| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.1 LAccepted-AOC GSTIN: 06AAMFP6274F1ZZ12 MANAULI HOUSE AMBALA CITY 134003 HRY | AMBALA CITY | AMBALA | HARYANA | 134003 | ₹49.1 L Quoted ₹49.8 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹52.9 LRejected-Finance GSTIN: 06AELPG3910N1ZE186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | ₹52.9 L | L2 | Rejected-Finance 2nd Lowest |
| Sl No | Description | Qty | Unit | PARAMOUNT INDUSTRIES L1 | M/S Sonu Traders L2 |
|---|---|---|---|---|---|
| 1.00 | Dismantling of old u/s MFM of any make and type and replacement with DC Power MFM for DC power supply Input Voltage Max continuous input voltage 125% of nominal value Technical Specs VA Burden Nominal input voltage burden < 0.4 W approx. Nominal input current burden < 0.1 W approx. Auxiliary Supply burden < 6 VA approx Accuracy Reference Conditions 23°C +/- 2°C Voltage ±0.5% of Nominal value (±20 to ±120%) Current ±0.5% of Nominal value (±5 to ±120%) Power ±0.5% of Nominal value (±5 to ±120%) Energy Class 0.5 Temperature Drift 0.05%/°C Input Current Display Type 1 line 8-digit LED Display Display Height 9 mm Overload Indication -oL- (Above 126% of nominal value) Display Range Voltage 0 to ±9999 Current 0 to ±9999 Power 0 to ±9999 Energy (Import & Export) 0 to 99999999 Shunt Setting Range 50 ~ 150 mV No of Channels 1 Current Sensor External Shunt Full Scale Setting Range 1 A to 20 kA Max continuous input current 125% of nominal value 61 ~ 200 VDC Nominal Input Voltage Range 10 ~ 60 VDC 201 ~ 1000 VDC Auxiliary Supply Operating Measuring Range Voltage ±5 to ±125% of nominal value Current ±0.2 to ±125% of nominal value Nominal Value 230 V AC-DC, 50/60 Hz for Higher Aux Higher Aux 60 V – 300 V AC-DC, 45 to 65 Hz range Uncertainty ±2 minutes / month (23°C +/- 2°C) Real Time Clock (RTC) Lower Aux 20 V – 60 V AC-DC 24 V AC-DC for Lower Aux 3 92mm+0.8 Panel Cutout 92mm+0.8 Dimensions Details96mm Overload Withstand 2 x rated value for 1 second, repeated 10 times at 10 second intervals Overload Withstand 20x rated value for 1 second, repeated 5 times at 5 min intervals NOTE: Variation due to influence Quantity is 100% of class index built with Data Logging User Selectable parameters (1 to 30) can be logged at regular intervals (1 to 60 min) with Date & Time stamp in internal memory and can be | 12 | Each | 36,000 ₹4.3 L | 38,000 ₹4.6 L |
| 1.01accessed via Modbus l Max Records can vary from 8532 to 91010 depending upon number of selected parameters Load Analysis Logging of Energy consumed and Peak Demand (Power & Current) in a day and in a month for tracking of load behaviour l Daily Data is available for last 1 year and Monthly Data is available for last 14 years Direct Remote Access (optional) l Remote configuration of the Instrument and access of measured parameters via MODBUS l Programmable baud rates up to 57.6kbps 1 - line 8 digit Ultra-bright LED Display l 1 - line LED display provides easily readable data on meter front with a display range of 99999999 Reverse Locking l Energy and Ampere Hour accumulation can be blocked for Reverse Power and Current resp l Reverse condition can be set as Import or Export Onsite Configuration can be done via Front Keys, USB Serial Interface or RS485 (MODBUS) Relay Functions l Limit Switch - For protection against over-shoot or undershoot of any selected parameter l Pulse Output - To drive an external counter for energy measurement l Timer - Cyclic ON-OFF operation of relay for user-dened cycles with programmable ON-OFF Delays l Remote Operation - Relays can be activated remotely via Modbus l Reverse Locking Alarm l RTC Relay - Relay can be activated & deactivated with ON & OFF Time on any or all Days of Week Enclosure Protection for dust and water l Conforms to IP 54 (front face) as per IEC60529 Compliance to International Safety standards l Compliance to International Safety standard IEC 61010 - 1 - 2010 EMC Compatibility l Compliance to International standard IEC 61326 – 2012. Note :- Contractor has to submit post audit report of work from approved auditor, without that completion will not be issued. | |||||
| 2.00 | Dismantling of old U/S protection , alarm & replacement with new , installation , testing , commissining of DC Failure protection system unit suitable for 33kV Control Panel and exisiting Breaker with Indication by High bright LED Built in test & accept push buttons Built in audible alarm Suitable for wide range of DC supply Three No’s. normally open contacts also given for externel application like remote window or alarm High barrier with Shrouded connectors for easy & safety terminations suitable for 11 KV/ 66 KV switchgear with built in TECHNICAL SPECIFICATION: Input DC Supply : 20 to 250V DC. Input AC Supply : 230V AC ± 20%. Audible alarm output : 90dB at 1 Meter – Intermittent sound. Response time : Less than 100 msec. (Indication & alarm When DC fails). Output relay contacts : 1 NO Contacts Contact rating : 5A at 230VAC/30VDC Mounting Type : Flush mounting. Make ISO 9001:2015 Certified or approved by GE or accepting Officer . ONLY Original OEM is entitled for work . Contractor has to ensure it.Necessary test certificates & Latest Purchase Vouchers to be scrutnised / approved by Engg-in-Charge & GE first before execution at site . Any Defect occuring during this period due to bad workmanship of material, manufacturing defect shall be rectified or replaced free of cost. The contractor shall furnish written gaurantee on letter head for above mentioned to the GE immidiately after completion of work. | 12 | Each | 50,400 ₹6.0 L | 53,000 ₹6.4 L |
| 3.00 | Dismentaling of old damaged contactor and replacement with new 4 pole contactor 110 volts DC 16 Amp with Conformance to IEC 60947-4-1, CE Marking• Current Rating: 16A • Available in 4NO and 2NO+2NC Power Pole combination Wide Band Coil for all ratings in 220 & 415 VA MAKE AS PER EXISITING | 12 | Each | 29,700 ₹3.6 L | 31,500 ₹3.8 L |
| 4.00 | Dismantling of old damaged metering along with selector switch assembly and replacement with new Supply, installation, commissioning of programmers equipped with real time power analyser / recorder complete with capacity to undertake multiple MODBUS DATA multifunctional meters with following specifications as 4G/ 3G/ 2G / Ethernet based IIoT Controller with modem input supply 230VAC, 0.5A max with multi-protocol capability Processor: Cortex-A53 64-bit SoC @ 1.2GHz RAM: 1GB Flash memory: 12GB Operating temperature: -20 to +70°C Ports: Must have an Ethernet, RS485 and USB (user defined) Remote terminal unit (RTU): 4G/ 3G/ 2G SIM cards for 5 years subscription. Data services must be from at least two reliable service providers and system should support automatic switching to 2nd service provider in case of low network without any intervention. System should support changing of service providers without changing SIM cards (future ready). Future ready RTU must have Modbus, IEC60870, IEC61850, MBUS, DLMS (all mandatory and selectable). Any other future open-source protocol (that uses RS485 or TCP port) must be provided free of cost for the period of at least 5 years (OEM declaration mandatory). Capable of capturing multi-function meter along with Run Hours as well as other fields from any compatible substation/ metering equipment Communication interface & Communication protocols Modbus, IEC60870, IEC61850, MBUS, DLMS (all mandatory and selectable on all adequate ports). Any open-source protocol (for RS485 and ethernet port) will be supported for five years without any cost (OEM declaration mandatory) Enclosure with Energy meter connection Must support different make models of energy meters in same daisy | 3 | Each | 4,99,500 ₹15.0 L | 5,29,500 ₹15.9 L |
| 4.01chain Time payload 1 min, 5 min, 15 min configurable remotely with real-time anomaly detection Technical details Real-time KW, KVA, KVAR, phase-wise, consumption KWh, KWh, KVarh, KVAh, PF, phase-wise PF, Hz, I, Ig, In, VLL (phase wise), VLN (phase wise), Vn, Vg, harmonics, voltage and current unbalance User Interface The cloud-based facility management system should enable controlling substations and facilities. The system should support adding more parameters in future with minimal changes. AF should have a mechanism to proactively know when some equipment is not giving data / has errors without coming to site. User interface should be remotely accessible on internet, with secure login credentials. User interface should work on secure https. Communication between data gathering, and data storage should be over a secure encrypted channel. IIOT controller must have inbuild local control capability to operate in case of network unavailability. However, control logics must be configurable remotely. The user-interface should have minimum of following tabs (all dashboards, reports must be self-configurable without any scripting or OEM intervention): Dashboard - To evaluate captured parameters at a glance with current, hourly, daily, weekly, monthly, & yearly. End-user should be able to create Dashboards on their own, without AF involvement. End user should be able to define number of rows / columns in dashboard, merge cells of dashboard to make some areas small / large, configure row heights to provide flexibility in how data is displayed (ex. multiple numerical KPIs in a smaller row, and graphs in a larger row to utilize displayed area of dashboard optimally) | |||||
| 4.02Dashboards should allow display of both graphical data, as well as numerical KPIs (max, min, aggregated Sum, averaged values over day, week, month) For Graphs & KPIs displayed on Dashboard, user should be able to choose different time durations directly from Graph/KPI’s options to update the Graph/KPI dynamically End user should be able to create multiple dashboards User should be able to select and zoom-in / zoom-out on specific area within graphs User should be able to save graphs as an image in various formats (.png, .jpeg etc) For multiple Dashboards, user should be able to define display order of Dashboard in navigation (for ex: which is more important and should come first) AF should be able to turn off/on options in graphs to maximize utilization of available display area for each graph (ex. axis, legends, menu options, title etc.) Graphs should support at least following visualizations: line graph, pie graph, donut graph, area graph, bar graph, heatmap graphs User should be able to plot data from different sites on same graph Layout - Diagram of the system with SLD viewing options. Electrical SLD with all IEC symbols is must Chart - graphs based on data from multiple sources such as inverter and local weather databases. Histograms/Pie charts/Bar graphs/line graphs/ donut graph, area graph, heatmap graph shall be available. System should support Time vs Time comparison of captured parameters by showing data of interested days/months adjacent to each other (example: 9th day of this month, and last month displayed adjacent to each other) System should support Spend Analysis (money equivalent of energy, and not just units of energy) System should support creating user-defined KPIs (max, min, aggregated Sum, averaged values over day, week, month) system should support creating user-defined benchmarks, and displaying | |||||
| 4.03data in charts / dashboard comparing against these benchmarks System should support saving frequently used analytics charts for later users. All saved charts should be available to choose with a single-click. System should support showing analytics data in graphical and tabular form. Facility to export data over a custom time interval to Excel shall be available. Reports should be user-defined and not fixed (hardcoded into the system). System should support sending daily, weekly and monthly reports. Daily reports should be sent next day morning over email incorporating all data from previous day. There should be a mechanism to turn reporting sending of scheduled reports ON/OFF There should be a mechanism to send a pre-created report on-demand (and not just as scheduled daily / weekly / monthly report) Settings - To view the metadata related to the system, such as the site name and installation date, details of equipment at site etc. Alarms and event logs – Alarm should Issue a system update that the system has detected. Passwords should be stored in encrypted format. Website should be accessible on all platforms and be compatible with popular browsers such as IE, Chrome, Firefox, Safari etc. Online Administration: All administration is handled online via a current web browser Audit Trail: Administrators can access logs in the backend on need-basis where they can view changes that have been made to the database for critical information. Data Backup | |||||
| 4.04should support PITR (Point-in-time-recovery). Scheduler for auto archival and backup of application and database to a different machine which should be capable of coming online by simply firing a script button in event of downtime of primary server. The database should use encryption at rest to persist the data in database. Secure password protected login for administrative actions in the system. All updates to data gathering hardware should be through OTA (over the air). No static IPs shall be made available at sites. The complete equipment must be programmed with protection CT inside the existing Low Tension switchgear /breaker / Switching Contactors along with multifunction microprocessor digital programmer having Main measurements and functions include: Voltage: phase, line and system values Current: phase values (neutral current calculated) Power: apparent, active and reactive phase and total values Power Factor per phase and total Frequency of measured voltage value HIGH LOW AVERAGE - - value functions for all measurements Maximum demand of power and current values Voltage and current asymmetry Total harmonic distortion ( ): voltage and current THD Energy meters for active, reactive, apparent partial and total values, per phase and system values Hour counter for programmable total and partial hours Phase active power unbalance must saturate sufficiently high to allow a relatively accurate measurement of the fault current by the protection whose operating threshold can be very high. with built in high Accuracy Limit Factor (ALF) ratio between the nominal overcurrent and the rated current. so that existing switchgear relay must be able to withstand high overcurrent’s also featured with Real accuracy factor ratio between the overcurrent , nominal error and | |||||
| 4.05the rated current .with following specifications insulation level voltage .433 KV ratio 100/5A - to 500/5A Core 3 class PS, KPV >= 150 Volts Imag at vk/2<= 30 ma , RCT at 75C<= 2 Ohms short time rating 15 KA for 1 second approved by GE minimum ISO 9001:2015 Certified. Note :- (i) The Entire work at site is to be executed only by OEM approved by GE. Original OEM is entitled for work . Contractor has to ensure it.Necessary test certificates to be approved by Engg-in-Charge first before execution at site. (ii) Contractor has to submit post audit report of work from approved auditor, without that completion will not be issued. | |||||
Updated dates
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
4 Feb 2026, 6:00 pmClosed
HQ CWE MEERUT
29J The Mall Road Meerut Cantt Uttar Pradesh 250001
REPAIR/MODIFICATION OF ELECTRIC ELECTRIFICATION SYSTEM NETWORK FOR IMPROVEMENT INCL ALLIED SYSTEM AT GE (U) MEERUT CANTT
2025_MES_735043_3
94278/MRT/2025-26/E8
Open Tender
Civil Works
120 days
MEERUT CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (U) MEERUT
₹96,000
Yes
17 Apr 2026
8 Jan 2026
9 Feb 2026
8 Jan 2026
4 Feb 2026
16 Jan 2026
Dismantling of old U/S protection , alarm & replacement with new , installation , testing , commissining of DC Failure protection system unit suitable for 33kV Control Panel and exisiting Breaker with Indication by High bright LED Built in test & accept push buttons Built in audible alarm Suitable for wide range of DC supply Three No’s. normally open contacts also given for externel application like remote window or alarm High barrier with Shrouded connectors for easy & safety terminations suitable for 11 KV/ 66 KV switchgear with built in TECHNICAL SPECIFICATION: Input DC Supply : 20 to 250V DC. Input AC Supply : 230V AC ± 20%. Audible alarm output : 90dB at 1 Meter – Intermittent sound. Response time : Less than 100 msec. (Indication & alarm When DC fails). Output relay contacts : 1 NO Contacts Contact rating : 5A at 230VAC/30VDC Mounting Type : Flush mounting. Make ISO 9001:2015 Certified or approved by GE or accepting Officer . ONLY Original OEM is entitled for work . Contractor has to ensure it.Necessary test certificates & Latest Purchase Vouchers to be scrutnised / approved by Engg-in-Charge & GE first before execution at site . Any Defect occuring during this period due to bad workmanship of material, manufacturing defect shall be rectified or replaced free of cost. The contractor shall furnish written gaurantee on letter head for above mentioned to the GE immidiately after completion of work.
Dismentaling of old damaged contactor and replacement with new 4 pole contactor 110 volts DC 16 Amp with Conformance to IEC 60947-4-1, CE Marking• Current Rating: 16A • Available in 4NO and 2NO+2NC Power Pole combination Wide Band Coil for all ratings in 220 & 415 VA MAKE AS PER EXISITING
chain Time payload 1 min, 5 min, 15 min configurable remotely with real-time anomaly detection Technical details Real-time KW, KVA, KVAR, phase-wise, consumption KWh, KWh, KVarh, KVAh, PF, phase-wise PF, Hz, I, Ig, In, VLL (phase wise), VLN (phase wise), Vn, Vg, harmonics, voltage and current unbalance User Interface The cloud-based facility management system should enable controlling substations and facilities. The system should support adding more parameters in future with minimal changes. AF should have a mechanism to proactively know when some equipment is not giving data / has errors without coming to site. User interface should be remotely accessible on internet, with secure login credentials. User interface should work on secure https. Communication between data gathering, and data storage should be over a secure encrypted channel. IIOT controller must have inbuild local control capability to operate in case of network unavailability. However, control logics must be configurable remotely. The user-interface should have minimum of following tabs (all dashboards, reports must be self-configurable without any scripting or OEM intervention): Dashboard - To evaluate captured parameters at a glance with current, hourly, daily, weekly, monthly, & yearly. End-user should be able to create Dashboards on their own, without AF involvement. End user should be able to define number of rows / columns in dashboard, merge cells of dashboard to make some areas small / large, configure row heights to provide flexibility in how data is displayed (ex. multiple numerical KPIs in a smaller row, and graphs in a larger row to utilize displayed area of dashboard optimally)
data in charts / dashboard comparing against these benchmarks System should support saving frequently used analytics charts for later users. All saved charts should be available to choose with a single-click. System should support showing analytics data in graphical and tabular form. Facility to export data over a custom time interval to Excel shall be available. Reports should be user-defined and not fixed (hardcoded into the system). System should support sending daily, weekly and monthly reports. Daily reports should be sent next day morning over email incorporating all data from previous day. There should be a mechanism to turn reporting sending of scheduled reports ON/OFF There should be a mechanism to send a pre-created report on-demand (and not just as scheduled daily / weekly / monthly report) Settings - To view the metadata related to the system, such as the site name and installation date, details of equipment at site etc. Alarms and event logs – Alarm should Issue a system update that the system has detected. Passwords should be stored in encrypted format. Website should be accessible on all platforms and be compatible with popular browsers such as IE, Chrome, Firefox, Safari etc. Online Administration: All administration is handled online via a current web browser Audit Trail: Administrators can access logs in the backend on need-basis where they can view changes that have been made to the database for critical information. Data Backup
should support PITR (Point-in-time-recovery). Scheduler for auto archival and backup of application and database to a different machine which should be capable of coming online by simply firing a script button in event of downtime of primary server. The database should use encryption at rest to persist the data in database. Secure password protected login for administrative actions in the system. All updates to data gathering hardware should be through OTA (over the air). No static IPs shall be made available at sites. The complete equipment must be programmed with protection CT inside the existing Low Tension switchgear /breaker / Switching Contactors along with multifunction microprocessor digital programmer having Main measurements and functions include: Voltage: phase, line and system values Current: phase values (neutral current calculated) Power: apparent, active and reactive phase and total values Power Factor per phase and total Frequency of measured voltage value HIGH LOW AVERAGE - - value functions for all measurements Maximum demand of power and current values Voltage and current asymmetry Total harmonic distortion ( ): voltage and current THD Energy meters for active, reactive, apparent partial and total values, per phase and system values Hour counter for programmable total and partial hours Phase active power unbalance must saturate sufficiently high to allow a relatively accurate measurement of the fault current by the protection whose operating threshold can be very high. with built in high Accuracy Limit Factor (ALF) ratio between the nominal overcurrent and the rated current. so that existing switchgear relay must be able to withstand high overcurrent’s also featured with Real accuracy factor ratio between the overcurrent , nominal error and
the rated current .with following specifications insulation level voltage .433 KV ratio 100/5A - to 500/5A Core 3 class PS, KPV >= 150 Volts Imag at vk/2<= 30 ma , RCT at 75C<= 2 Ohms short time rating 15 KA for 1 second approved by GE minimum ISO 9001:2015 Certified. Note :- (i) The Entire work at site is to be executed only by OEM approved by GE. Original OEM is entitled for work . Contractor has to ensure it.Necessary test certificates to be approved by Engg-in-Charge first before execution at site. (ii) Contractor has to submit post audit report of work from approved auditor, without that completion will not be issued.
functions for all measurements Maximum demand of power and current values Voltage and current asymmetry Total harmonic distortion ( ): voltage and current THD Energy meters for active, reactive, apparent partial and total values, per phase and system values Hour counter for programmable total and partial hours Phase active power unbalance one incoming four outgoing suitable to collect all necessary parameters, Send commands, such as counters reset or enabling and disabling of mustimeter outputs with Harmonic filter reactors to protect the system by pushing harmonics in PFC systems approved by GE minimum ISO 9001:2015 Certified. Note :- (i) The Entire work at site is to be executed only by OEM approved by GE. Original OEM is entitled for work . Contractor has to ensure it.Necessary test certificates to be approved by Engg-in-Charge first before execution at site. (ii) Contractor has to submit post audit report of work from approved auditor, without that completion will not be issued.
Dismantling of old damaged u/s lights & replacement with new S/I/T/C of Degree of protection IP65 LED Integral LEDs 12 V, 24 V, 30 V, 48 V, 60...63.5 V, 110 V, 220...230 V AC/DC Colour White, Green, Red, Amber, Blue, Yellow of Ø 22/0.866 in. plastic control and signalling units Make as directed by Engg-in -charge
Dismantling of old damaged 2 CORE 1.5 sq mm copper wire and replacement with new from CR room to Yard control panel in Roorkee road , Shivaji line & Bhagat lined
Maintenance Free Earthling with retains the Moisture for very long time, ensuring quick dissipation of Faults, Short Circuits and Lightning Current. With Corrosion Resistant, Eco Friendly and Highly Conductive. To be installed indoor or outdoor and in almost all soil conditions. with The conductive compound in and around the Electrode creates a conductive zone which provides a greater surface area for Peak Current dissipation with minimum Long and Reliable average life of 05 year systematic pipe earthling system designed in accordance to IS: 3043 (1987) consist of copper bonded electrode 76mm x 3 metre along with 50 kg pro earth high enhancing compound along with necessary GI strip up to 10 meter from test point to concerned LT Panel /Tfr as directed by engineer in charge High Tensile Strength, Low Carbon steel core having terminal with four holes for connection with electrolytic coating of copper deposits having metallurgical bond between the core and the copper. Featuring never cracks or bended. Boring rates and complete tasking rates are included The standard copper thickness is 0.25 mm. The copper bonded grouup electrodes have a high resistance to corrosion and provides a low resistance path to ground. With earthling material DARK GREY SWELLING VOLUME 28ML/1000ML DISPERSION RATE HIGH pH 8-9 MOISTURE CONTENT 10-11% 50 kg in each earth
Homogenous Mixture of naturally occurring highly conductive element compounds that enhances the effectiveness of the earthling to a great extent especially in the area of poor conductivity to be placed around the earth electrode in the pit to improve the conductivity of earth electrode and ground conduct area. Each earth must have hygroscopic in nature thereby retaining moisture around earth electrode during dry seasons. It is nontoxic, non-explosive, non-reactive, noncorrosive, and thermally stable and swells considerably. Earth Pit Chambers are made of Heavy Duty Polyethylene/Polyplastic material.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_837265.pdf
techsummary_837265.pdf
finance_837265.pdf
BOQ Comparative Chart
xlsx
finsummary_837265.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.28 MB
TD1.pdf
Tender Documents • 0.39 MB
TD2.pdf
Tender Documents • 0.21 MB
TD3.pdf
Tender Documents • 0.24 MB
TD4.pdf
Tender Documents • 0.57 MB
BOQ_837265.xls
BOQ • 3.44 MB
Download all tender documents and submit your bid