RequiredOEM Authorization Certificate Bid to RA enabled No Computer Servers ( 1 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Specification Form Factor Tower Tower Size (RU) 5 * Processor Make Intel Intel Max. Number of sockets available on chipset 2 2 Max. Number of sockets populated with processor 2 2 Number of core per 12 12 1/4 Processor Processor Configuration Intel Xeon Silver 4116 ( 2.10GHz/12-core/16.5M B/85W) Intel Xeon Silver 4116 ( 2.10GHz/12-core/16.5M B/85W) Chipset compatible with CPU - * Availability of Co- Processor No * If Yes Co-Processor Configuration NA Tesla V100 SXM2 32GB
RequiredNA PCI Slots (Express Gen 3.0) 6 * Type of RAM DDR4 * RAM Size (GB) 64 64 RAM upgradable upto (GB) 1536 1536.0 - 24000.0 Or higher DIMM Slots (No.) 16 * Type of Hard Disk Drive SATA SATA Hard disk drive Capacity (GB) 12000 12000.0 - 12000.0 Or higher Hard disk drive Speed (RPM) 7200 * RAID Controller Cache (MB) 0 * RAID Type 0 * RAID Controller Ports @12 Gbps 0 * Video Controller (support VGA or above resolution) Yes * Keyboard No * Mouse No * Bays (min. 2 internal or more hot plug) 4 * USB Ports (version 2.0/3.0) 5 * Certifications Compliance support by Windows
RequiredRed Hat or Novell or Oracle Cluster or Linux or AIX S/W Yes * DVD ROM (or better) NA * Network Card Supported 1G * 2/4 FC HBA Dual port card NA * FC HBA Dual port card Speed NA * Power Management - * Redundant Power Supply No * Redundant Fan No * Total No of Ports - * Declare SPEC int_rate_base 2006 ; specfp_rate_2006 or latest for 1
Required2
Required4
Required8 prcessor as applicable - * Server scalability to be achieved within the box without adding nodes Yes * RoHS Compliance Yes * BIS Registration number & its Validity - * Max. power consumption of the system (Watt) 1200 * Availability of Type test reports consisting of verification of all the features & functional parameters & environmental tests sequences as under: a Dry heat test (For 16 hrs at a temperature of 45 degree C in accordance with IS: 90 00/part-3/section-5/197 7) b Cold test(For 4 hrs at a temperature of 0 degree C in accordance with IS: 9000/part-2/sec tion-4/1977 c Damp Heat Cyclic Test ( For 2 cycles of 24 hrs at a temperature of 40 degree C & 95% RH in accordance with IS: 90 00/part-5/section-1/198 1) Note:- The server shall be checked for all the parameters before conditioning
RequiredAfter completion of the above environmental No * 3/4 tests sequence
Requiredwith a recovery period of 1 to 2 hrs
Requiredthe server shall be functional Name address of Lab - * Test Report No. date - * Power Supply 230 V +/-10%
Required50 Hz * On Site OEM Warranty (years) 3 3
Required5 Or higher * Bold specifications are the golden parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.