| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.5 LAccepted-AOC | 1 | Accepted-AOC work order issued | |
| 2 | 2₹6.5 L+₹1,652 (0.25%)Rejected-Finance | 2 | Rejected-Finance - |
Tender Value
₹7.8 L
EMD Value
₹7,750
Closing Date
10 Sept 2024, 3:00 pmClosed
Executive Officer
Thalanayar Town Panchayat Office
Construction of Busshelter at Infront of Dr.MGR Fisheries College and Research Institute in Thalanayar town panchayat
2024_DTP_480395_1
442/2024/A1
Open Tender
Civil Works - Buildings
Works
90 days
Thalanayar Town Panchayat
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹7,750
17 Oct 2024
3 Sept 2024
10 Sept 2024
3 Sept 2024
10 Sept 2024
3 Sept 2024
3 Sept 2024 - 10 Sept 2024
Amount
Boring, providing and installing Bored cast-in-situ reinforced cement Concrete pile of specified diametre and length below the pile cap in cement concrete 1 :1.5:3 ( 1 cement, 1 .5 Coarse sand,& 3 graded stone aggregate of 20 mm nominal size) to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including Bentonite solution machinery charges labour chargres etc.,all complete. (Length of pile for payment shall be measured from bottom pile to the bottom of pile cap).450 mm dia Piles
Earth work excavation in all classes of soils such as hard stiff clay, stiff black cotton, hard red earth, shales, murram, ordinary earth, earth mix with 50% fair sized boulders etc., with initial lead and lifts including laying, spreading, leveling, sectioning breaking clods etc., including all incidental charges etc., complete as per standard specification . for Foundations SS 20B
Cement concrete of mix 1:4:8 (One cement Four M-Sand Eight aggregates) using 40mm gauge hard broken including cost conveyance of all materials to site including labour charges, transporting and placing in position including shoring, strutting forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification.
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers -
Supplying & Erecting centering for sides & soffiots including necessary supports & strutting upto 3.29m height for plane surfaces in all floors with all cross bracings using mild steel sheets of size 90 x 60cm & 10 gauge stiffened, welded with steel angle of size 25 x 25 x 3mm for boarding laid over silver oak joists(Country wood) of size 10 x 6.5cm spaced @ about 90cm c/c and supported by casurina props of 10 - 13cm dia. spaced @ 75cm c/c etc., complete complying with standard specifications and as directed by the departmental officers. Rate for 10m2.for the following items.(RCC floor slab, roof slab, Rectangular/ square, Tee/ Ell beams, Lintels, staircase waist slabs, Landing slabs, Landing beam, Portico beam etc., ).
Without Strutting
Square Column
Plain Surface
Supplying and Fabrication of Steel and placing in position MS / Ribbed tor steel Grills for RCC works as per design given including cost of steel and GI binding wire in Floors etc,. Complete complying with standard specification in force and as directed by department officials.-
Brick work in Cement Mortar in 1:5 ( One cement and Five M-Sand ) using best quality of Country bricks of size 8¾x 4 ¼ x 2 ¾ including all cost of materials and labour charges including Curing charges etc., complete as per Standard Specificationand as directed by department officials.
Plastering walls with cement mortar 1:5 (One cement five P-Sand) 12mm thick in all floors and all exposed surfaces including cost and conveyance of materials to site and all labour charges,Curing etc completeand as directed by department officials..
Special Plastering with cement mortar 1:3 (One cement three P-Sand) 10mm thick including cost and conveyance of materials to site and including all labour charges etc complete.
Weathering course in Brick jelly and lime concrete using broken brick jelly of size 20 mm uniform gauge in pure slacked lime ( no sand to be used ) the proportion of brick jelly to lime being 32:12.5 by volume laid over the RCC roof slab in a single layer of required design , slope and finished thickness by beating the concrete with wooden and beaters of approved pattern keeping the surface constantly wet by springing lime Jaggery water etc complete as per standard specification.
Finishing the top of Roof with one course of machine pressed tiles of size ( 23x23x2 cm ) approved quality in C.M. 1:3 - 12 mm thick mixed with water proofing compound confirming to IS @ 2 % by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc complete as per standard specification.
Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
Dadoing walls with the following types tiles of suitable size of approved quality and colour set in cement mortar 1:2 (one cement ,two P -sand); 10mm and pointing with colour cement neatly etc., complete in all floors.
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris, putty, wherever required etc., complete complying with standard specification
Supplying and fixing of M.S. steel grill using M.S. angle frames including cost of M.S. angles (50mm x 50 mm x 6mm) T , L angles, flats and square rods in proper position including labour charges for cutting, welding, and including labour charges for priming cost of red oxide painting and erection in a proper position etc. complete as per standard specification and Grill design , Thickness of square rod are approved by the departmental engineers.
Supply and Fixing of Stainless Steel Hand Rails proper position including labour charges for cutting, welding, and including labour charges for priming cost of red oxide painting and erection in a proper position etc. complete as per standard specification and Grill design , Thickness of square rod are approved by the departmental engineers.
Painting new iron works with two coats of approved quality and color of synthetic enamel paint over the existing red oxide primer in all floor etc., complete as per standard specification.
Wiring with 2 x 1.5 sqmm (22/0.3) PVC insulated SC. unsheathed Cu.Conductor of 1100 V grade in suitable PVC rigid Pipe on wall and ceiling with PVC accessories and with TW switch box and 5A F.T. switch with painting of suitable Colour for Consealed PVC light point / fan point (For electronic regulator. SD 24
Wiring with 2x4 sqmm(56/0.3) PVC insulated SC unsheathed Cu.Conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories, in flush with wall, with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet for 15 A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire , and making good of the concealed portion, with suitable colour for concealed power plug point SD 40
Supply and fixing of single box type 4'40 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting. SD 89
Supply and fixng of TNEB Moter Board suitable for 3 Phases 100A service connection made up of suitable angle iron frame work of size 2 feet x 1 1/2 feet using angle iron of size 1 1/2" x 1 1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1 1/2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos 100A fuse units (500V) 1 No. Neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuse units by 7/16 PVC insulated copper wire with earth connection complete SD 125
Service Pipe standard with an earth electrode of 2 Mtr. Class 'B' GI pipe of dia not less than 32mm complete with necessary masonry work
Supply and run of 2 of 1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour SD 43
Supply and fixing of 32 Amps DP Switch of 500V with metal clad with fuse and neutral (Side Handle) on suitable TW Board with PWD Earthingincluding cost and conveyance of all materials to site and all labour charges etc complete asper std. specifications. (SD 143)
Supply and run of 2 of 6 sq.mm (84/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V on 7/20 GI bearer wire for service connection mains of approved quality including cost and conveyance of all materials and labour charges and other incidental charges to site etc., complete. as per standard specification (SD 66)
V PANNEERSELVAM (BID ID -1133488)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .