GEMC-511687733811554
Awarded to EXPERIO TECH PRIVATE LIMITED
₹48,226
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Jupiter | alcovisor - jupiter | - | 2 NOS | ₹24,113 | 48,226 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹48,226Qualified Make: Alcovisior
Model: alcovisor - jupiter A 1 130 GROUND FLOOR POLE NO 32 GYAN DEEP SCHOOL PALAMNAV VIJAY ENCLAVE SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | Make: Alcovisior
Model: alcovisor - jupiter | ₹48,226 | L1 | Qualified |
| 2 | L2₹49,948+₹1,722 (3.57%)Qualified Make: Alcovisior
Model: Alcovisor Jupiter A 277 OKHLA INDUSTRIAL AREA PHASE 1 NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | Make: Alcovisior
Model: Alcovisor Jupiter | ₹49,948+₹1,722 (3.57%) | L2 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
4 Oct 2018, 11:00 amClosed
breath alcohol analyzers Breath Alcohol Analyzers ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values TECHNOLOGY PERFORMANCE Sensor Technology ElectroChemical - Fuel Cell (alcohol specific) ElectroChemical - Fuel Cell (alcohol specific)
Semiconducter Alcohol Sensor Sampling Method Deep Lung Exhalation Method * Sampling Error Detection Alarm on wrong sampling * Sampling modes Both Active and Passive * Measuring Range [mg/100 ml BAC (Blood Alcohol Concentration)] 0 to 500 0 to 400
0 to 500
0 to 600 Accuracy +/- 5 % or better * Drift of the breath analyzer in 6 months period (mg/100 ml BAC) 0 Any applicable numeric value Easily replaceable yes * 1/5 mouthpiece with Sputum Trap Sample Taking Duration 4 * Analytical Response Time (At '0' level of Alcohol) 5 * Analytical Response Time for positive result 8 * Recovery Time at (1/2) mg/ltr 1 * Warm up Time (after putting on) 9 * Time required for re- calibration 6 * Barometric Pressure Range (hpa or millibar) 1100 * Shelf Life of Fuel Cell 2 * RoHS Compliant true * The Equipment meet RFI requirement as per EN:5008-1/1992(emissi on) and EN 50082-1:19 97(immunity) or equivalent requirements true * PHYSICAL Weight 433 * Size ( mm x mm x mm ) 195 x 75 x 35 * BATTERY OF ANALYZER Power Source Rechargeable Battery and also work through automobile 12 V DC Power. * Chemistry of Rechargeable Battery Li-ion * Battery Voltage 7.4 * Battery Backup Time (continuous duty) 27 * Number of Spare Rechargeable Batteries supplied with the instrument 1 * Low Battery indication yes * DISPLAY/INDICATOR STORAGE/INTERFACE Display Type TFT LCD * Display Size 3.2 * Availability of audible yes * 2/5 beeper for over range
low battery etc Record Entry Through Integrated/Touch Screen Through Integrated/Touch Screen
Through Alphanumeric KeyBoard Minimum Record Fields Full Information as per the user's requirement such as Driver Name
Vehicle number
inspector name
test report with time
date
geolocation
instrument id
etc * Record Memory (Minimum) 50000 20000
50000
30000 Record Data Downloadable to PC yes * Data Interface USB
Wifi
Bluetooth * GPS true * If yes
Capable to display the geolocation of test inspection location yes * Camera false true
false If yes
Capable to capture the clear image of test target yes * PRINTER Printer With With
Without Type of Printer Internal Thermal Printer Portable Dot Matrix Printer with Wireless Bluetooth Connectivity
Portable Inkjet Printer with Wireless Bluetooth Connectivity
Portable Laserjet Printer with Wireless Bluetooth Connectivity
Internal Thermal Printer
NA Print Resolution (dpi) 250 * Printer consists of Inbuilt Rechargeable Battery
Paper for offence printouts
Charger NA * Minimum number of printouts that can be taken with the paper 1 * 3/5 available with the Printer "Minimum number of printouts that can be taken with single charge of the printer battery (Hint:- Minimum 60 prints
if 'With Printer' May indicate '0' if not applicable)" 55 * Bis Registration number for Printer under CRS of MeitY N/A * WARRANTY Warranty 2 1.0
2.0 (or higher) STATUTORY REQUIREMENTS The equipment can be used as an evidential instrument for Traffic Law Enforcement
The instrument is hand held
portable and easy to operate true * If Yes
the equipment meets the requirements of the applicable latest Central Motor Vehicle Rules and all Govt notifications yes * Immunity to RF interface
meets requirement as per EN: 5008-/1992(emission) and EN:50082-1:1997 (immunity) or equivalent yes * OPERATING CONDITIONS Minimum Operating Temperature -10 * Maximum Operating Temperature 50 * Relative Humidity Non Condensing (%) 95 * ENVIRONMENTAL CERTIFICATION Conformity to Dry Heat test at 50 degree C for 16 hours as per IS :9000 latest true * Conformity to Damp heat at 40 degree C - 95% RH (cyclic test): two cycles of 16+8 hours as per IS: 9000 true * 4/5 latest Conformity to Cold test at - 5/-10/- 15/-20 degree C (as applicable) for 4 hours as per IS: 9000 latest true * Availability of Test Reports from Central Govt/NABL approved ILAC accredited Lab to prove conformity to the specification true * Test Report Number and Date NHTSA DATED 14 JUNE 2012 * Name of the Lab and Address US DEPARTMENT OF TRANSPORT ADD: 1200 New Jersey AVENUE SE
Washington DC 20590 * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ashok Kumar Bastia 759102
MAHANADI COALFIELDS LIMITED
AT/PO: Deulbera Colliery
Dist: Angul-759102 2 30
643798
GEM/2018/B/91360
GeM Contract
breath alcohol analyzers
GeM Contract
30 days
Odisha; Anugul
PRODUCT
Awarded to EXPERIO TECH PRIVATE LIMITED
₹48,226
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Jupiter | alcovisor - jupiter | - | 2 NOS | ₹24,113 | 48,226 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| breath alcohol analyzers Breath Alcohol Analyzers ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values TECHNOLOGY PERFORMANCE Sensor Technology ElectroChemical - Fuel Cell (alcohol specific) ElectroChemical - Fuel Cell (alcohol specific) | - | - | - |
| Semiconducter Alcohol Sensor Sampling Method Deep Lung Exhalation Method * Sampling Error Detection Alarm on wrong sampling * Sampling modes Both Active and Passive * Measuring Range [mg/100 ml BAC (Blood Alcohol Concentration)] 0 to 500 0 to 400 | - | - | - |
| 0 to 500 | - | - | - |
| 0 to 600 Accuracy +/- 5 % or better * Drift of the breath analyzer in 6 months period (mg/100 ml BAC) 0 Any applicable numeric value Easily replaceable yes * 1/5 mouthpiece with Sputum Trap Sample Taking Duration 4 * Analytical Response Time (At '0' level of Alcohol) 5 * Analytical Response Time for positive result 8 * Recovery Time at (1/2) mg/ltr 1 * Warm up Time (after putting on) 9 * Time required for re- calibration 6 * Barometric Pressure Range (hpa or millibar) 1100 * Shelf Life of Fuel Cell 2 * RoHS Compliant true * The Equipment meet RFI requirement as per EN:5008-1/1992(emissi on) and EN 50082-1:19 97(immunity) or equivalent requirements true * PHYSICAL Weight 433 * Size ( mm x mm x mm ) 195 x 75 x 35 * BATTERY OF ANALYZER Power Source Rechargeable Battery and also work through automobile 12 V DC Power. * Chemistry of Rechargeable Battery Li-ion * Battery Voltage 7.4 * Battery Backup Time (continuous duty) 27 * Number of Spare Rechargeable Batteries supplied with the instrument 1 * Low Battery indication yes * DISPLAY/INDICATOR STORAGE/INTERFACE Display Type TFT LCD * Display Size 3.2 * Availability of audible yes * 2/5 beeper for over range | - | - | - |
| low battery etc Record Entry Through Integrated/Touch Screen Through Integrated/Touch Screen | - | - | - |
| Through Alphanumeric KeyBoard Minimum Record Fields Full Information as per the user's requirement such as Driver Name | - | - | - |
| Vehicle number | - | - | - |
| inspector name | - | - | - |
| test report with time | - | - | - |
| date | - | - | - |
| geolocation | - | - | - |
| instrument id | - | - | - |
| etc * Record Memory (Minimum) 50000 20000 | - | - | - |
| 50000 | - | - | - |
| 30000 Record Data Downloadable to PC yes * Data Interface USB | - | - | - |
| Wifi | - | - | - |
| Bluetooth * GPS true * If yes | - | - | - |
| Capable to display the geolocation of test inspection location yes * Camera false true | - | - | - |
| false If yes | - | - | - |
| Capable to capture the clear image of test target yes * PRINTER Printer With With | - | - | - |
| Without Type of Printer Internal Thermal Printer Portable Dot Matrix Printer with Wireless Bluetooth Connectivity | - | - | - |
| Portable Inkjet Printer with Wireless Bluetooth Connectivity | - | - | - |
| Portable Laserjet Printer with Wireless Bluetooth Connectivity | - | - | - |
| Internal Thermal Printer | - | - | - |
| NA Print Resolution (dpi) 250 * Printer consists of Inbuilt Rechargeable Battery | - | - | - |
| Paper for offence printouts | - | - | - |
| Charger NA * Minimum number of printouts that can be taken with the paper 1 * 3/5 available with the Printer "Minimum number of printouts that can be taken with single charge of the printer battery (Hint:- Minimum 60 prints | - | - | - |
| if 'With Printer' May indicate '0' if not applicable)" 55 * Bis Registration number for Printer under CRS of MeitY N/A * WARRANTY Warranty 2 1.0 | - | - | - |
| 2.0 (or higher) STATUTORY REQUIREMENTS The equipment can be used as an evidential instrument for Traffic Law Enforcement | - | - | - |
| The instrument is hand held | - | - | - |
| portable and easy to operate true * If Yes | - | - | - |
| the equipment meets the requirements of the applicable latest Central Motor Vehicle Rules and all Govt notifications yes * Immunity to RF interface | - | - | - |
| meets requirement as per EN: 5008-/1992(emission) and EN:50082-1:1997 (immunity) or equivalent yes * OPERATING CONDITIONS Minimum Operating Temperature -10 * Maximum Operating Temperature 50 * Relative Humidity Non Condensing (%) 95 * ENVIRONMENTAL CERTIFICATION Conformity to Dry Heat test at 50 degree C for 16 hours as per IS :9000 latest true * Conformity to Damp heat at 40 degree C - 95% RH (cyclic test): two cycles of 16+8 hours as per IS: 9000 true * 4/5 latest Conformity to Cold test at - 5/-10/- 15/-20 degree C (as applicable) for 4 hours as per IS: 9000 latest true * Availability of Test Reports from Central Govt/NABL approved ILAC accredited Lab to prove conformity to the specification true * Test Report Number and Date NHTSA DATED 14 JUNE 2012 * Name of the Lab and Address US DEPARTMENT OF TRANSPORT ADD: 1200 New Jersey AVENUE SE | - | - | - |
| Washington DC 20590 * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ashok Kumar Bastia 759102 | - | - | - |
| MAHANADI COALFIELDS LIMITED | - | - | - |
| AT/PO: Deulbera Colliery | - | - | - |
| Dist: Angul-759102 2 30 | - | - | - |
Exempted
19 Nov 2018
23 Sept 2018
contract_GEMC-511687733811554.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_643798.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .