Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.7 LAccepted-AOC FLAT NO 7 MHAMBRE BLDG DR FRANCISCO LUIS GOMES ROAD VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹48.4 L+₹42,443.50 (0.88%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L5₹51.4 L+₹3.4 L (7.11%)Rejected-AOC | L5 | Rejected-AOC Rejected | |
| 4 | L5₹51.7 L+₹3.7 L (7.63%)Rejected-AOC H NO 767 NEAR OLD POST OFFICE NEW VADDEM VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L5 | Rejected-AOC Rejected | |
| 5 | L6₹51.9 L+₹3.9 L (8.16%)Rejected-AOC | L6 | Rejected-AOC Rejected |
Tender Value
₹49.7 L
EMD Value
₹99,500
Closing Date
5 Feb 2024, 6:00 pmClosed
GARRISON ENGINEER GOMANTAK
GARRISON ENGINEER GOMANTAK VASCO
Spl rep of Staff Qtr bldg No P268 at NOI Replacement of certain existing water tank at NOI Provn of elect sup for ASHORE accn for inliving sailors for ships stationed at Goa and Spl rep of static water tank No 1 2 and 4 at NAD Goa under GE Gomantak
2024_MES_637564_1
8588/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
VASCO DA GAMA
As per tender documents
8 documents required · 8 mandatory
₹500
GE GOMANTAK
₹99,500
Yes
21 Jun 2024
15 Jan 2024
7 Feb 2024
15 Jan 2024
5 Feb 2024
30 Jan 2024
Amount
Excavating in trenches n exc 1.5 m wide and n.exc 1.5 m in depth, for Foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting gout.
PCC (1:4:8) type D-2 (Using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete, complete all as specified and directed.
M & L for precast cement concrete block masonry with solid block exc 10 cm in width and setting in CM (1:6) 1:3:6 type C-1 using 20mm graded stone aggregate.
PCC type B-1 1:2:4 (20 mm graded crushed stone aggregate) as in coping, bed plates etc slightly rounded or chamfered angles and throating, complete all as specified and directed.
M&L for 15 mm thick plastering on brick/concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified
M&L for preparing new plastered surfaces and applying two coats of cement base paint on surfaces of walls.
Demolition of Concrete unreinforced of any description and in any position not otherwise specifically provided for complete all as specified and directed
M& L for 75 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in plinth protection or similar places surfaces finished even and fair without using extra cement
Dismantling of floor hearth or wall tiling including cement bedding (not backing) removal serviceable filed to store
M&L for Demolition of Cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) →
M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.
M& L Brushing neat cement slurry with 3.0kg of cement per sq. metr
Taking down,easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws,etc and refixing in same opening , shutters of any description exc 1 sqm and n exc 2 sqm each Shutters of any description n exc 1 sq. m each all as specified and directed.
M&L for PCC 1:2:4 type B-0 (Using 12.5 mm graded stone aggregates) of 40 mm thick as in leveling course ,finished surfaces even and rough to receive floor finish complete all as specifed and as directed.
M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but no texceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including over screed bed or bedding layer of mortar 15 mm thick laying floor finished in cement mortar 1:6 complete all as specifed and as directed.
M&L for mat finish ceramic coloured tiles 7 to 8 mm mm thick area of each tile exceeding 0.18 sqm not exceeding .38 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including over screed bed or bedding layer of mortar 15 mm thick laying floor finished in cement mortar 1:6 complete all as specifed and as directed.
M&L for glazed ceramic coloured tiles of size 350x 250x 7 mm/ 450X 350X 7mm thick thick over and including 10 mm thick rendering in cement mortar 1:4 as in backing coat for tiles on vertical surfaces,set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specifed and directed.complete
M&L for Chequered cement concrete tile 20 cm x 20 cm x 25 cm thick, set jointed and pointed in neat cement slurry in floors and cut and polished with grey cement and pigments cluding over screed bed or bedding layer of mortar 15 mm thick laying floor finished in cement mortar 1:6 complete all as specifed and as directed.
Taking down existing treatment along with PCC padding of any thickness incl removing Old roof any pattern and roughening surfaces of old concrete roof padeling by picking, sweeping clean and washing down with water to remove dust etc. complete.
M&L for 15 mm thick plastering on brick/concrete surfaces in cement mortar 1:4 using mixed with and including integral waterproofing chemical PIDIPROOF LW mixed in proportion 200 millilitre per 50 Kg cement of DR FIXIT of PIDILTE INDUSTRIES LTD or STP No. 1 (LIQUID) as in padding on roof surface for correcting / making proper slope on roof, surface finished fair and even without using extra cement complete and finished (including up to 4th storey building) complete all as specified and as directed by Engineer-in-Charge. Note: Water proofing compound shall be not measured & not paid separately.
Supplying and applying High build elastomeric waterproofing coating based on pure, hydrophobic polyurethane, cold applied of spray / brush applied, membrane with an elongation of 550% and tensile strength of 2.5 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm as per ASTM C1305, no leakage upto 7 bars of water pressure as per DIN 1048, shore A Hardness of min. 45 as per ASTM D 2240. The system includes final base preparation, water based primer and applying SmartCare PU Magnum or approved equivalent in two to three coats to achieve a min. thickness of 1.2mm, etc. complete as per Manufacturere specifications
Filling and reinstating of separation cracks: Opening the separation cracks at the junction of RCC and masonry where ever directed and instructed into "V" Grooves 2 to 3" from either side of the cracks by carefully marking areas to be opened up using a cutting machine and skillfully/carefully chiseling with a well sharpened chisel and hammer as directed including wire brushing and washing of concrete substrata and masonry walls with water jet to the surfaces thus prepared to the entire satisfaction of the consultant as instructed and directed. Moistening the cracks, provinding and applyin priming/bonding coat of slurry made out of "Polyalk EP" and cement (or equivalent as specified in the list of brand names) in proporiton 1:1 to surfaces prepared as instructed and directed. Filling the cracks/grooves by providing and applying "Polyalk EP" Polymer modified cement mortar (or equivalent as specified in the list of brand names) in proporiton 1:5:15 (Polyalk EP: Cement: Graded Sand/Quartz Sand) on the prepared surfaces and finishing it in the level with the existing plaster including hand packing, curing and making the surface similar to the external plastering using wooden floats/punch etc. complete all as specified and directed.
Dismantling of loose portion of concrete from ceiling and S&F of wiremesh of weight 2.5kg/sqm and apply 25mm average thickness in CM(1:4) mixed with liquid integral WPC (complast 'X' recommended by the manufacturer with guniting machine at a pressure not less than 5kg/sqm finally rendering 10mm thick plaster in CM (1:4) using WPC (Complast 'X' 421 i.e. from M/s Fosroc and nitobound AR from M/S Fosroc or equivalent as approved by GE ) in the proportion recommended by the manufacturer complete all as specified and directed.
Taking down cement plastering on brick or stone walls including raking out joints hacking for key scrubbing down with water etc inside shafts all as directed by Engr-in-Charge.
Providing and applying 15mm thick ready mix external sand faced cement plaster with neat cement rendering at all locations in two coats of masonry (except stone masonry) and concrete surfaces including providing water proofing compound to the first coat of plaster as per manufacturers specification, inclunding racking out joints, hacking of concrete surface, finishing, curing, and neccesary scaffolding etc complete.
Supply only liquid water proofing compound @ 0.200 Ltr per 50 Kg of cement or as per manufacture instruction completed all as specified and directed.
M & L for Apply a coat of SmartCare Primero with dilution ratio of 1:1 with water maintain a coverage of 100 sq.ft/ltr iclunding removing all durt and filling cruck surface with water proofing chemical mixed with CM 1:3 on wall complete as per Manufacturere specifications
M&L for applying two coats of Advanced Anti-algal Weather/dampProof 100% Acrylic smooth emulsion with silicon additives, over a coat of fibre reinforced elastomeric liquid water proofing membrane including preparation of New plastered surface complete as per Manufacturere specifications Make: Asian paints Ultima Suprema+ Damp proof or eqlt.
Preparation of old surface of wall by scrapping / rubbing, applying two coats of Advanced Anti-algal Weather Proof 100% Acrylic smooth emulsion with silicon additives, over a coat of fibre reinforced elastomeric liquid water proofing membrane incl filling cracks surfaces with water proofing compound complete as per Manufacturere specifications Make: Asian paints Ultima Suprema+ Damp proof or eqlt.
Chipping off existing loose, damaged concrete from RCC members of all affected RCC Columns, beams, slabs and chajjas on external and internal facades etc beyond main r/f.(if required in the opinion of the consultant), carefully with chisel and hammer including relieving structural members such as column, beam and slabs of their superimposed load partially or fully by provision of adjustable steel props, frames etc. Providing and applying "Rusticide SS' Rust passivator or equivalent as specified in the Brand names to existing r/f bars including wire brushing of r/f, cleaning, washing of concrete etc complete as directed. Providing and applying two coats of rust preventor slurry made out of "Polyalk Fixoprime" or equivalent as specified in the brand names and cement in proportion 1:1.5 to exising r/f bars as directed complete. Providing and applying bonding coat of slurry made out of "Polyalk EP" or equivalent as specified in the brand names and cement in proportion 1:1 to concrete and r/f substrates complete as directed. Providing and applying 'Polyalk EP' or equivalent as specified in the brand names. Polymer modified cement mortar in required porportion (1:5:15) to RCC members including hand packing, curing and making the surface rough for plastering.
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates. Fe-410-W(Gde-E-250) quality-B).
Providing and applying 12mm thick ready mix internal sand faced cement plaster with neat cement rendering at all locations in two coats of masonry (except stone masonry) and concrete surfaces including providing water proofing compound to the first coat of plaster as per manufacturers specification, inclunding racking out joints, hacking of concrete surface, finishing, curing, and neccesary scaffolding etc complete.
Material & Labour for applying two coat of oil emulsion distemper on new surfaces of wall over a coat of primer over wall care putty including perparation of surface by complete removal of distempered and painted surfaces complete.
Material & Labour for applying two coat of oil emulsion distemper on old surfaces of wall over a coat of primer over wall care putty including perparation of surface by complete removal of distempered and painted surfaces complete.
M & L 5 mm thick rendering in cement mortar 1:3 on ceiling finished even and smooth without using extra cement complete all as specified and directed
M&L for 3mm thick putty on ceilling surfaces and applying two coat of oil bond distemper and preparation the surfaces complete all as specified and directed
M&L for 3mm thick putty on old ceilling surfaces and applying two coat of oil bond distemper and preparation the surfaces complete all as specified and directed
M/LReplacement of steel reinforcement with TMT CSR bars of appropriate size where 20% of cross section is reduced including dismantling of rusted steel including application of rust converter FEOVERT and applying protective coating IPNET-RB complete all as specified and directed by Engr-in-Charge.
Providing and laying Super fluid microconcrete-Roffe crete repairs (or equivalent as specified in the list of brand names) in beam bottoms, columns, slabs etc. including mixing with 5mm to 10mm size aggregates, water proof plywood/steel plate shuttering, pouring, tamping, consolidating, curing etc complete as per manufacturer's specification and consultant's instructions. The item shall be paid on actual consumption of microconcrete.
M/L Formwork to sides and soffits of floor or roof beams, beam haunch- ings, girders, bressummers, lintels, column ,cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
Taking down Chowkhats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames)
Taking down Chowkhats or frames exc. 1.5 sq. m but m. exc 4 sqm each with shutters (without taking off shutters from the frames).
Supply and fix aluminium powder coated frame and shutters for partition/windows/ventilators/doors slidiing/fixed/openable type complete with necessary fittings such as two aluminium handle cum lock for each window, roller etc and fixing all as specified and directed by Engineer-in-Charge.
S&F glazing with 4 mm thick sheet glass ordinary type including rubber beddings/gasket around glass panes all as specified.
S&F aluminium anodised wire mesh of size 1.5 mm x 3 mm mesh 20 Gauge thick of make M/S Kiran Netting or equivalent as approved by GE.
S&F Deco-102, Anodised aluminium grill (anodised transparent or dyed to required shade according to IS 1868 with minimum anodic coating of grade AC 15 of approved design/ pattern with approved standard section and fixed to the existing window frame with CP brass/ stainless steel screw @ 200 mm centre to centre including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete as per requirement and direction of engineer in charge
S & F framed work such as grills gratings etc. with ends of bars shouldered and/or revited to forged into spikes, framed guard bars etc conforming to FE-290 Gde E-165 fixed with fasteners all as specified.
M&L one coats of syenthtic enemel paint paint over a coat of red oxide primer including preparation of untreated New steel surfaces.
M&L for one coat of synthetic enamel paint on old painted steel surfaceof any description not otherwise describe over 10 cm width or girth including preparation of surfaces complete all as specified and as directed by Engineer in charge
M&L for PCC type C1 1:3:6 (using 20 mm graded aggregate) for filling the holes of the hold fasts.
S &F 2nd class H/W Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at junctions all as specified.
S& F MS flat iron 25 x 3 mm as in hold fast for fixing if chowkats.
S&F Flush shutters, 30 mm thick solid core construction, with block board core and plywood face panels, commercial type on both sides
S&F second class Hard wood, 30 mm thick, glazed skelton shutter, open rivetted & prepared, with sash bar, divided into square with plane chamfered or rounded, mitred and rivetted sash bars any numbers.
M& L for Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life
S&F factory made solid PVC Moulded door shutter 30mm thick(stiles) with 2 mm thick Moulded PVC sheet on the front face & 2 mm plain colour PVC sheet on back faces,and with particle board core supplying and fixing in frame at site as per specification and drawing.
M & L floor door stopper of aluminium alloy body and tongue, anodized with rubber washer at bottom fixed with screw to body and fixed to door shutter, over all length of cover plate shall be 150mm mm complete all as specified and directed.
M & L for two coat of synthetic enamel painting over new preperation of wooden surface over 10 cm width or girth
S&F alumiunium allloy, anodized, sliding door bolt, 300 mm, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed (isi marked).
S & F butt hinges medium weight cold rolled mild steel 100 mm long (isi marked)
S&F 125 mm long Aluminium, anodised, barrel tower bolts of extruded section.
S & F 150 mm long Aluminium handles, cast type (ISI marked).
Taking up or down 25mm dia steel tubing and connection including cleaning for re-fixing or removal from site complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store of 20 mm bore size complete all as specified and directed.
Supplying and laying of CPVC pipes 20mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors,including all fitttings complete all as specified. complete all as specified and directed
Supplying and laying of CPVC pipes 25mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors,including all fitttings complete all as specified. complete all as specified and directed
S & F 15mm pillar taps, long nose fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed in repair approved by GE
Dismantling of water tanks exc 250ltrs and n exc 500 ltrs and removing to store complete all as specified and directed.
S&F rotational moulded polyethylene water storage tank (cylindriacal vertical with closed top) hoisted and fixed in position all as specified in SSR part-I of capacity 1000ltrs including 20mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball and nipple screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair brass Chromium plated shower roses of 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
S&F in repair CP towel rail with hook 600mm long complete all as specifed and as directed.
S & F in repairs vitreous china squating pan, Orissa pattern of size 580 X 440 mm white with integral foot rusts incl all necessary fittings all as directed.
S & F Vitreous China Urinal, Half stall type,white (excluding flushing cistern, flush pipe and waste pipe)
S&F in repair Vitreous china wash hand basin (550X400mm) white, flat back excluding taps, waste chain and plug and porcelain stopper but including brackets complete all as specifed and as directed.
S&F in repair 32mm bore waste fittings brass chromium plated for glazed ware sinks basins etc with long screwed shanks and fly nuts, flange and bedded in red lead cement and othter end fixed complete all as specifed and as directed.
S&Fr for 10 ltrs capacity PVC valve less syphonic action type flushing cistern low level white inlet ball valve, float , flush pipe and handle including brackets and fixed complete all as specifed and as directed.
S&F in repair PVC connection 15mm dia and 600mm long complete all as specifed and as directed.
S&F in repair PVC waste pipe 32mm dia complete all as specifed and as directed.
S&F in repair 15 mm bib tap CP fancy type with crutch or butterfly handle screwed down for iron pipe or for brass ferrules and complete all as specifed and as directed.
S&F in repair 15mm bore chromium plated brass angle cock /stop cock screwed for iron pipe or union and fixed complete all as specifed and as directed.
S&F PVC floor trap with grating suitable for 100 mm dia outlet and jointing to waste pipe in cement concrete type B1 (1:2:4) complete all as specified.
S&F Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern all as specified and directed.
S&F for PVC (SWR) pipes 110 mm dia single socket in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F for PVC (SWR) bend of any radius - 110 mm dia complete all as specified and directed.
S&F for PVC (SWR) bend of any radius - 75 mm dia complete all as specified and directed.
S&F in repairs soap dish fixed with chromium plated brass screws complete all as specified and directed.
S&F 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate complete
S&F mild steel rolled section as in main and cross beams hips and jack rafters perlins where connected to comman rafter including cutting,welding etc complete all as specified and as directed ( Confirming to Fe 410, W (Gde-E-250)
Dismantling plain corrugated steel sheeting any gauge thickness including Nainital and similar pattern complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Demolition/breaking of sewage pipe in trenches in foul condition of 150 mm dia
Demolition of concrete block walling, stone masonary built in cement mortar including all quoins archas pillars etc and pre-cast block walling etc complete all as specifed and directed.
Excavation in trenches n. exc. 1.5m wide and n. exc.3 m deep; in hard/dense ; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 sq.m on plan and n. exceeding 3m in depth and getting out.in soft/disintegrated rock
PCC (1:3:6) type C-2(Using 40 mm graded coarse aggregate) as in bed to 300mm bore drain pipe including packing under, and honching aginst the size of pipe after they are laid and tested all as specified .
M&L Reinforced concrete pipes, class NP2, 300mm bore laid and jointed complete with collars all as specified .
Mild steel TMT bar 6mm to 8mm dia cut to length bend to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (unnealed) not less than 0.9mm dia or securing with clips, compl
Mild steel TMT bars 10mm dia and over cut to lenth bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Returning and filling in, including spreading, leveling, watering and well ramming in two layers not exc 25 cm thick in any type of soil, complete all as specified and directed.
Removal of excavated material to a distance exc 1.50 km but not exc 5 Km depositing where directed at a level not exc 1.5 mtr above the starting point.
Demolition of block masonry built in cement mortar in any description complete all as specified and directed.
M&L for Pre-cast cement concrete block masonry with solid blocks type C1 1:3:6 (20mm gaded aggreage), exc. 10 cm in width and setting in cement mortar 1:4, complete all as specified and directed.
M & L rendering 15mm thick on block masonry surfaces in CM 1:4 to be finished even and smooth (without using extra cement) including cement plaster 1:2 setting coat 3mm thick trowelled to even and smooth using WPC all as specified.
M & L for 100mm thick cement concrete type B-1, 1:2:4 using 20mm graded aggregate as in sub base of floor.aggregate as in floors
M&L for 75mm thick cement concrete type B-0, 1:2:4 using 12.5mm aggregate as in flooring and plinth protection etc, finished even and smooth using extra cement and mixed with water proofing compound complete all as specified and directed
S&F for compound girders and stanchions, lattice girders, areial mast, staging for water tanks and the like including caps, bases, splices etc built up from two or more beam or channel section or angle with plates, inluding all lattice bars stifeners, gusset plate etc of Fe-410W Gde E-250) quality-A complete all as specified and directed.
S&F for 4mm dia galvanised steel wire 150x100mm mesh made up into mattresses for cages, papped wired and laied in position, including closing after filling complete all as specified and directed.
M&L for applying two coats of Synthetic Enamel paint over a coat of red oxide primer on newly prepared steel surfaces complete all as specified and directed.
S&F for 25mm gun metal globe or gate valces, with iron sheel head screwed both end for iron pipe and fixed.
M&L for applying two coats of Dr. Fixit Dampgaurd with water in 1:0.5 ratio and allowed to dry including preparation and cleaning of surfaces by removing of dust, dirt etc. all as per manufacturer's instructions (application with authorised & approved applicator only)
M&L for supply and fix purever (Pharminox) stainless stell watertank of 1000 Ltr capacity of stainless steel material depth of tank 1750mm inner dia 970mm, outer dia 1070mm, lid dia 420mm, intel connection 25mm, overflow connection 25mm and outlet connection 40mm and including all related accessories and pepartation of base and fitting onroof all as specified and al directed by Engr-in-Charge
S&F 20mm Chromium plated,fancy type, stop/gate valves/angle valve screwed down,high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed in repair approved by GE
S&F 25mm Chromium plated,fancy type, stop/gate valves/angle valve screwed down,high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed in repair approved by GE
Taking down carefully aluminium point wiring (light, fan, socket, bell or power) complete including all fittings and fixtures, removing, materials from site and making good disturbed surfaces of wall, ceilings etc.
Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and draw into and including rigid non-metallic PVC conduit of 20mm dia or higher,and including all PVC conduit accessories concealed into wall by cutting of chases in wall/ceiling and including replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc complete all as specified and directed for one light/fan point controlled by one, one way switch 06 Amps ,Note-Rate is inclusive of Cutting/chases of wall/floor/ceiling.
All as per item No 2 but 2/3 pin socket out let 5 Amps with 1.5 Sqmm on independent board.
All as per item No 2 but 2/3 pin socket out let 5 Amps with 1.5 Sqmm on same board.
All as per item No 2 here-in-before but for 2 in 1 three pin socket outlet 15/20 Amps on independent board with 4 Sqmm cable FRLS copper conductor multistranded including 4 sqmm PVC insulated and unsheathed FRLS copper conductor cable as earth continuity wire all as specified and directed by Engr-in-Charge.
Supply & Fixing modular switch 1 way 6A, 1 module, 230 volts.
Supply & Fixing modular switch one way 16 Amps, 1 module, 230 volts.
Supply & Fixing modular socket 6 Amps-2/3 pin combined, 2 module.
Supply & Fixing modular socket 6A/16A-2/3 pin combined, 2 module.
Supply and fix ceiling rose surfaces bakelite 65 x 50 mm three terminals including supply and fix PVC plate or square blocks.
Supply & Fixing in replacement of stepped type 2 module modular electronic fan regulator flush type including removal of old one.
Supply & fixing in replacement of MCB, 6 to 32 Amps, single pole, C Series, 10 KA, 240 volts.
Supply & fixing in replacement of MCB, 6 to 32 Amps, single pole neutral, C Series, 10 KA, 240 volts.
Supply & Fixing in replacement of MCB protected socket of 20 Amps with sheet metal enclosure including plug top of 25 Amps complete with one single pole 240V with 20 Amps MCB including disconnecting and removal of old one. Make : Havells /Legrand/C&S/Anchor
Supply & Fixing in replacement of sheet metal enclosure DB, 8 way, SPN, double door factory made powder coated including neutral and earth link connector flush fixed in wall complete including dismantling of old one complete all as specified and directed.
Supply & Fixing in replacement of submain wiring with 2 Runs of 2.5 Sqmm, PVC insulated, unsheathed, single core, multistranded, 1100 volts, FRLS copper conductor cable drawn in and including 25/32mm wide PVC conduit concealed with all accessories as required along with 1 run of 2.5 sqmm PVC insulated, unsheathed, single core, multi stranded copper conductor cable as continuous earth wire and connecting to existing main switch board/Distribution Board and testing on completion all as directed by Engineer-in-Charge.
Supply & Fixing in replacement of submain wiring with 2 Runs of 4 Sqmm, PVC insulated, unsheathed, single core, multi stranded, 1100 volts, FRLS copper conductor cable drawn in and including 25/32mm wide PVC conduit concealed with all accessories as required along with 1 run of 4 sqmm PVC insulated, unsheathed, single core, multi stranded copper conductor cable as continuous earth wire and connecting to existing main switch board/Distribution Board and testing on completion all as directed by Engineer-in-Charge.
Supply and fixing in replacement of lamp holder(angle/batten holders), PVC/Polycarbonate type internally pre-wired with suitable size and testing complete all as directed by Engr-in-charge.
Supply & fixing brushless direct current (BLDC) ceiling fan 1400mm sweep (ISI Marked), 230 volts, 26 Watt includung connection rod as per existing size of length of GI pipe medium grade including dismantling of old one and depositing in MES store yard as per specified and directed by Engr-in-Charge. Make : Orient/Havells/Bajaj
Supply & fixing exhaust fan 250 mm sweep plastic body, 230 volts including dismantling of old one depositing in MES store yard as per specified and directed by Engr-in-Charge. Make : Usha/Havells/Bajaj
Supply and fixing in replacement of LED tube light fitting surface and wall mounted batten with 20 watts LED having minimum 100 lumens/watts and with integrated electronic driver complete made up of polycarbonate complete all as specified and directed.
Supply & Fixing in replacement of LED inverter bulb of 9/10W with base B22/E27 working on AC supply in normal mode and DC supply in inverter mode,with in built battery backup of upto 4 hrs ,high efficiency , high lumens output complete all as specified and directed. Make :Shakti/luker/C&S/Wipro/Crompton
Supply & installed storage type water heater (Geyser) capacity 25 Ltrs five star rating GMV type prefixing and grouting work for mounting nuts,bolts and washer etc in wall and reconnecting all inlet/outlet/vent pipees electrical/earthing connections and carrying out testing for proper functioning including dismantling of old geyser and deposited in MES store yard all as per directed and specified by Engr-in-charge. Make : Havells/Bajaj/Venus
M/L for earthing complete with steel earth plate eletrode 60cm x 60cm x6mm thick buried dirctly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plat not less than 1.5 mtr below ground level connected to GI wire 4 mm dia by means of bolts. nuts,check nuts and washers etc including protection pipe 15mm dia up to 7.5m length , provision the earth lead to earth connection in ther main distribution box with lugs and GI nuts,bolts, earthing shall be done all as per shown electrical plate No 5 of SSR part 1 Including neccessary excavation disintergrated hard rock filling earth of 15 mm thick and privision of earth pit provision of 20mm dia eith funel PCC earth chamber 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing in presence of Engr-in-Charge.
M & L for earthing complete with steel earth plate eletrode 60cm x 60cm x6mm thick buried dirctly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plat not less than 1.5 mtr below ground level connected to GI earth strip 25x4mm by means of bolts. nuts,check nuts and washers etc including protection pipe 15mm dia up to 7.5m length , provision the earth lead to earth connection in ther main distribution box with lugs and GI nuts,bolts, earthing shall be done all as per shown electrical plate No 5 of SSR part 1 Including neccessary excavation disintergrated hard rock filling earth of 15 mm thick and privision of earth pit provision of 20mm dia eith funel PCC earth chamber 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing in presence of Engr -in -Charge.
Supply and fix for DWC high density polyethylene pipes of dia size 50mm, having outer side wall corrugated and inner surface plain confirming to IS 14930 (Part-I & II) for protection of underground cable laid in trenches/floor/fixed on pole/wall including all fittings and clamps as required complete all as specified and directed.
Supply & fixing UG LT cable XLPE insulated armoured heavy duty 1100 volts grade with aluminium conductor multistandardedof size 95 sqmm 3.5 core including centre gland, lugs, jointing materials etc laid in trenches/floor or fixed it to wall and taking down old unserviceable cable.
M/s. R.S. LAWANDE
M/S P S BABU
K M SUBHANAIAH
M/S DUBAL CONSTRUCTION
SHIVRAJ CONSTRUCTIONS
M/S Kartik Enterprises
M/S jvsr constructions
M/s VEEJEE ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .