| Sl No | Description | Qty | Unit | M/S PANJETA ELECTRICALS L1 | Pioneer Advertising Agency L2 | Bajwa Electrical Contractor L4 | Pri-Power Enterprise L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate] | 18 | Each | 130 ₹2,340 | 150 ₹2,700 | 140 ₹2,520 | 120 ₹2,160 |
| 2.00 | [23.22.8.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.2. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 100 amp 415 volts [Through Rate] | 2 | Each | 15,000 ₹30,000 | 100 ₹200 | 5,000 ₹10,000 | 6,000 ₹12,000 |
| 3.00 | [23.27.2]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 2. M.S. pedestal of size 750 mm wide , 900 mm high , 300 mm deep and bottom totally open , duly embeded in cement concrete block of size 900 mm x 450 mm x 200 mm above ground level , having a base of size 1050 mm x 600 mm x 250 mm below ground level . 0 0 [Through Rate] | 1 | Each | 9,500 ₹9,500 | 5,500 ₹5,500 | 6,500 ₹6,500 | 17,000 ₹17,000 |
| 4.00 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate] | 4 | Each | 1,600 ₹6,400 | 2,500 ₹10,000 | 2,500 ₹10,000 | 3,000 ₹12,000 |
| 5.00 | [24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. [Through Rate] | 250 | Per Meter | 13 ₹3,250 | 20 ₹5,000 | 20 ₹5,000 | 24 ₹6,000 |
| 6.00 | [24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate] | 4 | Each | 200 ₹800 | 650 ₹2,600 | 600 ₹2,400 | 700 ₹2,800 |
| 7.00 | [24.1.6]EARTHING AND LIGHTENING ARRESTOR 6. Supplying and laying 25mm x 3mm G.I. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required. [Through Rate] | 32 | Per Meter | 75 ₹2,400 | 50 ₹1,600 | 50 ₹1,600 | 50 ₹1,600 |
| 8.00 | [24.13.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) [Through Rate] | 870 | Per Meter | 140 ₹1.2 L | 170 ₹1.5 L | 170 ₹1.5 L | 220 ₹1.9 L |
| 9.00 | [24.2.4.2]LT CABLE 4.2. Laying of underground cable in pipe /existing open/closed trench etc as required:- 16 Sq mm to 35 sqmm 2 to 4 Core [Through Rate] | 870 | Per Meter | 15 ₹13,050 | 10 ₹8,700 | 8 ₹6,960 | 14 ₹12,180 |
| 10.00 | [24.2.8.4]LT CABLE 8.4. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm [Through Rate] | 48 | Each | 5 ₹240 | 15 ₹720 | 8 ₹384 | 9 ₹432 |
Tender Value
₹7.2 L
EMD Value
₹14,437
Closing Date
1 Dec 2025, 5:00 pmClosed
PRAMESH Kumar
ED - Hisar
Special Repair to E.I in DC Residence in Distt. Sirsa (Pdg. Street Light Only)
2025_HRY_485406_1
2025675AF2B2 81BC 4F7B 89C0 DB72BEC0D808666BAR
Open Tender
Electrical Works
150 days
Sirsa
2 documents required · 2 mandatory
₹1,000
₹14,437
Yes
13 Feb 2026
25 Nov 2025
2 Dec 2025
25 Nov 2025
1 Dec 2025
25 Nov 2025
Amount
[23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate]
[23.22.8.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.2. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 100 amp 415 volts [Through Rate]
[23.27.2]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 2. M.S. pedestal of size 750 mm wide , 900 mm high , 300 mm deep and bottom totally open , duly embeded in cement concrete block of size 900 mm x 450 mm x 200 mm above ground level , having a base of size 1050 mm x 600 mm x 250 mm below ground level . 0 0 [Through Rate]
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate]
[24.1.13]EARTHING AND LIGHTENING ARRESTOR 13. Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required. [Through Rate]
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate]
[24.1.6]EARTHING AND LIGHTENING ARRESTOR 6. Supplying and laying 25mm x 3mm G.I. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required. [Through Rate]
[24.13.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) [Through Rate]
[24.2.4.2]LT CABLE 4.2. Laying of underground cable in pipe /existing open/closed trench etc as required:- 16 Sq mm to 35 sqmm 2 to 4 Core [Through Rate]
[24.2.8.4]LT CABLE 8.4. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 16 sqmm [Through Rate]
[24.4.2.4]STREET LIGHT 2.4. Supply and erection of GI bracket made of 32 mm dia medium class GI pipe, having 15 deg angle from horizontal, suitable for fixing on top of Street Light pole 150 cm long, with 30 cm high suitable size pole cap. [Through Rate]
[24.4.8.3]STREET LIGHT 8.3. Supply and erection of Hot Dip Galvanized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 5 Metre Long pole with top dia 65 mm and bottom dia 130mm with base plate of size 250 x 250 x 16 mm [Through Rate]
[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate]
[24.8.3]RCC FOUNDATIONS FOR OCTAGONAL POLES 3. Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 5m high pole [Through Rate]
Supply/ errection/ testing / commissioning of timelight distribution board (Astronomical) 65 amp 3 pole / 230 Volts with digital time switch having suitable size of 1 no. 63 amp TPN MCB, 1 no. 65 amp contactor, 1 HRC fuse , 1 No. Rotray Switch, 1 No. 16 amp fuse base, 1 No. Timer switch and 1 Indicator having IP 52/56 Degree protection all items should be of same make / manufacturer including padestal, including making connection with all material required to complete the job in all respect upto the entire satisfaction of Engineer-inCharge of the work. (Make:- IndoAsian/ Havell`s/ L andT). (Rates are excluding GST).
DSR 8.14.13 Supply and Erection of 72W LED Street Light LED Street light fixture, powder coated pressuredie cast aluminium body (System lumen efficacy)135 lm/Watt). Supplying, Installation, Testing and Commissioningof Street light LED fixture, powder coated pressure die cast aluminium body with built in orseparate driver as per the requirement with Driverefficiency )85%, Input voltage: 140-270 Volt AC,requency 50/60 hz, Operating temp range -5 0C to50 0C, internal surge protection of 5 KV L,N,E as perIEC 61000-4-5, Driver efficiency )85%,THD ( 10%as per IEC 61000-3-2, P. F.=0.95, IP-66,IK-10, CRI)70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the roadand the project requirement., suitable to fit in up to65mm dia pipe, life time (LED,Driver and electricalcircuitary) of minimum 50000 Burning Hourswith 70% of initial Lumen maintained till lifeends as per LM80 extrapolation IES TM-21-11report, CCT 3000°K / 4000°K / 5700°K /6500°K (Asper ANSI Bin), SDCM(Standard Deviation ColorMatching) (5, Maximum power consumption should not more than the specified rating respect i/c external connections with 1.5 sq mmFRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required withMinimum 5 year OEM warranty. System lumenefficacy )135 lm/Watt output . LM79 and LM80 Testreport and all testing required for LED fixturesas per BIS shall be submitted.. Shape size andCCT shall be as approved by Engineer-in-Charge asper requirement. (Thermal management: heat sinkof aluminium housing such that LED junctiontemperature shall not rise above 90°C).Make Phillips / Surya/Bajaj/Wipro (Rates exclusive of GST)
DSR 8.17.2 Supply and Erection of 70W LED Flood Light ) LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy )135lm/Watt)Supplying, Installation, Testing and Commissioningof Flood Light, powder coated pressure die castaluminium body with built in or separate driver asper the requirement with Driver efficiency )85%,Input voltage: Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to50 0C, internal surge protection of 5 KV L,N,E as perIEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2, P. F.=0.95, IP-66,IK-10, CRI)70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beamangle 30 deg-120deg as per the application and theproject requirement., suitable tilt able fitting, life time(LED, Driver and electrical circuitry) of minimum50000 Burning Hours with 70% of initial Lumenmaintained till life ends as per LM80extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin) ,DCM(Standard Deviation Colour Matching) (5,Maximum power consumption should not morethan the specified rating and Fixture shall be ofrelevant BIS standard complete in all respect i/cexternal connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cableand earthing etc. as required with Minimum 5 yearOEM warranty. System lumen efficacy )135lm/Watt output. LM79 and LM80 Test report and alltesting required for LED fixtures as per BIS shallbe submitted. Shape size and CCT shall be asapproved by Engineer-in-Charge as perrequirement. (Thermal management: heat sink ofaluminium housing such that LED junctiontemperature shall not rise above 90°C).Make Phillips / Surya/Bajaj/Wipro(Rates exclusive of GST)
S/E of 5 Mtr. Decorative Pole (With Decorative 90 W LED Fitting) mild steel tubular pole having different section with cast aluminum embellishment E3. Bottom section 2000mmx140mmx4.0mm and upper section 5000mmx90mm x3.6mm. Pole has a service window and Pole base plate should be according to Foundation constructed already on site. Pole is primer coated and PU painted. Pole is suitable for Single and double arm bracket,. Bracket is provided for suspension of decorative drop down fixture. Bracket is made of Mild steel pipe with decorative mbellishment, Ornamental 90 Watt LED Drop Down luminaire made of aluminium housing duly powder coated/PU painted with PC Frosted diffuser for High illuminance/ glare free lighting. MCPCB having high lumen LED’s are mounted on aluminum heat sinks. Make - Havells/ Keselac/ Mayfair/Twinkle LuxMax/ Vak Lighting (Rates are excluding GST)
Pioneer Advertising Agency (BID ID -1376748)
Pri-Power Enterprise (BID ID -1377460)
Bajwa Electrical Contractor (BID ID -1377539)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.04 MB
BOQ_563437.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid