manhole, manhole to septic tank, flushing with water, taking out sludge and other materials blocking the drain pipes, carrying/ removing the same to a distance not exc 50 m and burrying in pits including covering the pit with soil in layers 45 cm thick, complete all as specified and directed.
Excavation in trenches not exceeding 1.5m deep & not exceeding 1.5m wide or area not exceeding 10 Sqm on plan & in soft/loose soil and getting out for foundation, trenches, manholes etc. complete all as specified & directed.
Returning, filling in soils, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick. complete all as specified and directed.
Removing surplus excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed.
Cement concrete 1:5:10 type E-2 (using 40mm graded stone aggregate) as in foundation, filling, mass concrete for filling up sunken floor, complete all as specified and directed.
Precast reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in drain cover, cover slab (for manholes) and similar work with plain faces, set in CM 1:6 with and including providing of formwork as required, complete all as specified & directed. Note: Reinforcement shall be measured and paid separately under respective items of BOQ.
PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping, cills, steps in lintels upto 1.6 mtr clear span and similar other works like bands, plinth courses, lacing courses bed plates water troughs and like including weathring, slightly rounded or chamfered angles and throating complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) of flat rough finished surfaces of concrete, complete all as specified and directed.
Supply only liquid water proofing compound, Complete all as specified and directed. Note : The liquid water proofing compound shall be used all as per manufacturer instruction only.
Dismantling floor, hearth or wall tiling including cement mortar bedding, removing rubbish off the premises, complete all as specified and directed.
Non - skid Ceramic coloured tiles 7 to 8 mm thick size of tile shall be 300mm X 300mm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
Non - skid Ceramic coloured tiles 7 to 8 mm thick, size of tile shall be 400mm x 400mm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
Glazed coloured ceramic tiles in vertical surfaces 350mm x 250mm x 7mm/ 450mm x 350mm x 7mm thick, in skirting, dados, risers to steps, etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tile including provision of 10mm thick rendering in CM 1:4, complete all as specified and directed.
Glazed coloured ceramic tiles in vertical surfaces 300mm x 200mm x 7mm, in skirting, dados, risers to steps, etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tile including provision of 10mm thick rendering in CM 1:4, complete all as specified and directed.
Rendering 15mm thick, on fair faces of brick work or concrete surfaces in cement sand mortar 1:4 mixed with water proofing compound, finished surface even and smooth without using extra cement complete all as specified & directed. Note: Water proofing compound shall be measured and paid separately as supply only.
Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified & directed.
Mild steel TMT bars 6-8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified & directed.
PVC (SWR) 110 mm bore pipes single socketed ends, in any length with rubber ring joints, fixed to walls or laid in floors, fixed in repair, complete all as specified & directed.
PVC (SWR) 75 mm bore pipes single socketed ends, in any length with rubber ring joints, fixed to walls or laid in floors, fixed in repair, complete all as specified & directed.
PVC (SWR) bends of any radius and 110mm bore, fixed in repair, complete all as specified & directed.
PVC (SWR) bends of any radius and 75mm bore, fixed in repair, complete all as specified & directed.
PVC (SWR) branch piece, single (single Y) equal or unequal, 110mm bore, fixed in repair, complete all as specified & directed.
PVC (SWR) branch piece, single (single Y) equal or unequal, 75mm bore, fixed in repair, complete all as specified & directed.
PVC (SWR) branch piece, single (double Y) equal or unequal, 110mm bore, fixed in repair, complete all as specified & directed.
PVC (SWR) branch piece, single (double Y) equal or unequal, 75mm bore, fixed in repair, complete all as specified & directed.
PVC (SWR) junction single, (Single T) equal or unequal, 110 mm bore, fixed in repair, complete all as specified and directed.
PVC (SWR) junction single, (Single T) equal or unequal, 75 mm bore, fixed in repair, complete all as specified and directed.
PVC (SWR) junction double, (Double T) equal or unequal, 110 mm bore, fixed in repair, complete all as specified and directed.
PVC (SWR) junction double, (Double T) equal or unequal, 75 mm bore, fixed in repair, complete all as specified and directed.
PVC(SWR) vent cowl, 110mm bore, fixed in repair, complete all as specified and directed.
PVC(SWR) vent cowl, 75mm bore, fixed in repair, complete all as specified and directed.
PVC (SWR) floor trap of 100mm dia, plain with grating including jointing with solvent cement concrete 1:2:4, type B-1(using 20mm graded stone aggregate), fixed in repair, complete all as specified and directed.
PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) bed to drain pipes, 100 mm bore pipe including packing under and haunching against the side of pipe after they are laid and tested, complete all as specified and directed.
PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) bed to drain pipes,150 mm bore pipe including packing under and haunching against the side of pipe after they are laid and tested, complete all as specified and directed.
PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) bed to drain pipes, 200 mm bore pipe including packing under and haunching against the side of pipe after they are laid and tested, complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, complete all as specified and directed.
Salt-glazed stoneware drain pipes, grade A of 100 mm bore laid in trenches and jointed, complete all as specified and directed.
Salt-glazed stoneware drain pipes, grade A of 150 mm bore laid in trenches and jointed, complete all as specified and directed.
Salt-glazed stoneware drain pipes, grade A of 200 mm bore laid in trenches and jointed, complete all as specified and directed.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580mm x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe), but including provision of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe, CI trap 100mm bore of pipe, fixed in repair, complete all as specified and directed.
Wash down water closet pedestal pattern, complete white with P or S trap, front or back inlet and foot rests, (excluding flushing cistern & flush pipe) and Pedestal pan and trap, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe with seat and cover for pedestal pan including flush pipes to pedestal pan and making good to match with the existing surface of floor, fixed in repair, complete all as specified & directed.
PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, 10 litres capacity, with 32mm dia polythene of low or high density pipe, fixed in repair, complete all as specified and directed.
Grating doom 125mm dia with waste hole of PTMT (minimum weight 40 gms), fixed in repair, complete all as specified and directed.
PVC (SWR) floor trap of 75mm dia, plain with grating including jointing with solvent, fixed in repair, complete all as specified and directed.
Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 110mm bore, complete all as specified and directed.
Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75 mm bore, complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning, and supply and fixing 15mm dia GI steel tube 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning, and supply and fixing 20mm dia GI steel tube 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning, and supply and fixing 25mm dia GI steel tube 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
PVC waste pipe 32mm bore, fixed in repair, complete all as specified and directed.
M/S SWATI CONSTRUCTION
M/s multienterprises
M/S DEEKSHA CONSTRUCTION
M/S Akhilesh Enterprises
RVRconstructon
Saraswati Constructions
HARI OM CONSTRUCTION
PANDEY TRADERS
Minakshi Construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .