Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹4.5 L
Closing Date
13 Aug 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Replacement of defective Quad cable and OFC of various sections of Danapur division. [50 Km].
DNTSnTTele2026-6
DNTSnTTele2026-6
Open
Works - General
12 Months
Patna, Bihar
₹0
₹4.5 L
13 Aug 2026
20 Jul 2026
30 Jul 2026
57 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,25,43,088.3 | ||
| — | 40000.00 | — | — | ||
| "Excavation of Trench in all kinds of soil and refilling of trenches (1.2 Mtr, Depth, 300 mm Width) - without bricks. Note:- (I) Payment will be made as per actual work done on pro rata basis, if required depth is not available at site. (II) If the depth of trench is not uniform in a span of 100 mtr.or shorter length, if site condition demands along the cable run minimum depth will be taken for that particular stretch for payment." | — | — | — | 58,54,800 | |
| — | 50.00 | — | — | ||
| Laying cable of different sizes as per cable route plan approved by Railway and meggering of all main & tail cables as per technical specification of tender.- Telecom/6 Quad cable | — | — | — | 6,36,480.5 | |
| — | 50.00 | — | — | ||
| Supply of double walled corrugated (DWC) pipes for underground power/ communication /signal/OFC protection with IS 14930 part-II along with the socket/coupler. T-Joints to be provided at the junctions wherever required.- a) Size of Outer dia 200 mm/Inner dia.175mm Inspection- Consignee | — | — | — | 52,392.5 | |
| — | 50.00 | — | — | ||
| Installation of Double Wall Corrugated (DWC) pipe with socket coupler. This includes trenching (1.2 mtr. Depth) and back filling. | — | — | — | 5,459 | |
| — | 80.00 | — | — | ||
| Supply of Thermo shrink (TSF) Jointing Kits for jointing underground quad cable as per RDSO S.no.IRS-TC-77/2010(Rev-3) with latest anendment. Inspection-RDSO | — | — | — | 2,60,800 | |
| — | 60.00 | — | — | ||
| Installation of Thermoshrink jointing kit. | — | — | — | 2,53,105.2 | |
| — | 50.00 | — | — | ||
| "Supply of 20 Pair CT box made of 16 SWG CRC sheet with disconnection and reconnection (wago type). The CT Box should be grey colour powder coated with terminal, washer, nut & bolt should be of brass. There shall also be locking arrangement. Inspection-Consignee" | — | — | — | 1,55,650 | |
| — | 1000.00 | — | — | ||
| Supply of Disconnect type Terminal,screwless, 2 IN 2 OUT (as per spec. no. RDSO/SPN/189/2004 or latest) along with all accessories including separators for fixing on Cable Termination Rack/Location boxes for Cable Termination Purpose. Inspection-RDSO | — | — | — | 1,04,750 | |
| — | 1000.00 | — | — | ||
| Fixing installation of disconnect terminal (Wago or similar) onrelay rack/ctr/location with steel carrier rail.relay rack/ ctr/ location with steel carrier rail. | — | — | — | 1,520 | |
| — | 250.00 | — | — | ||
| Excavation of trench less trench /manual boaring (size upto 110 MM) upto a depth of minimum 1.0 Meter along with dia HDPE/ DWC pipes and its accessories, all other items which will be required for laying of cable through HDPE/DWC pipes as per requirement at site. | — | — | — | 2,25,192.5 | |
| — | 7000.00 | — | — | ||
| Transportation of HDT machine with accessories including handling of stores materials, preparation of site and boring for placing of 110 MM dia HDPE/DWC pipes for crossing of S&T cable together at Bridges/ Culverts/Track/ pucca road Crossing, Boring trench shall be minimum 3 Mtr below the river bed and 1 Mtr below the Track/Road /Pucca Road crossing area. This includes supply of HDPE/DWC pipes and accessories, cost of fuels & all other items which will be required for laying of cable through it. The work shall be executed as per instruction of site engineer.- (a) Boring upto length 150 Mtrs. Inspection-RiTES | — | — | — | 92,24,110 | |
| — | 30.00 | — | — | ||
| "Casting,Concreting and Curing of foundation and erection for Half apparatus case (GKP- type) as per DRG No.SGW/MGS/L1/91 including cost of all materials required for fixing holding down bolts,casting concreting and fixing of E type lock. Note: i)The contractor will provide holding down bolts. ii) Bottom of appratus cases should be filled with sand and the top surface covered with masonry work and neat cementing. " | — | — | — | 1,92,582.6 | |
| — | 30.00 | — | — | ||
| Fixing,wiring of terminal strips, bakelite strip, transformers, relays, fuses with base and supply and fixing of shelves for half apparatus case n. (Materials other than transformers,relay,terminal strips, bakelite strip and fuses with base to be supplied by the contractor.) Supply Items- Inspection Consignee | — | — | — | 74,933.1 | |
| — | 100.00 | — | — | ||
| Miniature lock. Inspection-Consignee | — | — | — | 1,40,221 | |
| — | 30.00 | — | — | ||
| Supply of half size location box as per design of GKP signal workshop. Inspection-RITES | — | — | — | 6,40,211.4 | |
| — | 30.00 | — | — | ||
| Filling earth around location box/signal post for a width of 0.5 m on all sides, upto a level of 150 mm below the foundation top.This work includes consolidation of earth by watering. | — | — | — | 6,748.5 | |
| — | 15.00 | — | — | ||
| Supply & laying of HDPE pipe/telecom duct (outer dia 40mm As per generic requirement No.G/CDS- 08/01 Dec 99 or latest at a depth of 1.2 mtr in all type of soil. This includes transportation of HDPE/Telecom ducts from the Railway store to the site and returning left over materials to the Railway store.) Supply Inspection-RITES | — | — | — | 15,93,767.55 | |
| — | 15.00 | — | — | ||
| Supply & laying of HDPE pipe/telecom duct (outer dia 40mm As per generic requirement No.G/CDS- 08/01 Dec 99 or latest at a depth of 1.2 mtr in all type of soil. This includes transportation of HDPE/Telecom ducts from the Railway store to the site and returning left over materials to the Railway store.) Execution | — | — | — | 1,50,340.5 | |
| — | 15.00 | — | — | ||
| Laying of Optical Fibre cable through HDPE/Telecom duct for OFC by blowing as per detail in technical supplement /latest railway guidelines and advised by site engineer | — | — | — | 2,72,967 | |
| — | 25.00 | — | — | ||
| Supply & installation of OFC joint closure as per Tech. Spec. No.G/OJC-02/01Mar'99 with latest amendments & splicing of 24 Fibre Optic Fibre Cable this includes of jointing pit (RCC & Pre-fabricated) & testing and keeping in the pit then filling the pit with sand. The work will be done as per technical specifications and as advised by site engineer Supply Inspection-RITES | — | — | — | 7,89,737.25 | |
| — | 100.00 | — | — | ||
| Supply of VF Transformer (1120:470/ 1120:1120/ 470:470/470:600/ 1200:600 Ohm or as per instruction/decided by site engineer)) as per Specification Nos. IRS-TC-76/2021 Ver 1.0 or latest (Cylindrical type) or IRS/TC/22/ 2021 Ver 1.1 or latest (Rectangular type). Inspection-Consignee | — | — | — | 97,700 | |
| — | 10.00 | — | — | ||
| Electronic LC gate telephone systems with voice recorder as per RDSO Spec.no. RDSO/SPN/TC/51/ 2011 rev 1.0. a) Master telephone with in-built voice logger. Inspection-RDSO | — | — | — | 3,03,739.9 | |
| — | 40.00 | — | — | ||
| Electronic LC gate telephone systems with voice recorder as per RDSO spec.no. RDSO/SPN/TC/51/ 2011 rev 1.0. b) Slave telephone Inspection-RDSO | — | — | — | 2,78,589.6 | |
| — | 60.00 | — | — | ||
| Electronic LC gate telephone systems with voice recorder as per RDSO spec.no. RDSO/SPN/TC/51/ 2011 rev 1.0. c) 24v power pack with mf battery - 7 AH for LC gate telephone .Inspection-RDSO | — | — | — | 5,16,865.2 | |
| — | 25.00 | — | — | ||
| Supply of earth electrode material to be procured as per E.Rly sketch No. SGW/T/3/G/8/89. Inspection-Consignee | — | — | — | 49,818 | |
| — | 25.00 | — | — | ||
| Installation of Earth Electrode including MS flat for clamp etc. signalling equipments as lever frames, apparatus cases, signal, relay rack, block instrument etc. | — | — | — | 1,11,227 | |
| — | 20.00 | — | — | ||
| Supply of basic material to construct unit Maintenance Free Earth for Single Earth consisting as per Spec. Nos. RDSO/SPN/197/2016 Ver 1.0 or latest, bonding connections drawing Nos. SDO/ RDSO/E&B/002 or latest are as under,(a) Copper bonded steel electrodes of 3.0 m long, 17.0 mm diameter with copper bonding thickness of min 250 micron and UL listed and marked -1 Nos. (b) Earth Enhancement compound supplied in sealed bags of min 30-35 Kg.- 1 Nos. (c ) Copper Strip of 200mm x 25mm x6mm to exothermically welded to Earth electrode- 1 Nos.(d) Copper Strip of 300mm x 25mm x 6mm (MEEB) - 1 Nos.(e) Copper Strip of 150mm x 25mm x 6mm (SEEB)- 1 Nos. It also includes supply of (i) 35 Sq. mm Multi- strand Single Core PVC insulated Copper Connector as per IS:694 for connecting Main Earth Electrode to MEEB in the equipment room in duplicate.-10 meter (ii) 16 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting MEEB to SEEB and SPDs to MEEB.-10 meter (iii) 10 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting various equipment to SEEB- 10 meter. Inspection-RDSO | — | — | — | 4,17,640 | |
| — | 20.00 | — | — | ||
| Installation of Single Maintenance Free Earth pit as per RDSO Drawing Nos. SDO / RDSO/ E&B/001 which includes the following,a) Digging /Auguring/Boring of single earth pit of 100mm to 125mm dia. to the depth of approx. 3 meter. b) Insertion of 3.0 meter electrode and penetrating it minimum 150 mm by pushing gently with sledge hammer where the natural soil is assumed. (c) Filling of earth pit with Earth Enhancement Compound (EEC) in slurry form and backfilling. (d) Carrying out exothermic weld connection on single earth electrode to a copper tape of 200 x 25 x 6 mm. (e) Carrying out exothermic weld connection on the copper tape of 200 x 25 x 6 mm on Earth Electrode for connecting two 35 Sq. mm cables for redundancy. (f) The exothermic welding material for bonding the earth system shall be procured from RDSO approved firms, which includes graphite modules, clamps, weld metal powders etc. (g) The dimension of the chamber will be of 300 x 300 x 300 mm (inside dimension) of RCC with 50mm thick and fine finish, Inspection chamber should be as per IEC 62561-5 or latest. The top RCC cover size shall be 400 mm X 400 mm X 50mm. The date of testing and earth resistance value shall be written on the cover with black base with yellow paint or as per instruction of site engineer. Installation of above item. | — | — | — | 1,31,740 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ACS01to11GCC2022-.pdf
ATTACHMENT
ECRJPOregardingprocedureforundertakingearthworkdiggingworktrenchingworkinthevivinityofsignallingtelecomandelectricalcables1.pdf
ATTACHMENT
TenderDocumentQuadCable-OFC.pdf
ATTACHMENT
GCC_April-2022_2022__GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .