Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC 101 1ST FLOOR JASOL RESIDENCY 14TH CROSS KANAKANAGAR R T NAGAR POST BANGALORE 560032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.8 L+₹1.5 L (5.43%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹28.9 L+₹1.6 L (5.97%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹29.2 L+₹1.9 L (7.04%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹29.2 L+₹1.9 L (7.06%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
Tender Value
Refer Docs
EMD Value
₹77,000
Closing Date
19 Jun 2021, 6:00 pmClosed
Commander Works Engineers AF South, Bangalore
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
SPECIAL REPAIRS TO INTERNAL WIRING AND FITTINGS AND FIXTURES OF BUILDING NO P-318 AT E AND ITI, AFS JALAHALLI.
2021_MES_437850_1
85200/E8
Open Tender
Civil Works
Item Rate
180 days
GE(M) AF JALAHALLI, BANGALORE
As pet NIT
7 documents required · 7 mandatory
₹500
GE(M) AF JALAHALLI, BANGALORE
₹77,000
Yes
12 Jul 2021
22 Apr 2021
21 Jun 2021
23 Apr 2021
19 Jun 2021
7 Jun 2021
23 Apr 2021 - 7 May 2021
Amount
Taking down carefully copper/aluminum point wiring (light, fan,Power) complete fittings such as switches , ceiling roses pendents , regulators sockets light fittings etc removing to store for keeping in safe costody or for taking credit and making good disturbed surface of wall, floors , roof etc all as specified and directed.
M&L for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20mm on surface including provn of pressed steel terminal box of suitable size with 3mm thick plastic laminated sheet cover for mounting switch, socket and regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm for One light point controlled by one switch one way 5 Amps all as specified and directed.
All as per item No 2 above but One light point controlled by two way switch 5 Amps
All as per item No 2 above but One celling fan point controlled by one switch one way 5 Amps
All as per item No 2 above but One exhaust fan point controlled by one switch one way 5 Amps
All as per item No 2 above but One socket out let 5 Amps 5 pin on same board
All as per item No 2 above but One socket out let 5 Amps 5 pin on independent board
All as per item No 2 above but with cable size 2.5 Sq mm for one 3/5 pin 15 Amps socket outlet on independent board and multistrand insulated copper earth continuity conductor of size 2.5 sqmm all as specified and directed. Note for item No. 2 to 8 :- Cutting chases for routing conduit and making good as per the existing where ever necessary shall be measured and paid seperately.
S & F Switch piano flush type single pole one way 5 Amps complete all as specified and directed.
S & F switch piano flush type single pole two way 5 Amps complete all as specified and directed.
S&F Switch socket combination 2 in 1, 5 A flush type universal complete all as specified and directed.
S&F switch socket combination multi purpose 5 Amp /16 Amps, 5 in1, flush type complete all as specified and directed.
S&F ceiling fan regulator electronic step up type 100 Watt surface type complete all as specified and directed.
S&F ceiling rose surface bakelite 3 terminals 65x50mm complete all as specified and directed.
Removing and refixing of existing serviceable ceiling fans 1200/1400 mm sweep by painting and writing MES No. of ceiling fan with one coat of synthetic enamel paint by spraying including greasing/oiling, filling cavities with filler after cleaning all dust etc. complete all as specified and as directed.
Supply and fix LED surface back lit panel 2' x 2' 36 watts LED luminare with polymer diffuser complete with accessories Including taking down old light fitting complete all as specified and as directed.
Make : Shakti, model C-11, SZSBLMX036 36 Watts or eqvivalent make Bajaj/WIPRO/CG
Supply and fix commercial LED Suspended fittings Aluminium extruded linear channels 28 Watts 4 feet complete with accessories including taking down old light fitting complete all as specified and as directed.
Make : Shakti, model C-11, SZWXPMX028 28 Watts or eqvivalent make Bajaj/WIPRO/CG
Supply and fix LED linear Batten, 20 Watts 4 ft Polymer extruded channel, powder coated with diffuser for glare light complete with accessories including taking down old light fitting.
Make Shakti. Model No C-06 commercial SZSLBMX020 or eqvivalent make Bajaj/WIPRO/CG
S&F LED building security light fitting 20 watts with cast aluminium housing, toughened glass diffuser, IP 65/66, and wired with accessories including suitable bracket & clamps with bolts & nuts including taking down old light fitting
Make Shakti Model No S-02 szpslmm020 or eqvivalent make Bajaj/WIPRO/CG
M&L for sub main wiring with 2 single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 2.5 sqmm drawn through and including suitable size of non-metallic PVC rigid conduit with 2.5 sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up and taking down old wiring complete all as specified Including taking down old sub main wiring complete all as specified and as directed.
M&L for sub main wiring with 2 single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 4 sqmm drawn through suitable size of non-metallic PVC rigid conduit with 4 sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up and taking down old wiring complete all as specified Including taking down old sub main wiring.
M&L for sub main wiring with 2 single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 6 sqmm drawn through and including suitable size of non-metallic PVC rigid conduit with 1x6 sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up and taking down old wiring complete all as specified Including taking down old sub main wiring complete all as specified and as directed.
M&L for sub main wiring with 4 single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 6 sqmm drawn through and including suitable size of non-metallic PVC rigid conduit with 1x6 sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up and taking down old wiring complete all as specified Including taking down old sub main wiring complete all as specified and as directed.
M&L for sub main wiring with 4 single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 10 sqmm drawn through and including suitable size of non-metallic PVC rigid conduit with 1x10 sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, connecting up and taking down old wiring complete all as specified and as directed.
Note for item No 20 to 24:- 2/4 runs of cable, one run of earth wire and one run of conduit shall be measured as one unit.
S&F Sheet metal enclosure distribution box suitable for MCB'S 8 way TPN with 200 Amps rated bus bar complete including connecting up all as specified and directed Including taking down old MCB DB's complete all as specified and as directed.
S&F Sheet metal enclosure distribution box suitable for MCB'S 4 way TPN with 200 Amps rated bus bar complete including connecting up all as specified and directed. Including taking down old MCB DB's
S&F Sheet metal enclosure distribution box suitable for MCB'S 4 way SPN with 200 Amps rated bus bar complete including connecting up all as specified and directed. Including taking down old MCB DB's
S&F in replacement of Single pole and neutral Sheet metal enclosure with a two pin and earth plug and socket complete with one double pole MCB SP 20 Amps, 240 Volts, AC,50 HZ, including taking down old unserviceable plug socket, old MCB DB's complete all as specified and as directed.
S&F in replacement of triple pole and earth Sheet metal enclosure with a three pin and earth plug with socket complete with one triple pole 32 Amps, 415 Volts, AC,50 HZ, including taking down old unserviceable plug, socket old MCB DB's complete all as specified and as directed.
Supply and fix MCB TPN 6-32 Amps, 415 volt 10 KA C Curve, Including taking down old MCB's complete all as specified and as directed.
Supply and fix MCB TPN 63 Amps, 415 volt 10 KA C Curve, Including taking down old MCB's complete all as specified and as directed.
S&F MCB Single pole and neutral 240 volts 5 to 32 Amps, 10KA rupturing capacity, C series complete all as specified and directed Including taking down old MCB's complete all as specified and as directed.
S&F MCB Single pole 240 volts 5 to 32 Amps, 10KA rupturing capacity, C series complete all as specified and directed Including taking down old MCB's complete all as specified and as directed.
Material and Labour for Teak wood Board of size 2' x 2' x 4" depth, 20 mm thickness of wood, openable type with necessary hinges, two No hooks suitable for accomadate MCB TPN 4 Way -01 No, Industrial type Socket (Sheet metal enclosure) 3 Phase 01 No, & 1 phase -01 No. in Laboratory Including taking down old Teak wood Box of any type and size complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3½ core UG cable including earth work and taking down old U/S UG cable complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3½ core UG cable (Runinng on wall/floor / duct) including taking down old U/S UG cable complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3½ core UG cable runinng on wall / floor/dcukt) including taking down old U/S UG cable complete all as specified and as directed.
Excavation in trenches not exe. 1.5m wide and not exe. 1.5m in depth for laying cable and getting out as in hard/ dense soil all as specified and as directed.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soil all as specified.
Supply and spread dry river sand in trenches for cable cushioning all as specified on both top and bottom of cable including ramming all as specified and directed Note:- For the purpose of payment the punned thickness only measured.
Supply and lay un-reinforced precast concrete cable cover, class LV, Type-I flat, size 250mm x 150mm x 40 mm for cable protection all as specified and directed.
Removing the excavated soil to a distance not exe 50m and depositing where directed at a level n exe 1.5m above the starting point all as directed.
M & L for Rigid non metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessaries such as couples, lock nuts, sadles, pipe hooks etc. of size 40 mm dia running on wall/floor including taking down old U/S conduit pipe complete all as specified and as directed.
M & L for rigid non metallic PVC junction boxes of (1 to 4 way) of size 40 mm dia including taking down old U/S junction box complete all as specified and as directed.
M&L for GI pipe light grade 80 mm dia for cable protection on road crossings /plinth protection with fixed to the pole wall etc. suitable fittings for cable protection complete all as specified and as directed.
Supply, fabricating, installation, testing and commisioning Feeder Pillar Box (KIOSK) Indoor type dust & vermine proof, obtained from CPRI approved manufacturer and LT panel made out of 2 mm thick CRCA sheet front and back door openable type and suitable for operation on 415V, 50Hz, AC supply, conforming to IP-54 and fixed on angle iron frame/chanel of suitable size complete, aluminium bus bar chamber cable alley, cable glands brass crommium plated of diffrent sizes suitable for incoming and out going cable panel, painted with powder coated paint incuding necessary PCC (1:3:6) foundation extending 300mm above GL and 60cm wide platform in front of the panel including taking down old pillar box, complete all specified and directed by Engineer-in-Charge with the following accessories :- (Note: The Contractor Shall submit the drawing with sample of accessories for approval before executing the work.)
INCOMING:-
Aluminium busbar of capacity 400 Amps with eppoxy insulated supports 3 phase and neutral -1 set
MCCB 250 Amps 4 pole 25 KA with microprocessor release - 01 No
Indicating lamp set LED type - 01 set
OUTGOING:-
MCCB 125 Amps, 4 Pole 16KA fixed type - 02 Nos
MCCB 100 Amps, 4 Pole 16KA fixed type - 01 No
MCCB 63 Amps, 4 Pole 16KA fixed type - 02Nos
Supply, fabricating, installation, testing and commisioning Feeder Pillar Box (KIOSK) Indoor type dust & vermine proof, obtained from CPRI approved manufacturer and LT panel made out of 2 mm thick CRCA sheet front and back door openable type and suitable for operation on 415V, 50Hz, AC supply, conforming to IP-54 and fixed on angle iron frame/chanel of suitable size complete, aluminium bus bar chamber cable alley, cable glands brass crommium plated of diffrent sizes suitable for incoming and out going cable panel, painted with powder coated paint incuding necessary PCC (1:3:6) foundation extending 300mm above GL and 60cm wide platform in front of the panel including taking down old pillar box, complete all specified and directed by Engineer-in-Charge with the following accessories :- (Note: The Contractor Shall submit the drawing with sample of accessories for approval before executing the work.)
INCOMING:-
Aluminium busbar of capacity 200 Amps with eppoxy insulated supports 3 phase and neutral -1 set
MCCB 125 Amps 4 pole 16 KA with microprocessor release - 01 No
Indicating lamp set LED type - 01 set
OUTGOING:-
MCCB 63 Amps, 4 Pole 16KA fixed type - 05 Nos
M&L for earthing complete with copper earth plate electrode 60x60cmx3.15mm buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top dege of the plate not less than 1.5 meters below normal ground level, connected to 20X3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in elctrical plate No 3 connected to earthing test point including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with GI protection pipe including testing on completion of worrk and taking down old earthing material all as specified and directed.
M& L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20x3mm copper strip including taking down old strip of any type and size all as specified and directed.
M & L for Test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm, drilled and screwed including 3 Nos. 8 mm dia., 25 mm long hex head, screw all as specified and directed.
M/S SRI BALAJI ENTERPRISES
kamadhenu Electricals
SRI LAKSHMI CONSTRUCTIONS
eurekaenterprises
Shiva Shakthi Electrical Enterprises
Aditya Associates
RAMESH BABU CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .