| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAdmitted-Finance | ₹1.6 Cr | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Delhi Electrical Construction L1 |
|---|---|---|---|---|
| 1.00 | Labour Charges for rectification of general electrical faults in all electrically connected boards/equipments/all electrical accessories,including replacement, cleaning and making them in good working condition in all hostel zone buildings and as per the terms & condition vide annexure.The replacement items should also be returned promtly for accountability.The rectification of defects and replacement of accessories should be carried by posting minimum 5 Qualified Electricians & 5 Helpers and 1 Qualified supervisor. 3 sets should be made available from 9.00 am to 6.00pm(1 hour break) and other 2 sets should be made available from 3.30pm to 12.30am(1/2 hour break). However, it is the resposibility of the sucessful bidder to complete the complaints received on same day or post more technician if the complaints have not been attended in the same day. The Fortnight report about the progress of work should be sumitted in the specific format should be submitted. The contractor should strictly follow the labour regulation act and miniumum wages act. | 12 | Month | 2,25,000 ₹27,00,000 Lowest |
| 2.00 | Labour charges for one meter reader cum technician for taking Electrical Energy Meter readings every month in Hostel buildings as instructed by the Engineer in-charge and preparing computerized statements with printouts and in addition to receiving day to day complaints over phone and through online, allocating the work, closing of job card and online complaints etc. | 12 | Month | 20,768 ₹2,49,216 Lowest |
| 3.00Supplying of following accessories while attending the faults.The contractor shall assure at least 10% of the total quantities made available always at site. The items selected for replacement shall be compatible with the existing installations. The contractor should dispose the removed accessories comes under the Part-A of this schedule once in fortnight or earlier. No any accessories should be left any of the location of the campus. The contractor shall arrange for transportation/man power for safe disposal outside the campus. The contractor should include the negative/positive value for each item after accessing the value of the items and considering the manpower/transport. | ||||
| 3.01 | 7-10 watts LED Bulb(Philips/CG/Bajaj/Syska) | 100 | Nos | 143 ₹14,300 Lowest |
| 3.02 | 3-9 watts candle LED/Threaded LED lamp (Philips/CG/Bajaj/Syska) | 20 | Nos | 117 ₹2,340 Lowest |
| 3.03 | 1.75-2.5MFD Fan condensor (USHA) | 1,000 | Nos | 45 ₹45,000 Lowest |
| 3.04 | Slanting/Pattern/Pendent holder (Anchor Make) | 250 | Nos | 45 ₹11,250 Lowest |
| 3.05 | 1Way/2Way/3Way/4Way PVC junction box/Cover | 250 | Nos | 10 ₹2,500 Lowest |
| 3.06 | Ceiling rose (Anchor Make) | 500 | Nos | 45 ₹22,500 Lowest |
| 3.07 | 3 core 2.5 sqmm copper flexible wire | 100 | Nos | 90 ₹9,000 Lowest |
Tender Value
₹1.9 Cr
EMD Value
₹3.8 L
Closing Date
18 Feb 2025, 3:00 pmClosed
Executive Engineer (Electrical)
Engineering Unit, Admin Block 3rd Floor, IIT Madras CHENNAI-600036
Annual Maintenance of for day to day Electrical Maintenance, minor and alteration works for Hostel zone Buildings and maintenance of power mains starters for motors pumpsets in IIT - Madras Campus for the year of 2025-26
2025_IITM_226002_1
03/2025-26/ELDB
Open Tender
Electrical Works
Item Rate
365 days
IIT MADRAS CHENNAI
All required documents as mentioned in the tender
2 documents required · 2 mandatory
₹0
₹3.8 L
GOOGLE MEET
25 Feb 2025
7 Feb 2025
19 Feb 2025
7 Feb 2025
18 Feb 2025
13 Feb 2025
7 Feb 2025 - 12 Feb 2025
12 Feb 2025
Amount
Labour Charges for rectification of general electrical faults in all electrically connected boards/equipments/all electrical accessories,including replacement, cleaning and making them in good working condition in all hostel zone buildings and as per the terms & condition vide annexure.The replacement items should also be returned promtly for accountability.The rectification of defects and replacement of accessories should be carried by posting minimum 5 Qualified Electricians & 5 Helpers and 1 Qualified supervisor. 3 sets should be made available from 9.00 am to 6.00pm(1 hour break) and other 2 sets should be made available from 3.30pm to 12.30am(1/2 hour break). However, it is the resposibility of the sucessful bidder to complete the complaints received on same day or post more technician if the complaints have not been attended in the same day. The Fortnight report about the progress of work should be sumitted in the specific format should be submitted. The contractor should strictly follow the labour regulation act and miniumum wages act.
Labour charges for one meter reader cum technician for taking Electrical Energy Meter readings every month in Hostel buildings as instructed by the Engineer in-charge and preparing computerized statements with printouts and in addition to receiving day to day complaints over phone and through online, allocating the work, closing of job card and online complaints etc.
7-10 watts LED Bulb(Philips/CG/Bajaj/Syska)
3-9 watts candle LED/Threaded LED lamp (Philips/CG/Bajaj/Syska)
1.75-2.5MFD Fan condensor (USHA)
Slanting/Pattern/Pendent holder (Anchor Make)
1Way/2Way/3Way/4Way PVC junction box/Cover
Ceiling rose (Anchor Make)
3 core 2.5 sqmm copper flexible wire
3 core 4 sqmm copper flexible wire
4 core 2.5sqmm copper flexible wire
4 core 4.0sqmm copper flexible wire
LED Driver for wattage from 22 to 40W
LED Driver for wattage upto 20W
Supplying of following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
10KA,6A to 32A Single Pole MCB
10KA,6A to 32A double Pole/SPN MCB
10KA,6A to 32A Triple Pole MCB
10KA,6A to 32A Four Pole/TPN MCB
10KA,40A to 63A Triple Pole MCB
10KA,40A to 63A Four Pole MCB
24 hours time switch(Legrand Microrex QT11 or equivalent as per Engineer Incharge)
40 amps TP/FP power contactor (DIN mounting)
Supplying of following rating isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40A Double pole isolator
63A Double pole isolator
40A to 63A Four pole isolator
80 A-100 A Four pole isolator
Supplying of following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
100 ma, 25-32A DP RCBO
100 ma, 20-32A 4P RCBO
100 ma, 40 to 63A 4P RCBO
Supply and replacement of following type kWH meter/CTs as required
3 phase 4 wire -/5A CT operated Panel mounting kWH meter class 1 accuracy with RS485 port
3 Phase CT operated Multifunction Meter with Import - Export Energy recording facility with RS485 port
Current Transformer Class 1 of Voltage rating 0.66 kV , and ratio of 60/5A.
Current Transformer Class 1 of Voltage rating 0.66 kV , and ratio of 100/5A.
Current Transformer Class 1 of Voltage rating 0.66 kV , and ratio of 200/5A.
Current Transformer Class 1 of Voltage rating 0.66 kV , and ratio of 250/5A.
Current Transformer Class 1 of Voltage rating 0.66 kV , and ratio of 400/5A.
Supply and replacement of following heating element/ thermostat in the existing equipments in various hostel zone buildings
Heating element for Geyser upto 2000watts (Racold make or equivalent as per Engineer Incharge)
Themostat with control for Geyser upto 2000watts (Racold make or equivalent as per Engineer Incharge)
25 litres electric vertical mount storage geyser. The approved make will be Racold Altro super or equivalent of Venus,Bajaj,CG.
Labour charges to provide duty to an electrician for various function at SAC or any other location as and when requires as directed by the concerned engineer to monitor and attend the minor electrical faults, switch on the lights and fans as and when required during the function . The minimum duration of the posting will be 4 hours. Every four hours will be calculated as 1 duty.
Labour charges for making temporary power connection by laying 4 core 16 sq.mm alu.arm cable and making the energy meter panel for different vendors for taking temporary power supply.
Labour charges for checking the earth electrode as and when required as directed by the concerned engineer at site using suitable earth megger and tools & plant and submit the printed report or log sheet/book. The charges inclusive of pouring of the water after checking the earth electrode.
Charges for cleaning the fans,fittings,switch boards and other electrical accessories with requried cleaning agents.
Charges for engaging 2 semiskilled to carry out various electrical related works such as removing the existing wirings,transporting the equipments, accessories from one place to other place(without any conveyance) within the campus,transportation of ladders, relocation of stores if any and other works as and when arisen. The day means the number working hours in a day 8 hours.
Supplying & fixing of following sizes lamimnated sheet with requried cutting in the existing wooden/metal box.
300MM X 200MM
200MM X 150MM
200MM X 100MM
150MM X 100MM
100MM X 100MM
Supplying of following Modular base & cover plate on existing modular metal boxes etc. as required.
1 or 2 Module
3 Module
4-5 Module
6 Module
8-10 Module
12 Module
18/16 Module
Supplying of following size/ modules, GI box/surface box alongwith modular base & cover plate for modular switches in recess etc as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4-5 Module (125mmX75mm)
6 Module (200mmX75mm)
8-10 Module (125mmX125mm)
12 Module (200mmX150mm)
18/16 Module(250mmx200mm)
Supplying of metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
100 mm X 100 mm X 60 mm deep
150 mm X 150 mm X 60 mm deep
200 mm X 150 mm X 60 mm deep
200 mm X 300 mm X 100 mm deep
Supplying of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
2 way 5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Bell push
100 watts Fan regulator
Blanking plate
15/16 amp switch with indicator
Supplying of following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
5/6 amps switch
2 way 5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Bell push
15 amps 5 in one CS plug
15 amps 2 in one CS plug
5Amps 3 Pin Top (Anchor/Record)
15Amps 3Pin Top (Anchor/Record)
2 pin & scrapping earth MC pin top
3 pin & scrapping 3 phase MC pin top
2 pin & earth MC socket
3 pin & earth MC socket
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Rewinding/overhauling of the following fans using enameled copper wire of required gauge,varnishing oiling,greasing etc.,overhauling such as cleaning,replacement of same size and rating of bearing,condenser,cotter pins,shackle insulator,twin core copper wire and other defective materials required for making the fan in good working condition.The cost should include the rebate of old enameled copper materials.The guarantee of the fan after rewinding should be 6 months from the date of installation.The workmanship shall be Grade A and up to the satisfaction of the Engineer -in-charge.
1200mm/1400 mm sweep AC ceiling fan
300mm sweep medium duty exhaust fan
375-450mm sweep heavy duty exhaust fan
MOTOR PUMP ROOM MAINTENANCE
Attending the general electrical faults in starters / power mains / terminal of motors in domestic water / sewage water pump motor upto 20.0 Hp pump motors at anywhere in IIT Madras campus as and when required.
Attending the general electrical faults in controllers/probe/Sensor/Panels of automatic water level controllers at anywhere in IIT Madras campus as and when required.
Reconditioning of Mono Submersible pump of following rating including using PVC double coated copper wire & necessary insulation materials.The charges inclusive of replacement of long brass bushes/Thrust bearings,rubber oil seal, stud/bolt/nuts, lock nut, packing, gascut, O ring, shaft reconditioning or replacement,any lathe work for unremovable bolts. The charges inclusive of complete pump side dismantling, impeller & body cleaning, reassembling, painting & testing and replacement of HI-Bolt, new main cable with core rubber and Transportation. The warrantee of the reconditioning shall be at least 6 months.In case of failure of pump within 6 months, the vendor is responsible for reconditioning the same at free of cost.
3.0 HP.3 phase, 2800 RPM
5.0 HP.3 phase, 2800 RPM
7.5 HP.3 phase, 2800 RPM
10.0 HP.3 phase, 2800 RPM
15.0 HP.3 phase, 2800 RPM
20 HP Vertical Nonclog Submersible sewage pump
30 HP Vertical Nonclog Submersible sewage pump
Installation testing and commissioning of submersible starter / DOL / star delta panel on the existing board / wall with required accessories ( The starter panel will be supplied by the dept )
Supply and fixing of following electrical accessories for domestic water / sewage water pump room in anywhere in IIT Madras as and when required.( Samples to be DOL approved before purchase )
3 phase DOL submersible starter up to 7.5 HP motors with built in dry run protection and singel phasing prevention( Type MU-G10 of L & T or equivalent as per Engineer Incharge)
3 phase Star delta submersible starter suitable for 15 HP motors built in dry run protection and singel phasing prevention( Type MUG 20 of L & T or or equivalent as per Engineer Incharge)
Current sensing single phase preventor (Type SPPR SDz5/L & T or equivalent as per Engineer Incharge)
Electronics timer suitable for Star Delta Starter for set time from 0-30 seconds
Thermal OLR upto 20 HP starters
Push button station 1 NO+1 NC
32 amps auxiliary contactor
3 pole power contactor (10A - 40A)
Supply of following capacity pumps of required head and flow requirements.Pump model to be got approved before supply. Make KSB/Wilo/Kirloskar/CRI/Lubi
3 HP, 415V,Openwell Submersible Pump
5 HP, 415V, Openwell Submersible Pump
7.5 HP, 415V, Openwell Submersible Pump
10 HP, 415V,Openwell Submersible Pump
15 HP, 415V,Openwell Submersible Pump
20 HP Vertical Non Clog Submersible sewage Pump
Circulation Pumps upto 0.5 HP (Temp upto 110 c)
Circulation Pumps 0.5 HP to 1 HP (Temp upto 110 c)
Supplying, installation testing and commisioning of Low level and high level switch in OHT/sump with connection to work the system automatically.The sample got to be approved before procurement. The approved make shall be JKN/BEEKAY or or equivalent as per Engineer Incharge
Supply and installation of 1100v grade unarmoured copper conductor cable/flat cables on wall with necessary GI clamps hardware and as per site conditions from starters terminals to motor terminals
4 core 6 sq.mm
4 core 10 sq.mm
3 core 16 sq.mm
4 core 2.5 sq.mm
4 core 4 sq.mm
3 core 2.5 sq,mm copper flat wire
3 core 4 sq.mm copper flat wire
Addition alteration and minor works
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
Group B
Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 10 sq. mm earth wire
4 X 16 sq. mm + 2 X 16 sq. mm earth wire
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1 x 1.5 sq. mm
2 x 2.5 sq. mm
2 x 4 sq. mm
2 x 6 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of following size MK premium base & lid CMS with accessories including end caps, flexible internal/external comers flat angles,Flat tee, Joint cover wherever necessary with cable divider, required type of modular box etc
100mm X 100mm
50mm X 50mm
Supplying and fixing suitable size Surface/GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size Surface/GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1 run of cable
1200mm x 22w LED light fittings. The approved make will be PHILIPS LED BN021LED22S PSU CW GR or equivalent as per Engineer Incharge
600mm x 12w LED light fittings. The approved make will be PHILIPS LED BN021LED12S 6500 PSU GR or equivalent as per Engineer Incharge
18 watts surface/recess mounted square/round LED lighting fixture.The accepted make and model will philips rimless Fullglow or equivalent as per Engineer Incharge
1200mm x 36 w LED suspended light fittings. The approved make will be Crompton Trend I LCPL54-36-CDL or equivalent as per Engineer Incharge
10watts LED Bulk Head lighting fixture.The accepted make and model will Philips EnduraLED WT202W or LED SM 270C LED30S6500PSU or equivalent as per Engineer Incharge
Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supplying,testing and placing of 450mm dia sweep high breeze low noise pedestal mounting air circulator. The approved make shall be ALMONARD or equivalent as per Engineer Incharge
Supply Installation of exhaust fan of following ratings in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. The approved make shall be ALMONARD or equivalent as per Engineer Incharge
225mm medium duty exhuast fan(Metal blade-double ball bearings)
300mm medium duty exhuast fan(Metal blade-double ball bearings)
380mm medium duty exhuast fan(Metal blade-double ball bearings)
450 mm heavy duty exhaust fan(Metal blade-double ball bearings)
200 & 250mm Fresh air fan(plastic body)
Supply and fixing of the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and fixing of outdoor type lighting luminaire of following watts and model LED luminaire with driver unit on aluminium alloy powder coated in greylish black shade with heat resistance toughend glass complete including all accessories and hardwares with suitable size GI pipe bending to shape as required.
25 watts LED(Philips Model BRP 020X10LED-HP/CW PSUGR equivalent as per Engineer Incharge)
45 watts LED(CG Model LSTP-45-CDL or equivalent as per Engineer Incharge)
50 watts LED flood light luminaire.The approved make and model shall be CG make/LEEFC50WHPLED/W equivalent as per Engineer Incharge
200 watts LED flood light luminaire.The approved make and model shall be CG/LFLN-200-CDL/60 equivalent as per Engineer Incharge.
Providing and fixing following rating and breaking capacity MCCB in existing MCCB DB/cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
100 Amp, 16 KA, 4 Pole
125 Amp, 16 KA 4 Pole
160 Amp, 25 KA 4 Pole
63 Amp, 16 KA,3 Pole
100 Amp, 16 KA 3 Pole
125 Amp, 16 KA 3 Pole
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2 + 8 way, Double door
2 + 12 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
4 way (4 + 12), Double door
8 way (4 + 24), Double door
Supplying and fixing following ways surface/ recess mounting, vertical type, 415 volts, TPN MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, with provision of TP/4P 16 KA MCCB as incomer, interconnection between incomer MCCB and bus bars (but without MCB's/ MCCB) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
8 Way TP
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 volts,MCBs in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 volts, MCBs in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40-63 amps MCB
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 16/25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 25/32/40amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 4 pole weather proof enclosure on surface to accommodate 4P MCBs as required.
Supplying and fixing of fan hook on ceiling and making the ceiling in original condition with required civil work.
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc.as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of Hot Dipped Galvanised Iron cable tray cover with 25mm on each side using 1.6mm thick (Galvanisation thickness not less than 50 microns) including G.I. bolts & nuts, etc.as required.
100 mm width
150mm width
300 mm width
Earthing with hot dipped GI earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with SFRC cover and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with SFRC cover and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
MV CABLE
Supply of following sizes XLPE copper conductor armoured UG cable of approved make.
4 core 2.5 sqmm
4 core 6 sqmm
4 core 10 sqmm
4 core 16 sqmm
Supply of following sizes XLPE aluminium conductor armoured UG cable of approved make.
3.5 core 25 sq.mm
3.5 core 50 sq.mm
3.5 core 70 sq.mm
3.5 core 95 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Charges for removing the existing cable from the trench of depth upto 75mm deep x 50mm wide including necessary earth work excavation refilling etc as required.
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 core 2.5 sqmm
4 core 6 sqmm
4 core 10 sqmm
4 core 16 sqmm
Supplying and making end termination with brass compression gland and Aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5 core 25 sq.mm
3.5 core 50 sq.mm
3.5 core 70 sq.mm
3.5 core 95 sq.mm
Supply and construction of masonry pedestal for covering the earth pit as required using bricks,cement mortor as required.
Charges for providing 450 x450mm SFRC cover on the existing earth pit chamber including necessary modification masonry work to provide the SFRC cover.
Charges for white washing the existing earth pit and marking in 2 location of the earth chamber as BE-1/2 or NE-1/2 as required.
Supply & Fixing of MS angle iron, channel, chequred plates with 2Coats of Primer, 2coats of enamel panit & Complete in all respect etc for any unanticipated usages as per site condition. Charges to include necessary civil works associated with grouting etc.,(This item is for any unanticipated work. Supports for pumps Panel, pipes etc., will not be measured in this.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
TenderNoT03.pdf
Tender Documents • 1.53 MB
PriceBidForViewT03.pdf
Other Document • 0.78 MB
BOQ_253016.xls
BOQ • 0.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .