Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-AOC HN 2 PREETI NAGAR PHASE II FAIZULLAGANJ LUCKNOW UTTAR PRADESH 226020 | LUCKNOW | UTTAR PRADESH | 226020 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹33.3 L+₹4.9 L (17.4%)Rejected-Finance 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | L2 | Rejected-Finance Being Higher Bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
21 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT OF LT INFRASTRUCTURE SYSTEM AT CH (CC), BASE HOSP AND OTHER AREA IN THE AREA OF AGE E/M (HOSP) UNDER GE E/M LUCKNOW
2022_MES_519951_1
GE/EM/LKO/HOSP/T-13 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹80,000
Yes
18 Jun 2022
26 Apr 2022
23 May 2022
26 Apr 2022
21 May 2022
9 May 2022
60 days
Amount
Supplying and laying or fixing in replacement, jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
All as per item No 1 above but of size 10 Sqmm 4 core
All as per item No 1 above but of size 16 Sqmm 4 core
All as per item No 1 above but of size 25 Sqmm 3.5 core
All as per item No 1 above but of size 50 Sqmm 3.5 core
All as per item No 1 above but of size 95 Sqmm 3.5 core
All as per item No 1 above but of size150 Sqmm 3.5 core
All as per item No 1 above but of size185 Sqmm 3.5 core
S&F in replacement Straight through joints (Heat Shrink Kits) for LT underground cable outdoor type complete for Armoured ,PVC sheathed Aluminium conductor cables Including excavating earth, identifying the fault, making proper joint of cable after rectification & returning soil back to earth for 3.5 core cable 25 to 50 Sq mm complete all as specified and directed.
All as per item No 09 above but 3.5 core cable 70 to 150 Sq mm
All as per item No 09 above but 185 sqmm to 300 sqmm 3.5 core
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified and directed. Note :- Punned thickness shall only be considered for payment
M&L laying fly ash bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified and directed.
Boring/Drilling ( horizontally) manually under existing road ( maximum 10 M in width) suitable for passing GI tubing of 40 to 80 mm bore complete all as specified and directed.
S & F GI tubing 'Light' grade 40 MM for cable protection fixed in poles/walls/laid under roads/crossing etc incl taking out the rusted pipes of following sizes, complete all as specified and directed.
All as per item No 18 above but size 50 mm bore dia
Material & Labour for preparation of old painted surface of steel tubular pole (9/11/12) meter long above coping) and applying two coat of aluminium paint, making of strip of 20 cm width (sky blue and white in alternate band) upto 1400 mm height with one synthetic enamel paint , rewriting pole No by painter with enamel paint, and painting the existing MS clamp with one coat of aluminum paint complete all as specifeid and directed.
Material and labour for writting of Pole Nos on existing pole with stencil out with white colour in sky blue colour background of 80 mm hight around the radius of pole and complete all as specified and directed.
Supplying and fixing in repair flat twin core ,1.5 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified and directed.
Supplying and fixing in repair flat twin core ,2.5 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified and directed.
Supplying and fixing in repair flat twin core ,6 sqmm nominal cross sectional area multistranded aluminium conductor FRLS cable, PVC insulated and sheathed 1100 Volts grade complete all as specified and directed.
S&F MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 100 AMPS complete all as specified and directed.
S&F MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 125 AMPS complete all as specified and directed.
S&F MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 160 AMPS complete all as specified and directed.
S&F MCCBs four pole 36 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 200 AMPS complete all as specified and directed.
S&F MCCBs four pole 36 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 250 AMPS complete all as specified and directed.
S&F MCCBs four pole 36 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 400 AMPS complete all as specified and directed.
Power contactor 4 pole Type Mcx 32 , Fr size 2 rating AC 1 rating 160 A, 50HZ including dismantling the unserviceable contactor, complete all as specified and directed.
Power contactor 4 pole Type Mcx 23 , Fr size 1 rating AC 1 rating 40A, 50HZ including dismantling the unserviceable contactor, complete all as specified and directed.
Digital type Volt meter , 3 ph , class 1 including taking down unserviceable voltmeter, complete all as specified and directed.
Digital type Ammeter 3 ph , 5 Amps , class 1 including taking down unserviceable ammeter, complete all as specified and directed.
Indicator lamps (LED Type) including taking down unserviceable indicator lampsall, complete all as specified and directed.
S & F in rep MCB’s single pole with neutral, 6 to 32 Amps, 250 volts with 'B" curve, fixed in existing PVC box including connecting complete all as specified and directed.
Rep/Maint/servicing of LT ACB 4 pole of capacity 1250 Amps 50Ka including rep/maint of minore rep complete all as specified and directed.
Dismantling the existing unserviceable ( damaged/broken) LT street light swaged poles / RCC poles or unserviceable tilted steel pole of any size, and Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed.
Restreching only existing LT OH/ HT OH lines consisting following lines of ACSR and GI wire , any size and tightening with aluminium binding wire 2/4/5/6 Lines of ACSR and 1 line of GI wire complete all as specified and directed. Note :- (i) Linear length centre to centre of the poles shall only be measured (ii) Cleaning / pruning of tree branches falling around the conductor shall also deemed to be included in the quoted rates
S & F Offload change over switch, 200 Amps, 415 volts, 4 pole in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all specified & directed.
S & F On load change over switch, 63 Amps, 415 volts, 4 pole side handle type in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all specified & directed.
S & F Off load change over switch (side operated handle) 400 Amps, 415 volts 4 pole in sheet metal enclosure with interlock door and pad lock facility including dismantling of existing change over switch, complete all specified & directed.
S & F street light panel single phase up to 6 kw load with Astronomical digital timer and MCCB of capacity 32 / TP and SPN 40 Amps fixed on wall/pole with clamps,nutbolts all as specified and directed Make havells Cat part no. IHXSS0106A or eqvlcnt make as per PS
S&F MCCBs four pole 36 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 630 AMPS complete all as specified and directed.
M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply, installation, testing and commissioning of Polycrystaline Photovoltaic Module of 315Wp each.The PV modules used must qualify to the latest edition of IEC PV module qualification test or equivalent BIS standards. Crystalline Silicon Solar Cell Modules IEC 61215. In addition, the modules must conform to IEC 61730 Part-1 - requirements for construction & Part-2 requirements for testing, for safety qualification or equivalent IS. I-V curve of module at STC should be provided by bidder.The total solar PV array capacity should not be less than allocated capacity (kWp).The module frame shall be made of corrosion resistant materials silver anodized aluminium alloy.The bidder shall carefully design & accommodate requisite numbers of the modules to achieve the rated power. The module junction box should not be less than IP67 protection.The manufacturer should warrant the Solar Module(s) to be free from the defects and/or failures specified below for a period not less than ten(10) years from the date of sale to the original customer. The make of Solar PV modules should be : TATA/Havells/Panasonic
Supply and fixing (in repair) integral dome type white coloure plastic boty of size 300 mm suitable for fixing on 80 mm pipe post top lanterns including suitable for 1x25 W CFL including making connections complete complete all as specified and directed.
M & Labour for tracing out LT Cable fault of any size any Location in the area of the AGE E/M hospital by cable fault fault locater Machine and mark location , Excavation for Joints and refilling removal complete all as specified and directed. Note - Joint Will be measure and paid respective Item.
Supply, fixing, connecting and testing energy efficient LED blolard light of 18 Watt including foundation work with PCC as required complete all as specified and directed.
Supply, fixing, connecting and testing energy efficient LED Garden landscape view LANTERN WITH SYMMETRIC LIGHT DISTRIBITION AND LIMITED UPWARD LIGHT COMPONENT light of 18 Watt complete all as specified and directed.
S & F in repair cast Aluminum extra heavy pole designer leg and broader designer base finished with polyurethane paint (with proper treatment) daimeter of one leg is 88 mm outer dia for spigot entry 75 mm 03 nos T shaped bolts with nuts & washer provided for concrete foundation . Total length of the pole incl base and legs (base with plate X04 nos Legs) is 3100 mm 10 feet 2 inch ) complete all as specified and directed.
S & F in repair fully cast Aluminum finished with polyurethane paint (with proper treatment) hexagonal junction box with maximum projection breath of 575 mm suitable for two number post top lanterns for 02 meter and 2.5 pole complete all as specified and directed.
S & F in repair fully cast Aluminum finished with polyurethane paint (with proper treatment) with acryclic window cover. Total lenght 933 mm (36.75 inch) & max breath 323 mm (12.75 inch) including B22 brass holder provided with aluminum cover and spigot entry 78/90 mm ans suitable for 30 to 50 watt LED bulb complete all as specified and directed.
S & F in replacement fully cast Aluminum finished with polyurethane paint (with proper treatment) squire junction with maximum projection breath of 625 mm suitable for two number post top lanterns for 2.5 meter and 3.0 Pole complete all as specified and directed.
M/S S.B. Singh and Sons
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .