Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹60.5 LAccepted-AOC UC I USHA PARK HARI NAGAR NEW DELHI 64 | NEW DELHI | DELHI | 110001 | L1 | Accepted-AOC First Lowest | |
| 2 | L2₹62.2 L+₹99,912.96 (1.63%)Rejected-AOC | L2 | Rejected-AOC Second Lowest | |
| 3 | L3₹62.8 L+₹1.7 L (2.73%)Rejected-AOC | L3 | Rejected-AOC Third Lowest |
| Sl No | Description | Qty | Unit | SRI BALAJI ELECTRICALS L1 | Ganesh Electricals L3 | Mohan M L2 |
|---|---|---|---|---|---|---|
| 1.00 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End ) | 155 | Pts | 2,610 ₹4,04,550 Lowest | 2,650 ₹4,10,750 | 2,630 ₹4,07,650 |
| 2.00 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End. | 26 | Pts | 2,180 ₹56,680 Lowest | 2,240 ₹58,240 | 2,220 ₹57,720 |
| 3.00 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3 pin module socket with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point (8 points / Coil) Higher End | 7 | Pts | 2,020 ₹14,140 Lowest | 2,080 ₹14,560 | 2,060 ₹14,420 |
| 4.00 | Supply and run of 1.5sqmm pvc insulated sc unsheathed FRLS copper wire of 1100v grade in the existing concealed PVC pipe with necessary connection complete. | 300 | Mtrs | 36 ₹10,800 Lowest | 37 ₹11,100 | 37 ₹11,100 |
| 5.00 | Wiring with 2x1. 5 sq.mm .PVC insulated single core unsheathed FRLS copper conductor cable of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accesories with MS switch Box and 5A FT switch with painting of suitable colour continuous earth wire connection of 1.5 sq.mm copper wire for light point / fan point (for electronic regulator) | 8 | Pts | 3,440 ₹27,520 Lowest | 3,540 ₹28,320 | 3,510 ₹28,080 |
| 6.00 | Wiring with 2 x 1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with 150mm x 100mm x 75mm MS switch box for 5A 3 pin non interlocking flush type CS plug with painting of suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for open plug point. | 8 | Pts | 1,770 ₹14,160 Lowest | 1,820 ₹14,560 | 1,800 ₹14,400 |
| 7.00 | Supply and fixing of 4Feet LED 20W Fitting with LED 20W tube (HigherEnd)complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting | 43 | Nos | 1,090 ₹46,870 Lowest | 1,120 ₹48,160 | 1,110 ₹47,730 |
| 8.00 | Supply and fixing of 36W LED 2x2 square type Flat panet recessed mounting fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. | 15 | Nos | 4,270 ₹64,050 Lowest | 4,390 ₹65,850 | 4,350 ₹65,250 |
| 9.00 | Supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. | 38 | Nos | 1,710 ₹64,980 Lowest | 1,760 ₹66,880 | 1,750 ₹66,500 |
| 10.00 | Supply and fixing of 9 W Philips LED bulb for existing BH point. | 21 | Nos | 320 ₹6,720 Lowest | 330 ₹6,930 | 330 ₹6,930 |
Tender Value
₹60.5 L
EMD Value
₹40,250
Closing Date
7 Oct 2025, 3:00 pmClosed
Superintending Engineer
Office of the Superintending Engineer, PWD., Buildings Construction and Maintenance Circle, Tirunelveli
Providing Internal and External Electrification and Power Main arrangements to the Additional Building in Government Hospital at Boothapandy in Kanniyakumari District
2025_PWD_607534_1
20(5)SE/2025-26 dated.15.09.2025
Open Tender
Electrical Goods/Equipments
Lump-sum
210 days
Boothapandy
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹40,250
9 Dec 2025
23 Sept 2025
10 Oct 2025
23 Sept 2025
7 Oct 2025
23 Sept 2025
Amount
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End )
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End.
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3 pin module socket with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point (8 points / Coil) Higher End
Supply and run of 1.5sqmm pvc insulated sc unsheathed FRLS copper wire of 1100v grade in the existing concealed PVC pipe with necessary connection complete.
Wiring with 2x1. 5 sq.mm .PVC insulated single core unsheathed FRLS copper conductor cable of 1100 V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accesories with MS switch Box and 5A FT switch with painting of suitable colour continuous earth wire connection of 1.5 sq.mm copper wire for light point / fan point (for electronic regulator)
Wiring with 2 x 1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with 150mm x 100mm x 75mm MS switch box for 5A 3 pin non interlocking flush type CS plug with painting of suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for open plug point.
Supply and fixing of 4Feet LED 20W Fitting with LED 20W tube (HigherEnd)complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting
Supply and fixing of 36W LED 2x2 square type Flat panet recessed mounting fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of 9 W Philips LED bulb for existing BH point.
Supply and fixing of 24W LED square type surface mounted fitting with LED (Higher end) on ceiling with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of WT bulk head fitting with guard suitable with 7W / 9W LED bulb
Supply and fixing of 6W deep recessed LED down light LED fitting (Higher End) complete on false ceiling with PVC unsheathed FRLS copper Leads from terminals to the fitting.
Supply and fixing of 1200mm (48") sweep AC ceiling fan complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 600mm down rod with fan clamp with side plates and cross arm of size 450mm (18").
Supply and fixing of 1400mm (56") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 600mm down rod with fan clamp with side plates and cross arm of size 450mm (18")
Supply and fixing of 400mm sweep wall mounting fan ( heavy duty ) ( Orient make ) concrete on wall with connection complete.
Supply and fixing of 300mm (12") sweep (light duty) AC exhaust fan complete without provision of hole in the wall.
Supply and fixing of louvers shutters arrangements for 300mm (12") sweep (light duty) AC exhaust fan.
Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting.
Supply and fixing of 3nos.6A two module 3 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End.
Supply and fixing of 3nos.6A two module socket , 1 no. 6/16A two module socket , 3 nos. 6A one module switch, 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End.
Supply and fixing of 32A, 10kA Double pole MCB in sheet steel enclosure in flush with wall and making good of the concealed portion with necessary earth connection. (The MCB and metal enclosure should be of Higher End).
Supply and fixing of 32A FP MCB in sheet steel enclosure in flush with wall and making good of the concealed portion with earth connection. (The FP MCB and metal enclosure should be with Higher End make.
Supply and fixing of 63 A FP MCB in sheet steel enclosure in flush with wall and making good of the concealed portion with earth connection. (The FP MCB and metal enclosure should be with Higher End make.
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End.
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End.
Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A 4P MCB switch as incoming and 12 nos. 10A to 20A SP MCB as outgoing in flush with wall with earth connection only.( Higher End )
Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB as incoming and 12 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End
Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 No. 63 4P MCB switch as incoming and 4 nos. 32 A TP MCB as outgoing in flush with wall with earth connection only. Higher End.
Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 No. 100 4P MCB switch as incoming and 4 nos. 32 A TP MCB and 12 Nos 6 A -32A SP MCB as outgoing in flush with wall with earth connection only. Higher End.
Supply and fixing of 8 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board with double door (metal) with 1 No. 125 FP MCCB switch as incoming and 5 Nos 63 A TP MCB and 3 nos. 32 A TP MCB as outgoing with suitable cable end box in flush with wall with earth connection only. Higher End ( LDB Main )
Supply and fixing of 125A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with Earth connection only.
Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour.
Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed portion with suitable colour.
Supply and run of 2 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with contiinuous earth wire connection of 6 sq.mm copper wire and making good of the concealed portion with suitable colour.
Supply and run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 6 sq.mm copper wire and making good of the concealed portion with suitable colour.
Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position.
Supply and Run of 4 of 25 sq.mm. PVC insulated SC unsheathed copper conductorof 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 16 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour.
Supply and clamping of 3 1/2 x 25 sq.mm PVC LTUG armoured cable on post or on wall with MS clamps.
Supply and fixing of brass cable gland for 3-1/2 x 25 sq.mm. PVC armoured LTUG cable with earth connection
Supply and providing cable end termination of 3-1/2 x 25 sq.mm .PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
Supply and laying of of 31/2 x 150 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 Mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.
Supply and clamping of 3 1/2 x 150 sq.mm PVC LTUG armoured cable on post or on wall with MS clamps.
Supply and clamping of 3 1/2 x 150 sq.mm PVC LTUG armoured cable through GI pipe on post or on wall with MS clamps.
Supply and fixing of brass cable gland for 3-1/2 x 150 sq.mm. PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3-1/2 x150 sq.mm .PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
Supply and clamping of 3 1/2 x 95 sq.mm PVC LTUG armoured cable on post or on wall with MS clamps.
Supply and fixing of brass cable gland for 3-1/2 x 95 sq.mm. PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3-1/2 x95 sq.mm .PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
Supply and fixing of 63A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with earth connection only.
Supply and fixing of 200 A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with earth connection only.
Supply and fixing of dust and vermin proof cubical type LTCT metering box of size 3ft x 1 ft x 4 ft made of 16SWG CRCA sheet steel with door, lock and key arrangement with angle iron support comprising of three compartments for 3 phase energy meter with base plate & view glass arrangements, bus bar arrangements wit 1" x 1/4" insulated tinned copper bus bar for 3 phases & neutral with provision for CTs and sealing arrangements as per TNPDCL norms and 3 nos 200A ( 500V) fuse units and MS cable entry box. The earth bus with two runs of 1" x 1/4" tinned copper flat must be run all round the panel to provide double earth connection.
The buses should be mounted on the SMC bus insulators with proper spacing and should be provided with heat shrinkable sleeves using RYB & Black colours. The bus bar chamber should be segregated from the adjacent chambers by providing 12mm thick hylem sheet. The panel should be powder coated, the cable size, location etc., should be marked with white paint affixed with Danger sign with 19/16 PVC insulated Cu wire interconnection from meter to fuse unit and necessary connection complete confirming CEIG specifications.
Supply and fixing of 3 phase 200A aerial fuse unit for 3 Nos. 32A fuse units (500V) on suitable MS sheet covered with 6mm thick hylem sheet on suitable angle iron work the tapping pole with necessary clamps.
Supply and fixing of 2kVA Single Phase In & Single Phase out Online UPS of Microcontroller based High frequency and Double Conversion Online Technology with inbuilt isolation transformer system, LCD/ LED Display with suitable SMF battery to provide minimum 1 hour backup along with Powder coated MS Rack and interlink cables with following specifications:
1. Output Voltage Range : 208V/220V/230V /240V AC 2. Voltage THD (Linear Load) : ≤2% 3. Voltage THD (Non-Linear Load) : ≤4% 4. Current THD : < 10% 5. Overload : >110%, 30s turn to Bypass mode; >150% instant turn to Bypass mode
6. Short Circuit protection : 5 cycles turn off inverter, no transfer to Bypass, provide Alarm (ACmode) ; 5cycles turn off inverter, provide Alarm (Battery mode), Input fuse blown or breaker action
7. Waveform : Pure sinewave 8. Transfer time : (AC mode to Battery mode - Zero) (Inverter to bypass - <4ms) 9. Efficiency : 85% to 92% 10. Noise Level : less than 50dBA @ 1meter (with fan speed control) 11. Warranty : Two years on Electronics & one year on battery. (Microtek / Numeric make / Eq), (Battery make : Exide -6 Nos) The make and model should be approved by the departmental officers before used on work.
Supply, Fabrication ,Erection and Commissioning of 200 A dust and vermin proof floor mounting cubical type metering panel board of size not less than (size 5 Ft x 4Ft x 1 Ft) made up of 16SWG CRCA sheet steel for outer body on suitable base channel (3"x11/2"x1/2") iron frame work supports. Supply and fixing of following intermounting switches with centre bus bar chamber and vertical rows of switches one over the other on both sides powder coated and superscription of incoming and outgoing feeder cable details and 2 nos metallic danger board mounted on base channel confirming to IS specification and CEA regulations.
1. 200 A FP switch disconnector fuse units interior only with HRC fuses double break - 1No (L&T/Simens) for incoming
2. 125 A TPN switch disconnector fuse units interior only with HRC fuses double break - 2Nos (L&T/Simens)
3. 63 A TPN switch disconnector fuse units interior only with HRC fuses double break - 6Nos (L&T/Simens)
The busbar chamber should have 4 nos 1"x 1/4 " tinned cu. flat for 3 phases and neutral , 2 Nos 1'x 1/4"tinned cu. flat for earth connection all around the panel. The buses should be mounted on synthetic moulded compound bus supports as per IS specification.
The incoming 200A switch should be connected to the busbar 1"x1/4 " tinned cu. flat . 1 No 200 A switches should be connected to the busbar 1" x 1/4" , 2 Nos 125 A should be connected to busbar with 1" x 1/8" cu. flat and 6 Nos 63 A should be connected to the bus by 3/4 "x 1/8 " cu. Flat . The switches should be separated 6 mm thick hylem sheet and all switches should be properly earthed and as per CEA specifications.
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection .
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection.
Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry.
AC Arrangements
Supply erection testing and commissioning of 2.0 TR (6000 K.cal/hr) plastic split type Air conditioner filted with rotary high efficiency compressor operating on non CEC refrigerant suitable for wall mounting for operation on 230 V, 50HZ single phase AC supply with star rating of 3 as per BEE specification and capable of performing the function. (1) Cooling (2)Dehumidifying (3) Air circulation (4) Filtering (5) Heat pump for winter
This installation works for the above split type AC units including the following
(1) Mounting / Filtering Indoor and Outdoor units at their respective Locations.
(2) Laying refrigerant pipe line of required length connecting both units after drilling hole/ holes in the wall if required. Thickness of the copper tubing shall not be less than 0.8 mm
(3) Insulating the suction pipe with expanded polyethylene foam 5 mm tubing.
(4) Laying 25mm dia flexible PVC drain pipe to throw out the condensate water being form within the indoor unit'
(5) Leak testing the entire system unit.
(6) Charging refrigerant gas in the unit.
(7) Suitable electric wiring to be provided with in 2.5 sq.mm PVC insulated copper wire between indoor and outdoor units upto 6 mtrs length and upto switch within 3 mtrs of location of indoor unit. (carrier/Voltas /Blue star/equ)
Supply and Installation of 5 kVA electonic automatic voltage stabilizer V-Guard make VGS 500 with input Voltage range of 170 V-270 V and output range 200 V-240 V with high and voltage cut off and 3 miniutes time delay relay with demonstration.
Supply and fixing of MS stand for fixing outdoor unit.
Supply and laying of 5/8" and 3/8" copper pipe (Extra beyond 3 metres supplied with AC unit).
DX AIR COOLED CONDENSING UNITS: Design, supply, installation, testing and commissioning of 5.5TR Nominal capacity DX Air-cooled Condensing unit fixed with energy efficient R410A Refrigerant scroll compressor along with grooved copper tube/aluminium fins air cooled condensor coil with anticorrosion coatings,liquid, accumulator, low noise alumimium propeller condenser fan with Fan motor etc all suitably assembled neatly in heavy duty GSS sheet metal cabinet and duly powdercoated as per specification .the unit to include built in safety controls like HP/LP switch power quality protector, in built thermal / temperature protection. (carrier/Eq.)
Supply ,installation , testing and commissioning of 2200 CFM 5.5 TR Nominal capacity factory assembled double skin AHU Ceiling mounted with 50mm-45kg/cum PUF Insulated detachable panels, extruded thermal break aluminium profiles filled with PUF, panel external skin with 0.6 mm preplasticized sheet, panel internal skin with 0.6mm galvanized sheet, AMCA tested DIDW backward /forward curved centrifugal fan with EFF1 rating motor, drive arrangement with taper lock pulleys for fan and motor, vibration isolators out of heavy duty rubberized mounts, prefilters ith 3ply HDPE 50mm thick filters having an efficiency of 90% 10mic, 6row /12FPI deep DX copper cooling coil with copper header and aluminium fins, GI mist arrestor, condensate coil trough with SS304-20G insulated with 9mm closed cell elastomeric foam, guard for inspection door , out let damper of aerofoil blades &PVC gears and flexible fire retardant canvass complete with galvanized hardware. each of the cooling coils will have independent distributers, electronic expansion valve kit, catch all drier, independent DX coil circuit to connectivity to each ODU circuit. (carrier make / Eq)
Supply,Installation, Testing and commissioning of laminar floor arrangements with HEPA filter, frames etc. 8 ft x 6 ft for OT ceiling suspended provides ultra clean sterile CLASS 100 clean air and designed as per CLASS 5 of ISO 14644 - 1 standards with air plenum at aluminium power coated 1 mm thick casing with aluminium pleat CEPA filters and 0.3 micron 99.97 % efficiency and SS 304 perforated grill with 13 mm thickness XLP insulation with modular housing. Frame : Aluminium, Flange type Filter. Media: Micro Glass fibre, sealant : Plolyurethane with Air flow as per standards suitable for 5.5 TR
Supply & fixing of hard drawn copper refrigerant piping of suction line of size 22.2 mm with necessary fitting and clamp.
Supply & fixing of hard drawn copper refrigerant piping of liquid line of size 12.70 mm with necessary fitting and clamp etc.
Supply and filling of R-410A Refrigerant gas.
Supply, Fabrication and erection of fabricated ducting made up of Aluminium sheets of 20 Gauge thickness .
Supply, Fabrication and erection of fabricated ducting made up of Aluminium sheets of 22 Gauge thickness.
Supply and fixing of extruded aluminium powder coated supply and return air grilles /diffuser with volume control damper .
Supply and fixing of 1 inch PVC water drain pipe line on wall with suitable clamp as required .
Supply, fabrication and fixing of suitable MS Channel for Mounting the Airconditioning Oudoor Unit.
Supply and providing of pipe line nitrle rubber insulation for Refrigerant and drain pipe lines.
Supply and fixing of duct mouth Dampers.
Supply and providing Acoustic for initial portion of duction with 12mm thick fibre glass rigid board covered with tissue paper and aluminium perforated sheet.
Supply and providing thermal insulation of 9mm thick vidoflex with Aluminum Foil.
Generator Arrangements
Supply, Testing Commissioning and Handing over of 58.5 KVA Diesel Generator set with acoustic enclosure conforming to CPCB IV + Norms and BIS specifications with AMF panel of 0.8 P.F. Three phase 415V / 420 Volts, 50Hz, 1500 RPM CPCB Approved capacity developing 74 BHP
with acoustic enclosure water cooled clock wise rotating feed pump with 46.8KW /58.5 KVA operating capacity brushless alternator close coupled underneath fuel tank standard safeties LLOP with stop solenoid battery with lead Electric start and Vibration fitting and accessories and AMF panel as detailed below including transporting & unloading charges.
(A) Engine: Water cooled diesel engine suitable for Generator application conforming CPCBIV + norms and IS standards with a shaft out put of 74BHP at 1500 RPM under NTP conditions. The Engine shall comprise the following standard fitting flexible coupling fly wheel, air cleaner, fan blower, radiator, water pump, fuel filter, lubricating oil filter, etc
(B) 12/24 Volt Electronic Starting Equipment: Complete with starter motor, dynamo, standard batteries with cable, flexible exhaust piping of 50cms length.
(C) Engine Instrumental Panel / Mounted: Starting push botton / starting key, lubricating oil, temperature gauge, lubricating oil pressure gauge, water temperature gauge, safety control for low lubricating oil, pressure, safety control for high water temperature, safety control for over speed, hour meter (mechanical) and RPM indicator, battery charging ammeter. The engine should be capable of providing 10% over load for one hour for every 11 hours continous at full load.
D) ALTERNATOR: 58.5 KVA / 46.8 KW capacity of brushless alternator, AC 3 phase, 50Hz, 415/420V, 0.8 PF, 1500 RPM under NTP conditions, conforming to CPCB IV + Norms. E) AMF CONTROL PANEL: The AMF control panel (cubical) should be fabricated with vermin proof and dust proof best quality sheet steel and floor mounted with removable rear panels and hinged front doors with enamel painted and incorporating the following with suitable provision for connection incoming and outgoing leads having been made on the control panel.
17. I no Push button "Reset" 18. I no signal lamp for indicating load on mains 19. I no signal lamp for indicating load on set. 20. I no signal lamp for indicating set fails to start 21. I no signal lamp for indicating set running 22. I no signal lamp for indicating battery 23. I set pilot lamps of 3 nos 24. MCCB of suitable capacity with magnetic thermal overload release, instant start circuit trip and under voltage release switch. 25.Rectangular copper bus bars (1 No for each phase, neutral and earthing terminals) of adequate capacity duly colour coded with head shrinkable PVC sleeves. 26. I No mains voltage monitor. 27. Hooter / Audio alarm for indicating set fails to start and for DG O/L. 28. I set Timers. 29. Audio and visual indicator arrangements for: a.Low lubricating oil pressure. b. High water temperature c. Over speed
30. 1 No Earth fault relay 31. Isolator to isolate the neutral.
1. The control panel should be complete with necessary fuses, cables, label, other accessories with neutral isolation arrangements. 2. The engine should trip for the following: a. Low lubricating oil pressure b. High water temperature c. Over speed 3. Supply and fitment of Auto Mains Failure Panel, 1 EB service with switch and contractors SUF control relays, timers etc suitable for auto change over of DG & EB service.
F. FUEL TANK 165 litres fuel tank shall be fabricated out of 14 SWG CRCA MS sheet and is part of base frame. It is duly painted and fitted with inlet and outlet connections and mechanical fuel gauge. Fuel tank can be easily removed for cleaning or any maintenance.
G. Exhaust Gas Recirculation system arrangements as per CPCB IV + norms as amented H. BASE FRAME: Base frame should be fabricated with MS channel frame of rigidly welded construction for mounting of generator set. The engine and alternator should be coupled by suitably designed diaphragm type flexible coupling with guard and mounted on the base frame with prooper alignment.
I) ACOUSTIC ENCLOSURE: The Acoustic enclosure, Self standing weather proof Acoustic canopy conforming CPCB IV + norms floor mounting type with modular contruction with the provision to assemble and dismantle easily and designed to suit all weather conditions and compliance to IS standards.
Erection of acoustic enclosure suitable for 58.5 KVA Diesel generator complete competent authority to suit updated CPCB norms.
J) Erection of generator set with proper alignment over the existing foundation.
K) Supply of mauals for operation & maintenance of DG set with warranty card etc., L) CEIG approval: Preparation of site plan physical layout, electrical line shematic Diagram 10 sets, getting drawing approval from CEIG preparation of complection report rectification report etc., arranging CEIG inspection and obtaining CEIG safety certificate, payment of CEIG inspection fees if necessary and preparation of one set of approval Drawing and copy of safety certificate in a neat frame work.
M) TESTING AND COMMISSIONING After the installation of DG set on its foundation, the DG set should be tested and commissioned with first charging of lubrication oil to its level, first charging of battery and run the set for eight hours on full load test complete. The Genset engine and alternator make should be approved by department officials before used on work.
Providing suitable concrete foundation with plain cement concrete 1:2:4 using 20mm jelly for wearing coat including laying, compacting, finishing and curing etc., complete as per standard specifications and as directed by the departmental officers for 58.5KVA Genset.
Mohan M (BID ID -1478112)
Ganesh Electricals (BID ID -1478119)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .