Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹38.0 L+₹75,656 (2.03%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹41.4 L+₹4.2 L (11.2%)Rejected-Finance WZ 831 NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹43.5 L+₹6.2 L (16.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest |
Tender Value
₹41.2 L
EMD Value
₹82,460
Closing Date
30 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
PROVIDING SERVICES OF COMPREHENSIVE MAINTENANCE OF PRECISION AC (PDX) PLANT OF CAP 4 X 10 TR LOCATED AT DIPAC UNDER GE (U) PM DELHI CANTT-10
2024_MES_670178_1
GE(U)/PM/D-13/2024-25
Open Tender
Miscellaneous Works
Item Wise
DELHI CANTT-10
MES contractor enlisted under class D cat c(i). Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹82,460
Yes
26 Nov 2024
2 Sept 2024
2 Oct 2024
2 Sept 2024
30 Sept 2024
16 Sept 2024
Amount
Periodical, preventive and comprehensive maintenance of direct expansion Microprocessor based precision AC(PDX) unit of 4 x 10 TR sensible capacity precision AC unit with 5500 CFM as per the specifications air cooled condenser at underground data centre for DIPAC at Delhi Cantt for equipments as mentioned as below:- (a) DX Microprocessor based precision AC 4x10 TR sensible with 5500 CFM variable capacity scroll compressor as per the specifications air cooled condenser with stepless variable speed fans for winter operation, digital scroll compressor in each unit with refrigerant circuits & connected items. (b) PAC with bottom discharge air flow. (c) Outdoor condenser unit with copper coil with aluminum fins and social fans/speed controller motor. (d) In built sequential controller for operating unit in N + 1 configuration designed for 22 + deg (return air temperature 50% ± 5% Rh and 43°C amient temperature). (e) Electrical control panel double earthed alongwith timers for delayed start of units (03 Nos. working + 1 standby). (f) Commercial air curtains units for prevention of dust 7 conditional air losses 3 Phase 440 V, 50 Hz complete with fittings and accessories so as to produce 1 to 1 5m/sec air velocity at floor level for door opening size 58” x 90” all as specified and directed.
NOTE FOR ITEM NOS. 1.00 :- (a) The comprehensive maintenance works under this contract shall be done through respective OEM i.e. VERTIV. The contractor will have to submit MoU on stamp paper of Rs 100/- duly notarized, as specified in Performa (On serial page No. 96 & 97), within Twenty eight days from date of Acceptance of tender, failing which the contract shall liable to be cancelled and further action to be taken as per policy in vogue on account of contractors default. (b) The contractor should ensure that fortnightly periodical/ preventive maintenance services to the Eqpt/ AC unit to be carried out and submit the inspection report (duly signed by the user/ user's rep) of Equipment conducted by the OEM with in two days of visit to the Engr-in-Charge, failing which recovery of Rs. 2000/- per Equipment per visit shall be deducted from contractors dues. (c) Contractor has to carry out all major and minor break down/repairs pertains to complete machineries of Pericision AC Plant including topping of refrigreant gas as required rates quoted is deemed to be included for all except any damage due to natural disasters such as flash, floods, earth quake, cyclone etc. (d) If complaints were not attended within six hours the following penalties will be imposed and deducted from payments. :- (i) Rs. 3000/- per complaint for not attending the complaint and keeping pending from 6 hours to 12 Hour for each complaint. (ii) Rs. 5000/- per complaint for not attending the complaint and keeping pending 12 hours to 24 hours each complaint.
Material & labour for replacement of Cooling Coil/ Evaporator Coil, 6 Row, 14 Fpi, PDX, PX041-045 complete all as specified and as directed.
Material & labour for replacement of Drier, Filter, R410A, DML 305 complete all as specified and as directed.
Material & labour for replacement of Expansion Valve complete all as specified and as directed.
Material & labour for replacement of Compressor Oil complete all as specified and as directed.
Material & labour for replacement of Refrigerant gas R410a complete all as specified and as directed.
Dismatling, Lifting , Shifting for Repair/ replacement of worn out parts including Installation after repair and testing & Commisioning of PAC units complete all as specified and as directed.
P S TRADERS (BID ID -3101638)
Tushar engineers (BID ID -3105874)
V S BUILDER (BID ID -3109113)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .