Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.4 L+₹3.0 L (22.7%)Rejected-AOC | L2 | Rejected-AOC Not Being L1 | |
| 3 | L3₹16.8 L+₹3.4 L (25.7%)Rejected-AOC | L3 | Rejected-AOC Not Being L1 |
Tender Value
₹15.8 L
EMD Value
₹31,600
Closing Date
11 Jul 2020, 6:00 pmClosed
Lt Col Abhyudaya Pant
GE EM RR Hospital Delhi Cant 10
PROVISION OF CERTAIN SANCTIONED WORKS AT AHRR UNDER GE E/M RR HOSPITAL DELHI CANTT 10
2019_MES_310843_3
GE/H-30/2019-20
Open Tender
Civil Works
Item Rate
180 days
GE EM RR Hospital Delhi Cant 10
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE EM RR Hospital Delhi Cant 10
₹31,600
Yes
17 Aug 2020
26 Jun 2020
13 Jul 2020
26 Jun 2020
11 Jul 2020
29 Jun 2020
Amount
Demolition of brick work built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as directed.
M & L for brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 etc, complete all as directed.
M & L for 15mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement , complete all as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of alkali resistant primer complete all as specified and as directed by the Engr-in-Charge.
Taking down chowkhat or frames with shutter (without taking off shutter from frame) area exc 1.50 Sqm but n .exc 4.00 sqm each.
M&L factory made Radiation Protection door made out of 35 mm thick flush shutter solid core construction with block board core and plywood face pannels,commercial type on both side and one continious layers of lead sheet of 2 mm(+ 1%) thickness with 99% purity sandwiched inside including necessary fitting fixure as per site requirement to make fully functional complete all as per manufacturer's specifications and as directed by Engr-in Charge.Make/ Manufacturer:- LIBRA HEALTHCARE, HERMED MEDITECH SOLUTION, MEDICRAFT TECHNOLOGIES. Note: The door shall be procured and fixed at site through approved manufacturer or their authorised supplier/rep only.
M&L 20mm thick transparent glass fixed in wall all complete all as directed by Engr-in Charge.
Dismantling brick tiles or terracing tiles single layer on roofs.
Demolition of mud/mud phuska in roofs any thickness, including plastering and leaping if any and clearing the roof surfaces with wire brushes complete all as specified.
Taking up or down 20 mm bore steel tubing and connections laid in wall ceiling floor etc and cleaning for refixing or removal from store complete all as specified and directed.
All as per item No 10 here in before but 25 mm bore of pipe.
Refixing 20mm bore old steel tubing and connections in new or old position in wall,ceiling,floor etc complete all as specified and directed.
All as per item No 12 here in before but 25 mm bore of pipe.
M&L cement concrete 1:2:4 type B1 using 20 mm graded stone aggregates as in roof padding all as specified and as directed.
M&L, Priming roof surfaces and applying water proofing treatment over roofs comprising of the following complete all as specified & as directed:- (a) Applying oil bound bituminous primer at the rate of 0.4 Ltrs/Sqm as per IS 3384-1986 on prepared surfaces. Surface shall be kept free till the moment, the primer is impregnated and the solvent oil in primer is evaporated. (b) Applying one coat of hot straight run bitumen @ 1.20 Kg/Sqm of grade 30/40 confirming to IS-73 (Grade S-35). (c) Laying 3mm thick APP polymeric water proofing membrane of weight not less than 3.0 kg/sqm, black finish reinforced with non woven polyster matt, with a thermo fusible finish, torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer's instruction including preparation of surface. (d) Applying one coat of hot straight run bitumen grade 30/40 (Grade S-35) conforming to IS-73 @ 1.20 kg/Sqm. Make: "(a) Mukti-Plas-M/s Texas (b) Shalimar Tar Products (c) Tikitar (d) Torch Tar (e) Hyperplas from IWL India Ltd (f) STP Ltd as approved by GE. Note :- The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators. The contractor shall give 10 years guarantee for effectivenss of water proofing treatment, 2.5% of work done amount of this item shall be retained from contractors payment for a period of 10 years reckoned from date of physical completion of this work, or inlieu contractor may deposit bank FDR for the said amount for 10 years which shall be released by GE on expiry of satisfactory completion of 10 years period.
M&L for pre- cast PCC tiles machine pressed of size 250mm x 250mm x 20 - 25mm thick over and including 15mm thick screed bed in Cement Mortar 1 : 6 and joints grouted flush in cement mortar 1:3 mixed with WPC as per manufacturer instruction complete all as specified.
M&L PCC 1:2:4 type B 1 using 20 mm graded stone agg as in roof kerbs benching finished even and smooth without using extra cement complete all as specified.
Disconnecting existing tanks exc 250 & n exc 500 Ltrs capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and refixing in position.
Dismantling over head water tank of capacity exc 1000 Ltrs but not exc 2000 Ltrs.
S&F 2000 Ltrs capacity rotational moulded PVC water storage tank (cylindrical vertical with close top ) double layer including 20mm PVC float valve complete all as specified and directed.
S&F 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed
M&L 25mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed
Removal of demolished material or soil (beyond 50 Mtr from demolished site) to a distance n.exc 500M and depositing where directed at a level n.exc. 1.5 M above the starting point.
S&F ceiling fans 1400 mm sweep ( five star BEE rating) complete including electronic regulator and fixing accessories complete all as directed. Make: BAJAJ, CROMPTON GREAVES, HAVELLS, POLYCAB .
S&F of exhaust fan AC single phase 220-240V of size 300 mm sweep, 900 RPM metal body with self closing louver heavy duty complete all as directed. Make: BAJAJ, CROMPTON GREAVES, HAVELLS, POLYCAB .
S&F of exhaust fan AC single phase 220-240V of size 225 mm sweep, 900 RPM metal body with self closing louver heavy duty complete all as directed. Make: BAJAJ, CROMPTON GREAVES, HAVELLS, POLYCAB .
M&L for point wiring complete with single core fire retardant, PVC insulated, unsheated multistranded copper conductor of size 1.5 Sqmm alongwith 1.5 sqmm multi stranded copper conductor PVC insulated earth wire drawing in and including PVC Caping and caping medium grade including sheet metal concealed boxes and plate for fixing of switches, sockets or fan regulators etc including necessary repair work to make the disturb surface as per existing for fan point complete all as directed.
Supply and fixing Ceiling rose, insulated body, 3 terminal, 240 volts, 5 Amps complete all as directed.
Supply and fix switch piano type 1 way, single pole, 5 Amps all as directed.
M&L for cutting holes upto 300 mm dia for housing Exhaust fan of 300 mm/225 mm dia, into existing external/internal brick walls (building up to 8 storeyed buildings) including making good the disturbed surfaces(i.e rendering, white wash, OBD ,snowcem etc as per site condition) as per existing surface complete all as directed by Engr-in Charge.
ACR ENTERPRISES
PARGATI TOWER CORPORATION
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .