Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.9 LAccepted-AOC | ₹47.9 L Quoted ₹49.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹52.8 L+₹3.8 L (7.78%)Rejected-Finance | ₹52.8 L+₹3.8 L (7.78%) | L2 | Rejected-Finance OTHER THAN L1 |
| 3 | L3₹54.0 L+₹4.9 L (10.1%)Rejected-Finance | ₹54.0 L+₹4.9 L (10.1%) | L3 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹55.5 L
EMD Value
₹1.1 L
Closing Date
27 Aug 2020, 6:00 pmClosed
CWE SHILLONG
HQ CWE SHILLONG SE FALLS SHILLONG MEGHALAYA - 793011
SPL REPAIR TO JACKWELL PUMP HOUSE AND ALLIED SERVICES AT BARAPANI UNDER GE UMROI
2020_MES_351372_3
8408/UMR/E8
Open Tender
Civil Works - Others
Works
180 days
UMROI
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
GE UMROI
₹1.1 L
Yes
29 Sept 2020
13 Aug 2020
29 Aug 2020
13 Aug 2020
27 Aug 2020
13 Aug 2020
Amount
Taking down cement plaster on brick or stone walls, including racking out joints, hacking for key, scrubbing down with water etc and removing rubbish off the premises complete all as specified and directed.
M&L for 15mm thick rendering in CM (1:4) in two layers mixed with water proofing compound @ 3% by weight of cement in top 5mm thick layer finishing the surfaces fair and even without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separately.
Supply only integral water proofing compound.
M & L for rendering 10mm thick on fair faces of brickwork or concrete surfaces in cement mortar (1:6)concrete surface finished even and smooth without using extra cement, complete all as specified and directed.
M & L for rendering 5mm thick on fair faces of brickwork or concrete surfaces in cement mortar (1:3) concrete surface finished even and smooth without using extra cement, as in ceiling, complete all as specified and directed.
M&L for preparing newly plastered surfaces of walls and applying three coats of white wash, complete all as specified and as directed.
M&L for preparing old plastered surfaces of walls and applying one coat of white wash, complete all as specified and as directed.
M&L for preparing newly plastered surfaces of ceilings and applying three coats of white wash, complete all as specified and as directed.
M&L for preparing old plastered surfaces of ceilings and applying one coat of white wash, complete all as specified and as directed.
Demolition cement concrete (un-reinforced) of any descriptions, in Ground Floors (Floor Topping, Sub-base, etc.) not exc. 150mm thick, above or below Ground Level and removing rubbish off the premises complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40 mm graded aggregate) as in plinth protection 75mm thickness, finished even and smooth using extra cement including 10mm wide and 30mm deep joints at every 2.4mtrs interval filled with mastic compound etc complete all as specified and as directed by Engr-in-Charge.
Material & Labour PCC 1:2:4 type B1 40mm thick, using 20mm graded stone aggregate as in flooring and finished surface even and fair using extra cement complete all as specified and as directed.
Demolition of unreinforced cement concrete of any descriptions, any position not otherwise specifically provided and removing rubbish off the premises complete all as specified and directed.
M & L for PCC 1:3:6 type C2 ( using 40 mm graded crushed stone aggregate) as in surface channel and drains, complete all as specified and directed
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified
Material & Labour screed bed or bedding layer of cement mortar (1:4) ,15 mm thick for laying floor finishes, complete all as specified and directed.
Supply & Fixing non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but n.exc 0.11 Sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over screed bed complete all as specified and as directed. (Note: Screed bed will be measured and paid separately)
M&L screed bed or bedding laying of cement mortar 1:4 10 mm thick for as in vertical surfaces such as skirting , dados etc, complete all as specified and as directed.
Supply & Fixing of glazed ceramic coloured tiles 300x200x 7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match on vertical surface of wall complete all as specified and as directed. Note : Backing coat will be measured and paid separately.
Supply & Fixing Vitreous china wash hand basin size 550x400mm (flat back or angle back type) fixed in repair including 32mm dia brass chromium plated waste fitting a pair of cast/angle iron bracket duly painted including cutting and pinning in ends making good disturbed surfaces in CM 1:3 including taking down unserviceable wash hand basin and connected items of any description, complete all as specified and as directed.
Supply & Fixed 15mm bore dia pillar taps, fancy type chromium plated with capstan heads chromium plated screwed down high pressure, with or without lettered 'hot or cold' with long screwed shank and fly nuts screw for iron pipe, fixed in repair.
S&F Bib taps in repair 15mm bore, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
Supply & Fixed Brass chromium plated bottle traps 32mm for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed, complete all as specified and as directed.
Supply & Fixing in repairs PVC connection 15 MM size with PTMT nuts of length 600mm complete all as specified and as directed.
Supply & Fixing 32 mm low density polyethylene pipes (LDPE) of pressure rating 6 kgf/sqcm fixed to walls ceiling or in floor etc. complete all as specified and directed.
Supply & Fixing in repairs brass chromium plated tubular towel rail, 20mm dia, 60cm long between flanges complete all as specified and as directed.
S&F in repairs110mm PVC (SWR) pipes double socketed, in any length with rubber ring joints fixed to walls, complete all as specified and directed.
S&F 110mm PVC (SWR) bends any radius, provided with access door, complete all as specified and directed.
S&F PVC (SWR)110mm bore junction single (single T), complete all as specified
S&F PVC (SWR)110mm bore junction single (single T), provided with access door complete all as specified
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, complete all as specified and directed.
Material & Labour PCC 1:2:4 type B1 25mm thick, using 20mm graded stone aggregate as in flooring and finished surface even and fair using extra cement complete all as specified and as directed.
Material & Labour for Applying tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg/sqm including cleaning surfaces, complete all as specified and as directed.
Material & Labour for Applying a layer of APP based polymeric membrane, 3mm thick (minimum) weighing 3.0 Kg per square metre reinforced) with polyester non woven fabric weighing not less than 150 gms per square metre laid on primed surface by torch application. The overlap shall be not less than 100mm on transverse direction and 75mm on longitudinal direction and sealing overlaps, complete all as specified and as directed.
Material & Labour for cutting groove in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with CM 1:3, complete all as specified and as directed.
Material & Labour for providing cement concrete type B0 1:2:4 (12.5mm graded aggregate) as in roof kerbs rounded or chamfered on edges, complete all as specified and as directed.
Materials and Labour for complete removal of existing treatment from wall and applying two coats of oil bound distemper paint over one coat of primer including preparation of surfaces complete all as specified and directed.
Materials and Labour for applying two coats of oil bound distemper paint over one coat of primer on newly plastered surfaces including preparation of surfaces complete all as specified and directed.
Materials and Labour for complete removal of existing treatment from wall and applying two coats of cement based paint over one coat of primer including preparation of surfaces complete all as specified and directed.
Materials and Labour for applying two coats of cement based paint over one coat of primer on newly plastered surfaces of walls including preparation of surfaces complete all as specified and directed.
Taking down chowkhats or frames with shutter (without taking off shutter from the frame) not exceeding 1.5 sqm each and making good the disturbed surfaces and removing unserviceable materials from site of work complete all as directed by the Engineer-in-Charge.
Taking down chowkhats or frames with shutter (without taking off shutter from the frame) exceeding 1.5 sqm and not exceeding 4 sqm each and making good the disturbed surfaces and removing unserviceable materials from site of work complete all as directed by the Engineer-in-Charge.
Taking down shutters of any description exceeding 1 sqm and n exc. 2 Sqm each complete all as directed by the Engineer-in-Charge.
S & F PVC solid door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying and fixing in opening complete all as per specification.
S & F factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS Tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C" of 20mm width stuck inside with solvent cement for stiles and plan colour PVC sheets for top rail, lock rail and bottom rail on either side and as finish insert for top rail and colour PVC sheet to be fitted in the MS Frame welded/sealed to PVC sheet beading and jointed together with solvent cement, complete all as specified and directed .
S & F for butt hinges 75 mm long medium weight, cold rolled mild steel complete all as directed by the Engineer-in-Charge.
S & F for butt hinges 100 mm long medium weight, cold rolled mild steel complete all as directed by the Engineer-in-Charge.
S&F aluminium anodised barrel tower bolt of 100 mm long with bright bolt complete all as directed by the Engineer-in-Charge.
S&F aluminium anodised barrel tower bolt of 150 mm long with bright bolt complete all as directed by the Engineer-in-Charge.
S&F aluminium anodised barrel tower bolt of 200 mm long with bright bolt complete all as directed by the Engineer-in-Charge.
S&F Aluminium handles, cast type, anodised 150 size complete all as directed by the Engineer-in-Charge.
S&F 2nd class hardwood 35mm thick glazed and skeleton door shutter(with sash bars) open rebated to receive gauze etc fitted with cut and mitred beads for securing gauze and fixed to frame complete all as directed by the Engineer-in-Charge.
S&F 2nd class hardwood 30mm thick glazed and skeleton window shutter(with sash bars) open rebated to received gauze etc fitted with cut and mitred beads for securing gauze and fixed to frame complete all as directed by the Engineer-in-Charge.
S & F 2nd class hardwood Plain, framed, panelled shutters (any number of panels), 35mm thick, with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers and supplied and fitted to chowkats complete all as directed by the Engineer-in-Charge..
M & L for stainless steel wire mesh, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F 3.00 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane, complete all as specified and as directed.
M&L for two coat of painting with synthetic enamel paint over a coat of pink primer including preparation of wooden surfaces over 10cm width or girth complete all as specified and as directed.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed.
S&F Aluminium alloy, anodised 300 mm long sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed.
Taking up or down steel tubing 20mm bore and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
S&F 20mm bore Tubes, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Taking up or down steel tubing 15mm bore and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
S&F 20mm bore Tubes, 'medium grade' galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Dismantling of plain or corrugated steel sheeting , any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and as directed.
S&F Galvanised, corrugated mild steel sheeting 0.63 mm thickness with two corrugation side lap, fixed with coach screws and washers, in roofs, walls etc with grade of zinc coating 120,fixed with L-type or J-type or self driving screws, complete all as specified and directed by Eng-in-Charge.
All as per item No.67 here in before but except sheeting, complete all as specified and as directed.
Supply & Fixing 0.80mm thick plain galvanised mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade zinc coating 120 complete all as specified and as directed.
S&F for Mild steel flat as in wind ties of roofs, ridge, etc. including supply of new nuts, bolts, washers as required/ ordered for securing, complete all as specified and directed.
Material & Labour applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel surface of girth not exceeding 10cm width or girth complete all as specified and as directed.
Dismantling wall and ceiling board any thickness including cover fillets and removing rubbish off the premises complete all as specified and directed.
Material & Labour for 4 mm thick non asbestos fibre cement bldg board fixed to timber frame work in repairs with screws as in ceiling complete all as specified and as directed
M&L 2nd class hardwood plain fillets, bullnosed, splayed, chamfered or rounded on one edge or face, wrought, secured with screws , area exceeding 6 sqcm but not exceeding 13 Sqcm, complete all as specified and as directed
M&L 2nd class hardwood plain fillets square, rectangular or triangular in section, wrought, secured with nails, in repairs, area not exceeding 3 sqcm, complete all as specified and as directed
Material & Labour for applying two coats of synthetic enamel paint over a coat of pink primer on new wooden surface of any description not exceeding 10cm width or girth complete all as directed.
Dismantling boarding, any description, fixed in any position with screws and removing rubbish off the premises complete all as specified and directed.
Supply & Fixing 20 mm thick 2nd class hard wood boarding fixed with nails in any situation and planed one side as in eave board, complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed.
Supply & Fixing sheet glass ordinary quality 4mm thick glazing in square/ rectangle not exceeding 0.50 sqm each pan with oil putty or aluminium/wooden beads fixed to steel/wood etc complete all as specified and as directed.
Material & Labour 4mm thick figured glass, pin headed type and glazing with oil putty or aluminium/wooden beads fixed to steel/wood etc complete all as specified and as directed
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed.
Demolition of reinforced concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically and removing rubbish off the premises complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for Reinforced cement concrete (nominal mix 1:2:4, type B1) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for reinforced cement concrete (nominal mix 1:2:4, type B1) as in Columns, pillars, piers, posts and struts, etc complete all as specified and as directed.
M&L for providing, cement concrete 1:2:4, type B0, using 12.5 mm graded aggregate as in copings, kneelers, apex stones, bed plates, kerbs like including weathering, slightly rounded or chamfered angles and throating, as directed.
Use and water formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed.
Use and water formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed.
M&L Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc Fe - 410 - W (Gde E 250) quality B, complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, painted one shop coat of zinc chromate primer paint (including preparation of surface) before fabrication also fastening and fixing complete all as specified and as directed.
S& F Mild steel, plain, black sheet 1mm in wall cladding, steel gates and similar work, cut to size, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed.
S&F TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
All as per item No 95 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
M&L for Rendering 5mm thick in CM 1:4 on fair faces of block masonry or concrete surfaces, rendering is to be finished even and smooth without using extra cement complete all as specified and as directed.
M&L applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome on new steel surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type soil complete all as specified and as directed.
Removing excavated material not exceeding. 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion posts embedded in concrete, and making good disturbed ground complete all as specified and as directed.
M&L Providing reinforced cement concrete type B-l, 1:2:4 (20 mm graded stone aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area exceeding 100 sqcm and not exceeding 250 sqcm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed complete all as specified and as directed.
Dismantling fencing wire mesh, any type complete all as specified and as directed.
M & L for galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed.
M&L for mild steel bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
Demolition stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar.
M&L Cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed with white cement and pigment, set jointed and pointed in neat cement slurry in work on vertical surfaces as in skirting, dados and risers of steps, cut complete all as specified and as directed.
M&L Chequered cement concrete tiles 25cm x 25cm x 22mm thick machine pressed with white cement and pigment, set jointed and pointed in neat cement slurry in work as in floor complete all as specified and as directed.
M&L Cement concrete tiles bullnosed 32cm x 24.85cm x 30mm thick, machine pressed with white cement and pigment, set jointed and pointed in neat cement slurry in work as in treads complete all as specified and as directed.
Demolition of Brickwork/precast concrete block walling work built in cement mortar and removing rubbish off the premises complete all as specified and directed.
M & L for pre-cast cement concrete Type C1,1:3:6 (20mm graded stone aggregate) block masonry with solid blocks, exc. 10cm in width and setting in mortar (1:6), complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed.
M & L for precast RCC type B-1 1:2:4 ( using 20 mm graded stone aggregate ) as in cover slab set in CM 1:4 including necessary form work if required complete all as specified and directed.
Material & Labour for PCC 1:4:8 type D2 100mm thick, using 20mm graded stone aggregate as in flooring complete all as specified and as directed.
M&L for hard core of broken stone of boulders of gauge not exceeding 63mm deposited spread and levelled in layers not exceeding 15cm thick watered and rammed to a true surface complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed.
M & L for precast cement concrete solid blocks of 100 mm size, length 200x 300 in PCC 1:3:6 type C1, using 20 mm graded stone aggregate & set in cement mortar 1:6, embedded in earth vertically not exceeding 30 cm deep as in kerb complete all as specified and directed.
Supply, laying connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade, cross sectional area 10 Sqmm 2.0 core laid through duct/pipe/in trench, etc. including taking out old unserviceable cable complete all as specified and directed. NOTE: Excavation and earth work will be measured and paid separately.
All as per item No above but 120.00 here in before but 16 Sqmm 2 core.
All as per item No above but 120.00 here in before but 25 Sqmm 4 core.
All as per item No above but 120.00 here in before but 240 Sqmm 3.5 core.
Supply and spread sand in trenches as sand cushioning to underground cable for protection with fine river sand and provide required cover after punning down complete all as specified and directed. (Note: Thickness of sand cushion after punning down will be measured and paid.)
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type I, flat, size 250 mm x 150mm x 40mm laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and directed.
Supply and fix LED street light 45 watt, 230 volts with IP-66 protection inclusive all incoming & outgoing electric connection and testing for entire satisfaction of Engr-in-Charge. Cat Part No ENDURACITYLINERNEXGENSL45WLED757 SASYBOPC of make Havells, Surya Cat Part No SLE UL 45 W IP66 LXN, Bajaj Cat No BRTFG 45W LED WW or equivalent in Phillips.
Supply and fixing of LED flood light fittings in die cast aluminium PDC housing, toughened glass cover, individual LEDs with secondary optics, covered with IP66 protection with inbuilt surge protection of minimum 5 kV of capacity 30W inclusive all incoming & outgoing electric connection and testing for entire satisfaction of Engr-in-Charge. Make: Surya SLE FL 30W or its equivalent in Havells/Philips/Bajaj . Note: Price of GI bracket, clamps, nut bolts etc to fix flood light on channel sign board as required at site and directed by engr in charge shall be deemed to be included in the quoted rate.
Supply and fix new generation, Bollard of 8 W (minimum), energy saving , environment friendly, long life with IP 65 protection inclusive all incoming & outgoing electric connection and testing for entire satisfaction of Engr-in-Charge and taking down old one . Make: Halonix Cat No. HLOB-02-10-CW or Havells Cat No CONEBL8WLED857SSYMTOPC, Bajaj Cat Part No BGBOL6059WLED.
S&F for 32 mm dia GI tubing light grade bracket over all 1.2 mtr length with cutting as required and bend to shape with flat iron clamp of size 32 mm 2 Nos, suitable size of nut bolts and washers complete for fixing street light fittings on electric poles including taking down old one complete all as specified and directed.
Supply and fix in repair of PVC cable junction box IP66 "Halogen free and weather proof" of size 155x210x92mm consisting of 01 No MCB 10 Amps SP, 10 KA capacity including aluminium strip bus bar for incoming and outgoing cables upto 10 to 16 sqmm with necessary connection duly fixed on the pole/wall with suitable size of MS clamp as approved and directed. Make : Hensal Cat No. KF1616 B or its equivalent in Sintex/ Havells.
M & L for plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation of pole / strut etc including necessary form work all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping/benching inclusive of weathering slightly chamfered on edge and finishes exposed surfaces even smooth without using extra cement including necessary form work /mould etc. and complete all as specified & directed.
Supply & fix single pointed air termination Copper rod 12mm dia, 300 mm long all as specified and as directed.
S&F test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 Nos, 8mm dia 25mm long hexagonal head brass screws including suitable sheet metal powder coated enclosure complete all as specified and as directed.
Supply & fix aluminium strip 25mm x 3mm complete with saddles and fixing screws for fitting the strip complete all as specified and as directed.
Supply and fix in repair on pole / wall or lay in trenches under road / drain crossings etc for drawing cables, GI pipe light grade 40 bore dia including necessary fittings ,clamps, bolts , nuts etc. complete all as specified and as directed.
Supply and fix in repair on pole / wall or lay in trenches under road / drain crossings etc for drawing cables, GI pipe light grade 80 bore dia including necessary fittings ,clamps, bolts , nuts etc complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6.00 mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron strip of size 32x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point all as specified and testing on completion including provision of earth lead protected by 40 mm bore light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, charcoal, salt, funnel etc complete.
Supply & fix Galvanised iron strip 32 x 6mm complete with saddles and fixing screws for fitting the strip complete all as specified and as directed.
M & L for design, supply, fabrication and fixing of sign board (8 ft x 4ft) using words made of acrylic cut out letters with LED and reflective vinyl sheet as per approved design with following specification :- (a) Board shall be fabricated with 3mm thick ACP sheets of indobound or equivalent make. Powder coated Aluminium sheet shall be fixed from the rear side of the entire board to make box section. (b) letters "JACKWELL PUMP HOUSE (GE UMROI)" shall be made of Acrylic cut-out letters of ACAST or equivalent make and shall be uniformly illuminated by using Digital LED light of Samsung or equivalent make. (c) Powder coated Aluminium clips and brackets shall be used of minimum 3mm thickness as per direction of Engineer-in-Charge. Note: Approval for design of the sign board shall be taken by contractor from engr-in-charge at the time of execution complete all as specified and directed including taking down old unserviceable one .
M&L for fabrication and fixing of letters "JACKWELL PUMP HOUSE" (total 17 letters all capital) on a support structure of MS ( to be measured and paid separately). The letters shall be fabricated from stainless steel sheet of grade SS 304 of minimum thickness of 0.5mm in 3D of minimum height of letter 30 cm and depth of 25mm. The letters shall be fixed with the help of stainless steel screws/studs to supporting structure. Note : MS support structure of stainless steel sign board and its connected earthwork shall be measured and paid extra
S&F Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified and directed.
Supply, installation, testing and commissioning of LT panel board not less than 1.5m x 2.0m x0.60 m , indoor cubical type factory made (CPRI approved) ,single hinged type door for individual MCCBs rubberised gasket, front & back side openable type with locking arrangement (locking arrangement should be screw type), fabricated from CRCA sheet 2 mm thick supported on 50x 50 x 6 mm angle iron and Tee section frame dust and vermin proof complete with aluminium bus bar 4 Nos, 600 Amps rated capacity mounted on porcelain insulators totally enclosed chamber for protection 3 phase 415 volt with suitable capacity aluminium bus bar / PVC insulated copper cable of size 6 sqmm for control wiring duly mounted on PCC floor with suitable size of bolts, nuts & washers. Panel board shall be powder coated and angle iron frame painted with black synthetic enamel paint over a coat of red oxide primer complete, connecting existing cables with suitable size glands and lugs to accommodate and including taking down old one. Note : (i) foundation and PCC work to be included in the quoted price and the rate quoted against these items included :- (a) MCCB 400 Amps with adjustable type 4 pole 415 Volts - 1 No (Incoming) Make : L&T, Legrand, ABB (b) MCCB 160 Amps with adjustable type 4 pole 415 Volts - 5 Nos (outgoing) Make : L&T, Legrand, ABB (c) Bus bar Aluminium 600 Amps - 4 Nos (d) Indicator LED lamp R Y B - 1 No (Set of three) (e) LED Multifunction meter(Tri vectrometer) Model A, class 0.5 S,RS485 port Make L&T, HPL, C&S (f) Space for Onload changeover 400 Amps - 1 No (g) Space for Soft Starter 50 HP/37KW (EMX3-0076B) for 50 HP induction motor/pump - 04 Nos (h) space for Soft Starter 60 HP/45KW (EMX3-0097B) for 60 HP induction motor/pump - 01 No
Supply and fix in repair onload manual changeover open execution 400A, 415V, AC 23 A, 4P complete all as specified and directed . Make L&T, Legrand, ABB, Note : onload changeover to be fixed in above LT panel.
Supply and fix in repair soft starter for 50 HP/37KW three phase 415V 76A, 110-440V CRTL Keypad soft starter including motor protection circuit breaker upto 11 KW complete with short circuit, over load, single and reverse phasing, over voltage and under voltage protection complete all as specified and directed. Make L&T Cat No. (EMX3-0076B-411), or its equivalent in Crompton, ABB Note : Soft starter to be fixed in above LT panel.
Supply and fix soft in repair starter for 60 HP/45KW three phase 415V 97A, 110-440V CRTL Keypad soft starter including motor protection circuit breaker upto 11 KW complete with short circuit, over load, single and reverse phasing, over voltage and under voltage protection complete all as specified and directed. Make L&T Cat No. (EMX3-0097B-411), or its equivalent in Crompton, ABB. Note : Soft starter to be fixed in above LT panel.
Taking down carefully aluminium point wiring (light, fan socket or power) complete including fittings & fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of walls, floors etc complete all as directed.
Taking down carefully MCB DBs SP/TP by unscrewing from main switch boards/cut out boxes and removing materials to store for keeping in safe custody for reuse at site or for taking credit including sealing the cable ends and making good disturbed surface of wall etc as per existing finishes complete all as specified and directed.
M&L point wiring with 1.5 Sqmm (nominal area) PVC insulated1100 volts grade, multistranded, copper conductor, single core, unsheathed cables (FRLS quality) drawn through and including PVC conduits of suitable size but not less than 20 mm dia (medium grade) with all fittings and accessories concealed in walls/ceiling etc including cutting chases for conduits and sinking for boxes and making good to disturbed surfaces including sunk mild steel terminal box with 3mm thick plastic laminated sheet top cover for mounting switches, sockets, regulators etc including PVC insulated and unsheathed, single core, multi-stranded, copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for one light point / fan point/ one call bell point controlled by one 5 Amps one way switch complete as specified and directed. Note : Quoted rate shall be inclusive of necessary chasing and cutting and making good .
All as per item No 151 above but one 3 pin socket outlet 5 Amps, on the same board with other switches.
All as per item No 151 above but one 3 pin socket outlet 5 Amps, on independent board.
All as per serial item No. 151 above but for one light point controlled by two way switch complete all as specified and directed.
All as per item No 151 here-in-before but point wiring for one 3/5 pin 15 Amps socket point on independent board with 2.5 Sqmm size PVC insulated, unsheathed, multi stranded, copper conductor cables and with 2.5 Sqmm PVC insulated unsheathed, single core, multistranded copper conductor cable as earth wire complete as specified and directed.
Supply and fixing bell push,6 Amp, flush type, single pole, one way 230 volts, complete all as specified and directed.
Supply and fixing switch piano,6 Amp, flush type, single pole, one way 230 volts, complete all as specified and directed.
Supply and fixing of switch piano flush type 240 volts 5 Amps, SP two way complete all as specified and directed
S & F socket outlet 5 Amps,3/5 pin flush type complete all as specified and directed.
S & F switch socket combination 2 in 1, 5 Amps, 3/5 pin, flush type complete all as specified and directed.
S & F switch socket combination 2 in 1, 3/5 pin, 5 and 15/16 Amps, flush type complete all as specified and directed.
S & F ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed.
S & F stepped type electronic fan regulator, flush type (ISI mark), 240 volts complete all as specified and directed.
Supply and fixing Bulb angular/batten holder PVC/Polycarbonate suitable for batten fittings including one No LED Lamp of 9W of Havells/Philips/Crompton complete all as specified/directed.
Supply and fixing call bell electric, 240 Volts, single pole type ding dong complete all as specified and directed
Supply and fixing LED fitting 1x18 watts including Tube rod, 230 Volts, bipin holders connector block etc. complete with all accessories internally pre-wired and including provision of PVC round block 7.5cm dia and 2 cm in depth (2 Nos) for mounting the fittings and electrically connecting with three single core 23x0.0076 PVC insulated multistranded copper conductor flexible cable from ceiling rose to light fitting, complete all as specified and directed. Make: BAJAJ Cat Part No: BLRB- DB 118 for batten and BLRB-18 Watt CWc XE LED for tube light, or Surya Cat Part No SUB 118 T8 LED FOR Batten and Cat No SLE TL -DS 18 PC REFORM for Tube or its equivalent in Philips/Havells
Supply and fixing in repair of MCB TPN DB 4 way double door,IP-43 protection, isolated neutral bar, insulated busbar assembly, mechanical impact strength of IK09 complete all as specified and directed by Engr-in-charge.
Supply and fixing sheet metal enclosure for MCB’s distribution board, 240 Volts, 08 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door complete and fix all as directed by the Engineer-in-Charge.
Supply & fixing in repair of MCB TPN 63 Amps 'C' Series 10 KA 415 volts complete all as specified/directed.
Supply & fixing in repair of MCB SPN 32 Amps 'C' Series 10 KA 240 volts complete all as specified/directed.
Supply & fixing in repair of MCB SP 6-32 Amps 'C' Series 10 KA, 240 volts complete all as specified/directed.
Material and labour for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised wire of dia 4 mm as earthing lead by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 15 mm bore (light grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1(using 20 mm graded aggregate) and pre-cast RCC cover slab of size 540 x 540 x 50 mm thick, reinforced with 8 mm dia TMT bars both ways and one handle for lifting made with 10 mm dia mild steel bar, funnel, wire mesh 20 mm bore galvanised (light grade) for watering, charcoal and salt in alternate layers including necessary execution and earth works in any types of soil complete all as shown on Electrical plate No 3 of MES SSR-I including taking out the old earthing material complete all as specified and directed.
Material & labour for concealed Sub main wiring with two runs of single core 6 Sqmm (Nominal Area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 volts grade drawn through and including PVC conduit of adequate size (minimum 20mm) of wall/ceiling with all necessary fittings and accessories and 1 run of FRLS PVC insulated and unsheathed insulated single core cable with multi stranded copper conductor of size 6 Sqmm as earth wire (green in colour) run throughput conduit and connected to common earth dolly including taking out the old sub main wiring complete all as specified and directed. Note : (a) Two run of cable, one run earth wire and one run of PVC conduit will be measured as one length. (b) Rate shall be inclusive for necessary chasing and cutting and making good to surfaces to match the existing surfaces.
Supply & fix exhaust fans AC single phase 230/ 240 V copper wound, heavy duty, metallic body of size 300 mm sweep with louver all as specified and directed.
M&L for cutting of circular hole finishing with painting/distempering/whitewashing on any type of wall suitable size for fixing of exhaust fan of size 300mm sweep, grouting 04 Nos 100mm long 12mm dia stud bolt including, making good to disturbed surfaces of wall and with to match as per the existing colour complete all as directed and specified by engineer-in-charge.
Taking down the defective turbine pump sets of capacity 50 HP by dismantling the electrical connection and motor, removing the old column pipe with pump sets and including all accessories from bed complete all as directed by Engr-in-charge.
Supply, fixing and testing in repair the ERW Steel heavy duty column assembly pipe of 200 mm dia (length of six pipe should be 3m each and two pipes of 1.5m each) set suitable for 50 HP turbine pump set No. 3010505. Make WPIL. Note: If the spare part is not manufactured by WPIL only then any other equivalent reputed make compatible with existing turbine shall be approved by GE. In such a scenario non manufacturing certificate from WPIL shall be produced and purchase voucher shall also be produced.
Supply and fixing in repair MS Galvanized Pipe plug as per existing size fitted at the bottom of shaft suitable for 50 HP turbine pump set No. 3010505. Make WPIL. Note: If the spare part is not manufactured by WPIL only then any other equivalent reputed make compatible with existing turbine shall be approved by GE. In such a scenario non manufacturing certificate from WPIL shall be produced. Production of purchase voucher from manufacturer or its authorised dealer for the part shall be mandatory before payment.
Supply and fixing in repair the Discharge case bearing of existing model and size suitable for 50 HP turbine pump set No. 3010505. Make WPIL. Make WPIL. Note: If the spare part is not manufactured by WPIL only then any other equivalent reputed make compatible with existing turbine shall be approved by GE. In such a scenario non manufacturing certificate from WPIL shall be produced. Production of purchase voucher from manufacturer or its authorised dealer for the part shall be mandatory before payment.
Supply and fixing in repair the CI discharge case of existing model and size suitable for 50 HP turbine pump set No. 3010505. Make WPIL. Make WPIL. Note: If the spare part is not manufactured by WPIL only then any other equivalent reputed make compatible with existing turbine shall be approved by GE. In such a scenario non manufacturing certificate from WPIL shall be produced. Production of purchase voucher from manufacturer or its authorised dealer for the part shall be mandatory before payment.
Supply and fixing in repair the stainless steel pump shaft of grade 410 of existing model and size suitable for 50 HP turbine pump set No. 3010505. Make WPIL. Note: If the spare part is not manufactured by WPIL only then any other equivalent reputed make compatible with existing turbine shall be approved by GE. In such a scenario non manufacturing certificate from WPIL shall be produced. Production of purchase voucher from manufacturer or its authorised dealer for the part shall be mandatory before payment.
Supply and fixing in repair the pump shaft coupling of existing model and size suitable for 50 HP turbine pump set No. 3010505. Make WPIL. Note: If the spare part is not manufactured by WPIL only then any other equivalent reputed make compatible with existing turbine shall be approved by GE. In such a scenario non manufacturing certificate from WPIL shall be produced. Production of purchase voucher from manufacturer or its authorised dealer for the part shall be mandatory before payment.
Supply and fixing in repair heavy duty MS column coupling of size 200mm suitable for 50 HP turbine pump set No. 3010505. Make WPIL. Note: If the spare part is not manufactured by WPIL only then any other equivalent reputed make compatible with existing turbine shall be approved by GE. In such a scenario non manufacturing certificate from WPIL shall be produced. Production of purchase voucher from manufacturer or its authorised dealer for the part shall be mandatory before payment.
Supply and fixing in repair Cast iron Bearing retainer of existing model and size to hold rubber bearing suitable for 50 HP turbine pump set No. 3010505. Make WPIL. Note: If the spare part is not manufactured by WPIL only then any other equivalent reputed make compatible with existing turbine shall be approved by GE. In such a scenario non manufacturing certificate from WPIL shall be produced. Production of purchase voucher from manufacturer or its authorised dealer for the part shall be mandatory before payment.
Supply and fixing in repair the Rubber bearing fixed in bearing retainer suitable to hold the inner line shaft as per existing model and size for 50 HP turbine pump set No. 3010505. Make WPIL. Note: If the spare part is not manufactured by WPIL only then any other equivalent reputed make compatible with existing turbine shall be approved by GE. In such a scenario non manufacturing certificate from WPIL shall be produced. Production of purchase voucher from manufacturer or its authorised dealer for the part shall be mandatory before payment.
Supply and fixing in repair stainless steel Line shaft sleeve of grade 410 of existing model and size suitable for 50 HP turbine pump set No. 3010505. Make WPIL. Note: If the spare part is not manufactured by WPIL only then any other equivalent reputed make compatible with existing turbine shall be approved by GE. In such a scenario non manufacturing certificate from WPIL shall be produced. Production of purchase voucher from manufacturer or its authorised dealer for the part shall be mandatory before payment.
Supply and fixing in repair stainless steel line shaft coupling of grade 410 of existing model and size suitable for 50 HP turbine pump set No. 3010505. Make WPIL. Note: If the spare part is not manufactured by WPIL only then any other equivalent reputed make compatible with existing turbine shall be approved by GE. In such a scenario non manufacturing certificate from WPIL shall be produced. Production of purchase voucher from manufacturer or its authorised dealer for the part shall be mandatory before payment.
Supply and fixing in repair the stainless steel inter line shaft of grade 410 (length of six inter line shaft should be 3m each and two inner line shaft of 1.5m each) of existing model and size suitable for 50 HP turbine pump set No. 3010505. Make WPIL. Note: If the spare part is not manufactured by WPIL only then any other equivalent reputed make compatible with existing turbine shall be approved by GE. In such a scenario non manufacturing certificate from WPIL shall be produced and purchase voucher shall also be produced.
Supply and fixing in repair the Adjusting nut - 1 no. suitable for 50 HP turbine pump set No. 3010505.Make WPIL. Note: If the spare part is not manufactured by WPIL only then any other equivalent reputed make compatible with existing turbine shall be approved by GE. In such a scenario non manufacturing certificate from WPIL shall be produced and purchase voucher shall also be produced.
Material and labour for Replacement of RO Membrane Hydramem 4040 BWE of existing make and model complete all as specified and directed. Note:- production of purchase voucher for the material shall be mandatory.
Material and labour for Replacement of filter Sand of NGMF-20 filter of existing make and model complete all as specified and directed. Note:- production of purchase voucher for the material shall be mandatory.
Material and labour for Replacement of Gravel of NGMF-20 filter of existing make and model complete all as specified and directed. Note:- production of purchase voucher for the material shall be mandatory.
Material and labour for Replacement of Activated carbon of NGMF-20 Filter of existing make and model complete all as specified and directed. Note:- production of purchase voucher for the material shall be mandatory.
Supply and fix 200mm sluice valves IS-14846, flanged of class 1.6 PN with brass spindle with hand wheel complete all as specified and directed.
Supply and fix 150mm sluice valves IS-14846, flanged of class 1.6 PN with brass spindle with hand wheel complete all as specified and directed.
Supply and fixing of Electromagnetic water flow meter of 300 mm dia ISI marked with jointing material flanged joint rubber gasket 6 mm thick , MS nuts, bolts, washers including taking out of existing unserviceable complete all as specified and as directed.
Supply and fixing of cast iron non return valve of 200 mm dia (heavy duty) with jointing material flanged joint rubber gasket 6 mm thick nuts, MS nuts, bolts, washers including taking out of existing unserviceable complete all as specified and as directed.
Supply and fixing of cast iron non return valve of 150 mm dia (heavy duty) with jointing material flanged joint rubber gasket 6 mm thick nuts, MS nuts, bolts, washers including taking out of existing unserviceable complete all as specified and as directed.
Taking up CI water mains of size 400 mm bore (including all fittings), with spigot and socket ends and lead joints including burning out joints wherever applicable complete all as specified and directed.
Supply and laying of Cast iron pipes Class "A", 400 mm(16") dia with spigot and socket ends centrifugally cast ,in any length, laid in trenches, surface on PCC foundation as required at site Class "A", 400 mm(16") dia complete all as specified and directed. Note : earth work, PCC, Lead joints and specials shall be measured and paid separately.
M&L PCC 1:2:4 type B2 (using 40 mm graded stone aggregate) as in foundation, mass concrete etc complete all as directed by Engr-in-Charge
M&L for run lead joint for spigot and socket pipe of size 400 mm and fittings all as specified and directed by Engr-in-Charge
M&L for CI fitting upto 400 mm bore such as bends (any type, radius and angle) tapers any type, bends, tee pieces single branch Y junction double branch cross (all socket or socket and spigot) collar cap and plugs suitable for the following size of bore for spigot and socket pipes complete all as specified and directed by Engr-in-Charge.
Labour and T&P for desilting of Jack well manually and removing sand upto a depth not more than 25 mtr, turning ON/OFF water without damage of existing plant and machinery as per time requirement and as directed by Engineer-in-charge. Note: Contractor will arrange Desilting pump and all T&P as required on site to complete the work all as specified and directed.
MOINUL HOQUE CHOUDHURY
Arbind Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .