| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.7 LAccepted-Finance | L1 | Accepted-Finance that the bid is L1 | |
| 2 | L2₹26.3 L+₹2.6 L (10.9%)Rejected-Finance | L2 | Rejected-Finance that the bid is not L1 | |
| 3 | L3₹26.6 L+₹2.9 L (12.4%)Rejected-Finance MOSAT HARIPUR RD VILL P O HARIPUR DIST HOOGHLY PIN 712701 | HARIPUR | HOOGHLY | WEST BENGAL | 712701 | L3 | Rejected-Finance that the bid is not L1 | |
| 4 | L4₹26.7 L+₹3.0 L (12.7%)Rejected-Finance | L4 | Rejected-Finance that the bid is not L1 |
| Sl No | Description | Qty | Unit | ASSOCIATED ELECTRICAL CONST CO. 1963 PVT.LTD L2 | SIMPSON AND FERRIS PVT LTD L4 | GHANASHYAM ELECTRIC STORES L3 | Creative Projects L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. | 565 | Nos. | 2,760 ₹15,59,400 | 2,825 ₹15,96,125 | 2,850 ₹16,10,250 | 2,200 ₹12,43,000 Lowest |
| 2.00 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required. | 20 | Nos. | 2,700 ₹54,000 | 2,800 ₹56,000 | 2,800 ₹56,000 | 1,750 ₹35,000 Lowest |
| 3.00 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. | 25 | Nos | 4,300 ₹1,07,500 | 4,000 ₹1,00,000 | 4,500 ₹1,12,500 | 2,800 ₹70,000 Lowest |
| 4.00 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. | 25 | Nos | 8,960 ₹2,24,000 | 8,500 ₹2,12,500 | 9,000 ₹2,25,000 | 6,200 ₹1,55,000 Lowest |
| 5.00 | Supplying, installation, testing & commissioning of addressable fire control module complete as required. | 25 | Nos | 175 ₹4,375 Lowest | 2,500 ₹62,500 | 1,800 ₹45,000 | 550 ₹13,750 |
| 6.00 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel. | 2 | Nos | 2,70,000 ₹5,40,000 | 2,49,000 ₹4,98,000 | 2,40,000 ₹4,80,000 Lowest | 3,99,000 ₹7,98,000 |
| 7.00 | Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) through existing Conduit pipe with necessary arrangement as per G.S | 1,000 | Mtrs. | 105 ₹1,05,000 | 115 ₹1,15,000 | 100 ₹1,00,000 | 40 ₹40,000 Lowest |
| 8.00 | Supply & Laying of 20 mm Outer dia PVC Pipe and all accessories as required. | 200 | Mtrs. | 10 ₹2,000 Lowest | 42 ₹8,400 | 50 ₹10,000 | 20 ₹4,000 |
| 9.00 | Charges for dismantling the Siemens make Healthy 570 nos Detectors and Panel except the wiring, MCP, Hooter etc. by the C/O's own manpower and Tools & tackles from the existing system & site as per direction of EIC and refixing the same after cleaning & servicing at the place of damaged Siemens make detectors at the place as per directed by EIC. | 1 | Job | 29,985 ₹29,985 | 20,000 ₹20,000 | 24,000 ₹24,000 | 10,000 ₹10,000 Lowest |
| 10.00NOTE :- 1) The Fire Alarm system shall comply with latest requirements of -- (i) National Fire Protection Association (NFPA) Standards, (ii) IS 2189 , (iii) NFPA 70 National Electric Code, (iv) NFPA 72 National Fire Alarm & Signaling Code , (v) Local Statutory Regulations , (vi) Manufacturer Recommendation. vii) System should be integrated with the components like FACP, Detectors, MCP, Hooter, Monitor Module, Relay Module, etc. and all these components should be of same brand. viii) List of Approved Make Attached -Annexure-I | |||||||
Tender Value
₹26.7 L
EMD Value
₹53,400
Closing Date
10 Aug 2026, 1:00 pmClosed
EEI,KNHED, PW Dte
THE EXECUTIVE ENGINEER, P.W.D /KOLKATA NORTH HEALTH ELECTRICAL DIVISION
Rectification job of different make addressable type Fire Detection systems installed at different buildings of R.G. Kar Medical College and Hospital, Kolkata
2026_WBPWD_5017297_1
WBPWD/EE/KNHED/e-NIQ-28/26-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
Kolkata
Please refer Tender documents.
7 documents required · 7 mandatory
₹53,400
Office of the EE, KNHED,PW Dte
9 Sept 2026
23 Jul 2026
12 Aug 2026
23 Jul 2026
10 Aug 2026
28 Jul 2026
27 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. | 565 | Nos. | - | - |
| 2 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required. | 20 | Nos. | - | - |
| 3 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. | 25 | Nos | - | - |
| 4 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. | 25 | Nos | - | - |
| 5 | Supplying, installation, testing & commissioning of addressable fire control module complete as required. | 25 | Nos | - | - |
| 6 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel. | 2 | Nos | - | - |
| 7 | Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) through existing Conduit pipe with necessary arrangement as per G.S | 1,000 | Mtrs. | - | - |
| 8 | Supply & Laying of 20 mm Outer dia PVC Pipe and all accessories as required. | 200 | Mtrs. | - | - |
| 9 | Charges for dismantling the Siemens make Healthy 570 nos Detectors and Panel except the wiring, MCP, Hooter etc. by the C/O's own manpower and Tools & tackles from the existing system & site as per direction of EIC and refixing the same after cleaning & servicing at the place of damaged Siemens make detectors at the place as per directed by EIC. | 1 | Job | - | - |
| 10.1 | TESTS :- 1) The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system.
2) Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable Indian/International standards must be done. | - | - | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
suspension.pdf
Additional Documents • 2.91 MB
2911.pdf
Tender Documents • 1.46 MB
Annexure-I_List_Approved_Make.pdf
Tender Documents • 0.73 MB
BOQ_5087368.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .