| 1 | L-1₹91.9 LAccepted-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹98.0 L+₹4.9 L (5.28%)Rejected-Finance B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L-2 | Rejected-Finance Being L-2 | |
| 3 | L-3₹99.6 L+₹6.5 L (6.99%)Rejected-Finance UNIT NO 7 MOUNT VIEW CO OP HOUSING SOCIETY LIMITED MUMBAI MANKHURD 400 088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | L-3 | Rejected-Finance Being L-3 | |
| 4 | L-4₹99.8 L+₹6.8 L (7.26%)Rejected-Finance | L-4 | Rejected-Finance Being L-4 | |
| 5 | L-5₹1.1 Cr+₹13.8 L (14.8%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L-5 | Rejected-Finance Being L-5 |
Tender Value
₹1.3 Cr
EMD Value
₹2.1 L
Closing Date
31 Jan 2024, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
SPECIAL REPAIRS TO RIGHT WING P-13 BLDG AT CABS, MANKHURD MUMBAI
2023_MES_633384_1
8855/E8
Open Tender
Civil Works
Item Rate
270 days
MANKHURD
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) MANKHURD
₹2.1 L
Yes
9 Mar 2024
19 Dec 2023
3 Feb 2024
19 Dec 2023
31 Jan 2024
17 Jan 2024
Amount
SCHEDULE 'A' PART I (B/R WORKS) M&L Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 metre means radius built in cement mortar 1:6 including demolition of brick/stone work of any mortar complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water , etc complete all as specified and directed.
M&L for 10 mm thick ready mix cement based plaster on the wall surfaces including finishing surfaces even and smooth complete all as specified and directed
M& L rendering 5 mm thick ready mix plaster on ceiling surface finished even & smooth complete all as specified and as directed.
M&L for 15 mm thick ready mix cement plaster and using WPC all as per manufacturers instructions including necessary scaffolding up to 24 m height complete all as specified ( NOTE :- WPC shall be measured and paid separately)
Supply only integral water proofing compound
Chipping, removing carefully loose/damaged concrete including plastering (total thickness upto 60mm ) from RCC surfaces of columns, beams, chajjas, soffits of slabs etc by low impact Hammer/Breaker without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land, complete all as specified and directed. Note: Hard concrete shall not be removed by force.
M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hour between the coats, complete all as specified and directed. [Note :- Mode of measurement: superficial area covered between the end to end reinforcement bars (i.e., concrete area excluding all side covers) will be measured.]
M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed . Note:- Mode of measurement: superficial area of concrete excluding all side covers will be measured.
M&L for providing mild steel TMT bars 10 mm dia and over in various structural RCC structures like column, beams and Slab etc. including cutting, bending, fixing the bars,welding with existing bars etc. complete all as specified and directed. Note: This item is applicable for additional bars required in the existing RCC structures.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application complete all as specified and directed.
M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit, while the bonding agent is still tacking upto 20mm thickness including levelling, profiling etc complete all as specified and directed.
M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Monolith-PMM) OR Polymer mortar HB of Dr Fixit, while the bonding agent is still tacking upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed.
M&L for casting & repairing of excessively damaged distressed RCC members (exceeding 60mm in thickness) with prebatched, prepacked, single component ready to use microconcrete from Fosroc (Renderoc RG) or equivalent of Dr. Fixit as approved by GE, at any level/ height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, levelling, finishing, curing etc as per manufacturer's specifications and all other relevant works, complete all as specified and directed. (Note : Items no 8 to 11 has to be done proir micro concrete). (Note: Reinforcement only shall be measured and paid separately).
M&L for Drilling and rohibb teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 10mm deep holes in structural members at the intervals of 500 centre to centre in staggered manner or as directed by Engr-in-charge in RCC structural element work shall be carried out as under:- (i) Cleaning of holes by air bowler prior to fixing nozzles. (ii) Fixing of nozzles, Insert 12mm dia Rohibb Teflon nozzles in cleaned holes, External end of nozzles to be machince to receive outlet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for minimum 12 hrs complete all as specified and directed.
M & L for Grouting injecting low viscosity high moleculer weight thermosett /monopol or equivalent polymer by pressure and using injecter with accessorises till nozzles refused the accept the grout including , mixing of materials , mixing material components quantities as per manufacturers instruction by weight batching grouting fill the grouting gun with material maintain desired pressure in the gun air by compreser maintain the pressure at exit ( 3 to 4 kg / cm2 ) by monitering pressure gauge at exit ., grout the material through pre fixed nozzles in the structural elements till its refusal . seal the nozzles with putty after the refusal , monitor leakages through other nozzles while grouting and seal them as per requirement complete all as specfied and directed.
M & L for single ply undirectional carbon fibre of 400GSM inclusive of surface preparation, priming and saturant application as per the dry lay up process and sprinkling of sand on the wet final saturant coat for giving protection screed o the top complete all as specifed and directed.
M & L for 10mm effective dia carbon fiber anchor including drilling holes of 12mm dia. 100mm deep hole across the width and length span to fiber glass treatment , of readymade glass fiber anchor with spread of 100mm . The work should be carried out with all the safety measures like helmet, safety belt and adequate labour insurance under the supervision of qualified supervisor etc... complte all as specified and directed.
M&L for leakage / seepage proof coating consisting of preparing the new/old surfaces of existing exterior walls, parapet walls, chajjas etc. and applying Primeseal primer of M/s Dr Fixit or equivalent chemical of M/s STP Ltd as approved by the GE or one coat of Chemstic PDE 600 elastomeric coating (and allowing to dry for 8hrs) under torch dry condition and subsequently applying two coats of water proofing decorative elastomeric coating system Raincoat of M/s Dr Fixit with DFT 100microns or Shalicryl 215 of M/s STP Ltd or Chemstic PDE 600 elastomeric coating (the surfaces after painting one coat shall be allowed to dry for 6 to 8hours before application of next coat) including removal of existing treatment and filling of cracks as required with approved crack filler and necessary scaffolding etc complete all as per manufacturer instructions and all as specified & directed. Notes: (i) The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE for approval.
M&L for prepration of newly plastered/concrete surface of wall and applying two coat of distemper oil emulsion on walls with one coat of primer complete all as specified and directed
M& L for preparation of newly plastered surface of Ceiling and applying two coats of oil emulsion distemper oil emulsion complete all as specified and directed
M& L for preparation of old plastered surface of ceiling and applying one coat of distemper complete all as specified and directed
M& L for complete removal of existing treatment on surfaces of walls and applying two coats of oil bound distemper over 3 mm thick wall care putty applying on walls for smooth finish complete all as specified & directed by EI C.
M&L for prepration of old plastered surface of wall complete removal of existing treatment and two coats of plastic emulsion of approved manufacturer, of required shade and colour Incuding 2 mm thick plaster of paris putty complete, as per manufacturer's specification.
M&L Preparation of old painted steel and iron surfaces of any description, not otherwise described, over 10 centimetre width or girth and applying Two coast of synthetic enamel paint complete all as specified and directed.
M & L for preparation of New steel surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer one coat of red oxide zinc chrome primer complete all as specified and directed.
M & L for preparation of old painted wood surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
M&L for Reinforced cement concrete (nominal mix) Type B1 1:2:4(20 mm graded aggregate) for Chullah hoods; stairways (except spiral staircases) inncluding steps (square or spandril), string pieces, carriages, etc., complete, any section straight or winding,including demolition of cement concrete ,(reinforced) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and as directed.
Demolition cement concrete (unreinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L 75 mm thick Cement concrete type D2, 1:4:8 (using 40 mm graded aggregate) of flooring finishing cement concrete surface even and smooth using extra cement complete all as specified and as directed
Demolition of stone slabs and tiles laid beded and pointed in any mortar of any description or thicknes in floors , aprons etc
S&F Vitrified light shade ceramic tiles 10 mm thick (square/rectangular) polished, area of each tile not exceeding 0.36 sqm ,in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match including 15mm thick bedding layer of CM 1:6 complete all as specified and as directed.
All as per items No above but in skirting or in dado including 10 mm thick rendering in CM 1:4 complete all as specified and directed
M & L for Coloured Glazed ceramic tiles in vertical surface 350 x 250 mm x 7 mm / 450 x350x 7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering in CM 1:4 as in backing coat complete all as specified and directed.
M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed with coloured cement to match the shade complete including 15 mm thick CM 1:6 screed bed for laying floor finishes all as specifed and directed..
M&L for coloured Non-skid digital ceramic tiles 600x600x6 to 7mm thick (square/ rectangular) of approved size, in floors etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 15mm thick cement mortar screed bed in CM 1:6 etc, complete all as specified and directed.
M&L for coloured 300x600x7 to 8mm thick digital ceramic tiles on vertical surfaces such as skirting,dado etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 10mm thick cement mortar backing coat in CM 1:4 etc complete all as specified and directed.
M&L for Durastone Heavy Duty (parking) tiles (300x 300) x 10-12 mm thick in floor set and jointed with neat cement slurry and pointed in coloured cement to match over screed bed or bedding layer 20 mm in cement mortar 1:6 etc complete all as specified.
M&L for 12-15mm thick dholopur tiles of size 200x100mm fixed in vertical surfaces over rendering of 10mm thick in cement mortar 1:4 set and jointed in cement slurry and pointed in white or coloured cement to match with existing complete all as specified and directed.
M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15 mm thick screed bedding layer in CM 1:4. including machine moulding and polishing of the edges complete all as directed.
M & L for Machine cut cudappah stone slab 20mm thick over cement screed base, laid and mixed with pigment to match the shade of the slab window cills and jambs to full thickness of wall fixed in steps over cement screed bed 10mm thick in CM 1:4 and jointed with grey cement paste and slurry including rubbing and polishing complete all as specified and directed
M&L Machine cut kota stone slab flooring 20-25mm thick over 15mm thick cement screed bed in CM 1;6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. Note : For stairs and steps threads full length kota slab with double line grrove cuts at edges shall be provided.
M&L Machine cut kota stone slab flooring 20-25mm thick in riser of steps, skirting, dado and pillar over 15mm thick cement mortar rendering bedding in CM 1;4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. Note :For stairs and steps risers full length kota slab shall be provided.
S & F for hot dipped GI imposed grid with 24mm wide T section exposed flanges powder coated frame work comprising of main runner made from 0.33 mm thick GS sheet of size 24mmx32mmx3000 mm @1200 mm C/C GI wire 4mm dia fixed by rawl plug,level adjusters and screws etc flush fitting of 1200mm long cross tee interlocked between main runners @ 600mm c/c to form 1200mmx600mm modules cross tee longer than 600 mm to be supported independently 600mmx600mm modules shall be formed by fitting 600mm long cross tee centrally between 1200mm cross tee ,perimeter wall angle shall be GS of size 19mmx19mm and 0.45 mm thick 300mm long including 600mmx600mmx8 to 10mm thick armstrong gypsum reinforced board with painting with two coats of plastic emulsion paint over primer including dismantling boarding any description fixed in any position with nails complete all as specified and directed.
M & L for filling of lean concrete 1:5:10 type E2 (using 40 mm graded stone aggregates ) in sunken portion, as per requirement including demolition of Concrete of any description and in any position not otherwise specifically provided for or lean concrete from sunken floor including floor tiles, hacking of surfaces after cleaning with wire brush (floor and adjoining walls) and disposing off debris outside MOD land complete all as specified and directed.
M & L for special treatment for sunken portion of WCs/Bath & toilet etc executed in following stages : Stage 1: Providing 15mm thick plaster in CM 1:3 mixed with water proofing chemical of Dr.Fixit or Shalicrete 'R' of STP Ltd in the proportion/quantity all as per manufacturer's instructions. State 2 : Primer-Mix Tarfelt LM of STP Ltd (diluted with water in ratio 1:1) @ 250 gms/sqm and apply the primer on the plastered surfaces. Stage 3 : Application of 1st coat of Tarfelt LM of STP Ltd (without dilution with water) @ 1Kg/Sqm by brush all as per manufactuer's instructions. Stage 4: Laying fiber glass cloth (weight not less than 50gram/ Sqm) over the 1st coat while the coated surface is still sticky. Stage 5: After 6 to 7 hours interval, apply second coat i.e. final coat of Tarfet LM of STP Ltd (without Dilution with water) @ 1kg/ Sqm by brush as per manufacturer's instructions. Stage 6: Providing 10mm thick protective plaster in CM 1:3 mixed with STP No. 1 @ 250ml/50 Kg cement all as per manufacturer's instructions. Stage 7: Carryout ponding test for 48 hours to ensure water tightness of repaired sunken portion. NOTES :(i) Mode of measurement: Actual area treated (floor and adjoining walls) will be measured and paid . (ii) The above treatment shall be got executed through applicator of manufacturer and necessary authenticated documents on account of above shall also be produced by the contractor.
Supply and fixing of 20 mm outer diameter CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches including taking up or down steel water tubing and connections of size 15mm bore complete all as specified and directed.
M&L brick walls cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends of edges of landings,steps, cills, sunshades, lintels etc. and cutting chases for concealed water tubing and making good ,cutting not exc 10 cm girth complete all as specified and directed.
Supply & fix 20mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors,including taking up or down steel water tubing and connections of size 20 mm bore complete all as specified and as directed.
S&F 150 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls including dismantling cast iron or reinforced concrete drain pipes , water pipes any description complete all as specified and directed.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls all including dismantling cast iron or reinforced concrete drain pipes , water pipes any description complete all as specified and directed.
S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls incl dismantling cast iron or reinforced concrete drain pipes , water pipes any discription all complete all as specified and directed.
S &F PVC (SWR) bends, 150 mm bore, any radius
S &F PVC (SWR) junction single(single T), 150 mm bore, equal or unequal
S&F 110mm bore PVC (SWR) any radius
S &F PVC (SWR) bends, 75 mm bore, any radius
S &F PVC (SWR) junction single(single T), 110 mm bore, equal or unequal
S &F PVC (SWR) junction single(single T), 75 mm bore, equal or unequal
S&F in repairs cast iron Nahani trap 100mm dia out let including grating connecting jointing to waste pipe with lead jointing and taking out existing unserviceable traps by hacking out concrete joints and making good of surfaces complete all as specified and as directed .
S&F PVC connections 15mm size with PTMT nuts of length 600mm
S&F in repairs 15 mm bore stop cock cast copper alloy with crutch or for brass chromium plated with fancy shank and cup(concealed type) complete all as specfied and drecetd.
S&F in repair 10 ltr,PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet,ball valve, float and handle including brackets, complete all as specified and directed.
S&F in repair Tubular towel rail, D type, 60cm long between flanges fixed with and including chromium plated brass screws and wooden/plastic cleats Make :Jaquar code No AKP-35711PS
S&F in repair Towel ring Square flanges fixed with and including chromium plated brass screws and wooden/plastic cleats Make :Jaquar code No AKP-35721PS
S&F in repair Soap dispenser with glass bottle, flanges fixed with and including chromium plated brass screws and wooden/plastic cleats Make :Jaquar code No AKP-35735PS
S&F in repair Toilet paper holder with stainless steel flap, flanges fixed with and including chromium plated brass screws and wooden/plastic cleats Make :Jaquar code No AKP-35753 PS
S&F in repair Glass shelf 600 mm long, flanges fixed with and including chromium plated brass screws and wooden/plastic cleats Make :Jaquar code No ACN -1171 N
S&F in repair Corner Glass shelf with bracket, flanges fixed with and including chromium plated brass screws and wooden/plastic cleats Make :Jaquar code No ACN -1173 N
S&F in repair Soap dish holder, flanges fixed with and including chromium plated brass screws and wooden/plastic cleats Make :Jaquar code No ACN -1131 N
S&F in repairs two way Bib cock long body with wall flange fitted by 15mm bore complete all as specified and as directed.Make :Jaquar code No COP -041PM.
S&F in repairs 15 mm bore stop cock cast copper alloy with crutch or for brass chromium plated with fancy shank and cup fancy type complete all as specfied and drecetd.Jaquar code No COP -057PM.
S&F in repairs Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms)
S&F A Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
S&F in repairs 15 mm bore fancy type chromium plated bib taps, cast copper alloy with crutch or butterfly handle, screwed down screwed for iron pipe or for brass ferrule fixed
S&F Bib cock Auto closing system with built in control cock with wall flange fitted by 15mm bore complete all as specified and as directed Make :Jaquar code No PRS -043
S&F in repairs Vitreous china squatting pan orrisa pattern of size 580 x 440mm with integral foot rest and 'P' or 'S' trap including lime concrete bedding connecting flushing pipe and taking out old WC pan & lime concrete and unserviceable connections and making good for floor etc complete all as specified and as directed
S&F in repairs Pedestal pan Couple closet Cat NO LYS-WHT-0204BS and soft seat cover cat No ZPS-WHT_1027UF including removing old wc complete all as specified and as directed Make :Jaquar
S & F for Vitreous china wash down water closet pan “Pedestal Pattern” white, with seat coverwhite closed pattern with flat bottom and cover mild steel chromium plated or aluminium anodized hinging device and joints etc and connection to drain, flushing pipe, anti-syphonage pipe and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concrete 1:2:4 type B-0, as in repairs, complete all as specified and directed.
S & F in repair Vitreous China urinals, HAlf Stall(back or corner wall type), complete including providingand fixing plugs, bedding urinal against wall in cement mortar1:2, securing urinal to plugs withand including 60mm long brass screws, pointing around urinalback in cement; fixing automatic flushing cistern with brackets,flush pipe, grating and Union fordischarge pipe. (Exclusive offixing supply pipe to flushing cistern, trap and waste pipe) , pointing around urinal back in cement complete all as specified and directed
S & F in repairs Vitreous China Wash hand basin white, flat back, size 550x400 mm size (flat back or angle back type)excluding taps, waste, chain and plug and procelaim stopper but including cutting for and pinning ends of brackets or erecting stand.including taking down pillar tap complete all as specified and directed
S&F vitreous china, table top wash hand basin oval shape size( 420x420mm x135 mm) cat No : ARS-WHT-0538 Make of JAQUAR fixed on granite counter top slab including brass chromium plated full threaded waste coupling with grating 32mm dia pvc waste pipe including removing old wash basin complete all as specified and directed. (Note: Granite slab, RCC plat form, brick wall support etc shall be measured and paid separately)
S&F 15 mm Bore dia Pillar taps fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specfied and directed.
S&F 15 mm Bore dia Pillar taps fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specfied and drecetd.cat No : COP -CHR-021PM Make of JAQUAR
S&F Urinals valve auto closing system with built in control cock &wall flange ( pressmatic) long screwed shanks including spreader and fly nut screwed for 15 mm bore pipe, complete all as specified and as directed
Removing plant/growth including its roots upto 1.00m of plant height at any location/at any storey and of any description and treating the surfaces with Acid (HCL) and making good surfaces with cement mortar 1:4, complete all as specified and directed.
Taking down chowkats or frame with shutters ( without taking off shutters from the frame ) not exc 1.5 Sqm each complete all as specified and directed.
Taking down and refixing of shutter in same opening exc 1.50 sqm not exc 4.00 sqm each complete all as specified and as directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with Square tube, supply and fixing in opening as per specification given under SSR Part II 2020 including making good the disturbed surface complete all as specified and directed. Make: SYNTEX/SHALIMAR/RAJSHRI
M&L for factory made solid PVC panel type PVC door shutter 30mm thick consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rails, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent supplying and fixing in the frame at site as per specifications and drawing given under SSR Part II 2020 complete all as specified and directed. Make : SYNTEX/SHALIMAR/RAJSHRI
S&F Factory Made Solid PVC Moulded Door Shutters with wood free EPS 28 to 30 mm thick (stile:), with 2,4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing
S&F 100 mm long mild steel butt hinges medium weight fixed with stainless screws complete all as specified and directed.
S&F aluminum anodised barrel tower bolts of extruded section of size 150 mm length
S&F 150 mm extruded aluminum alloy handles, fabricated type anodised
S&F aluminum anodised sliding door bolts with hasp and staple ( bolt type ) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminum alloy, length of bolts 250 mm.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 all as specified & directed.
Demolition of brick/cement concrete (unreinforced) / pcc tiles from existing roof/terrace etc and also removing/taking down of existing water proofing treatment of any thickness in any position including cleaning the surfaces of roof etc with wire brush complete and removing the retreived debris out side MD land complete all as specified and directed.
M&L for PCC (1:2:4 ) type B-1 using 20 mm graded crushed stone aggregate as in levelling courses over RCC roof surface to achieve required slope including rounded or chamfered edges mixed with water proofing compound @ 3% by weight of cement and finishing surface even and smooth using extra cement etc complete all as specified (NOTE :- WPC shall be measured and paid separately as supply only )
M&L for screed bed 10 mm thick on brick work or concrete surfaces finished even and fair in cement plaster 1:4, complete all as specified and as directed with mixing water proofing compound.Note:( wpc shall be measured and paid separately)
M & L for 3 mm thk APP modified roof treatment over existing roof slab etc to be executed through approved authorised applicator of the membrane manufacturer with the following specifications complete all as specified and directed:- (a) Applying oil bound bitumen primer @ 0.40 litre/ Sqm manufactured by the same manufacturer as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on the prepared dry surface. (b) Laying APP modified water proofing membrane reinforced with non woven polyester fibre weight not less than 160gm/Sqm using butane torch by torch application with 10cm side lap and 15cm end lap. (c) Physical properties of membrane shall be as under:- (i) Membrane weight not less than 3.50 Kg/Sqm. (ii) Non woven polyester weight not less than 160gm /sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650N/Sqcm and transverse not less than 450 N/Sqcm (v) Tear strength-longitudinal not less than 300 N & transverse not less than 250 N. (vi) Elongation : > 20% in both directions. (vii) Impermeability/water tightness at 2 Kgf/cm2. (viii) Water absorption - Not more than 1% on mass within 24 hours. (ix) Cold flexibility - Minimum (-) 20C. (x) Dimentional stability % change = Maximum 1%. (xi) thickness of memberane shall not less than 3 mm. Note bitumen primer will be meaasured separately
Bitumen primer for use in water proofing and damp-proofing treatments
M&L PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in hold fast, bed plate etc including necessary form work complete all as specified and as directed.
Taking down existing aluminium joinery of any description (frame/ shutters) with all fittings (but excluding grills) complete all as specified and directed.
S&F standard aluminium section powder coated (minimum thickness of powder coating shall be 50 micron and colour shall be as approved by GE ) as in frame, shutters for doors, window / ventilators, fixed / openable / sliding or in any pattern, cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass, provision of hinges, screws, plugs, handle, lock, roller, Nylon ball bearing etc complete all as specified and directed (Aluminium section shall be of make Jindal/Hindalco/ Indalco) Note:- Weight of Aluminium sections as per actual or as per IS or as per manufacturer, whichever is less, shall only be considered for payment. Cost of other items / accessories required for entire completion of the work shall be deemed to be included in the quoted rate. However glass panes, shall be measured and paid separately as supply only under respective item.
Taking down existing aluminium grill of any description (frame/ shutters) with all fittings and fixing it existing position complete all as specified and directed.
S & F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and directed.
Supply only 4.80mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane with including wooden/rubber beading or gasket for aluminium section complete all as specified.
Supply only stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm , fixed in aluminium windows complete all as specified and directed.
Supply 12 mm thick prelaminated both sides with decorative choice laminations particle board, exterior grade,prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber/ aluminium frame work complete all as specified and directed.
S F for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed
S&F for aluminium (Die cast body) hydraulically Door closer regulated, designation No. 1 universal type, suitable for door shutters of 701 to 850 mm in width and and of weight not more than 35 kg and fixed in repairs.
S&F Toughned glass 12 mm thk as in hinged doors , partitions autometic doors and similar work including cutting to shape, drilling holes required including adequate locking system fixed at bottom of door panel.
Supply only 30 cm long ornemental type stainless steel door handles fixed to 10/12 mm toughened glass door pattern and design as approved by GE.
M&L Providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment along external wall where the apron is nor provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and directed.
At points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.05 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as specified and directed.
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting platesFe-410-W(Gde-E-250)quality-B including dismantling wrought iron or mild steel work of any description complete all as specified and directed.
S & F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling old shee complete all as specified and directed.
S&F in repairs Polycarbonate Hollow sheet 10mm thick of an colour having tensile strength of 60.30 MPa as in roof covering/cladding to wall, fixed with self tapping screws and including aluminium channel strip including dismantling old sheet complete all as specified and as directed by Engineer in charge(.Note: Colour is approved by GE)
S & F for Solid PVC Wall Lining one side prelam consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing.
S & F for 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed.
SCHEDULE 'A' PART I (E/M WORKS) M & L for point wiring complete with proper colour coding using, 1100 Volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked drawn in and including PVC conduit concealed in wall, ceiling etc with all accessories, fittings, PVC junction boxes etc, sunk pressed steel boxes not less than 2 mm thick, 50 mm deep terminal boxes covered with 3mm thick plastic laminated sheet top cover fastended with chromium plated brass screws, also including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for one light point /fan/bell point controlled by one one way switch, complete including taking down of old unserviceable worn out wiring, socket and fittings etc all as specified and directed. Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid as one unit.
-ditto- all as per item No.120.00 above but for One 2pin/3 pin socket outlet 5 Amps on same board complete all as specified and directed.
-ditto- all as per item No.120.00 above but for One 2 pin/3 pin socket outlet 5 Amps on independent board.
M&L for point wiring using proper colour coding with 1100 Volts grade, 2.5 Sqmm PVC insulated, FRLS, unsheathed, wire confirming to IS-694, Part-II, ISI marked with multistranded copper conductor drawn in and including PVC conduit concealed in wall, ceiling etc with all accessories, fittings, PVC junction boxes etc, sunk pressed steel terminal box not less than 2 mm thick, 50 mm deep, covered with 3 mm thick plastic laminated sheet top cover fastened with chromium plated brass screws, also including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, multistranded, copper conductor 1100 Volts grade, green color, continuous earth wire connected to common earth dolly for 15 Amps, 3 Pin, socket outlet independent complete all as specified and directed. Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid as one unit.
S&F Switch piano, flush type, single pole, one way, 6 Amps, 240 Volts with ISI mark complete all as specified and directed.
S & F switch socket combination 2 in 1, 6 A flush type, 240 Volts, with ISI mark complete all as specified and directed.
S&F switch socket combination, ISI marked flush type multipurpose 3 pin, 6 and 16 amps, controlled by one switch all as specified
S & F ceiling rose surface bakelite, 65x50mm, three terminals with ISI mark complete all as specified and directed.
S&F electronic, step (5 Step) type fan regulator 230 volts stepped and flush type and connecting up with ISI mark complete all as specified and directed.
Taking down old unserviceable ceiling fan 1200 mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades and transporting to workshop to undertake repairs by rewinding of burnt out winding using suitable gauge copper wire, replalcement of worn out capacitor 2.0 mfd - 01 No., PVC canopy - 02 No and bearing including scrapping of old paint and applying two coats of synthetic enamelled white paint over a coat of red oxide primer complete and refixing back at site with new clamps, nuts, washers, safety wire of size not less than 1.00mm & bolts including cotter pin for complete all as directed.
Supply and fix in repairs high speed Ceiling fans complete with aluminium blades, down rods, PVC Canopy and accessories, white in colour 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value min 6.00, BEE Five star rated with brushless direct current motor(BLDC) without remote complete including taking down old unserviceable fan to MES store all as directed by Engr-in-Charge. Make : Havells (Efficiencia Neo (BLDC 26 W) /Orient (FALCON 400) / Bajaj (ENERGOS 28) Note : Unserviceable ceiling fans shall be deposit to MES store.
S&F in Repairs/Replacement Surface and wall mounted Pre-coated CRCA housing box type luminaire suitable for T8 LED tube light 18/20 watts, 230 volts, including fixing mounting blocks 2 Nos, end caps made up with engineering plastic & 1.5 sqmm 3 core PVC insulated copper conductor cable including fixing arrangements and taking down old rusted bracket fittings complete all as specified and directed. Make : Bajaj - BLRB-DB 118 I or equillant of Wipro/Jaquar Note : LM 79 & LM 80 Test certificate from NABL certified Lab shall be submitted by the contractor for LED luminaire along with warranty certificate for 3 years from OEM
S&F in repairs Highly effcient ULTRON LED tube with Polycarbonate T8 housing designed for high performance 18/20 Watt with in built driver with metal heat sink, double sided connection, 230 volts including fixing arrangements and taking down old unserviceable tube rod complete all as specified and directed. Make : Bajaj - BLRB 18W CW LED or equillant of Wipro/Jaquar Note : LM 79 & LM 80 Test certificate from NABL certified Lab shall be submitted by the contractor for LED luminaire along with warranty certificate for 3 years from OEM
S & F in replacement of 36 W surface mounted light of size (1x4 ft) having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. Make : Bajaj/wipro/Jaquar Note : LM 79 & LM 80 Test certificate from NABL certified Lab shall be submitted by the contractor for LED luminaire along with warranty certificate for 3 years from OEM
S & F in replacement of 36 W ceiling recessed light of size (2x2 ft) having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. Make : Bajaj/wipro/Jaquar Note : LM 79 & LM 80 Test certificate from NABL certified Lab shall be submitted by the contractor for LED luminaire along with warranty certificate for 3 years from OEM
Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC made out of engineering plastic batten with white acrylic cover sleek designb& high efficiency for wall & surface mounted applications comprising with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make : Bajaj/wipro/Jaquar Note : LM 79 & LM 80 Test certificate from NABL certified Lab shall be submitted by the contractor for LED luminaire along with warranty certificate for 3 years from OEM
S&F in repair single pole and neutral enclosure with a two pin and earth and metal clad plug socket complete with one single pole MCB 20 Amp 240 Volts complete including taking down old us enclosure all as specified including concealing in wall and directed. Make-: Indo Asian/ Schneider/ C &S/ Legrand.
Supply & fix in repairs GI cable tray with cover of size 300 mm X 100 mm (Appx 2.0 mm) including spacers, screws, saddles for fixing the trunking in wall/GI sheets of shed complete all as specified and directed.
M&L in repairs of sub main wiring with two single core 6.0 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping with and including PVC insulated 4.0 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly complete including taking down old us submain all as specified and as directed Make of casing caping-: Sudhakar/Precision/ Diamond, Make of wire-: Finolex/ Havells/ Polycab/ KEI Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid as one unit.
-ditto- all as per item No.138.00 above but for 4.0 sqmm complete all as specfied and directed.Make of casing caping-: Sudhakar/Precision/ Diamond, Make of wire-: Finolex/ Havells/ Polycab/ KEI
-ditto- all as per item No.138.00 above but for 1.5 sqmm complete all as specfied and directed.Make of casing caping-: Sudhakar/Precision/ Diamond, Make of wire-: Finolex/ Havells/ Polycab/ KEI
S & F in repair MCCB DB TPN 6 way, double door, vertical type, IP - 43 suitable for Triple pole 125A MCCB including connecting up with cable, lugs, Bus bar, Din rail , Neutral link etc complete including taking down old unserviceable DB all as specified.Make-: Schneider/ L&T/ Legrand/ ABB/ Havells
-ditto- all as per item No.141.00 above but TPN 4 way complete all as specified and directed.
S & F in replacement MCB DB 8 way SPN, double door, vertical type, IP - 43 with 200 Amps rated bus bar, AC and connecting up complete including taking down old us DB all as specified.Make-: Schneider/ L&T/ Legrand/ ABB/ Havells
-ditto- all as per item No.143.00 above but SPN 12 way complete all as specified and directed.
S & F in repairs MCB SP 6 to 32 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity 'C' series.Make-: Schneider/ L&T/ Legrand/ ABB/ Havells
S & F in repairs MCB SPN 40 Amps, 240 / 415 Volts, 50 Hz, 10 KA Breaking capacity 'C' series.Make-: Schneider/ L&T/ Legrand/ ABB/ Havells
S & F in repairs MCB TP up to 32 Amps, 415 Volts, 50 Hz, 16 KA Breaking capacity 'C' series.Make-: Schneider/ L&T/ Legrand/ ABB/ Havells
S & F in repairs MCCB TPN 125 Amps, 415 Volts, 50 Hz, 16 KA Breaking capacity 'C' series. Make-: Schneider/ L&T/ Legrand/ ABB/ Havells
-ditto- all as per item No.148.00 above but MCCB TPN 100 Amps,415 Volts, 50 Hz, 16 KA Breaking capacity 'C' series complete all as specified and directed. Make-: Schneider/ L&T/ Legrand/ ABB/ Havells
Supply and fix in repairs exhaust fan made of sturdy Engineering plastic complete with rasin body and blades, louvers shutter, voltage 230V, 50 Hz, RPM 1270, Copper winding of sweep 250 mm air delievery 780 cum/hr etc complete all as specified and directed. Make- Orient (Model - 70049) or equivalent of Bajaj/ Crompton.
Supply and fixing in replacement of LED security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection 4 kv surge in built protection complete all as per directed by Engr- in – charge. Make : Bajaj/Crompton/wipro/Jaquar Note : LM 79 & LM 80 Test certificate from NABL certified Lab shall be submitted by the contractor for LED luminaire along with warranty certificate for 3 years from OEM
M & L for Taking down of aluminium/copper strip of any size laid as roof conductor, down conductor, earth contunity conductoor including air termination rod from any position / location of sheds/ buildings of height up to 30 meter & refixing the same after straightning the conductor/removal of bends, including replacing the old insulators with new one and saddles etc complete all as specified and directed. Note -i) The quoted rate is deemed to inclusive of T & P/scaffolding/staging etc for executing the work in buildings of height up to 30 meter. ii) The rate is deemed to be inclusive for providing Procealin insulator, screws, Plugs iii) PCC Block required shall be measure and paid under respective items
Supply & fixing for Aluminium strip 25 x 3.15mm on wall/ roof/ batten or recessed or buried in ground including all insulators, screw, nut bolts with saddles and fixing for roof conductor and down conductor complete all as directed by Engineer-in-Charge.
M&L in repairs for test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 nos. 8 mm dia, 25mm long hex. head screw.
Supply & Fixing in repairs air termination Copper rod 12 mm dia, 300 mm long for lightening conductor including base plate with all necessary nut bolts and drilling job etc.
Supply and fixing of GI pipe light grade of size 40 mm bore for laying in trenches/floors or walls including all fittings for fixing complete as required and directed by Engineer-in-Charge.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site and refixing back at site with new clamps, nuts, washers, holders, connectors, wires are deemed to be inclusive in the quoted rate complete all as directed.
Taking down carefully from existing position and undertaking of water servicing to both outdoor and indoor unit, cleaning of cooling coils, outdoor fan blades, tightning of doors terminations, wires etc and refixing back in old location of split type 1.5 TR/ 2.0 TR air conditioners complete all as specified and directed.
Supply & fixing in repair copper piping with foam insulation suitable for supply and return air for split type AC of capacity 1.5/ 2.0 TR having folowing sizes complete:-
Supply and fix in repair PVC drain pipe of size 5/8" bore for supply pipes for air conditioners complete all as specified and directed.
Supply and fix in repair Heavy duty Water Proof Powder coated mounting bracket for installation of outdoor unit of air condiioner made out of 2 mm thick high grade steel with suitable fastener, MS nuts, bolts M8 x 45mm, washer, bolt M8 x 30mm nut, bolts & washers etc. duly painted complete set all as specified and directed. Make :- Companion Sleek, Aircool Sales Corporation or equivalent .
M & L in repairs for earthing chemical with copper plated 50 mm dia pipe 3 mtr long (100 microns) including Electrodite 50 Kg buried directly in ground including earth bore hole work (earth bore not less than 3 Mtr deep below normal ground level and connected to copper earth strip of size 20×3 mm by means of copper nuts bolts with washers and connected as per following specifications complete all as directed by Engineer-in-Charge. (a) In -Pipe Technology, Designed & Manufactured using M.S Pipes, Outer Dia is 50 mm with a wall thickness of 2 mm, Inner Dia is 26 mm with a wall thickness of 2.6 mm, Overall Length is 3000 mm, External Corrosion Protection: Copper Plated (100+ microns), Internal Corrosion Protection: In addition to Copper Plated (100+ microns), a ground breaking corrosion resistant Crystalline Conductive Compound is filled and compacted in the cavity within the pipes to enhance the electrodes performance. Conforms to IS: 3043 - 1987 i.e., Code Of Practice For Earthing (+ 10%) variations in dimensions applicable. (b) Electrodite backfill: Manufactured using Eco - Friendly minerals, Blended homogeneously with conductive carbon(s), Resistivity: < 5 ohm-metre (In ideal moist conditions); > 5 ohm-metre (Dry Conditions), Ph Value: 7.0 - 8.5, High water retention capacity, Hygroscopic, Ionic & Electronic conduction, Swells when it comes in contact with water thereby engaging constant contact between the electrode surface & soil which is a crucial aspect in the performance of an earthing system. Packing Size: 25 kilograms, Recommended for normal soil conditions. Conforms to IS : 3043 – 1987. Make: Ashlok or any ISO Certified approved make.
S&F in repairs copper strip of size 20 x 3.15mm including welding, brazing and taking down of old copper strip as required at site, complete all as specified and directed.
S&F Motion Sensor Switch consisting of sensitivity detector with wide detection field, integrated circuit, having automatism (day & night), convenience, safety, saving- energy and practicality functions of power indication and detection indication. Operation on receiving human motion infrared rays on entering the detection field, comprising of following features and specifications as give under :- Specification: (a) Power Source: 110 -220V/AC (b) Detection Range: 360° (c) Power Frequency: 50Hz (d) Working Temperature: -20°C~+40°C (e) Ambient Light: 3-2000LUX (adjustable) (f) Working Humidity: <93% (g) RH Time-Delay: min: 10sec±3sec Max: 7min±2min (h) Installation Height: 2.2-4m (j) Power Consumption: 0.45W (work) 0.1W (static) (k) Rated Load: 1200W (incandescent lamp) 300W (energy-saving lamp) (l) Detection Motion Speed: 0.6 ~1.5m/s (m) Detection Distance: 6m max (24°C) Function: (a) Identification of day and night: (b) Consumer adjustable work ambient light. (c) Work in the daytime and at night are adjusted on the "sun" position (max). (d) Ability to work in the ambient light less than 3LUX on adjusted on the "moon" position (min). (e)Time-Delay is added continually on receipt of second induction signals after the first induction (f) Having compute time once more on the basic of the first time-delay rest. (g) Adjustable time delay having minimum time is 10sec±3sec. & maximum is 7min±2min as per requirement complete all as specified & directed. Make: Anchor (Panasonic)/ Impact (Honeywell)/ or equivalent.
Vishal Builders
Joy builders
Modern Engineering Co
M/s Shree Construction Co
M/S K N Rai
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .