Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.2 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹45.6 L+₹79,055 (1.76%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹47.5 L+₹2.7 L (5.96%)Rejected-Finance OPP MARUTI SERVICE CENTRE SARACHARMA POST SRI VIJAYA PURAM 744 105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹47.6 L+₹2.8 L (6.25%)Rejected-Finance NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹50.1 L+₹5.3 L (11.7%)Rejected-Finance 956 2 CHANDERSEKER ENTERPRISE OPP MARICAR HOSPITAL OLD CCS JUNGLIGHAT SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
16 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Haddo Port Blair
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
PERIODICAL SERVICES TO CERTAIN BLDGS AT NSRY, NAVCC, CDU, MES COLONY AND VIJAY BAUGH UNDER AGE B/R-II AT GE HADDO PORT BLAIR
2022_MES_541428_1
8651/GE/H/PB
Open Tender
Civil Works
Item Rate
270 days
GE Haddo Port Blair
Class D Category a(i)
10 documents required · 10 mandatory
₹500
GE Haddo
₹96,000
Yes
20 Sept 2022
27 Jul 2022
23 Aug 2022
27 Jul 2022
16 Aug 2022
11 Aug 2022
27 Jul 2022 - 4 Aug 2022
Amount
Demolition of cement concrete (un reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) and removing the debris and cleaning the premises complete all as specified and as directed.
Dismantling of PCC block walling built in cement mortar of cement lime mortar complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc., complete all as specified and as directed.
Dismantling of ceiling boarding including grid of any description, fixed in any position with nails complete all as specified.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons, risers of steps, skirting, dado etc., laid bedded and pointed in any mortar complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames), area not exceeding 1.5 Sqm each complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames), area exceeding 1.5 Sqm but not exceeding 4.0 Sqm each complete all as specified and as directed.
Taking down shutters of any description, area exceeding 1.0 Sqm but not exceeding 2.0 Sqm each complete all as specified and as directed.
Taking down shutters of any description, area exceeding 1.0 Sqm but not exceeding 2.0 Sqm each and re-fixing in the same opening complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, bed plates, kerbs etc., including necessary form work, exposed surfaces of concrete finished even and smooth without using extra cement complete all as specified and as directed. NOTE: Reinforcement will be measured and paid separately under relevant items of this BOQ.
M&L for pre-cast reinforced cement concrete (1:1½:3) type A1 (using 20mm graded stone aggregate) as in cover slabs for drains, man holes etc., using necessary form work set in CM(1:6) including placing the cover slabs after thay are casted, set, cured and tested completely at required locations without causing damage to either slabs or to other existing structures complete all as specified and as directed. NOTE: Reinforcement will be measured and paid separately under relevant items of this BOQ.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry not exceeding 10cm in width and setting in cement mortar (1:4) complete all as specified and directed.
S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based corrugated / trapezoidal section steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including scaffolding for a height upto 12.0 metres complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.
S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/valley gutters, fixed with self tapping screws including scaffolding for a height upto 12.0 metres complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.
M&L for anodised aluminium snap grid frame work for false ceiling with size of grid 605mm x 605mm all as specified in SSR Part-I 2009, hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat iron 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including cutting, drilling, jointing etc., 6mm thick non-asbestos fibre cement building design boards fixed or laid/ inserted to aluminium frame work with screws and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed.
S&F in repairs plain aluminium flat section not less than 0.68 Kg per RM as in wind tie and for verticle and horizontal support fixed with aluminium self tapping screws etc complete all as specified and as directed
M&L for gypsum board false ceiling made out of 1200x1200mm size, 12mm thick board of gypsum siliceous and calcareous material reinforced with cellulose fiber fixed to the ceiling section 25mm long self drilling/tapping screws having Philips head with under head cutter at 200mm c/c, including finishing the joints of board with specially formulated joining compound and 48 mm wide fibre tape to provide seam less finish and including GI channel 18 Gauge thick grid work, main joists placed at 750mm c/c, secondary joints placed at 450mm c/c, GI angle suspenders from roof and treating with thin layer of Pop with Gypsum binder, sanding the surfaces till smooth surface is obtained and finally applying two coats of oil bound distemper with roller finish over a coat of primer complete all as specified and as directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns/beams, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Mild steel TMT bars 5mm dia and over upto 10mm, as in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns/beams, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for mild steel rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc., conforming to grade Fe 290 (Gde E-165) complete all as specified and as directed.
M&L for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
S&F Second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube as per specification & drawing, fixed in opening in repairs complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing fixed to door frame complete all as specified and as directed.
S&F factory made solid PVC moulded door shutter with particle board core, 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded prelaminated PVC sheet on the front face & 2mm plain colour PVC sheet on back face as per specification & drawing, fixed to door frame complete all as specified and as directed.
S&F 35mm thick second class hard wood plain framed, panelled shutter (two panel) with lock rail and panels of timber flat on both sides (feather edged) or 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces, the size of rail and stile as per IS:1003 (Part I), kiln seasoned and chemically pressure treated, fixed to door frame complete all as specified and as directed.
S&F 35mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a), fixed to chowkats complete all as specified and as directed.
S&F flush shutters 35mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides including 6mm thick wooden lipping around the edges of shutter complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors etc, laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, for work on vertical surfaces such as skirting, dados and risers to steps etc., including 10mm thick backing coat in CM (1:3), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.16 sqm, as in floors etc, laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.16 sqm, for work on vertical surfaces such as skirting, dados and risers to steps etc., including 10mm thick backing coat in CM (1:3), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc, laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, for work on vertical surfaces such as skirting, dados and risers to steps etc., including 10mm thick backing coat in CM (1:3), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for glazed ceramic designed coloured tiles in vertical surfaces using size of tiles 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with colour of tile with and including 10mm thick backing coat in CM (1:3), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for 75mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base of floors complete all as specified and as directed.
M&L for 75mm thick PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in plinth protection, surface of concrete finished even and smooth using extra cement complete all as specified and as directed.
M&L for glossy finished chequered cement concrete tiles 30cm x 30cm x 25mm thick, made of grey cement and pigments, machine pressed as in flooring, set, jointed and pointed in neat cement slurry laid over and including 20mm thick screed bed in CM (1:6) complete all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls etc., including raking out joints, hacking for key, scrubbing down with water etc., and removal of debris to outside MD land complete all as specified and as directed.
M&L for rendering 15mm thick in two coats 5mm thick in CM (1:4) mixed with integral water proofing compound @ 3% by weight of cement over 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed. NOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule.
M&L for 10mm thick plaster in CM (1:6) on fair faces of concrete/PCC block surfaces of walls finished even and smooth (without using extra cement) complete all as specified and as directed.
SUPPLY ONLY integral water proofing compound.
M&L for preparation of old plastered surfaces of walls and applying one coat of cement based paint after filling the cracks/holes and levelling the undulations if any with cement putty complete all as specified and as directed.
M&L for preparation of old plastered surfaces of walls and applying one coat of acrylic distemper oil emulsion after filling the cracks/holes and levelling the undulations if any with cement putty complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls of any description and applying two coats of acrylic distemper oil emulsion over a coat of primer including levelling the undulations if any with cement putty complete all as specified and as directed.
M&L for preparation of old plastered surfaces of ceilings and applying one coat of white wash after filling the cracks with filler complete all as specified and as directed.
M&L for preparation of old plastered surfaces of walls and applying two coats of white wash after filling the cracks with filler complete all as specified and as directed.
M&L for preparation of old steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality complete all as specified and as directed.
M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M&L for preparation of old wooden surfaces of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint of first quality complete all as specified and as directed.
M&L for preparation of new wooden surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality over a coat of pink primer complete all as specified and as directed.
M&L for preparation of old plastered/concrete surfaces of walls of any description over 10cm girth or width, not otherwise described and applying one coat of synthetic enamel paint in stripes of yellow/black colour complete all as specified and as directed.
S&F sliding door bolt, 300mm long, aluminium alloy, anodised, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed.
S&F 150mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.
S&F 150mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
S&F 100mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type B-21 complete all as specified and as directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, overall length of cover plate 150mm complete all as specified and as directed.
S&F door closer, aluminium (extruded section body), hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg, fixed in repairs with screws complete all as specified and as directed.
M&L for anodised aluminium partition, window and door/ventilator with frame and shutters and grill fully or partly glazed, sliding/openable/fixed fully glazed and panels fixed with panels inserts 12 mm thick pre-laminated particle board/sheet glass including necessary jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodized aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts etc. The size of aluminium section shall be all as specified in relevant IS Code and SSR Part-I including taking out old unserviceable ones complete all as specified and as directed. NOTES: (i) Supply only floor spring, glass, Imax hinges, SS friction hinges, particle board, aluminium fly proof mesh will be measured and paid separately under relevant items of this BOQ. (ii) Weight of aluminium section only shall be accounted for the purpose of payment. However unit rate quoted shall be deemed to include for cost of rubber beading, neoprene packing, fittings such as handles, butt hinges, tower bolts, rollers for sliding windows, locking arrangement and fixing only of panel inserts of glass/ particle board/aluminium fly proof mesh etc. (iii) Weight of aluminium handle, butt hinges, tower bolts shall not be accounted for payment purpose.
S&F 4.0 mm thick sheet glass, ordinary quality and glazing with wooden beads/ metal surrounds/ aluminium glazing clips in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S&F 4.8 mm thick sheet glass, ordinary quality and glazing with wooden beads/ metal surrounds/ aluminium glazing clips in square exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S&F 4.0 mm thick figured glass, pin head type and glazing with aluminium glazing clips in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S&F 5.0 mm thick figured glass, pin head type and glazing with aluminium glazing clips in square exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply Only aluminium expanded metal fly proof mesh, cut to required size and shape, with 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed.
S&F aluminium expanded metal fly proof mesh, cut to required size and shape, with 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples, fixed in repairs complete all as specified and as directed.
S&F 12mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination and other side with balancing white lamination, fixed with screws to timber frame work complete all as specified and as directed.
S&F 5 to 6mm thick plain colour PVC sheet in strips & channel feathered at the edges to required size/shape for fixing to aluminium partitions/doors inclusive of solvent cement at site complete all as specified and as directed.
S&F for second class hard wood (Hollock) plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area not exceeding 3 Sqcm complete all as specified and as directed.
S&F in repairs for second class hard wood (Hollock) plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exceeding 13 Sqcm but not exceeding 25 Sqcm complete, fixed in repairs all as specified and as directed.
S&F aluminium grill of approved pattern, anodised cut to required size and shape, fixed in postion with aluminium beading & frame made of aluminium F-section fixed to aluminium windows/ventilators complete all as specified and as directed.
S&F 20mm dia aluminium powder coated curtain rod with fancy type end brackets of any colour, fixed in repairs complete all as specified and as directed.
Taking down of damaged, loosened cement concrete/ cement mortar in walls/soffits of slabs and similar structural members up to depth of 20 to 40mm, cleaning the dismantled portion with wire brush etc remove dust , dirt and other foregin particals etc., and washing with water with pressure and applying bonding agent on old concrete surfaces all as specified and as per manufacturers instructions, over prepared surfaces provide 20mm thick high build polymer modified cement sand mortar (1:2½) mixed with 10 litres (minimum) Nitobond SBR per 50 kilograms of cement of M/s FOSROC Chemical (India ) Pvt Ltd or equivalent in Dr. Fixit or Harjas Coatings & Polymers including necessary scaffolding up to 12.0 m and including matching the existing surface with the shade of surrounding surface complete all as specified and directed.
M&L for preparation of new surfaces of plastered wall surfaces and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed
M&L for preparation of old plastered surfaces of walls and applying one coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm including filling of cracks, holes and levelling the surface which undulation found with cement putty etc complete all as specified and as directed.
Bismi Builders & Enterprises
M/s Ramesh Lal
SKV Engineering
CHANDER SEKER ENTERPRISE
M/s S A Traders
M/s Saina Enterprises
P Babu
Nirman Construction Company
S K ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .