| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical FUILFILL ELIGIBILITY CRITERIA |
| 2 | Accepted-Technical | Accepted-Technical FUILFILL ELIGIBILITY CRITERIA |
| 3 | Accepted-Technical PLOT NO 26 1ST FLOOR PRATAP NAGAR NEAR JAIL ROAD NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | Accepted-Technical FUILFILL ELIGIBILITY CRITERIA |
| 4 | Accepted-Technical 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | Accepted-Technical FUILFILL ELIGIBILITY CRITERIA |
| 5 | Accepted-Technical G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | Accepted-Technical FUILFILL ELIGIBILITY CRITERIA |
Tender Value
₹32.8 L
EMD Value
₹65,600
Closing Date
7 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) PALAM DELHI CANTT 10
GE (AF) PALAM DELHI CANTT 10
COMPREHENSIVE MAINTENANCE AND REPAIRS OF CENTRAL AND PACKAGE TYPE INCLUDING VRV and VRF TYPE AC PLANTS UNDER GE (AF) PALAM, DELHI CANTT-10
2025_MES_743901_1
8025-A/T-71/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) PALAM DELHI CANTT 10
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) PALAM
₹65,600
Yes
19 Jan 2026
10 Dec 2025
15 Jan 2026
10 Dec 2025
7 Jan 2026
24 Dec 2025
M&L for servicing of AHU having capacity 10,000 cfm & 9000 cfm for SMC floor mounted -06 Nos and ceiling mounted 06 Nos Make - Air Flow, floor mounting type and ceiling mounting type used in central AC plant including M&L for grinding, polishing and balancing the shaft replacement of bearings, bushes and checking alignment and cleaning and washing of cooling coil and filters for smooth functioning of AC plant complete all as specified and directed.
Supply and fixing in replacement shaft seal assembly, neoprene "O" rings of service valves, gaskets etc suitable for existing compressor complete all as specified and directed.
Nitrogn leak test of each plant by filling nitrogen gas upto 300 PSI pressure for 24 hours and vaccum the system, with vaccum pump complete all as specified and directed.
Supply and fixing in replacement strip heater 2KW as per the existing at site requirement complete all as specified and as directed by Engineer-in-Charge.
Description all as per ser item No 4 above but strip heater 3 KW complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement expansion valve as per site requirement suitable for 5.5 TR package unit complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement expansion valve as per site requirement suitable for 10.5 TR package unit complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement expansion valve as per site requirement suitable for 50 TR Chiller unit complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement expansion valve as per site requirement suitable for 75 TR Chiller unit complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of V belt suitable for blower motor/compressor (as per sample) complete all as specified and as directed by Engineer-in-Charge. Make:- Fenner/ Flexon/ Asian.
Supply and fixing in replacement of contactor Type MNX 32, 3 pole with NO-NC complete all as specified and as directed by Engineer-in-Charge. Make:- L&T/Siemens/C&S
Supply and fixing in replacement of contactor Type MNX 25, 3 pole with NO-NC complete all as specified and as directed by Engineer-in-Charge. Make:- L&T/Siemens/C&S
Supply and fixing in replacement of contactor Type MNX 12/ MNX 18, 3 pole wit NO-NC complete all as specified and as directed by Engineer-in-Charge. Make:- L&T/ Siemens/ C&S
Supply and fixing in replacement of contactor Type NC-1 18, 3 pole without overload relay complete all as specified and as directed by Engineer-in-Charge. Make:- L&T/ Siemens/ C&S
Supply and fixing in replacement of contactor Type NC-1 32 , 3 pole without overload relay complete all as specified and as directed by Engineer-in-Charge. Make:- L&T/ Siemens/ C&S
Supply and fixing in replacement of contactor Type MNX-50, 3 pole with NO-NC complete all as specified and as directed by Engineer-in-Charge. Make:- L&T/ Siemens/ C&S
Supply and fixing in replacement of contactor Type MNX-70, 3 pole with NO-NC complete all as specified and as directed by Engineer-in-Charge. Make:- L&T/ Siemens/ C&S
Supply & fixing in replacement MCB 63 Amps TPN, 415 Volts, 10 kA complete all as specified and as directed. Make:- Havells/HPL
Supply & fixing in replacement MCB 40 Amps TPN, 415 Volts, 10 kA complete all as specified and as directed. Make:- Havells/HPL
Supply & fixing in replacement MCB 32 Amps TPN, 415 Volts, 10 kA complete all as specified and as directed. Make:- Havells/HPL
Supply and filling Refrigerant gas R-407c in any installation of any capacity complete all as specified and as directed.
Supply and filling Refrigerant gas R-22 in any installation of any capacity complete all as specified and directed.
Supply and fixing in replacement of HP/LP cut out assembly complete all as specified and directed.
Opening of the existing shell and tube condenser of cpacity 3x 24 TR complete and refixing the same in the existing position after cleaning & descaling with using necessary chemical brusher with 1 HP acid circulating pump roding to be carried out in a skill manner without puncturing of copper tube etc complete all as specified and as directed by Engr-in-Charge.
Description all as per ser item No 24 above but for capacity 3x75 TR complete all as specified and directed.
Description all as per ser item No 24 above but for capacity 3x50 TR complete all as specified and directed.
Description all as per ser item No 24 above but for capacity 2x50 TR complete all as specified and directed.
Taking out existing burnt induction motor complete and material and labour for rewinding of electric motor coupled with chiller and condensor pumps of central AC plants with super enamelled copper winding wire of existing gauge of capacity 10 HP of any make including replacement of necessary ball bearings complete all as specified and as directed.
Description all as per srl item No 28 above but for capacity of pump 5 HP complete all as specified and directed.
Servicing of AHU- 02 Nos of capacity 3 x 24 TR central AC plant including M&L for grinding, polishing and balancing the shaft replacement of bearings, bushes and checking alignment and cleaning and washing of cooling coil and filters for smooth functioning of AC plant complete all as specified and as directed.
Description all as per ser No 30 above but for capacity 2 x 50 TR central AC Plant complete all as specified and directed.
Description all as per ser No 30 above but for capacity 3x50 TR Package AC Plant complete all as specified and directed.
Supply and filling/Top up of compressor oil suitable for refrigerant R-407C complete all as specified and directed.
M&L for painting of central AC plant of capacity 3 x 75 TR incl AHU', cooling tower all connected pipes, monoblock pumps etc where required to match with the existing colour with two coats of approved colours after preparation old existing surface (including repairing of existing insulation materials of refrigerant piping) complete all as per existing pattern including writing/marking complete all as specified and directed.
Description all as per Srl item No 34 above but central AC plant of capacity 3 x 24 TR complete all as specified and directed.
Description all as per Srl item No 34 above but central AC plant of capacity 3 x 50 TR complete all as specified and directed.
Description all as per Srl item No 34 above but central AC plant of capacity 2 x 50 TR complete all as specified and directed.
M&L for opening of chilled water and condenser water Y strainers and filter pots cleaning complete and refixing the same in position after cleaning of central AC Plant of capacity 3x75 TR complete all as specified and directed.
Description all as per Srl item No 38 above but central AC plant of capacity 3 x 50 TR complete all as specified and directed.
Description all as per Srl item No 38 above but central AC plant of capacity 3 x 24TR complete all as specified and directed.
Description all as per Srl item No 38 above but central AC plant of capacity 2 x 50 TR complete all as specified and directed.
Disconnecting and removing old rusted chasis of monoblock pump set and material and labour for new MS chasis of condensor and chiller pump sets and chasis made with MS channel of size upto MC 80mm x 450mm long - 02 Nos including painting with two coats of black colour synthetic enamel paint over a coat of red oxide primer including foundation bolts of size 12 mm x 100 mm with nuts, washers etc and chasis bolts of size 12 mm x 50 mm long with nuts, washers etc, including chipping of PCC for grouting of foundation bolts and grouting complete including necessry PCC and cement plaster work for repair of existing PCC foundation of monoblock water water pump sets of capacity upto 10 HP complete all as specified and as directed.
M&L for cleaning of cooling tower FRP natural draft round bottle type of capacity 3 x 75 TR, removing scale from bottom and wall of cooling tower and fungus etc complete all as specified and as directed.
M&L for cleaning of cooling tower FRP natural draft round bottle type of capacity 3 x 50 TR, removing scale from bottom and wall of cooling tower and fungus etc complete all as specified and as directed.
M&L for cleaning of cooling tower FRP natural draft round bottle type of capacity 2 x 50 TR, removing scale from bottom and wall of cooling tower and fungus etc complete all as specified and as directed.
M&L for cleaning of cooling tower FRP natural draft round bottle type of capacity 3 x 24 TR, removing scale from bottom and wall of cooling tower and fungus etc complete all as specified and as directed.
M&L for servicing of indoor and outdoor unit of Package type AC plants including oiling, greasing of fan motor and replacement of synthetic filter & checking of electric circuit 5 to 10 TR Compressor for smooth functioning of complete circuit complete all as specified and directed.
Taking out existing burnt induction motor complete and material and labour for rewinding of electric motor of outdoor units of package type AC plants with super enamelled copper winding wire of existing gauge of capacity 3 HP to 7.5 HP of any make including replacement of necessary ball bearings complete all as specified and as directed.
Supply and fixing in replacement cast aluminum fan blades with housing of size 48" dia suitable for FRP cooling tower of central AC plant complete all as specified and as directed.
Supply and fixing in replacement cast aluminum sprinkler with PVC distribution pipes, Tie Bolts with clamps and bearings suitable for FRP cooling tower of central AC plant of any capacity complete all as specified and as directed.
Supply and fixing in replacement PVC filling of size 450mm x 300mm x 150mm suitable for FRP cooling tower of central AC plant of capacity 45 TR to 225 TR complete all as specified and as directed.
Taking out microprocessor PCB of Central type AC plant of capacity 45 TR to 225 TR checking, adjusting and updating with software configuration and repairing where required including refixing to its original position after repair complete all as specified and directed. Make of Central AC Plant - Voltas.
Taking out microprocessor PCB of Package type AC plant of capacity 10 TR to 45 TR checking, adjusting and updating with software configuration and repairing where required including refixing to its original position after repair complete all as specified and directed. Make of Package AC Plant - Blue Star
Taking out PCB of Central type AC plant of capacity 45 TR to 225 TR and supply and fixing new in replacement including checking, adjusting and updating with software configuration complete all as specified and directed. Make of Central AC Plant - Voltas
Taking out PCB of Package type AC plant of capacity 10 TR to 45 TR and supply and fixing new in replacement including checking, adjusting and updating with software configuration complete all as specified and as directed. Make of Package AC Plant - Blue Star
Supply & fixing in replacement of scroll type compressor of capacity 22TR for package type AC plant complete all as specified and directed by Engineer-in-charge. Make:- Danfoss
Supply & fixing in replacement of scroll type compressor of capacity 10.5 TR for package type AC plant complete all as specified and as directed by Engineer-in-charge. Make:- Copeland
Supply & fixing in replacement of scroll type compressor of capacity 5.5 TR for package type AC plant complete all as specified and as directed by Engineer-in-charge. Make:- Copeland
Supply and fixing of front handle operated switch disconnector fuse unit type FN 415 Volt 100 Amp complete all as specified and as directed by Engineer-in-charge
S&F in replacement of butterfly valve CI 150 mm dia including rubber gasket, nuts & bolts of suitable size and existing type as per site requirement complete all as specified and as directed.
S&F in replacement of butterfly valve CI 100 mm dia including rubber gasket, nuts & bolts of suitable size of existing type and as per site requirement complete all as specified and as directed.
S&F in replacement of butterfly valve CI 80 mm dia including rubber gasket, nuts & bolts of suitable size as existing type and as per site requirement complete all as specified and as directed.
Supply and fixing in replacement of unserviceable balance valve of size 100 mm bore dia including nut, bolt, washer etc complete all as specified and as directed.
Description all as per ser item No 63 but size 125 mm bore complete all as specified and as directed.
Supply and fixing in replacement of rotational moulded PVC water storage tank cylindrical, vertical with close top hoisted and fixed in position, three layer of capacity 5000 ltrs complete all as specified and as directed by Engineer-in-Charge
Description all as per ser item No 65 but 1000 lts capacity complete all as specified and as directed.
Supply & fixing in replacement of scroll type compressor of capacity 19 TR for chiller type AC plant complete all as specified and directed by Engineer-in-charge. Make Danfoss
S&F in replacement solenoid coil kit suitable for any type of AC Plant installation complete all as specified and as directed.
S&F in replacement temperature sensor MCS T 100-20 for chiller AC Plants with syphon complete all as specified and as directed.
S&F in replacement water pressure gauge with syphon of range 0 to 100 PSI complete all as specified and as directed.
S&F in replacement of volt meter 0 to 500 Volts (Square type) complete all as specified and as directed.
S&F in replacement of Amps meter 0 to 200 Amps with CT of appropriate ratio (Square type) as per existing size complete all as specified and as directed.
M&L for replacement of MS pipe of size 50 mm dia heavy duty including jointing with electric arc welding including jointing material and fittings like flanges, gaskets etc. complete all as specified and as directed.
Description all as per ser item No 73 here-in-before but size of pipe 65 mm bore complete all as specified and as directed by Engr-in-Charge.
Description all as per ser item No 73 here-in-before but size of pipe 80 mm bore complete all as specified and as directed by Engr-in-Charge.
Description all as per ser item No 73 here-in-before but size of pipe 100 mm bore complete all as specified and as directed by Engr-in-Charge.
Description all as per ser item No 73 here-in-before but size of pipe 125 mm bore complete all as specified and as directed by Engr-in-Charge.
Description all as per ser item No 73 here-in-before but size of pipe 150 mm bore complete all as specified and as
directed by Engr-in-Charge.
Supply and fixing in replacement Refrigerant Accumulator suitable for package type AC Plant complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement drier filter suitable for package type AC Plant complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement compressor contactor 100 Amp complete all as specified and as directed by Engr-in-Charge.
Disconnecting electrically, isolating the existing unserviceable MCCB TP of any make and capacity and Supply, fixing, connecting, testing and commissioning MCCB three phase, 440 volts fixed in existing panel including necessary modification for fixing of new MCCB 630 Amp 415 V 50Hz capacity, breaking capacity 50 kA conforming to relevant IS including all jointing and connecting materials complete all as specified and as directed. Make:- Schnider/Havells/L&T.
Description all as per srl item No. 82 here-in-before but 400 Amps, breaking capacity 36 kA complete all as specified and as directed by Engr-in-Charge.
Description all as per srl item No. 82 here-in-before but 250 Amps, breaking capacity 36 kA complete all as specified and as directed by Engr-in-Charge.
Description all as per srl item No. 82 here-in-before but 200 Amps, breaking capacity 36 kA complete all as specified and as directed by Engr-in-Charge.
Description all as per srl item No. 82 here-in-before but 125 Amps, breaking capacity 16 kA complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of fan blade of outdoor unit of package type AC Plant of capacity 10 TR to 45 TR complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of nozzle for cooling tower as per existing at the site complete all as specified and as directed by Engr-in-Charge.
Supply and filling Refrigerant gas R-22 in any installation of any capacity complete all as specified and as directed.
M&L for replacement of bearings of pump motor assembly of capacity upto 10 HP complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of scroll type compressor of capacity 18 HP for VRF type AC plant complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of scroll type compressor of capacity 10 HP for VRF type AC plant complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement AHU filter of size 610mm x 610mmx 50mm for AC plant complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement AHU filter of size 610mm x 305mm x 50mm for AC plant complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement AHU filter of size 305mm x 305mm x 50mm for AC plant complete all as specified and as directed by Engr-in-Charge.
M&L for servicing of indoor and outdoor unit of Package type AC plants including oiling, greasing of fan motor replacement of synthetic filter & checking of electric circuit 22 TR Compressor for smooth functioning of complete circuit complete all as specified and directed.
M&L for servicing of indoor and outdoor unit of Package type AC plants including oiling, greasing of fan motor, replacement of synthetic filter & checking of electric circuit 5.5 TR compressor for smooth functioning of complete circuit complete all as specified and directed.
M&L for servicing of indoor and outdoor unit of Package type AC plants including oiling, greasing of fan motor replacement of synthetic filter & checking of electric circuit 10.5 TR compressor for smooth functioning of complete circuit complete all as specified and as directed.
Supply, installation, testing and commissioning of new card for SITC of main PCB card for VRF AC plant capacity 48 x 3 HP of Make Voltas complete all as specified and as directed.
Supply, installation, testing and commissioning of new card for SITC of invertor card for VRF AC plant capacity 48 x 3 HP of Make Voltas complete all as specified and as directed.
Supply, installation, testing and commissioning of new card for SITC of outdoor motor for VRF AC plant capacity 48 x 3 HP of Make Voltas complete all as specified and as directed.
Supply, installation, testing and commissioning of new card for SITC of T2B sensor for VRF AC plant capacity 48 x 3 HP of Make Voltas complete all as specified and as directed.
Supply, installation, testing and commissioning of new card for SITC of T2 sensor for VRF AC plant capacity 48 x 3 HP of Make Voltas complete all as specified and as directed.
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
tender71.pdf
Tender Documents • 0.56 MB
BOQ_832959.xls
BOQ • 0.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .