Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹75.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹89.4 L+₹13.9 L (18.3%)Rejected-Finance 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | L2 | Rejected-Finance Other than L1 | |
| 3 | Rejected-Technical SPECIAL 1 INDUSTRIAL ESTATE NEW POWER HOUSE ROAD JODHPUR 342003 | JODHPUR | RAJASTHAN | 342003 | - | Rejected-Technical BEING TWO CLASS BELOW |
Tender Value
₹75.7 L
EMD Value
₹1.4 L
Closing Date
15 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE MATHURA
HQ CWE MATHURA
AS PER TENDER DOCUMENTS
2022_MES_500825_1
CWE/MTR/BPR/58 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
RMS Dholpur
CLASS C CAT b(ii)
7 documents required · 7 mandatory
₹1,000
GE BHARATPUR
₹1.4 L
Yes
16 Mar 2022
11 Jan 2022
23 Feb 2022
11 Jan 2022
15 Feb 2022
1 Feb 2022
60 days
Amount
M&L Excavation in post holes in soft/disintigrated rock or (similar holes) each n exc 0.5 Cum getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance n exc 50m and making good surface. complete all as specified and directed.
Excavation in trenches in soft / disintegrated rock not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick of soft / disintegrated rock in trenches/pit complete all as specified and directed.
Removal of surplus excavated material (Rock) to a distance not exceeding 50 m and depositing where directed not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
S&F Mild steel work as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc, and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, dia of neck 11 to 15mm and length of bolt exc 10cm and n. exc 15cm long complete all as specified and directed.
S&F chain link fencing (100X100mm) made out of mild steel galvanised wire 10 Gauge, conforming to IS 2721 including line wires, to any type of standard, rails, straining bolts, etc including provision of binding wire, fixed to steel/RCC post with mild steel flat & nut bolt etc. Note: Mild steel nut, bolt, line wire and flat steel/RCC parts bars will be measured and paid separately as S&F under respective item of BOQ.complete all as specified & directed.
M&L TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. complete all as specified and directed.
M&L for preparation of new steel surfaces of any descrption and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for providing precast cement concrete 1:2:4 type B1 20 mm graded aggregate as in window or door cills, lintels bressumers steps, quoin blocks (for use with masonary), string courses, copings, kneelers, appex stones, pier caps, columns, posts, boundary pillars, anchorage blocks, bonders (for stone walling) with plain fair faces, including chamfers, weatherings, throatings etc and set in cement mortar 1:6 complete with joints to match complete all as specified and directed.
M&L brick work with sub class 'B' bricks old size bricks straight or curved on plan exc 6mtr mean radius, built in CM (1:6) complete all as specified and directed.
M&L 15mm thick rendering in CM (1:6) on brick/concrete wall surfaces finished even & smooth without using extra cement complete all as specified and directed.
M&L preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of white wash complete all as specified and directed.
Framed work as in door or gates of angle or other section with guset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering, doors, etc to be prepared for hanging or sliding, with and including either hooks, and hinges or steel hanging, door fittings (exclusive of steel sheeting or other covering, running rails and guides) and , hanging also fastening and fixing confooring to FE-410-W Gde E-250 quality 'A' complete all as specified and directed.
Labour only for dismantling existing ACSR conductor from LT/HT OH line and dismantling all LT/HT insulators, jumpers and unwanted connections etc complete all as specified and directed.
Labour only to taking out old UNSV earthing any size and type from earth pit complete all as specified and directed.
Material & Labour for dismantling of existing 250 KVA transformer of any type and size from existing sub station platform and shifting to the same transformer on new Trolley complete all as specified and directed. Note- (i) rates are Including dismantling of existing external electric supply from pole VCB/MCCB and refixing as required (ii) after fixing of transformer to trolly carried out with necessary nut bolts/ plate stopper/welding works as required to smooth movement of transformer with safety
Supply and installation commissioning and testing HT 11 KV. outdoor extensible type, cubical , 4-way (LRRL-2LBS+2VCB)), Gas (SF6) Insulated RMU comprising with 2 Nos x LBS (Load break switches) and 2 Nos x VCB of rating of each 630 Amp 3 phase 50 cycles 12 KV, 21KVA/ 3 Sec Ambient temperature - (-5 degree Celsius to +55 degree Celsius), Manual Operated SF6-Breaker having copper bus bar of suitable size, cast resin tank with , LV Current transformer compatible with self powered relay& 11KV reign cast PTs (one set of 3Nos) with separate metering chamber complete Make SIEMENS model 8DJH ST / Equivalent item as specified in list of make
Each Load break switch will have the following: (i) SF6 three position switches with position ON-OFF-EARTH. (ii) Manual Operated spring mechanism ON-OFF-EARTH for 630A Load Break switch. (iii) Mechanical indicators for position ON-OFF-EARTH. (iv) Mimic diagram at the front facia of RMU. (v) Socket for Capacitive Voltage Indicator ( "Live Cable “ Indicating LEDs energized thru Capacitive Voltage Dividers. (vi) Padlocking facility. (vii) Cable box suitable for cable termination of 1 no. 3Cx 120 sq.mm. XLPE cable.
Accessories with each RMU includes (i) Operating handle - 1 Nos. (ii) Right angled Cable boots Make Siemens /equivelent- 4x sets. (iii) Capacitor Voltage indicator type HR-ST - Make Hartmann 4 Nos.
Separate Metering chamber having : (i) 3 Phase, 3 Limb draw out type bus connected Epoxy potential transformer, ratio 11KV/√3/110V/√3 AC accuracy 1.0, Burdon 50 VA -01. (ii) Digital type voltmer -1Nos. (iii) RYB indication - 1set.
Note:- (i) RMU shall be outdoor plinth mounted as per OEM design. (ii) Erections commissioning and civil work (Plinth protection) for RMU is deemed to be included with unit rate. The plinth protection details as per the manufacturer instruction.
Supply, installation, testing & commissioning of transformer of capacity 315 KVA step down outdoor type copper wounded 11/0.433 KV (at no load) AC 3 phase 50HZ on secondary side double wound oil immersed naturally all air cooled (ONAN COOLED) with external cooling tubes /radiator , delta connected as on primary and star connected with natural brought on secondary) side and having tapping at (±) 2.5%,(±) 5% (±) 7.5% to be changed by hand operated OFF LOAD tap changing gear . The maximum temperature rise should not exceed 45 degree centigrade in oil and 50 degree centigrade in HV/ LV winding when measured by the resistance method after continuous full load run in ambient temperature the transformer shall confirrming to IS 1180 Part-I:2014; Level-3 and comprising of following accessories complete all as specified and directed.
(a) HV side Cable box with 03 Nos porcelains HV bushing with arching horns on HV side suitable for 11 KV complete with bushing rods and nuts washers and cable glands suitable for reception of out 3 core 95 Sqmm cable 3 runs, HT Cable 11000 Volts grade XLPE insulated heavy duty including gland complete. (b) 01 No cable end box on LV secondary side consisting of 05 Nos porcelain bushing (One No neutral earth, One No Neutral and Three No for phase connected bushing) with bushing rods and nuts washers and cable glands suitable for reception of out 3.5 core 400 Sqmm cable 3 runs, LT 1100 Volts grade XLPE insulated heavy duty including gland joint complete. (c) Oil conservator with filter type drain valve and oil level gauge. (d) Dehydrating breather with first filling of dehydrating agent. (e) Explosive vent. (f) Thermometer pocket including temperature gauge. (g) Two earthing terminals on tank body to facilitate fixing of 32x6mm GI strips. (h) One No thermometer dial type vapour pressure type having range 0-120 degree centigrade with maximum temperature indicator and re-setting device to maximum temperature including needle of temperature gauge: Max reading painted terminal. (j) Rating plate with terminal plate. (k) Oil level gauge. (l) Oil drain filter valve. (m) Oil filling hole on top cover with plug. (n) Air release valve/plug. (o) 4 Nos plain solid cast steel detachable rollers. (p) First fill of transformer oil conforming to relevant ISI and tested upto 60 KV dielectric strength. (q)Two No lifting hook at side of transformer. (r) 1Nos Breather duly filled with silicajel crystals
Note : Providing platform for transformer of size 3.0x3.0x1.5m high from GL including excavation in trenches not less than 1 mtr, PCC 1:5:10 type E2 for foundation, brick work in cm 1:6, PCC 1:2:4 type B1 in copping, plaster 10mm thick in cm 1:6 om brick /complete surface PCC 1:4:8 type B1 sub base 75mm thick, as in flour PCC 1:2:4 type B1 100mm thick floor using extra cement returning filling and removal on surplus soil, including 2 Nos ISMB 100mm channel painting with 2 coat aluminium paint over a coat of red oxide primer and 3 coats of white washing on cement work for fixing transformer including ramp of suitable size mounting of transformer complete all as specified and directed.
Supply and installation commissioning and testing factory made and tested (including CPRI certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phase, 4 wire , 50 Hz AC supply system all as specified and directed having bus bar chamber with insulated copper bus bars 400 amps rating installed on porcelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner 2.0 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 40 x 40 x 6 mm thick angle iron for stand. The necessary electric connection of MCCB above including 63 amp should be carried out copper bus bar and below 63 amp should be carried out from 16 sqmm single core copper cable. The complete feeder pillar box should be power coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm for metering system. Front & Back opening type with cable alley for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. The scope of work includes provn of the followings :-
Incoming :-
MCCB 4 pole breaking capacity 35 KA thermal magnetic adjustable type- 200 Amps - 01 Nos.
Copper Bus bar 400 Amps - 04 Nos.
Outgoing :-
MCCB 4 pole breaking capacity 25 KA thermal magnetic adjustable type- 160 Amps -01 Nos.
MCCB 4 pole breaking capacity 25 KA thermal magnetic adjustable type- 100 Amps -03 Nos.
MCCB 4 pole breaking capacity 16 KA thermal magnetic adjustable type- 40 Amps -02 Nos.
Supply and installation, commissioning and testing factory made and tested (including CPRI certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phase, 4 wire , 50 Hz AC supply system all as specified and directed having bus bar chamber with insulated copper bus bars 200 amps rating installed on porcelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner 2.0 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 40 x 40 x 6 mm thick angle iron for stand. The necessary electric connection of MCCB above including 63 amp should be carried out copper bus bar and below 63 amp should be carried out from 16 sqmm single core copper cable. The complete feeder pillar box should be power coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm for metering system. Front & Back opening type with cable alley for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. The scope of work includes provn of the followings:-
Incoming :-
MCCB 4 pole breaking capacity 16 KA thermal magnetic adjustable type- 63 Amps - 01 Nos.
Copper Bus bar 200 Amps - 03 Nos.
Outgoing:-
MCCB TPN 40 AMP 16KA -03 Nos.
Supply and installation, commissioning and testing factory made and tested (including CPRI certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phase, 4 wire , 50 Hz AC supply system all as specified and directed having bus bar chamber with insulated copper bus bars 800 amps rating installed on porcelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner 2.0 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 40 x 40 x 6 mm thick angle iron for stand. The necessary electric connection of MCCB above including 63 amp should be carried out copper bus bar and below 63 amp should be carried out from 16 sqmm single core copper cable. The complete feeder pillar box should be power coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm for metering system. Front & Back opening type with cable alley for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. The scope of work includes provn of the followings:-
Incoming :-
MCCB 4 pole breaking capacity 35 KA thermal magnetic adjustable type- 630 Amps - 01 Nos.
Copper Bus bar 800 Amps - 04 Nos.
Outgoing :-
MCCB 4 pole breaking capacity 35 KA thermal magnetic adjustable type 400 AMP -01 Nos.
MCCB 4 pole breaking capacity 25 KA thermal magnetic adjustable type 100 AMP - 03 Nos.
MCCB 4 pole breaking capacity 16 KA thermal magnetic adjustable type 63 AMP -01 Nos.
Supply and installation, commissioning and testing factory made and tested (including CPRI certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phase, 4 wire , 50 Hz AC supply system all as specified and directed having bus bar chamber with insulated copper bus bars 600 amps rating installed on porcelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner 2.0 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 40 x 40 x 6 mm thick angle iron for stand. The necessary electric connection of MCCB above including 63 amp should be carried out copper bus bar and below 63 amp should be carried out from 16 sqmm single core copper cable. The complete feeder pillar box should be power coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm for metering system. Front & Back opening type with cable alley for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. The scope of work includes provn of the followings:-
Incoming:-
MCCB 4 pole breaking capacity 35 KA thermal magnetic adjustable type- 400 Amps - 01 Nos.
Copper Bus bar 600 Amps - 04 Nos.
Outgoing:-
MCCB 4 pole breaking capacity 25 KA thermal magnetic adjustable type 160 AMP -01 Nos.
MCCB 4 pole breaking capacity 25 KA thermal magnetic adjustable type 100 AMP -03 Nos.
MCCB 4 pole breaking capacity 25 KA thermal magnetic adjustable type 63 AMP -03 Nos.
Supply and installation commissioning and testing factory made and tested (including CPRI certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phase, 4 wire , 50 Hz AC supply system all as specified and directed having bus bar chamber with insulated copper bus bars 600 amps rating installed on porcelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner 2.0 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 40 x 40 x 6 mm thick angle iron for stand. The necessary electric connection of MCCB above including 63 amp should be carried out copper bus bar and below 63 amp should be carried out from 16 sqmm single core copper cable. The complete feeder pillar box should be power coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm for metering system. Front & Back opening type with cable alley for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. The scope of work includes provn of the followings:-
Incoming:-
MCCB 4 pole breaking capacity 35 KA thermal magnetic adjustable type- 400 Amps - 01 Nos.
Copper Bus bar 600 Amps - 04 Nos.
Outgoing:-
MCCB 4 pole breaking capacity 25 KA thermal magnetic adjustable type 160 AMP -01 Nos.
MCCB 4 pole breaking capacity 35 KA thermal magnetic adjustable type 200 AMP -03 Nos.
Supply and installation, commissioning and testing factory made and tested (including CPRI certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phase, 4 wire , 50 Hz AC supply system all as specified and directed having bus bar chamber with insulated copper bus bars 300 amps rating installed on porcelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner 2.0 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 40 x 40 x 6 mm thick angle iron for stand. The necessary electric connection of MCCB above including 63 amp should be carried out copper bus bar and below 63 amp should be carried out from 16 sqmm single core copper cable. The complete feeder pillar box should be power coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm for metering system. Front & Back opening type with cable alley for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. The scope of work includes provn of the followings
Incoming
MCCB 4 pole breaking capacity 25 KA thermal magnetic adjustable type- 160 Amps - 01 Nos.
Copper Bus bar 300 Amps - 04 Nos
Outgoing:-
MCCB 4 pole breaking capacity 25 KA thermal magnetic adjustable type 100 AMP -02 Nos.
MCCB 4 pole breaking capacity 25 KA thermal magnetic adjustable type 63 AMP -01 Nos.
MCCB 4 pole breaking capacity 16 KA thermal magnetic adjustable type 40 AMP -02 Nos.
Note:- For serial no 21 to 26 (i) Panel should be fixed on angle iron stand made out of 40x40x5mm thick angle iron frame of 60cm height above GL and 15 cm below GL. (ii) PCC for foundation in PCC 1:3:6 below 15 Cm GL and above GL 30 cm all around the panel stand. (iii) Cable alley to be provided in all LT panel (iv) All cable (new and old extg ) to be fitted with suitable gland. (v) Old cable connection to be carried out with suitable new lugs.
Supply installation testing and commissioning indoor type , outdoor type, Self standing, double door, front and back openable, APFC panel compartmental type with APFC relay 8 stage with heavy duty MPP capacitor bank 120KVAR (50 KVAr-1Nos, 20 KVAr-02 No, 10KVAr-02 Nos,5KVAr-02 Nos with 7% detuned harmonics filter reactor ) with thirstier control module and MCCB 4 Pole of 36 KA of 1.5 time of rating current of capacitor suitable for each control and MCCB 4 ploe 160 Amp 36 KA as incomer including control CT & control wiring complete having following accessories including control wiring with HR FRLS copper wire complete all as specified and directed. (i) Compact modular bolted design, removable side and back panels with option of top and bottom cable entry. (ii) Capacitor installed in removable assemblies for ease of operation and maintenance. (iii) Incoming of APFC panel of MCCB TP 160 Amps, 36 KA breaking capacity with high electrolytic grade Aluminium bus bar of suitable rating. (iv) 120KVAR (50 KVAr-1Nos, 20 KVAr-02 No, 10KVAr-02 Nos,5KVAr-02 Nos with thirstier control module and MCCB TP of 36 KA of 1.5 time of rating current of each capacitor suitable for each control . ( each capacitor bank equipped with discharge resister) & 7% detuned haRMonics filter reactor. (v) High performance microprocessor based 3 phase APFC relay 8 stage with Auto/Manual Option. (vi) In built 3 phase power analyzer , Amp meter, volt meter and PF meter (each have 1 No). (vii) Capacitor duty thirstier control modules with high thermal current carrying capacity and early make contacts to reduce inrush current for enhancing life of capacitors. (viii) Induced air system provided with axial flow fan/ centrifugal fan. (ix) Bottom cable entry system available with front glass for viewing controller and analyzer from front.
Note:- (i) panel should be fixed on angle iron stand made out of 40x40x5mm thick angle iron frame of 60cm height above GL and 15 cm below GL. (ii) PCC for foundation in PCC 1:3:6 below 15 Cm GL and above GL 30 cm all around the panel stand. (iii) cable alley to be provided in all LT panel. (iv) All cable (new and old extg ) to be fitted with suitable gland. (v) old cable connection to be carried out with suitable new lugs.
Supply, laying and testing cable XLPE insulated, screened PVC bedded, galvanised steel stripped or wire armoured electric cable heavy duty with stranded aluminium conductor , 1100V grade for the following sizes complete all as specified and directed.
400 Sqmm 3.5 core
300 Sqmm 3.5 core
240 Sqmm 3.5 core
70 Sqmm 3.5 core
50 Sqmm 3.5 core
35 Sqmm 3.5 core
25 Sqmm 4 core
16 Sqmm 4 core
Supply, laying and testing HT cable XLPE insulated, screened PVC bedded, galvanised steel stripped or wire armoured electric cable heavy duty with stranded aluminium conductor , 11KV grade of size 95 Sqmm, 3 core complete all as specified and directed.
S&F Junction box made out of HDPE / Poly carbonate PVC plastic suitable for outdoor installation of size min 300 mm x200mmx150mm with hinged door and locking arrangement including aluminium bus bar of size 25x3mm three phase & Neutral fixed on insulator, including one No MCB SP 6 amps and 08 RM 1.5 Sqmm 3 core copper cable from light to pole box complete all as specified and directed.
S&F rubber mat of size 01mtr x 2mtr x 19mm as insulating material as per IS specifications and IE regulations complete all as specified and directed.
Supply and fix cable jointing kit outdoor termination, end joint, 11KV grade, heat shrink type, joint complete with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 spmm complete all as specified and directed.
M&L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test point including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on complete all as specified and directed. Note :- The cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate.
Material and labour for Earthing complete with copper earth plate electrode of size 600x600x3.15mm thick buried directly in ground (earth pit should not less than 4 mtr deep below normal ground level ) with top edge of the plate not less than 2.95 mtr deep below normal ground connected to and included copper earth strip 32mmx 6mm by means of copper bolts nuts check nuts and washer returning and filling the pits with excavated soil mixing with charcoal 250 kg crystal salt 200 kg magnesium sulphate of 100 kg and vegitable soil all around the plate up to 350 mm above from top edge of plate and balance portion filling with excavated soil in layers not exc 25 mm thick 25 mm bore galvanised iron medium grade watering pipe up to top of plate 50mm bore galvanised iron light grade pipe for earth strip protection including all excavation earth work in any type of soil pcc 1:3:6 type C1 using 20mm graded stone aggregates for chamber of internal size 300mmx 300mmx300mm with 120mm thick wall and 700mmx700mmx150mm thick bed concrete RCC 1:2:4 type B1 for precast chamber cover 50mm thick reinforced with welded steel wire fabric or X PM jali (weight not less than 4.00 kg/sqmm) ,funnel, with wire mesh complete all as specied and directed. Note (i) Quoted rate shall be deemed to include for earth strip with protection pipe up to 7.5 M length
Supply only ready to use double wheel Trolley with four jacks and towing hook for mounting of transformer 315 KVA transformer of size approx Min size (1.8 M x 2.4 M), mild steel chassis size 125mm x 65mm, Axle mild steel 65mm X 65mm, chequered/ Plain MS plate on top 8mm thick, suitable for lifting of weight approx 2 tonne, duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, towing hook of channel/angle iron, fixed with trolley for easy movement from one place to another place. it shall not less than 1.25 metres from channel, including 2 Nos set of rim, tyre and tube 7.50 x 16 (16 ply) of Make MRF/CEAT/Apollo) leaf spring set with U-clamp, Axle etc complete with and including 400 Amp MCCB 4 Pole with 35ka adjustable type suitable outdoor type enclosure to connect from transformer LT side with suitable copper cable of 70 sqmm single core 4 no of 5 mtr length and trolly plateform should be covered with coke mess wire with frame structure of angle iron made out of 25x25x4mm thick all around with opening arrangement and top should be covered with fiber reinforced sheet made out of 40x40x5mm angle iron complete all as specified and directed. (a) contractor shall be provided 25mm dia copper solid bar 2m long one side taper and other side provide suitable lugs to connect the earthing with of size 10sqmm single core copper conductor for carrying out earthing of trolly mounted transformer .(b) contractor shall provide 10sqmm single core copper wire 40mtr for earthing
Supply and laying burnt clay Sub class B old size Bricks in trenches over the LT/HT cables for the protection of cables, laid across the length complete all as specified and as directed.
M&L local river sand for bedding or sand cushioning of all HT/LT UG cable complete all as specified and directed.
Supply and installation, testing and commissioning of pressure sand filter MSRL type consisting dual media filtration, including activated Carbon & Media Filter Column, pebble, gravels, green sand not less than 500Kgs, vessel dia min1200mm, height min 2000mm, Multi Grade Filtration and Activated carbon Filtration, specially made for reducing the Volatile gas Hydrogen Sulphide, back washing facility, CI/GI fittings & Valves, Pressure gauge for the operating pressure 0.5Kg-min-2Kg-Normal-3Kg/Max & backwash pressure 0.5Kg-min-2Kg-Normal-3Kg/Max etc. including RCC foundation of capacity more than 30 m3/Hr, including connecting to existing CI/GI pipeline all as specified and as directed. Note:- (a) interconnection pipe from external 2 no of sources (PHED/bore well) should be connected through sluice valve of 150mm-01 nos and 100 mm -01 Nos. (b) necessary control valve suitable for operation of pressure send filter to be carried as per OEM(supply/back wash/by pass). (c) PCC foundation as per OEM instruction .
Supply and fixing in repair of GI water tubing IS-1239 marked, medium grade, in replacement including all necessary pipe fittings laid in trenches, on wall, under floor, under road on same or new route and making good the disturbed portion as existing and including taking down of old unserviceable pipe of the following sizes:- Note :-excavation earth work will be measured and paid separately.
100 mm bore.
50 mm bore.
25 mm bore.
Pioneer Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .