GEMC-511687752191087
Awarded to Sun Enterprises
₹3.3 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Elisa Plate Reader | Statfax 4200 | - | 1 NOS | ₹3.3 L | 329,999 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.3 LQualified Make: Awareness Technology
Model: Statfax 4200 00 CHUCHAILA KHURD CHUCHAILA KALAN DHANAURA AMROHA JYOTIBA PHULE NAGAR UTTAR PRADESH 244231 | AMROHA | UTTAR PRADESH | 244231 | Make: Awareness Technology
Model: Statfax 4200 | L1 | Qualified | |
| 2 | Disqualified Make: Agappe
Model: mispa viva ENCLAVE 1 DELHI 110048 | SOUTH DELHI | DELHI | 110048 | Make: Agappe
Model: mispa viva | - | Disqualified | |
| 3 | Disqualified Make: BiolineIndia
Model: BiolineIndia EPR12 84 ELECTRONIC COMPLEX PARDESHIPURA BEHIND OPTEL INDORE MADHYA PRADESH 452010 | INDORE | MADHYA PRADESH | 452010 | Make: BiolineIndia
Model: BiolineIndia EPR12 | - | Disqualified | |
| 4 | Disqualified Make: NuLyte
Model: NuLyte POCT | Make: NuLyte
Model: NuLyte POCT | - | Disqualified | |
| 5 | Disqualified Make: NA
Model: MEDICA CORPORATION - Easy Stat Blood Gas Analyzer I P EXTENSION DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: NA
Model: MEDICA CORPORATION - Easy Stat Blood Gas Analyzer | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
7 Jul 2018, 4:00 pmClosed
blood gas analyser Blood Gas Analyser ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values Complete set of details Blood Gas Analyser (BGA) System BGA is whole blood benchtop equipment for measuring and calculating complete Blood Gas Analysis in laboratory BGA is POCT (Point of Care Test) for measuring and calculating complete Blood Gas Analysis
BGA is whole blood benchtop equipment for measuring and calculating complete Blood Gas Analysis in laboratory BGA have facility for measuring; pH
pCO2
pO2
Na+ & K+ on one robust self contained platform yes - BGA also have facility to test broad range of blood gases
electrolytes and other critical chemistry test for measuring: Cl
iCa
Glu
BUN
Hct
Cre atinine
Lacate
HCO3
T CO2
BEecf
BEb
02SAT
i Ca(N)
tHb
MDRD GDR As per GeM Catalogue. BGA works with Cartridge(s) and/or Reagent(s): Single use Cartridge/Reagent (for Benchtop equipment) Single Use Cartridge for POCT
Multiple Use Cartridge for POCT
Single use Cartridge/Reagent (for 1/3 Benchtop equipment) Monitor type Touch Screen Colour display Touch Screen Colour display
LCD Display Shall have Inbuilt B P (Barometer Pressure)
Inbuilt/thermal Printer
Complete menu for blood gases
Hematocrits
electrolytes and other chemistries With Inbuilt Printer With Inbuilt Printer
With Thermal Printer external Shall have facility to test BAG Parameters in single and multiple test cartridges Yes - Shall delivers realtime patient result using electrochemical sensor technology yes - Cartridge/reagent to be used can be stored mostly at room temperature between 2-30 Degree C
Automatic calibration Yes - Shall have patient Bar Code facility
Ability to run a wide range of patient panels on one system false Capability to transfer patient data to LIS/HIS false Certification US FDA US FDA
CE- European Weight (Kg) >5-20 0-5
>5-20
>20 Warranty (Year) 5 3
5 Power requirement POCT BGA- Power Supply 220 V/50 Hz AC POCT BGA-- Battery Rechargeable
Power Supply 220 V/50 Hz AC(Both)
POCT BGA- Power Supply 220 V 50 Hz AC
POCT BGA-- Battery Rechargeable
Bench top BGA - Power Supply With UPS 30 Min Backup * Bold specifications are the golden parameters. 2/3 Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anil Anilkumar@106 585106
SEDAM ROAD
NEAR GULBARGA UNIVERSITY GULBARGA 1 15 Required No ePBG Required No
283532
GEM/2018/B/40246
GeM Contract
blood gas analyser
GeM Contract
15 days
Karnataka; Kalaburagi
PRODUCT
Awarded to Sun Enterprises
₹3.3 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Elisa Plate Reader | Statfax 4200 | - | 1 NOS | ₹3.3 L | 329,999 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| blood gas analyser Blood Gas Analyser ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values Complete set of details Blood Gas Analyser (BGA) System BGA is whole blood benchtop equipment for measuring and calculating complete Blood Gas Analysis in laboratory BGA is POCT (Point of Care Test) for measuring and calculating complete Blood Gas Analysis | - | - | - |
| BGA is whole blood benchtop equipment for measuring and calculating complete Blood Gas Analysis in laboratory BGA have facility for measuring; pH | - | - | - |
| pCO2 | - | - | - |
| pO2 | - | - | - |
| Na+ & K+ on one robust self contained platform yes - BGA also have facility to test broad range of blood gases | - | - | - |
| electrolytes and other critical chemistry test for measuring: Cl | - | - | - |
| iCa | - | - | - |
| Glu | - | - | - |
| BUN | - | - | - |
| Hct | - | - | - |
| Cre atinine | - | - | - |
| Lacate | - | - | - |
| HCO3 | - | - | - |
| T CO2 | - | - | - |
| BEecf | - | - | - |
| BEb | - | - | - |
| 02SAT | - | - | - |
| i Ca(N) | - | - | - |
| tHb | - | - | - |
| MDRD GDR As per GeM Catalogue. BGA works with Cartridge(s) and/or Reagent(s): Single use Cartridge/Reagent (for Benchtop equipment) Single Use Cartridge for POCT | - | - | - |
| Multiple Use Cartridge for POCT | - | - | - |
| Single use Cartridge/Reagent (for 1/3 Benchtop equipment) Monitor type Touch Screen Colour display Touch Screen Colour display | - | - | - |
| LCD Display Shall have Inbuilt B P (Barometer Pressure) | - | - | - |
| Inbuilt/thermal Printer | - | - | - |
| Complete menu for blood gases | - | - | - |
| Hematocrits | - | - | - |
| electrolytes and other chemistries With Inbuilt Printer With Inbuilt Printer | - | - | - |
| With Thermal Printer external Shall have facility to test BAG Parameters in single and multiple test cartridges Yes - Shall delivers realtime patient result using electrochemical sensor technology yes - Cartridge/reagent to be used can be stored mostly at room temperature between 2-30 Degree C | - | - | - |
| Automatic calibration Yes - Shall have patient Bar Code facility | - | - | - |
| Ability to run a wide range of patient panels on one system false Capability to transfer patient data to LIS/HIS false Certification US FDA US FDA | - | - | - |
| CE- European Weight (Kg) >5-20 0-5 | - | - | - |
| >5-20 | - | - | - |
| >20 Warranty (Year) 5 3 | - | - | - |
| 5 Power requirement POCT BGA- Power Supply 220 V/50 Hz AC POCT BGA-- Battery Rechargeable | - | - | - |
| Power Supply 220 V/50 Hz AC(Both) | - | - | - |
| POCT BGA- Power Supply 220 V 50 Hz AC | - | - | - |
| POCT BGA-- Battery Rechargeable | - | - | - |
| Bench top BGA - Power Supply With UPS 30 Min Backup * Bold specifications are the golden parameters. 2/3 Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anil Anilkumar@106 585106 | - | - | - |
| SEDAM ROAD | - | - | - |
| NEAR GULBARGA UNIVERSITY GULBARGA 1 15 Required No ePBG Required No | - | - | - |
Exempted
27 Jul 2018
3 Jul 2018
contract_GEMC-511687752191087.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_283532.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .