| 1 | L1₹58.2 LAccepted-AOC H NO 787 22 JHANG COLONY ROHTAK 124001 | ROHTAK | HARYANA | 124001 | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical GAUSHALA MARKET TEHSIL NARNAUL NARNAUL 123001 | NARNAUL | NARNAUL | HARYANA | 123001 | - | Rejected-Technical Enlistment expired |
Tender Value
₹49.6 L
EMD Value
₹99,126
Closing Date
9 May 2024, 5:00 pmClosed
Ravi Ladwal
ED Rewari
Construction of SDO (Civil) complex at kanina In Distt Mohindergarh. (Pdg. Substation and DG set only)
2024_HRY_370042_2
2024F8B30C4A 0B24 47E0 8A74 5A8D2BA11EC2668BAR
Open Tender
Civil Works
Works
180 days
Kanina
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
₹99,126
Yes
15 Jan 2025
9 Apr 2024
13 May 2024
9 Apr 2024
9 May 2024
9 Apr 2024
Amount
[13.18]Providing and fixing hard drawn steel wire fabric 75 mm X 25 mm rectangular mesh with 3.25 mm dia wire fixed on steel windows of standard rolled sections with 3 mm thick flat iron cover moulding of 12.5 mm width fixed with machine screws welded complete in all respect.
[13.2]Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
[23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA
[23.22.2.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.2. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 250 A FP
[23.22.8.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.2. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 100 amp 415 volts
[23.24.3.9]MS STAND, BUS BAR CHAMBER AND PANELS 3.9. Supply and erection of metal clad bus bar chamber made from 1.6 mm thick M.S. sheet and fixing with rag bolts on wall or on existing pedestal/angle iron frame including bonding, detachable top and bottom including painting and necessary connection etc. (Aluminium bars). 300 amp 4 bars of 100 cm each (cross section 51 mm x 6 mm) chamber over all size 1.10 m x 55 cm x 23 cm
[23.26.1]SAFETY ITEMS 1. Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages.
[23.26.2]SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages.
[23.26.3]SAFETY ITEMS 3. Supply and erection of shock restoration chart in glass frame.
[23.26.4]SAFETY ITEMS 4. Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6x4 made of GI pipe 32mm dia).
[24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.
[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required.
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.
[24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.
[24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.
[24.2.7.4]LT CABLE 7.4. Supply and erection of suitable compression type brass cable glands for underground Cable :- 70 sqmm to 95 sqmm Cable 3 to 3½ Core
[24.2.8.8]LT CABLE 8.8. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 70 sqmm
[24.2.8.9]LT CABLE 8.9. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 95 sqmm
[24.3.3.1]HT CABLE 3.1. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm
[24.3.4.1]HT CABLE 4.1. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm
[24.5.2.5]MISCELLANEOUS ITEMS 2.5. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 120/105 mm outer dia/ inner dia
[24.7.3]RCC FOUNDATIONS FOR DG SET 3. 100 KVA DG Set
[24.7.5]RCC FOUNDATIONS FOR DG SET 5. 250 KVA DG Set
Supply and erection of Rubber Mat 1mx2mx 3mm thick suitable for 11/33 KVA as per IS No. 15652C/M/L 3017739 as per approved by Chief Electrical inspector, Govt. of Haryana.
Supply and erection of Fire Extinguishers duly hang on wall with necessary hook complete in all respect. Make( Make: Safex /Minimax / Cease Fire). CO2 type 4.5 Kg Capacity.
S/E of fire bucket of G.I. sheet of 24 gauge write with ` FIRE` as per fire specification.
Supply and erection of Fire Extinguishers duly hang on wall with necessary hook complete in all respect. Make Make: Safex /Minimax / Cease Fire). ABC Dry Powder extinguisher 6 Kg Capacity.
Supply Erection testing and Commissioning of 11 KV indoor HT metering panel complete with C.Ts P. Ts. Cubical and electronic meter with accurancy class as per requirment/approved by DHBVN at he time of installation, consisting of the following. Cubical panel free standing floor mounting type made out of sheet steel 14 SWG CRCA sheet with chanel iron base frame spray painted with strong synthetic light grey enamel paint as per size and design approved by the DHBVN 3 Nos. 11 KV CTS of ratio as approved by DHBVN for indoor installation of appd. Make of 1 Nos. 11 KV PTs 11000/110 Volts Oil filled suitable for indoor installation of approved make of DHBVN. Digital Electronic Meter 3 phase 4 wires recording in KWH and rating and accuracy as by DHBVN with push button display operating system of different kind of readings. The cubical panel will be complete in all respect including interconnection, internal wiring with PVC copper cable, its testing and approval of all item by DHBVN including cost of all testing/ approval charges of all items of DHBVN including cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the engineer in charge of the work.(NS)
Supply and Erection of 11 meter pole complete the job in all respect upto the entire satisfaction of Engineer-in-Charge.(NS)
Supply and Erection of G.I. Half Clamps Wt. 1.47 kg. HVPN Drg. No. 2380 complete the job in all respect upto the entire satisfaction of Engineer-in-Charge. (NS)
Supply and Erection of G.I. Full Clamps Wt. 2.325 kg. HVPN Drg. No. 2349 complete the job in all respect upto the entire satisfaction of Engineer-in-Charge. (NS)
Supply and Erection of 11 KV pin insulator with pin complete the job in all respect upto the entire satisfaction of Engineer-in-Charge.(NS)
Supply and Erection of G.I. Channel 100x50x6mm 2200mm for H pole, wt. 21.100 kg complete the job in all respect upto the entire satisfaction of Engineer-in-Charge.(NS)
Supply and Erection of G.I. Angle iron 50x50x6mm 2400mm for earth wire, wt. 10.80 kg complete the job in all respect upto the entire satisfaction of Engineer-in-Charge. (NS)
Supply and Erection of 11 KV GO switch complete with handle, pipe and supporting channel complete the job in all respect upto the entire satisfaction of Engineer-in-Charge. (NS)
Supply and Erection of ACSR conductor 50mm2 (Rabbit) complete the job in all respect upto the entire satisfaction of Engineer-in-Charge.(NS)
Supply and Erection of G.I. nut and bolt off sizes complete the job in all respect upto the entire satisfaction of Engineer-in-Charge. (NS)
Supply and erection of HT 11KV XLPE under ground cable, loose in existing pipe or trenches complete with necessary connections. 50 Sq. mm 3 Core Ard. Cable . (NS)
S/E stay sets 8` long complete with X-Plat 460mm of Angie 65x65x6 Elbow and Rod Wt 13.80 kg (NS)
Supply and Erection of Stay wire/GSS wire 7/8 SWG (4mm) complete the job in all respect upto the entire satisfaction of Engineer-in-Charge. (NS)
Supply and Erection of Lightning arrestor 9KV, 5KA (3Nos.) complete the job in all respect upto the entire satisfaction of Engineer-in-Charge.
Supply and Erection of G.I. Channel 75x40x6mm 2200mm for fuse unit complete the job in all respect upto the entire satisfaction of Engineer-in-Charge.(NS)
Supply, installation, testing and commissioning of 11kV compact secondary substation outdoor type designed for natural cooling (K-10 class), having type tested equipments comprising of dry type CRT transformer and SF-6 insulated compact switchgear enclosed in robotically sealed stainless steel tank, low-voltage switchboard, interconnection between HT switchgear to transformer using Aluminium conductor Cables and transformer to LT-switchgear using Copper busbars, factory built ready for connection type, internal GI earthing provided complete with other associated equipments etc. complete as required conforming to IEC 62271-202 only and relevant IS specifications, as regards to design, manufacturing, type-testing, routine-testing and general operator safety precautions (IAC AB 20kA/1-sec). The enclosure shall have modular construction using G.I. Sheet steel and shall be powder-coated from exterior, with all major equipment inside common enclosure. The Transformer compartment will have IP-23D ingress protection, whereas the transformer used shall be Cast Resin Type specially designed for low losses as per losses defined.( Make: ABB/Schneider/Siemens). RMU, LT Switchgear, Vacuum Interrupter shall be of same make as PSS OEM to ensure life cycle optimization . Also, System Integrator/Licencse partner make CSS shall not be acceptable . The compact substation shall primarily consist of : A) HT SWITCHGEAR having 01nos FIxed-Type Load break Switches and 02nos. Fixed-Type VCB (feeding into Transformer), enclosed in common tank( 2.5 mm thick ), made of robotically welded non-magnetic/non-ferritic Stainless Steel sheets, filled with SF6 gas acting as an excellent insulating medium, IP-67 tank design having leakage rate less than 0.1% per-annum, whereas it shall be Arc-Proof design with Internal Arc criteria of 20kA/1-sec individually. The Compact Switchgear shall be a front-flushed design with integrated spring-charging handle and associated Capacitive Voltage LED Indicators for arc-proof cable box, with associated Terminal Protector boots for mounting on site-replaceable cable bushings and front-facia semaphore mechanical indication for breaker ON/OFF/EARTH and associated Fault Passage Indicator for incoming Load break switch. The breaker will be provided with integrated Self-Powered 3OC plus 1EF relay with Low and High set for Over current and Earth Fault. Relay should have facility to display the maximum loaded phase current also.Relay shall record minimum 5 fault records with time stamping, and shall be operated via Resin cast RingCore Protection CTs of suitable ratio an burden.( Make: ABB/Schneider/Siemens) B) TRANSFORMER shall comprise of 200KVA 11KV/433V DYn11 Copper Wound Cast Resin Dry Type Transformer with Off load tap links of plus 5% to -5% @2.5% with WTI scanner. Class of Insulation: H, Temperature rise limits 115 deg.C over ambient of 50 degrees. Losses (as per IS tol.) - No Load losses - 1000 W and Full load losses - 4000 W(Subject to IS Tol.) with WTI scanner and Surge arrestor on the HV side .(Make-ABB India Limited/Schneider/Siemens)
Supply and erection of under ground cable, loose in existing pipe or trenches complete with necessary connections. 95 Sq. mm 3.5 Core Ard. Cable
Supply and erection of under ground cable, loose in existing pipe or trenches complete with necessary connections. 70 Sq. mm 3.5 Core Ard. Cable
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .