Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.1 LAccepted-AOC AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹41.4 L+₹1.4 L (3.40%)Rejected-Finance 01 CHANGSARI KAMRUP ASSAM 781101 | KAMRUP | ASSAM | 781101 | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹44.0 L+₹4.0 L (9.94%)Rejected-Finance PO PS BANDERDEVA DIST PAPUM PARE ARUNACHAL PRADESH PIN 791123 | PAPUM PARE | ARUNACHAL PRADESH | 791123 | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹44.9 L+₹4.8 L (12.1%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹45.7 L+₹5.7 L (14.2%)Rejected-Finance GUIJAN GAON WARD NO 3 C O RAJKHOWA HOUSE P O RANGAGORA DIST TINSUKIA ASSAM PIN 786147 | TINSUKIA | ASSAM | 786147 | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹46.7 L
EMD Value
₹93,340
Closing Date
19 May 2025, 6:00 pmClosed
GE 872 EWS
GE 872 EWS, C/O 99 APO
REPAIR AND MAINT TO LT EXTERNAL ELECTRIFICATION ALONGWITH LT OVERHEAD LINE CONDUCTOR, STAY ASSEMBLY, INSULATORS, LT POLES, POLE PAINTING AND CONNECTED ITEMS AT RAYANG MIL STN UNDER GE 872 EWS
2025_MES_705596_1
8740/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
RAYANG
All as per NIT and Tender documents
7 documents required · 7 mandatory
₹500
GE 872 EWS
₹93,340
Yes
23 Jun 2025
26 Apr 2025
21 May 2025
26 Apr 2025
19 May 2025
12 May 2025
Amount
Dismantling of unserviceable broken LT steel pole/Strut any size including demolition of foundation as required and making good disturbed surface complete all as directed. (Note : Earth work wherever invloved shall be measured and paid separately)
M & L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including providing one coat of aluminium paint over coat of red oxide zinc crome primer and providing 03 Nos of band/ strap with paint black/ yellow colour, 300mm apart from plinth block and numbering of pole and one coat of black bitumenous paint over a coat of red oxide zinc chrome primer to embedded portion of pole complete all as specified and directed. (Note : Excavation and Earth work shall be measured and paid separately)
M & L for Cross arms bracing supports clamps and back plates fabricated from structural steel sections including nut bolt washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and including one primer coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminium paint and including dismantling cross-arms of M.S. channel or angle sections etc. complete all as specified and directed.
M & L for pin type porcelain vitreous white/brown insulator including one galvanised mild steel spindle two galvanised iron nut 100 mm height 65 mm dia suitable for 1100 volts grade and including taking down insulators of any type from LT poles of any size and type complete all as specified and directed.
M & L for shackle type porcelain, insulator vitreous, white, brown or green, including galvanised mild steel, straps, washers, insulator bolts, washers and nuts, 75 mm height and 90 mm dia, size of strap 31 mm x 3 mm and dia of bolt 12 mm suitable for 1100 volts and including taking down insulators of any type from LT poles of any size and type complete all as specified and directed.
M & L for Stay assembly complete with all accessories as shown in electrical plate No 1 of MES Schedule Part I dia of stay rod 16mm with and including 7 / 3.15 mm galvanised stay strand complete including taking down/dismantling existing one all as specified and directed. (Note : Loop insulator, excavation & earthwork and cement concrete measured and paid separately under relevant items of this Schedule.)
Materials and labour for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT, 25 x 20 cm size including dismantling of old one complete all as specified and directed.
M & L for galvanised steel earth wire 4 mm dia as continuous earth wire, guards and cradles (hexagonal/rectangular) and including GI binding wire 1.6mm dia and including dismantling of old unserviceael ones, suitable for LT/HT over head line complete all as specified and directed.
Supply, laying, testing and commisoning of cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 400 Sqmm 3.5 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out existing unserviceable cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
All as per Serial item No. 9 above but for 150 Sqmm 3.5 Core cable complete ditto
All as per Serial item No. 9 above but for 95 Sqmm 3.5 Core cable complete ditto
All as per Serial item No. 9 above but for 25 Sqmm 3.5 Core cable complete ditto
All as per Serial item No. 9 above but for 16 Sqmm 4.0 Core cable complete ditto
All as per Serial item No. 9 above but for 10 Sqmm 2.0 Core cable complete ditto
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches not exc. 1.5 metre wide and exc. 1.5 metre & not exc. 3 metre depth (beyond the first 1.5 metre) for foundation of poles etc and getting out in soft/loose soil complete all as specified and directed.
M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed. (Note: Thickness after punning down shall be measured for payment)
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm for cable protection cover laid flat and dry in trenches over the cable, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
S & F in repair for 100 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in cable protection complete to walls and ceilings or laid in floors complete all as specified and directed.
S & F in repair for 80 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in cable protection complete to walls and ceilings or laid in floors complete all as specified and directed.
S & F in repair for 50 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in cable protection complete to walls and ceilings or laid in floors complete all as specified and directed.
S & F in repair for 40 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in cable protection complete to walls and ceilings or laid in floors complete all as specified and directed.
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for plain cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed.
M & L for Preparation of old painted surface above the planting depth/PCC coping of steel tubular LT pole upto 9.00 metre long including MS clamps, cable protection pipe, bracket fitted with street light fittings etc by scraping with steel wire brush and applying one coat of aluminium paint to external surface of poles, MS cross arms, MS clamp, cable protection pipe etc to give even shade including 5 Nos strips painting of 300mm high each around the pole with two different colour (black/yellow) of synthetic enamel paint and numbering of poles complete all as specified and as directed by the Engr-in-Charge.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 1100 Volts for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of worker, black or blue colour Class A of sizes 2m x 1m and including taking down old unserviceable ones complete all as specified and directed
Re-straining and tightening of existing serviceable ACSR conductor of any size without taking down including all arangement and including binding wire 2 mm dia and colour sleeve Jumpers complete all as specified and directed. Notes:- (i) Safety equipments, ladder, T&P etc charges deemed to be included in quoted rates (ii) Before commencement of work, contractor has to obtain necessary electric shut down from concerned MES JE(E/M)/Engr-in-Charge. In case of any casulity occurs, contractor will be fully responsible for the same.
Trimming of tree branches around the overhead conductor, poles & stays (not less than 3 metre) to clear the approach of overhead lines including removing of nest, wild grass creepers, unwanted vegetation, etc from pole/stay including cleaning of creepers climbed on poles and angles, channels and disposed off from site beyond 50m and upto a total distance of 250m complete all as specified and directed by the Engr-in-Charge.
S & F in repair MCCB 63 Amps 4 pole, 16 KA, 415 Volts, 50 Hz thermal magnetic including outgoing and incoming cable connection and fixing to existing panel board, complete all as specified and as directed.
S & F in repair MCCB 200 Amps 4 pole, 25 KA, 415 Volts, 50 Hz thermal magnetic release including outgoing and incoming cable connection and fixing to existing panel board, complete all as specified and as directed.
S & F in repair MCCB 250 Amps 4 pole, 25 KA, 415 Volts, 50 Hz thermal magnetic release including outgoing and incoming cable connection and fixing to existing panel board, complete all as specified and as directed.
S & F in repairs Air Circuit Breaker (ACB, 415 Volt, 50 kA, 4 Pole, 630 Amps Capacity, thermal magnetic release (drawout type) complete all as specified and as directed. (Make: L & T Cat Part No. SL95351 or equivelant of make as per List of Manufacturer's)
S & F in repair PVC/fibre separator for LT over head line 1100 volts conductor 3/4 wire system for horizontal two Nos, in span including taking down old separator complete all as specified and as directed .
S & F in repair on load change over switch (side handle operated) in sheet metal enclosure, 63 Amps rating, 4 pole, 415 Volts, 50 Hz and connecting up complete all as specified and directed.
S & F in repair on load change over switch (side handle operated) in sheet metal enclosure, 100 Amps rating, 4 pole, 415 Volts, 50 Hz and connecting up complete all as specified and directed.
S & F in repair on load change over switch (side handle operated) in sheet metal enclosure, 125 Amps rating, 4 pole, 415 Volts, 50 Hz and connecting up complete all as specified and directed.
S & F in repair on load change over switch (side handle operated) in sheet metal enclosure, 250 Amps rating, 4 pole, 415 Volts, 50 Hz and connecting up complete all as specified and directed.
S & F in repair LED ammeter, 0-50 Amps of dial size 96x96mm flush mounting with accuracy class 1.0, single phase, complete all as specified and directed.
S & F in repair LED voltmeter, 0-500 Volts of dial size 96x96mm flush mounting with accuracy class 1.0, single phase, complete all as specified and directed.
Grass cutting around the LT panel and poles and removing the grass not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed., complete all as specified and directed.
M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
M/S A K ENTERPRISE (BID ID -3298118)
ABOTANI ENTERPRISE (BID ID -3299605)
FREEZCON (BID ID -3299657)
M/S. UDDUG CONSTRUCTION (BID ID -3299510)
M/S R D CONSTRUCTION (BID ID -3298122)
R D Enterprises (BID ID -3299815)
Shree Trilok Electric Corporation (BID ID -3298351)
M/S Abhi Traders (BID ID -3300174)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .